57318601-Addendum NO.2 08302022.pdf

PDF 875 KB Posted

Attached to
Y1DA-- Project NO. : 573-18-601 BB - Renovate 4B for Hemodialysis
Solicitation number
36C24822R0158
Issued by

About this file

This document package includes construction plans and specifications for a federal contract opportunity to renovate wing 4B at the Malcom Randall VAMC in Gainesville, Florida to accommodate a hemodialysis unit. The renovation work includes installation of corner guards, expansion joint details, a fire extinguisher cabinet, ductwork penetrations, transition strips, a roof curb detail, and mechanical ventilation components. Proposals are due by September 6, 2022 at 3:30 PM local time for solicitation number 36C24822R0158 issued by the Department of Veterans Affairs Veterans Health Administration VISN 8. Addendum 2 provides additional details and extends the proposal deadline. The project number is 573-18-601 and work will take place at the Malcom Randall VAMC located at 1601 SW Archer Rd in Gainesville, Florida.

View the file

Other files

File Type Posted
S02 - AMENDMENT 0002 -36C24822R0158 0002.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CL

VINYL COVERED CORNER GUARD

SURFACE MOUNT, 2" WINGS OR

APPROVED EQUAL

SELF TAPPING SCREWS

NOTE:

CORNER GUARD PRODUCT:

INPRO 160, OR APPROVED EQUAL

2"

#8X1/2" WAFER HD TEK

SCREW 18"O.C.

CONTINUOUS EXTRUDED

FLEXBILE GASKET

CONTINUOUS

EXTRUDED ALUMINUM

FRAME

1"

BASIS OF DESIGN:

CONSTRUCTION SPECIALTIES

FCF-100

CONTINUOUS

EXTRUDED ALUMINUM

COVER PLAN

CONTINUOUS

EXTRUDED ALUMINUM

FRAME

3/16"X1 3/4" TAPPER 18" O.C.

FIRE BARRIER

2-HOUR UL

#FF-D-0044

STAINLESS STEEL

FOIL HEAT SHIELD

CONTINUOUS

EXTRUDED FLEXIBLE

GASKET

NONSHRINK GROUT

LEVELING BED AS

REQUIRED

CONTINUOUS

EXTRUDED ALUMINUM

COVER PLATE

1 11/16"

1"

1" 2 1/2"

1 13/16"

BASIS OF DESIGN:

CONSTRUCTION SPECIALTIES

GFPS-100

BASIS OF DESIGN:

CONSTRUCTION SPECIALTIES

FWF-100

CONTINUOUS EXTRUDED

FLEXIBLE GASKET

CONTINUOUS EXTRUDED

ALUMINUM FRAME

FRAME CONCEALED BY

FEATHERED JOINT

COMPOUND

WALL

#8X2" TEK SCREW

18"O.C.

1"

2 - 6" METAL C STUDS

5/8" GYP. BD.

SEMI-RECESSED FIRE EXTINGUISHER

CABINET. SIZE CABINET TO

ACCOMODATE A 2-1/2 GALLON

PRESSURIZED WATER EXTINGUISHER.

COORDINATE WALL OPENING WIDTH,

DEPTH & HEIGHT WITH MANUFACTURER

INSTALLATION INSTRUCTIONS.

ELEVATIO

N

NOTE: FIRE EXTINGUISHER CABINET

FURNISHED AND INSTALLED BY

CONTRACTOR. FIRE EXTINGUISHER IS

NOT INCLUDED IN THIS CONTRACT.

2'

- 3

" BASIS OF DESIGN:

TUB DIMENSIONS SHOWN ARE BASED ON

J.L. INDUSTRIES, INC., AMBASSADOR

SERIES, MODEL 2016

1' - 0"

3/

4"

2'

- 1

0"

FINISHED

FLOOR

PACK TIGHT WITH OAKUM, LEAD WOOL OR

FIBERGLASS ROPE

CAULK TIGHT WITH SILICONE.

COUNTER FLASHING

FLASHING

CAULK AROUND

ENTIRE PERIMETER

OF ALL FLASHING

DUCT (SEE MECHANICAL DRAWINGS FOR SIZE)

FLEXIBLE NON-COMBUSTIBLE

BLANKET INSULATION WITH

VAPOR BARRIER JACKET

(WHERE SPECIFIED)

EXTERIOR 3LB. GLASS

FIBER RIGID BOARD

INSULATION WITH

OUTDOOR VAPOR

BARRIER MASTIC.

(WHERE SPECIFIED)

EXTERIOR

JACKET

EXTERIOR WALL

4" WIDE ESCUTCHEON SHEET METAL

FLANGE AROUND ENTIRE DUCT

INTERIOR WALL

DOOR WHERE OCCURS

REDUCER STRIP -

REFER TO ROOM FINISH

SCHEDULE. JOHNSONITE

RRS-130-C , OR APPROVED

EQUAL

EXPOSED CONCRETE

FLOOR

LVT

TS-2

12" (MIN.)

LVT

EPOXY FLOORING

TRANSITION STRIP. SCHLUTER OR

APPROVED EQUAL

TS-1

LEVELING COMPOUND -

FEATHER DOWN TO FLOOR

ELEVATION

BRICK FACE

WELD ALL

JOINTS

OF DUCT

4"

WIDTH

4"

TO BACKING BLOCK WALL

3/8" S.S. ANCHOR BOLTS FASTEN

BLOCK WALL

ANGLE BRACKET (TYPICAL)

BASE AND

INTERPLY SHEETS

CAP SHEET

CANT STRIP AND

COVERBOARD

CAP SHEET

INTERPLY SHEET

EXISTING CONCRETE ROOF DECK

8" M

IN

PER MFR PER MFR

SET BOLT IN SEALANT

GASKET

SHEET METAL COVER

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

A

B

C

D

E

F

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Drawing Title

Approved: Project Director

Phase Project Title Project Number

Building Number

Drawing NumberLocation

Issue Date Checked Drawn

VA FORM 08-6231

FULLY SPRINKLERED

08/30/2022

ARCHITECTURAL - DETAILS RENOVATION OF WING 4B FOR

HEMODIALYSIS UNIT

1601 SW. ARCHER RD.

GAINESVILLE, FL 32608

CZ CR

573-18-601

AE505

BID DOCUMENTS

6" = 1'-0"

FINISH DETAIL - CORNER GUARD

0 1" 2" 3" 4"

6" = 1'-0"

EXPANSION JOINT DETAIL - CEILING

6" = 1'-0"

EXPANSION JOINT DETAIL - FLOOR

6" = 1'-0"

EXPANSION JOINT DETAIL - WALL

0 1" 2" 3" 4"

0 1" 2" 3" 4"

0 1" 2" 3" 4"

1 1/2" = 1'-0"5

TYPICAL RECESSED FIRE EXTINGUISHER CABINET

0 1' 1 1/2'1/2'

NOT TO

SCALE

EXTERIOR WALL DUCT PENETRATION DETAIL

12" = 1'-0"7

TYPICAL TRANSITION STRIP DETAILS

0 1/2" 1" 2"

3" = 1'-0"8

KNEE BRACE FOR HORIZONTAL DUCTWORK

0 6" 9"3"

Revisions: Date:

30% SCHEMATIC DESIGN 07/17/2020

65% DESIGN DEVELOPMENT 04/22/2021

95% CONSTRUCTION DOCUMENTS 06/16/2021

BID DOCUMENTS 07/28/2021

ADDENDUM 2 08/30/2022

3" = 1'-0"9

ROOF CURB DETAIL

0 6" 9"3"

345678

H

J

K

L

20x10 DN ALONG WALL

INTO CEILING OF

FOURTH FLOOR. SEE

SHEET MH101 FOR

CONTINUATION.

20x10

10x20 ON SIDE OF

BUILDING, ABOVE 5TH

FLOOR WINDOWS

20x10 UP

TO ROOF

105x60x24

PLENUM

F-176/177F-176/177

EF-177EF-177

1525 CFM

A. EXHAUST AIR DISCHARGE SHALL BE A MINIMUM OF 25 FEET FROM ANY OUTSIDE AIR INTAKE.

B. CLEARLY LABEL EVERY 50 FEET, ALL EXHAUST DUCTWORK SERVING ISOLATION ROOM SUITES AS

"COMMUNICABLE DISEASE CONTAMINATED AIR."

C. ALL EXHAUST DUCTWORK SERVING THE ISOLATION ROOM AND AIRLOCK ROOM (SHOWN HATCHED)

SHALL BE CONSTRUCTED OF MINIMUM 18 GAUGE ALL WELDED STAINLESS STEEL. REFER TO

SPECIFICATIONS SECTION 233100.

GENERAL MECHANICAL NOTES

1. BAG-IN/BAG-OUT HEPA FILTER. PROVIDE ALL MAINTENANCE AND SERVICE ACCESS PER

MANUFACTURER'S INSTRUCTIONS.

2. PROVIDE ALL MAINTENANCE AND SERVICE ACCESS PER MANUFACTURER'S INSTRUCTIONS.

3. EXHAUST DUCTWORK TO BE MOUNTED TO EXTERIOR WALL. REFER TO ARCHITECTURAL DRAWINGS

FOR MORE DETAIL.

MECHANICAL KEY NOTESX

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

A

B

C

D

E

F

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Drawing Title

Approved: Project Director

Phase Project Title Project Number

Building Number

Drawing NumberLocation

Issue Date Checked Drawn

VA FORM 08-6231

FULLY SPRINKLERED

08/30/2022

MECHANICAL VENTILATION - PARTIAL

ROOF PLAN

RENOVATION OF WING 4B FOR

HEMODIALYSIS UNIT

1601 SW. ARCHER RD.

GAINESVILLE, FL 32608

DG TH

573-18-601

MH102

BID DOCUMENTS

N

1/4" = 1'-0"

MECHANICAL VENTILATION - PARTIAL ROOF PLAN

0 2' 4' 8'

Revisions: Date:

65% DESIGN DEVELOPMENT 04/22/2021

95% CONSTRUCTION DOCUMENTS 06/16/2021

BID DOCUMENTS 07/28/2021

ADDENDUM #2 08/30/2022

18-122 Hemodialysis Architectural_crollinsBZDDY
19530 VA Gainesville Hemodialysis MEP-R19_crollinsBZDDY

File details come from the government source that posted it. Updated .