3d RLP amendment 2.pdf
PDF 900 KB Posted
- Solicitation number
- 57-05135-23-FA-A
About this file
This document is a Request for Lease Proposals (RLP) amendment for the USDA to lease office and related space in Ash Flat, AR. The amendment adds requirements for the Lessor to provide Electric Vehicle Supply Equipment (EVSE) infrastructure to support two dual-port Level 2 EVSE charging stations.
The solicitation number is 57-05135-23-FA-A, and the due date for offers is September 10, 2024 at 5:00 PM CST. The procurement is being conducted by the USDA Farm Production and Conservation (FPAC) agency. The RLP provides detailed requirements for the office space layout, room descriptions, physical security features, and other tenant improvement items to be included in the Lessor's cost. The Government requires 4,796 to 5,036 ABOA square feet of space, with a maximum of 5,756 RSF. Four (4) reserved parking spaces for government vehicles and 31 unreserved spaces for employees and customers are also needed.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RLP amendment 1.pdf | ||
| AR Ash Flat RLP Package 9 20 2023.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Except as provided herein, all terms and conditions in the solicitation remain unchanged and in full effect
II. ACKNOWLDEGEMENT OF AMENDMENT
I n l i e u o f o t he r w r i t t en m e t h od s o f ac k n ow l ed g em e n t , t h e o f f e r o r m ay c om p l e t e B l oc k 9 an d 10 an d r e t u r n t h i s am e ndm e n t t o t h e a dd r es s i n B l oc k 5 .
9. NAME AND ADDRESS OF OFFEROR 10A. OFFEROR (Signature of person authorized to sign)
10B. NAME OF SIGNER
10C. TITLE OF SIGNATURE
10D. DATE
AUTHORIZED FOR LOCAL REPRODUCTION OPTIONAL FORM 309 (9-97)
Prescribed by GSA – FAR (48 CFR) 53.215-1(g)
AMENDMENT OF SOLICITATION
(Negotiated Procurements)
PAGE of PAGES
1 1
NOTICE: O f fe ro rs mus t acknowledge rece ip t o f th i s amendment i n wr i t i ng by the da te and t ime spec i f i ed fo r p roposa l submiss ions o r the da te and t ime spec i f i ed i n B lock 6 , wh ichever i s l a te r . IF YOUR ACKNOWLEDGEMENT IS NOT RECEIVED AT THE DESIGNATED LOCATION BY THE SPECIFIED DATE AND T IME, YOUR OFFER MAY BE REJECTED. I f by v i r tue o f th i s amendment you w ish to change your o f fe r , such change mus t make re fe rence to the so l i c i t a t i on and th i s amendment and be rece i ved p r i o r to the da te and t ime spec i f ied i n B lock 6 .
I. AMENDMENT
1. SOLICITATION NUMBER 2. SOLICITATION DATE 3. AMENDMENT NUMBER 4. AMENDMENT DATE
57-05135-23-FA 9/20/2023 2 9/3/2024
5. ISSUED BY 6. DUE DATE
Jessica Kata USDA Lease Contracting Officer
THIS AMENDMENT DOES NOT CHANGE THE DATE BY WHICH OFFERS ARE
DUE UNLESS A DATE AND TIME IS INSERTED BELOW
A. DATE B. TIME
9/10/2024 5:00 PM CST
7. FOR INFORMATION CALL (No collect calls)
A. NAME B. TELEPHONE C. EMAIL ADDRESS
Caden Fox
AREA CODE PHONE NUMBER
caden.fox@usda.gov 615 277-2670
8. DESCRIPTION OF AMENDMENT
This amendment is to add section F to the Agency Specific Requirements where updated Electric Vehicle charging infrastructure requirements can be found. Updated offers are due 9/10/2024 ar 5:00pm.
------------------------------------------------------------------- END OF RLP CHANGES --------------------------------------------------------------------
SOLICITATION NO. 57-05135-23-FA
AGENCY SPECIFIC REQUIREMENTS
PAGE 1 LESSOR: ______ GOVERNMENT: ________ FPAC
EXHIBIT- B
Agency Specific Requirements
Solicitation Number: 57-05135-23-FA Sharp County, Ash Flat, AR
The Agency Specific Requirements (ASRs) do not reduce the minimum requirements contained within the Lease. These ASRs provides specific agency requirements, which may be complementary, more specific, or more stringent than those of the Lease minimum requirements. To the extent the contents of these ASRs conflict with the contents of the Lease, the more stringent requirement shall apply.
A. ROOM SCHEDULE
The following spaces in these approximate sizes shall be provided by the Lessor.
TOTAL USDA PERSONNEL: 13 8 21
FSA NRCS
SPACE TYPE
SQUARE
FOOTAGE
NEEDED
8 PRIVATE OFFICES (120 sf each +/-) 840 120 960 OPEN OFFICE AND CIRCULATION AREA (13 workstations/3 touch-down stations)
516 570 2456
CONFERENCE ROOM 186 114 300
BREAK ROOM 93 57 150
RECEPTION AREA 93 57 150
MAIL/COPY AREA 93 57 150
ADP ROOM 62 38 100
CONSULTATION/HUDDLE ROOM 50 30 80
STORAGE ROOM 300 150 450
MINIMUM ABOA (Space Used by USDA Only): 4796 MAXIMUM ABOA (Space Used by USDA Only): 5036
MAXIMUM RSF (Rentable Square Footage includes common areas such as bathrooms, utility rooms, vestibules, and other space shared with non-USDA tenants):
Government Vehicle Reserved Parking Needed: 4 Employee/Customer Unreserved Parking Needed: 31
Wareyard Space Needed: 0 2000 2000 Exterior Storage 0 200 200
PAGE 2 LESSOR: ______ GOVERNMENT: ________ USDA FPAC
B. ROOM DESCRIPTIONS
Lobby/Reception Area – The lobby area is designed for customers to enter, check in, and wait to be seen by USDA staff.
1. Electrical outlets according to local code.
2. Flooring, wall coverings, and window coverings according to Lease.
3. See Physical Security requirements below for additional information.
Design Examples:
Private Offices- Private offices shall be designed to accommodate (1) one individual seated at a desk, with space for (2) two additional guests. These spaces are to be utilized by individuals who require acoustic and visual privacy for meetings and phone calls or tele/video conferencing. Interior glass window with blinds to provide visibility to the open office and allow daylight to penetrate through.
1. Sound Transmission Class rating as specified in Lease.
2. Greater of three (3) double electrical outlets or local code.
3. Two (2) telecommunication outlet.
4. Three (3) coat hooks on the wall next to the door.
5. Flooring, wall coverings, and window coverings according to Lease.
PAGE 3 LESSOR: ______ GOVERNMENT: ________ USDA FPAC
Design Example:
Consult Room – Consult rooms shall be designed to seat up to 4 individuals for hosting small meetings, phone calls, tele/video conferencing, or for individual working. Locate adjacent to workstation clusters and in close proximity to enclosed offices. When possible, provide access to natural daylight. Interior glass window with blinds to provide visibility to the open office and allow daylight to penetrate through. Provide film at seated height for partial privacy.
2. Greater of five (5) double electrical outlets or local code.
3. Two (2) telecommunication outlet.
4. Three (3) coat hooks on the wall next to the door.
5. Flooring, wall coverings, and window coverings according to Lease.
PAGE 4 LESSOR: ______ GOVERNMENT: ________ USDA FPAC
Conference Room - Meeting rooms for 10-12 people for large meetings, tele/video-conferencing, as well as presentations. Locate centrally within the office and adjacent to the reception/service desk in order to provide immediate access for invited guests. Ideally, locate close to the break area for convenience for invited guests. Consider locating doors off of the open office area for acoustic privacy. Provide access to daylight when possible.
2. Greater of five (5) double electrical outlets or local code.
3. One (1) or Two (2) telecommunication floor boxes.
4. Lessor to provide data jack and audio-visual (A/V) connection for installation of a wall mounted television to use for presentations. Lessor is responsible for maintenance of connections/wiring and data jack, but television is the property of USDA and is to be installed and maintained by
USDA.
5. Six (6) coat hooks on the wall next to the door.
6. Flooring, wall coverings, and window coverings according to Lease.
Design Example
PAGE 5 LESSOR: ______ GOVERNMENT: ________ USDA FPAC
Break Room - An enclosed or semi-enclosed space to serve as a destination for refreshment. The space is provisioned to support food preparation and storage, coffee machines and recycle bins. Depending on size of office this may be an area for socialization, so seating area should be provided. Locate adjacent to conference room. Some enclosure is necessary to reduce transmission of noise and smells into the workplace.
2. Greater of four (4) double electrical outlets or local code, in addition to the outlets required for refrigerator/freezer and microwave. Outlets provided at counter per local code.
3. Six (6) coat hooks on the wall next to the door.
4. Flooring, wall coverings, and window coverings according to Lease.
5. Lessor to provide and maintain, as part of operations and maintenance of the Premises, a breakroom refrigerator with freezer (at least 18 cu ft in size) and countertop microwave oven. The Lessor shall retain ownership of these items, and associated costs shall be included in Operating Expenses on the Form 1217.
6. Minimum of ten (10) feet of counter with base and overhead cabinets and double compartment sink.
PAGE 6 LESSOR: ______ GOVERNMENT: ________ USDA FPAC
Secure Storage – This room is for equipment or other content that needs to be securely stored, but easily accessible within the office. Size and type of storage units will vary depending on content requirements.
1. Room shall not be accessible through the ceiling to prevent “up and over” access. Utilize slab-to-slab walls or installation of steel mesh to prevent intrusion.
2. Solid core door with door hinges installed inside the room. No windows or other openings.
3. Fire extinguisher required.
4. Sound Transmission Class rating as specified in Lease.
5. Greater of three (3) double electrical outlets or local code.
6. Flooring and wall coverings according to Lease.
Open Office - A standard space for an individual to accomplish focused solo work and short-term collaborative work who spend most of their time at their desk. Individual workstations are provided in combination with easily accessible meeting spaces for group work and focus booths for concentration or private conversation. Place near floor perimeter to maximize access to natural light.
Generally, this is open space where systems (cubicle) furniture will be installed by USDA. Lessor must ensure electrical and data connections are available to hard wire the installed furniture, and Lessor is responsible for providing an electrician to undertake or assist with the furniture installation. Data and electrical can be provided via ceiling drops or wall connections.
PAGE 7 LESSOR: ______ GOVERNMENT: ________ USDA FPAC
Mud Room - The Mud Room includes a shower area of approximately 120sf for cleaning and washing field equipment. The room should provide complete visual and acoustic privacy and shall be located away from open offices areas. Recommend locating adjacent to a point of entry, to limit path of travel through office. Locate near lavatories or existing plumbing.
2. Electrical outlets per local code.
3. Three (3) coat hooks on the wall next to the door.
4. Flooring, wall coverings, and window coverings according to Lease.
PAGE 8 LESSOR: ______ GOVERNMENT: ________ USDA FPAC
C. REQUIRED FEATURES NOT INCLUDED IN SHELL COSTS: For all of these items, purchase and installation should be included in the Lessor’s Tenant Improvement costs and ongoing maintenance should be an Operating Cost included on GSA Form 1217.
1. Lessor to install and maintain all Telecommunication Requirements (development of ADP Room, CAT wiring, etc.) as outline in Lease Exhibit G.
2. If the US Postal Service will not deliver and pick up mail from each USDA agency inside the Premises, then the Lessor is required to provide and maintain separate mailboxes for each USDA agency in the Premises. The mailboxes must be lockable and acceptable to both USDA and USPS. The incoming mailboxes must be of sufficient size to accept a single package of 9” wide x 11 ½” deep x 12” high, or a separate common oversized mailbox of that minimum size must be provided. A separate outgoing mailbox capable of holding outgoing parcel of a minimum of 9” wide x 11 ½” deep x 12” high must also be provided by Lessor. Location and design must be approved by LCO or designated representative.
3. Lessor to install and maintain a through-the-wall locking depository drop box. Drop box should be secure and provide the ability for receipt of documents from exterior of building without entering interior areas of the building. Location and design must be approved by LCO or designated representative.
4. Lessor to provide and maintain signage as outlined in USDA Facility Signage Guide as furnished by the Government.
i. The monument sign must be such that the sign is visible from both directions of traffic.
ii. Sign locations and design must be approved by LCO or designated representative.
iii. Should the location of the leased Premises not be evident to customers parking in the parking lot, the Lessor shall install and maintain directional or wayfinding signage from the parking area to the Premises.
5. Lessor to Install and maintain fire extinguishers, smoke detectors, carbon monoxide detectors, and automated external defibrillator (AED).
6. Lessor to provide and maintain approximately 2,000 SF of secured ware-yard to accommodate 4 GOV’s, 2 trailers, 2 ATV’s/UTV’s. Lessor to provide and maintain approximately 200 square feet (10 foot x 20 foot structure) of exterior storage for equipment at the Premises.
7. New paint is required, and the lessor is responsible for moving office furniture and returning it to the correct place upon completion.
8. New flooring is required, and the lessor is responsible for moving office furniture and returning it to the correct place upon completion.
D. REQUIRED FEATURES TO BE INCLUDED IN SHELL COSTS: Lessor shall include the costs associated with these features in Shell Rent.
1. The leased Premises must comply with accessibility requirements set forth in Section
3.15 of Lease at the time of lease commencement. Lessor must correct the following accessibility related deficiencies prior to lease commencement:
PAGE 9 LESSOR: ______ GOVERNMENT: ________ USDA FPAC
2. Lessor to provide an exterior area large enough for an 8 foot by 10-foot storage shed at the Premises. USDA will provide, maintain, and retain ownership of the shed. Lessor shall note that USDA may store gasoline for ATV use, and the location of the shed must meet all local building codes and required set-backs. Shed location to be coordinated with and approved by LCO or designated representative.
3. Lessor to provide 2,000 Square feet Ware yard that meets local code and USDA level 1 security requirements found in Exhibit E.
E. PHYSICAL SECURITY REQUIREMENTS: In addition to the specifications set forth in Section
7.01 of the Lease, the Lessor is required to implement the following USDA-specific physical security features in the Premises. For all of these items, purchase and installation should be included in the Lessor’s Tenant Improvement costs and ongoing maintenance should be an Operating Cost included on GSA Form 1217.
REQUIREMENT DESCRIPTION
Hardened Public- Government Space Separation
A Hardened Customer Service Counter or Service Window shall be installed to separate the public lobby area from employee workspace. It shall be designed in a way that customers cannot access USDA space (on the other side of the counter) unless permitted entry through a locked door.
This counter must be a hardened barrier that requires employees to enter through a locked door to enter from the public side of the counter into USDA employee space. The door must have a lock and remain secured at all times. The counter shall be 42” to 48’’ high, but must also account for an Architectural Barriers Act Accessibility Standard (ABAAS) Compliance area.
Entrance Door Chime An entrance door chime shall be installed on the main/customer entrance to notify employees when a visitor enters the facility.
Intrusion Detection System (IDS) Coverage and Monitoring
The lessor shall design, install, and maintain an Intrusion Detection System (IDS) consisting of door contacts for all perimeter entry and exit doors to USDA space;
magnetic contacts for operable ground floor windows, acoustic glass break detectors for glass doors, doors with glass windows, or ground level windows;
passive infrared motion sensors (if needed); an alarm keypad (one needed per office suite); and an auto-dialer for alarms to annunciate to a monitoring service (i.e. DHS Alarm MegaCenter, local police station, or approved 3rd party monitoring service).
Duress/Panic Buttons All USDA Main Entrance/Reception areas shall have a duress/panic alarm installed. Additional duress/panic buttons shall be placed in areas where employees routinely service customers.
These alarms shall be tied into the IDS system to ensure annunciation to a monitoring service (i.e. DHS Alarm MegaCenter, local police station, or approved 3rd party monitoring service).
PAGE 10 LESSOR: ______ GOVERNMENT: ________ USDA FPAC
Main/Customer Entrance Emergency Lockdown
A locking device is required on the main/customer entrance that will easily allow for locking/unlocking the door in emergencies. To support an emergency lockdown, a thumb turn deadbolt shall be installed on the main entrance door so the door can be locked immediately in an emergency. Another acceptable option is installing an electronic lock that has an emergency lock-down button at the service counter.
Space Compartmentalization / False Ceiling
Any suspended (false) ceilings that lead into USDA-FPAC space from a wall in a common hallway or other tenants space must be secured in a manner that no individual can enter USDA space undetected or unmonitored by exploiting the gap above the false ceiling wall. The preferred method of securing the space is to install “slab to slab” walls that separate the USDA space from the rest of the facility
Perimeter Doors and Door Locks
Perimeter doors to USDA space must be either glass storefront doors, metal high-security doors, or solid-core wood doors. Hollow core doors are not permissible.
Door hinges must be located on the inside of the door (non-public side) or exposed door hinge pins must be permanently secured to prevent removal.
Approved methods include tack welding or locking screws to hold pin in place.
Perimeter door locks must be either electronic access control, high security cipher, or high-security mechanical locks, preferably with a dead-bolt. Cipher or electronic access locks are highly encouraged to avoid the need to issue keys.
All exposed door locking mechanisms, except for deadbolts, must be covered by a door strike plate cover to prevent the mechanism from tampering.
The lessor is required to rekey all door locks prior to USDA leasing the space and all keys must be accounted for on a sign-out log.
Emergency Exit Doors Emergency exits doors shall include an automatic door closer and exit hardware that is compliant with applicable life safety codes and standards. All emergency exits doors shall have signage posted on the interior side of the door stating, “Emergency Exit Only”. These doors shall not be used for employee or tenant convenience.
A peephole shall be installed in the exit door, if an exterior window is not adjacent to the door or if it is not a glass door.
Emergency Exit doors shall have no visible hardware on the exterior.
REQUIREMENT DESCRIPTION
Window Air- Conditioning (A/C) Unit Protection
If applicable, if window A/C units are installed, they must be secured with a lockable cage or window bars in a way that prevents the window unit from being pushed in or removed.
PAGE 11 LESSOR: ______ GOVERNMENT: ________ USDA FPAC
Protection of Exterior Gas Mains or Propane Tanks Adjacent to Premises
If applicable, exposed gas mains or propane tanks near a facility façade or in a parking lot must have bollards (typically yellow safety bollards) or some other barrier (i.e., boulder) around it to protect it from a vehicle strike.
Security of Exterior Electrical Panels and Switches
If applicable, exterior electrical panels on the outside of the building or in common/public space shall be secured via a locking device, unless not permitted by local code. The preferred location for electrical panels is inside the USDA space or in a secured area on the interior of the building.
Public Restroom Access
Lessor must secure public restrooms (restrooms located in the building common area) in a manner that only facility tenants can access them and not the general public. This can be done by securing the restrooms with either a hard key or an access code.
Fire and Carbon Monoxide Detection-
Lessor shall install appropriate amount and type of smoke and carbon monoxide detection devices in accordance with local code.
Janitorial and Maintenance Staff Access
Any lessor provided maintenance/janitorial staff must undergo a Special Agreement Check (SAC) background investigation before being granted unescorted access. This check will be conducted by USDA-FPAC HSD. USDA- FPAC reserves the right to request daytime cleaning in USDA space. SAC background checks may be requested by the State Office through ServiceNow, routing the ticket to Homeland Security Division.
Perimeter Lighting
The Building Owner shall ensure exterior entrances/exits are illuminated to a minimum of 5 foot-candles; Sidewalks and walkways illuminated to a minimum of 3 foot-candles; and Parking lot surfaces illuminated to 1 foot-candle throughout the parking areas. Lessor shall have a lighting preventative maintenance plan in place to inspect perimeter lighting for broken fixtures or burnt-out bulbs and service any non-operable lights within 30 days.
F. EVSE REQUIREMENTS (TO BE INCLUDED IN TENANT IMPROVEMENT COSTS):
The Lessor shall provide Electric Vehicle Supply Equipment (EVSE) supporting infrastructure for Charging Station(s) and reserved parking spaces for electric vehicles. Infrastructure shall comply with all local electrical codes, and if none, the National Electrical Code (current edition).
1. Install the supporting infrastructure for two (2) dual-port Level 2 EVSE Charging Stations in support of USDA’s electric vehicles.
2. USDA, or designated contractor, will furnish, install, and maintain dual-port Level 2 EVSE
Charging Stations with SAE J1772 connectors and networked software systems for remote management to monitor, maintain, and allow access.
3. Lessor shall obtain all required permits for the installation and construction of supporting infrastructure of the EVSE Charging Station(s).
PAGE 12 LESSOR: ______ GOVERNMENT: ________ USDA FPAC
4. Lessor shall complete all requirements with special emphasis on the following required improvements:
a. Install conduit and all other required base-building electrical infrastructure necessary to support electric service to USDA’s EVSE Charging Station(s) at a location approved by the USDA.
b. Dedicated single-phase electrical circuit(s) (32A at 208/240V).
c. A dual pole 40A circuit breaker(s) at the electrical panel is required for each charging station. (e.g., 2 charging stations, 2 40 Amp Circuit Breakers).
d. Conductor wiring sized in accordance with the National Electrical Code requirement for 125% capacity for continuous load for all branch circuits from panel to stations via raceway or conduit with required grounding conductor.
e. For pedestal mount stations prepare pad and a minimum 36” coiled wiring remains above conduit stub for station connection.
f. Location must have a consistent cellular signal for networked station use.
5. Install bollards protecting stations and signage identifying that the EVSE is for USDA EGOV use only.