This document appears to be a product description for the Veeder-Root TLS-450PLUS Automatic Tank Gauge Console. The console is a powerful tool that allows fueling operations to run efficiently, with features like easy navigation, inventory and compliance reporting, and business analytics. It can monitor up to 64 tanks or 32 tanks with Business Inventory Reconciliation. The document outlines the standard hardware and software components included, as well as device and communications module compatibility.

The related federal contract opportunity is for the Air Force Nuclear Weapons Center to acquire a Veeder-Root 450+ Fuel Monitoring System for delivery to F.E. Warren AFB in Cheyenne, Wyoming. This is a brand-name justified acquisition, as the Veeder-Root product is the only one that meets the customer's requirements. The solicitation number is FA821424Q7003, and quotes are requested to be submitted to Torrey Boggs at the contracting office.

View the file

Other files

File Type Posted
FA821424Q7002.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TLS-450PLUS Automatic Tank Gauge

Console Description

The TLS-450PLUS Automatic Tank Gauge (ATG) is a powerful tool that allows fueling operations to run at peak efficiency, with easy to understand navigation, streamlined inventory and compliance reporting, and powerful business analytics. It can monitor up to 64 tanks, or 32 tanks with Business Inventory Reconciliation (BIR). Frequent releases of operating software for the TLS-450PLUS tank gauge assures that data is secure and software features are routinely updated and enhanced.

TLS-450PLUS

Consoles, Standard Hardware & Software

Part # & Description Standard Hardware & Application Software

0860091-302 TLS-450PLUS Console with 8” Color Touch Screen Display, Printer, 3 Ethernet and Dual USB/Expansion, Dual RS-232/ RS-485, UL/cUL

Software – 0333545-001 Application Software (must be ordered with Console) includes Web-enabled, Custom Alarm, On-Console Help, Extended Storage, TLS-Expansion, Static Leak Detection, 3 GPH DPLLD

Hardware – 8” Color Touch Screen Display, Printer, 3 Ethernet and Dual USB/Expansion, Dual

RS-232/RS-485

TLS-450PLUS Device & Communications Module Compatibility

Devices

Communications

Module Compatibility

Inputs Per Module

Po w er M od ul es

Console TLS-XB 1 TLS-XB 2 TLS-XB 3 Modules

Per SystemSlots Slots Slots Slots

1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4

TLS-450PLUS System

USM 16 • • • • • • • • • • • • • • • • 16

UIOM 141 • • • • • • • • • • • • • • • • 16

10-Amp Relay 6 • • • • 4

MDIM 12 • • • • • 5

LVDIM 12 • • • • • 5

1 (14) total inputs include (5) AC Inputs, (5) Relay Contracts, (4) 12VDC Inputs

Module

Co m m un ic at io n

M od ul es

Console Modules

Per System Type1 4 2 3 4 5

P1 P2 P1 P2 P1 P2 P1 P2 P1 P2

TLS-450PLUS System

RS-232 • • •

Et he rn et

M od ul e

(3 P or ts

(F ix ed

US

B

M od ul e

(2 P or ts

(F ix ed

3 Hardware

Dual RS-232 • • • • 3 Hardware

RS-485 • • • 3 Hardware

Dual RS-485 1 • • • • 3 Hardware

RS-232/RS-485 1 • • • • 3 Hardware

Internal Modem • • • 3 Hardware

CDIM • • 1 Hardware

EDIM 2 • • • • • 3 Software

IFSF LON 3 • • • 1 Hardware

1 When placed in Slot 3, only Position 2 will be functional 2 EDIM can be programmed in any position with an RS-232 port – up to 3 per system 3 Can be combined with EDIM 4 Console ships standard with dual RS-232 or dual RS-232/RS-485 card in Slot 1

TLS-450PLUS

Device Modules

Part # & Description Maximum # of Modules per Console

# of Inputs per Module Availability

Universal Sensor Module (USM) Interface for all Probes, Sensors, and DPLLD

0332812-001 – Factory Installed Module 0330020-619 – Spare Part Module

Up to 4 for each TLS-450PLUS and/or TLS-XB or a maximum of 16 modules per system

Sold Separately

(either Factory Installed or as a Spare Part

Module)

USM Interface for all Probes, Sensors, and DPLLD with ATM Module – TLS-450PLUS Installed

0332812-006 – Factory Installed Module 0330020-619 – Spare Part Module

Up to 4 for each TLS-450PLUS and/or TLS-XB or a maximum of 16 modules per system

16 inputs + 1 Atmospheric Module

(ATM)

Universal Input/Output Interface Module (UIOM) for Relay Control and Input Signal Monitoring

0332813-001 – Factory Installed Module 0330020-620 – Spare Part Module

Up to 4 for each TLS-450PLUS and/or TLS-XB or a maximum of 16 modules per system

5 dry contact output relays / 4 low voltage dry contact inputs /

5 high voltage inputs

(<=240 VAC)

10-Amp Relay Module has 6 high power outputs / 6 low voltage inputs / must be installed in slot 4 of TLS-450PLUS and TLS-XB

0333564-001 – Factory Installed Module 0330020-814 – Spare Part Module

Up to 1 for each TLS-450PLUS and/or TLS-XB or a maximum of 4 modules per system —

* Required to be installed in slot 4 only

BIR/AccuChart™ LVDIM for TLS-450PLUS, 12 Inputs

0333581-001 – Factory Installed Module 0330020-800 – Spare Part Module

Up to 3 per System

BIR/AccuChart MDIM for TLS-450PLUS, 12 Inputs

0333582-001 – Factory Installed Module 0330020-799 – Spare Part Module

Up to 3 per System

TLS-450PLUS

Communications Modules

Part # & Description Maximum # of Modules per System Availability

RS-232 Dual Interface Module (Comm. Slots 1,2,3), for

TLS-450PLUS

Max # of Modules per System:

Up to 3 per system, 2 per console maximum

0332868-001 – Factory Installed Module 0330020-617 – Spare Part Module

Up to 3 per System

Sold Separately (either Factory Installed or as a Spare Part Module)

For Spare Part “upgrade” kits, the BIR/ AccuChart Feature Enhancement will be shipped on a Veeder-Root iButton adapter – P/N 0330020-659

Single RS-232 Interface Module (Comm. Slots 1,2,3), for TLS-450PLUS

0332866-001 – Factory Installed Module 0330020-613 – Spare Part Module

Single RS-485 Interface Module 0332867-001

Dual RS-485 Interface Module 0332869-001

RS-232/RS-485 Dual Interface Module (Comm. Slots 1,2,3), for TLS-450PLUS

0332870-001 – Factory Installed Module 0330020-618 – Spare Part Module

SiteFax™ Interface Module (Comm. Slots 1,2,3), for

TLS-450PLUS

0332818-001 – Factory Installed Module 0330020-612 – Spare Part Module

BIR/AccuChart EDIM for

TLS-450PLUS

0333149-001 – Factory Installed 0330020-801 – Upgrade Kit

1 per SystemBIR/AccuChart CDIM for TLS-450PLUS, 3 Inputs

0333580-001 – Factory Installed 0330020-802 – Upgrade Kit

IFSF LON Interface Module (Comm. Slots 1,2,3), for

TLS-450PLUS

0333659-001 – Factory Installed Module 0330020-828 – Spare Part Module

Specifications

Operating Temperature +32°F to +104°F (0°C to +40°C)

Storage Temperature -40°F to +158°F (-40°C to +70°C)

Installation Location Indoors, climate-controlled space

Relative Humidity 0-90% (non-condensing)

External Dimensions 18.4" x 11" x 8.8" (46.74cm x 27.94cm x 22.35cm)

Construction 16GA (0.060 in/0.1524 cm) powder coated steel

Console Power Wiring Requirements

AC Power Wiring – Wires carrying 120 or 240 VAC from power panel to the console should be #14 AWG (or larger) wire for line, neutral & chassis ground (3); and 4 sq. mm, rated for at least 90C for barrier ground.

Probe & Sensor to Console Wiring Requirements

1. Wire Type – Shielded cable required regardless of conduit material or application. It must be rated less than 100 picofarad per ft manufactured with a suitable material, such as Carol C2534 or Belden 88760, 8760, or 8770.

2. Wire Length – Maximum 1,000ft (304.8m) to meet intrinsic safety requirements. Improper system operation could result for runs over 1,000ft (304.8m).

3. Wire Gauges – Color coded – shielded cable used in all installations. Wires should be #14 - #18 AWG stranded copper wire and installed as Class 2 circuits. As an alternate method when approved by the local authority having jurisdiction, #22 AWG wire such as 88761 may be suitable with the following requirements:

Wire run is less than 750ft (228.6m); Capacitance does not exceed 100 pF/ft; Inductance does not exceed

0.2 uH/ft.

System Power Requirements AC Input – Universal AC power supply: 100 to 249 VAC, 50/60Hz, 2A max

Display Specifications 8” (20.32cm) Color touch screen display

Connectivity Methods Ethernet, Web Browser, Modem, Fax, Serial

Data Storage Features SD card

Software Security Features Centralized Device Management to protect your network of TLS-450PLUS and TLS4 Series consoles

Custom User Access Front Panel Display control through user specific log-in; User defined roles to restrict access / functionality.

Screen permissions can be limited to view, edit, perform.

System Security

1. Partitioned Ethernet Ports that can be used to separate user network from the internet

2. Port availability control: SSH Port (22), HTTPS Port (443), Serial Command Port (10001)

3. Ports may be reassigned (i.e., HTTPS on 50443)

4. System Integrator Common Vulnerabilities and Exposures (CVE) Scans & Fixes

5. Periodic console software updates are available to protect against persistent threats

Customized Alarm Features Customize select alarms

Approvals UL cUL, ATEX, IECEx, NEPSI, FCC, FMC, PESO, ANZEx, ULC, INMETRO, IQC, EAC, NWGLDE, and CEN

Third Party Evaluations http://www.nwglde.org/evals/veeder_root_zf.html

Product Installation Guide https://www.veeder.com/us/technical-document-library

TLS-450PLUS Automatic Tank Gauge

TLS-450PLUS

Optional Software

Part # & Description

Centralized Device Management (CDM) Software 0349889-001 CDM Backup Feature 0334054-001 CDM Change Management 0334054-002 In-Station Diagnostics (ISD) / PMC for TLS-450PLUS Console 0332972-102 Vapor Pressure Management Control (PMC for Carbon Canister Vapor Polisher) for TLS-450PLUS Console 0332972-101

Continuous Statistical Leak Detection (CSLD) for TLS-450PLUS 0332972-006 Ultimate Testing: Digital Line Leak Detection for TLS-450PLUS 0332972-007 Risk Management: Digital Line Leak Detection for TLS-450PLUS 0332972-008 Base Compliance: Digital Line Leak Detection for TLS-450PLUS 0332972-009 Timed Sudden Loss Detection for TLS-450PLUS 0332972-018 Vapor Collection Monitor for TLS-450PLUS 0332972-021

DEF Recirculation Software Feature for TLS-450PLUS & DEF Temperature Sensor Installation Kit

0332972-026 – Software 0332972-027 – Temperature Control Relay

0794380-210 – Installation Kit Secondary Containment Vacuum Monitoring (SCVS) 0332972-029 http://www.nwglde.org/evals/veeder_root_zf.html https://www.veeder.com/us/technical-document-library

System Compatibilities Guide

** TLS-450PLUS with (3) three TLS-XB Expansion Boxes

* Indicates the maximum number of devices the system can handle if all slots/ positions are filled with that type of device

Feature/Console TLS-450PLUS TLS-450PLUS with TLS-XB **

DATA COMMUNICATIONS

RS-232 5 5

RS-485 3 3

Fax Transmittal (SiteFax) Optional Optional External USB 2.0 2 2 Ethernet Ports 3 3 International Forecourt Standards Forum (IFSF) 1 1

SYSTEM CAPABILITIES

Manifold Tank Capability (Line & Siphon) • • Height-Based Pump Priority Control for Manifolded Tanks • • Pump Alternate on the Fly • • Self-Diagnostics • • Emergency Generator Capability • • Up to 3 Years Data Storage • • FAX Notification On-Time or Event Optional Optional Email Notification On-Time or Event • • LCD with Touch Screen Optional Optional On-Board Help • • Custom Help • • Custom Alarms • • Environmental Reports (Compliance Reports Summary) • • Sensor Reports • • Sensor History Report by Period, Month, Week, or Custom • • Web-Enabled • • System Duplicate • •

SYSTEM CAPACITIES *

External Inputs 64 256 In-Tank Probes (Including Density) 64 64 In-Tank Probes with BIR 32 32 Digital Pressurized Line Leak Detectors (Additional Software Req’d) 16 16

2-WIRE SENSORS

Magnetostrictive Discriminating Level Indicating Sump Sensor 64 99 Discriminating Dispenser Pan & Containment Sensors 64 99 Solid-State Non-Discr. Dispenser Pan & Containment Sensors 64 99 Sump Sensors 64 99 Position Sensitive Pan/Sump Sensor 64 99 Interstitial Sensor for Fiberglass Tanks 64 99 Solid-State Discr. Interstitial Sensors for Fiberglass Tanks 64 99 Alt. Ethanol Fluid Interstitial Sensors for Fiberglass Tanks 64 99 Interstitial Sensors for Steel Tanks 64 99 Microsensors 64 99 Position Sensitive Interstitial Sensor for Steel Tanks 64 99 Alt. Ethanol Fluid Solid-State Interstitial Sensor for Steel Tanks 64 99 Hydrostatic Sensors for Brine-Filled Double-Wall Tanks 64 99 Hydrostatic Sensor for Brine-Filled Double-Wall Sumps 64 99 Vacuum Sensor 64 99 Air Flow Meter (AFM) 18 18 Vapor Pressure Sensor 1 Per Site 1 Per Site Vapor Valve 1 Per Site 1 Per Site

3-WIRE SENSORS

Solid-State Discr. Dispenser Pan & Containment Sump Sensors 32 99 Groundwater Sensor 32 99 Vapor Sensor for Monitoring Wells 32 99

INPUT & OUTPUT

Output Relays 21 32 External Inputs Low Voltage 16 32 External Inputs High Voltage 20 32 10-Amp Relay 1 4

Feature/Console TLS-450PLUS

CONSOLE DESIGN

Modular/Expandable Features • 8” Color Touch Screen • Integral Roll Printer • Universal Power Supply •

INVENTORY CONTROL

Graphical Inventory Status • Complete Inventory Reports • Programmable Auto Report Times • Inventory Increase Report • Timed Sudden Loss Detection Optional

BUSINESS INVENTORY RECONCILIATION

Shift-Based Reconciliation Optional Reconciliation by Tank Optional

TANK CALIBRATION

Multi-Pass Tank Calibration Optional Single-Pass / Metered Drop Optional Limited Range Calibration Optional Supports Multiple Tank Charts per Tank Optional Supports Multiple Line Manifold Tanks Optional Graphical / Text Calibration Diagnostics Optional Automatic and Manual Meter Mapping Optional

IN-TANK LEAK TEST

0.1 GPH Tank Tightness Testing •

0.2 GPH Tank Tightness Testing •

Continuous Statistical Leak Detection Optional Selectable Test Rates • Programmable Automatic Test Schedules • PASS, FAIL, or INVALID Indicators •

LINE LEAK DETECTION

Integral Line Leak Detector Optional Programmable Line Test Features Optional

INTERSTITIAL/SUMP LEAK SENSING

Tank Annulus • Sump • Dispenser Pan • MAG Sump • Sensor Location Identifiers •

VAPOR WELL MONITORING

Hydrocarbon Vapor Detection • High Water Level Alarm •

GROUNDWATER MONITORING

Hydrocarbon Liquid Detection • Low Water Alarm •

SECONDARY CONTAINMENT VACUUM SENSING SYSTEM

(SCVS)

Vacuum Sensors •

AIR VAPOR MONITORING

In-Station Diagnostics (ISD) Optional Vapor Collection Monitor Optional Carbon Canister Vapor Polisher Optional Vapor Pressure Sensor Optional Vapor Flow Meter Optional

ALARMS

Leak • Overfill • High Level • Sudden Loss • High Water • Low Inventory • Programmable Alarm Limits •

125 Powder Forest Drive • PO Box 2003 • Simsbury, CT 06070 • ©2023 Veeder-Root • P/N 577014-455 Rev. B All information contained in this document is subject to change without notice.

veeder.com +1.800.873.3313

Notice

Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.

Veeder-Root shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this publication.

Veeder-Root reserves the right to change system options or features, or the information contained in this publication.

This publication contains proprietary information which is protected by copyright. All rights reserved. No part of this publication may be photocopied, reproduced, or translated to another language without the prior written consent of Veeder-Root.

Example Illustrations

Illustrations used in this guide for example sensor installations may contain components that are customer supplied and not included with the sensor. Please check with your Veeder-Root Distributor for recommended installation accessories.

Third Party Evaluations

Third party evaluations of the Veeder-Root sensors contained in this application guide can be found under the Veeder-Root vendor name on the National Work Group on Leak Detection Evaluations (NWGLDE) website:

http://www.nwglde.org

©2023 Veeder-Root. All rights reserved.

http://www.nwglde.org/

File details come from the government source that posted it. Updated .