This document package includes construction plans and specifications for a federal contract opportunity to renovate wing 4B at the Malcom Randall VAMC in Gainesville, Florida to accommodate a hemodialysis unit. The renovation work includes installation of corner guards, expansion joint details, a fire extinguisher cabinet, ductwork penetrations, transition strips, a roof curb detail, and mechanical ventilation components. Proposals are due by September 6, 2022 at 3:30 PM local time for solicitation number 36C24822R0158 issued by the Department of Veterans Affairs Veterans Health Administration VISN 8. Addendum 2 provides additional details and extends the proposal deadline. The project number is 573-18-601 and work will take place at the Malcom Randall VAMC located at 1601 SW Archer Rd in Gainesville, Florida.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S02 - AMENDMENT 0002 -36C24822R0158 0002.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CL
VINYL COVERED CORNER GUARD
SURFACE MOUNT, 2" WINGS OR
APPROVED EQUAL
SELF TAPPING SCREWS
NOTE:
CORNER GUARD PRODUCT:
INPRO 160, OR APPROVED EQUAL
2"
#8X1/2" WAFER HD TEK
SCREW 18"O.C.
CONTINUOUS EXTRUDED
FLEXBILE GASKET
CONTINUOUS
EXTRUDED ALUMINUM
FRAME
1"
BASIS OF DESIGN:
CONSTRUCTION SPECIALTIES
FCF-100
CONTINUOUS
EXTRUDED ALUMINUM
COVER PLAN
CONTINUOUS
EXTRUDED ALUMINUM
FRAME
3/16"X1 3/4" TAPPER 18" O.C.
FIRE BARRIER
2-HOUR UL
#FF-D-0044
STAINLESS STEEL
FOIL HEAT SHIELD
CONTINUOUS
EXTRUDED FLEXIBLE
GASKET
NONSHRINK GROUT
LEVELING BED AS
REQUIRED
CONTINUOUS
EXTRUDED ALUMINUM
COVER PLATE
1 11/16"
1"
1" 2 1/2"
1 13/16"
BASIS OF DESIGN:
CONSTRUCTION SPECIALTIES
GFPS-100
BASIS OF DESIGN:
CONSTRUCTION SPECIALTIES
FWF-100
CONTINUOUS EXTRUDED
FLEXIBLE GASKET
CONTINUOUS EXTRUDED
ALUMINUM FRAME
FRAME CONCEALED BY
FEATHERED JOINT
COMPOUND
WALL
#8X2" TEK SCREW
18"O.C.
1"
2 - 6" METAL C STUDS
5/8" GYP. BD.
SEMI-RECESSED FIRE EXTINGUISHER
CABINET. SIZE CABINET TO
ACCOMODATE A 2-1/2 GALLON
PRESSURIZED WATER EXTINGUISHER.
COORDINATE WALL OPENING WIDTH,
DEPTH & HEIGHT WITH MANUFACTURER
INSTALLATION INSTRUCTIONS.
ELEVATIO
N
NOTE: FIRE EXTINGUISHER CABINET
FURNISHED AND INSTALLED BY
CONTRACTOR. FIRE EXTINGUISHER IS
NOT INCLUDED IN THIS CONTRACT.
2'
- 3
" BASIS OF DESIGN:
TUB DIMENSIONS SHOWN ARE BASED ON
J.L. INDUSTRIES, INC., AMBASSADOR
SERIES, MODEL 2016
1' - 0"
3/
4"
2'
- 1
0"
FINISHED
FLOOR
PACK TIGHT WITH OAKUM, LEAD WOOL OR
FIBERGLASS ROPE
CAULK TIGHT WITH SILICONE.
COUNTER FLASHING
FLASHING
CAULK AROUND
ENTIRE PERIMETER
OF ALL FLASHING
DUCT (SEE MECHANICAL DRAWINGS FOR SIZE)
FLEXIBLE NON-COMBUSTIBLE
BLANKET INSULATION WITH
VAPOR BARRIER JACKET
(WHERE SPECIFIED)
EXTERIOR 3LB. GLASS
FIBER RIGID BOARD
INSULATION WITH
OUTDOOR VAPOR
BARRIER MASTIC.
(WHERE SPECIFIED)
EXTERIOR
JACKET
EXTERIOR WALL
4" WIDE ESCUTCHEON SHEET METAL
FLANGE AROUND ENTIRE DUCT
INTERIOR WALL
DOOR WHERE OCCURS
REDUCER STRIP -
REFER TO ROOM FINISH
SCHEDULE. JOHNSONITE
RRS-130-C , OR APPROVED
EQUAL
EXPOSED CONCRETE
FLOOR
LVT
TS-2
12" (MIN.)
LVT
EPOXY FLOORING
TRANSITION STRIP. SCHLUTER OR
APPROVED EQUAL
TS-1
LEVELING COMPOUND -
FEATHER DOWN TO FLOOR
ELEVATION
BRICK FACE
WELD ALL
JOINTS
OF DUCT
4"
WIDTH
4"
TO BACKING BLOCK WALL
3/8" S.S. ANCHOR BOLTS FASTEN
BLOCK WALL
ANGLE BRACKET (TYPICAL)
BASE AND
INTERPLY SHEETS
CAP SHEET
CANT STRIP AND
COVERBOARD
CAP SHEET
INTERPLY SHEET
EXISTING CONCRETE ROOF DECK
8" M
IN
PER MFR PER MFR
SET BOLT IN SEALANT
GASKET
SHEET METAL COVER
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
08/30/2022
ARCHITECTURAL - DETAILS RENOVATION OF WING 4B FOR
HEMODIALYSIS UNIT
1601 SW. ARCHER RD.
GAINESVILLE, FL 32608
CZ CR
573-18-601
AE505
BID DOCUMENTS
6" = 1'-0"
FINISH DETAIL - CORNER GUARD
0 1" 2" 3" 4"
6" = 1'-0"
EXPANSION JOINT DETAIL - CEILING
6" = 1'-0"
EXPANSION JOINT DETAIL - FLOOR
6" = 1'-0"
EXPANSION JOINT DETAIL - WALL
0 1" 2" 3" 4"
0 1" 2" 3" 4"
0 1" 2" 3" 4"
1 1/2" = 1'-0"5
TYPICAL RECESSED FIRE EXTINGUISHER CABINET
0 1' 1 1/2'1/2'
NOT TO
SCALE
EXTERIOR WALL DUCT PENETRATION DETAIL
12" = 1'-0"7
TYPICAL TRANSITION STRIP DETAILS
0 1/2" 1" 2"
3" = 1'-0"8
KNEE BRACE FOR HORIZONTAL DUCTWORK
0 6" 9"3"
Revisions: Date:
30% SCHEMATIC DESIGN 07/17/2020
65% DESIGN DEVELOPMENT 04/22/2021
95% CONSTRUCTION DOCUMENTS 06/16/2021
BID DOCUMENTS 07/28/2021
ADDENDUM 2 08/30/2022
3" = 1'-0"9
ROOF CURB DETAIL
0 6" 9"3"
345678
H
J
K
L
20x10 DN ALONG WALL
INTO CEILING OF
FOURTH FLOOR. SEE
SHEET MH101 FOR
CONTINUATION.
20x10
10x20 ON SIDE OF
BUILDING, ABOVE 5TH
FLOOR WINDOWS
20x10 UP
TO ROOF
105x60x24
PLENUM
F-176/177F-176/177
EF-177EF-177
1525 CFM
A. EXHAUST AIR DISCHARGE SHALL BE A MINIMUM OF 25 FEET FROM ANY OUTSIDE AIR INTAKE.
B. CLEARLY LABEL EVERY 50 FEET, ALL EXHAUST DUCTWORK SERVING ISOLATION ROOM SUITES AS
"COMMUNICABLE DISEASE CONTAMINATED AIR."
C. ALL EXHAUST DUCTWORK SERVING THE ISOLATION ROOM AND AIRLOCK ROOM (SHOWN HATCHED)
SHALL BE CONSTRUCTED OF MINIMUM 18 GAUGE ALL WELDED STAINLESS STEEL. REFER TO
SPECIFICATIONS SECTION 233100.
GENERAL MECHANICAL NOTES
1. BAG-IN/BAG-OUT HEPA FILTER. PROVIDE ALL MAINTENANCE AND SERVICE ACCESS PER
MANUFACTURER'S INSTRUCTIONS.
2. PROVIDE ALL MAINTENANCE AND SERVICE ACCESS PER MANUFACTURER'S INSTRUCTIONS.
3. EXHAUST DUCTWORK TO BE MOUNTED TO EXTERIOR WALL. REFER TO ARCHITECTURAL DRAWINGS
FOR MORE DETAIL.
MECHANICAL KEY NOTESX
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
08/30/2022
MECHANICAL VENTILATION - PARTIAL
ROOF PLAN
RENOVATION OF WING 4B FOR
HEMODIALYSIS UNIT
1601 SW. ARCHER RD.
GAINESVILLE, FL 32608
DG TH
573-18-601
MH102
BID DOCUMENTS
N
1/4" = 1'-0"
MECHANICAL VENTILATION - PARTIAL ROOF PLAN
0 2' 4' 8'
Revisions: Date:
65% DESIGN DEVELOPMENT 04/22/2021
95% CONSTRUCTION DOCUMENTS 06/16/2021
BID DOCUMENTS 07/28/2021
ADDENDUM #2 08/30/2022
| 18-122 Hemodialysis Architectural_crollinsBZDDY |
| 19530 VA Gainesville Hemodialysis MEP-R19_crollinsBZDDY |