I cannot provide a summary of this file because the document content is not accessible to me. While the metadata indicates this is a Lease Proposal (RLP) Package related to GSA Real Property (likely a federal lease opportunity based on the naming convention), I do not have the actual text or detailed contents of the PDF to analyze and extract the specific information you requested, such as products or services required, response dates, award dates, pricing terms, set asides, agencies involved, or other salient details.

To provide an accurate summary, I would need direct access to the file's contents.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GSA TEMPLATE R103 (5/25)

GSA REQUEST

FOR LEASE

PROPOSALS

NO. 57-28033-26-

NR

Hernando- Nesbit, MS

Offers due by 08/29/2026

In order to be considered for award, offers conforming to the requirements of the RLP shall be received no later than 4PM Est on the date above. See “Receipt Of Lease Proposals” herein for additional information.

This Request for Lease Proposals ("RLP") sets forth instructions and requirements for proposals for a Lease described in the RLP documents. Proposals conforming to the RLP requirements will be evaluated in accordance with the Basis of Award set forth herein to select an Offeror for award. The Government will award the Lease to the selected Offeror, subject to the conditions herein.

The information collection requirements contained in this Solicitation/Contract, that are not required by regulation, have been approved by the Office of Management and Budget pursuant to the Paperwork Reduction Act and assigned the OMB Control No.

3090-0086.

SMALL RLP

TABLE OF CONTENTS

SECTION 1 - STATEMENT OF REQUIREMENTS 1

1.01 GENERAL INFORMATION (SMALL) (OCT 2023)

1.02 AMOUNT AND TYPE OF SPACE AND LEASE TERM (SLAT) (OCT 2020)

1.03 NORTH AMERICAN INDUSTRY CLASSIFICATION SYSTEM (NAICS) CODE AND SMALL BUSINESS SIZE STANDARD (OCT 2023) 1

SECTION 2 - SOLICITATION PROVISIONS

2.01 INCORPORATED SOLICITATION PROVISIONS (SMALL) (OCT 2024)

2.02 FLOOD PLAINS (OCT 2022)

SECTION 3 - ELIGIBILITY AND PREFERENCES FOR AWARD

3.01 BASIS OF AWARD (OCT 2023)

3.02 SEISMIC SAFETY – MODERATE SEISMICITY (MAY 2025)

3.03 SEISMIC SAFETY – HIGH SEISMICITY (MAY 2025)

3.04 ENERGY INDEPENDENCE AND SECURITY ACT (SMALL) (MAY 2025)

3.05 NATIONAL HISTORIC PRESERVATION ACT REQUIREMENTS – RLP (SMALL) (OCT 2023)

3.06 HUBZONE SMALL BUSINESS CONCERN PRICE PREFERENCE WAIVER (SMALL) (OCT 2023)

SECTION 4 - HOW TO OFFER

4.01 RECEIPT OF LEASE PROPOSALS (SMALL) (OCT 2023)

4.02 PROPOSAL CONTENTS FOR SMALL LEASES (OCT 2024)

4.03 FIRE PROTECTION AND LIFE SAFETY SUBMITTALS (SMALL) (OCT 2020)

4.04 EISA SUBMITTALS (SMALL) (SEP 2015)

4.05 SWING SPACE - RLP (OCT 2022)

RLP NO.57-28033-26-NR PAGE 1 GSA TEMPLATE R103 (10/24)

SECTION 1 - STATEMENT OF REQUIREMENTS

1.01 GENERAL INFORMATION (SMALL) (OCT 2023)

A. This Request for Lease Proposals (RLP) sets forth instructions and requirements for proposals for a Lease described in the RLP documents.

The Government will evaluate proposals conforming to the RLP requirements in accordance with the Basis of Award set forth below to select an Offeror for award. The Government will award the Lease to the selected Offeror, subject to the conditions below.

B. Included in the RLP documents are the GSA Form 3626 (U.S. GOVERNMENT LEASE FOR REAL PROPERTY (Short Form)) which serves as an offer form and lease contract award document Supplemental Lease Requirements document, and GSA 3517A, General Clauses.

C. The Offeror's executed GSA Form 3626 shall constitute a firm offer. No Lease shall be formed until the Lease Contracting Officer (LCO) executes the GSA Form 3626 and delivers a signed copy to the Offeror.

D. Offeror may not use Federal agency name(s) and/or acronym(s), e.g., General Services Administration, GSA, in the entity name that owns and/or leases the Space to GSA.

1.02 AMOUNT AND TYPE OF SPACE AND LEASE TERM (SLAT) (OCT 2020)

The Space shall be located in a modern quality Building of sound and substantial construction with a facade of stone, marble, brick, stainless steel, aluminum or other permanent materials in good condition and acceptable to the LCO. If not a new Building, the Space offered shall be in a Building that has undergone, or will complete by occupancy, modernization, or adaptive reuse for the Space with modern conveniences.

CITY, STATE HERNANDO-NESBIT, MS

DELINEATED AREA CITY LIMITS

SPACE TYPE(S) OFFICE

MINIMUM SQ. FT. (ABOA) 2349

MAXIMUM SQ. FT. (ABOA) 2467

RESERVED PARKING SPACES (TOTAL) 2819

RESERVED PARKING SPACES (SURFACE) 2

INITIAL FULL TERM 15 YEARS

TERMINATION RIGHTS 120

INITIAL FIRM TERM 5 YEARS

OPTION TERM 10 YEARS

ADDITIONAL REQUIREMENTS WAREYARD FOR 2 GOVERNMENT VEHICLES

1.03 NORTH AMERICAN INDUSTRY CLASSIFICATION SYSTEM (NAICS) CODE AND SMALL BUSINESS SIZE STANDARD (OCT 2023)

A. The North American Industry Classification System (NAICS) code for this acquisition is 531120 (Exception).

B. The small business size standard for the applicable NAICS code is found at HTTPS://WWW.SBA.GOV/DOCUMENT/SUPPORT-TABLE-SIZE-

STANDARDS STANDARDS.

https://www.sba.gov/document/support-table-size-standards https://www.sba.gov/document/support-table-size-standards

RLP NO. 57-28033-26-NR, PAGE 2 GSA TEMPLATE R103 (5/25)

SECTION 2 - SOLICITATION PROVISIONS

2.01 INCORPORATED SOLICITATION PROVISIONS (SMALL) (OCT 2024)

GSA 3516A, SOLICITATION PROVISIONS (For Simplified Acquisition of Leasehold Interests in Real Property) are attached to this RLP.

2.02 FLOOD PLAINS (OCT 2022)

A. A Lease will not be awarded for any offered Property located within a 1-percent-annual-chance floodplain (formerly referred to as 100-year floodplain) unless the Government has determined that there is no practicable alternative. An Offeror may offer less than its entire site in order to exclude a portion of the site that falls within a floodplain, so long as the portion offered meets all the requirements of this RLP and does not impact the Government’s full use and enjoyment of the Premises. If an Offeror intends that the offered Property that will become the Premises for purposes of this Lease will be something other than the entire site as recorded in tax or other property records the Offeror shall clearly demarcate the offered Property on its site plan/map submissions and shall propose an adjustment to property taxes on an appropriate pro rata basis. For such an offer, the Government may determine that the offered Property does not adequately avoid development in a 1-percent-annual-chance floodplain.

B. In addition, a Lease will not be awarded for any offered Property adjacent to 1-percent-annual-chance floodplain, where such an adjacency would, as determined by the Government, restrict ingress or egress to the Premises in the event of a flood, unless there is no practicable alternative.

RLP NO.57-28033-26-NR PAGE 3 GSA TEMPLATE R103 (10/24)

SECTION 3 - ELIGIBILITY AND PREFERENCES FOR AWARD

3.01 BASIS OF AWARD (OCT 2023)

A. Lowest Price Technically Acceptable Approach. The Lease will be awarded to the responsible Offeror whose offer conforms to the requirements of this RLP and Lease documents and is the lowest priced technically acceptable offer submitted, based on the lowest price per square foot, according to the ANSI/BOMA Z65.1-2017 definition for Occupant Area, which means “the total aggregated area used by an Occupant before Load Factors are applied, consisting of Tenant Area and Tenant Ancillary Area.” The Method A – Multiple Load Factor Method shall apply.

B. Price evaluation will be based on the lowest price per square foot, according to the ANSI/BOMA Z65.1-2017 definition for Occupant Area, which means “the total aggregated area used by an Occupant before Load Factors are applied, consisting of Tenant Area and Tenant Ancillary Area.” The Method A – Multiple Load Factor Method shall apply.

C. See FAR Clause 52.219-4 Notice of Price Evaluation Preference for HUBZone Small Business Concerns, as listed under the attached GSA

3517A, General Clauses.

D. If an offer contains terms taking exception to or modifying any Lease provision, the Government will not be under any obligation to award a

Lease in response to that offer.

3.02 SEISMIC SAFETY – MODERATE SEISMICITY (MAY 2025)

In accordance with the Earthquake Hazards Reduction Act of 1977, the following apply:

A. The Government intends to award a Lease to an Offeror of a Building that is in compliance with the Seismic Standards. If an offer is received which is in compliance with the Seismic Standards and the other requirements of this RLP, then other offers which do not comply with the Seismic Standards will not be considered. If none of the offers is in compliance with the Seismic Standards, the LCO will make the award to the Offeror whose offer meets the other requirements of this RLP and provides the best value to the Government, taking into account price, seismic safety and any other evaluation factors specified in this RLP.

B. An offered Building will be considered to be in compliance with the Seismic Standards if it meets one of the following conditions:

1. The offer includes a representation that the Building will have less than 10,000 ABOA SF of Space leased to the Federal Government upon commencement of the lease term (Seismic Form D),

2. The offer includes a Seismic Certificate certifying that the Building is a Benchmark Building (Seismic Form A).

3. The offer includes a Seismic Certificate based on a Tier I Evaluation showing that the Building meets the Seismic Standards (Seismic

Form B). The submission must include the checklists and backup calculations from the Tier 1 Evaluation.

4. The offer includes a Seismic Certificate based on a Tier 2 or Tier 3 Evaluation showing that the Building complies with the Seismic

Standards (Seismic Form B). If the certificate is based on a Tier 2 or Tier 3 Evaluation, the data, working papers, calculations and reports from the evaluation must be made available to the Government.

5. The offer includes a commitment to retrofit the Building to satisfy all of the Basic Safety Objective requirements of ASCE/SEI 41 (Seismic

Form C, Part 1). If the Offeror proposes to retrofit the Building, the offer must include a Tier 1 report with all supporting documents, a narrative explaining the process and scope of retrofit, and a schedule for the seismic retrofit. The Offeror shall provide a construction schedule, concept design for the seismic upgrade, and supporting documents for the retrofit, including structural calculations, drawings, specifications, and geotechnical report to the Government for review and approval prior to award. The documentation must demonstrate the seismic retrofit will meet the seismic standards and be completed within the time frame required.

6. The offer includes a pre-award commitment to construct a new Building, using local building codes (Seismic Form C, Part 2).

C. The LCO may allow an Offeror to submit a Seismic Certificate after the deadline for final proposal revisions. However, the LCO is not obligated to delay award in order to enable an Offeror to submit a Seismic Certificate.

D. Definitions. For the purpose of this paragraph:

1. “ASCE/SEI 31” means the American Society of Civil Engineers standard, Seismic Evaluation of Existing Buildings. You can purchase

ASCE/SEI from ASCE at (800) 548-2723 or by visiting HTTP://WWW.ASCE.ORG/PUBLICATIONS/.

2. “ASCE/SEI 41” means American Society of Civil Engineers standard, Seismic Rehabilitation of Existing Buildings. You can purchase

ASCE/SEI from ASCE at (800) 548-2723 or by visiting HTTP://WWW.ASCE.ORG/PUBLICATIONS/.

3. “Benchmark Building” means a building that was designed and built, or retrofitted, in accordance with the seismic provisions of the applicable codes specified in Section 1.3.1 of RP 8.

4. Engineer” means a professional engineer who is licensed in Civil or Structural Engineering and qualified in the structural design of buildings. They must be licensed in the state where the property is located.

http://www.asce.org/publications/

RLP NO.57-28033-26-NR PAGE 4 GSA TEMPLATE R103 (10/24)

5. “RP 8” means “Standards of Seismic Safety for Existing Federally Owned and Leased Buildings ICSSC Recommended Practice 8 (RP 8),” issued by the Interagency Committee on Seismic Safety in Construction as ICSSC RP 8 and the National Institute of Standards and Technology as NIST GCR 11-917-12. RP 8 can be obtained from HTTPS://WWW.NIST.GOV/PUBLICATIONS/

6. “Seismic Certificate” means a certificate executed and stamped by an Engineer on the appropriate Certificate of Seismic Compliance form included with this RLP together with any required attachments.

7. “Seismic Standards” means the requirements of RP 8 Section 2.2 for Life Safety Performance Level in ASCE/SEI 31 or the Basic Safety

Objective in ASCE/SEI 41, unless otherwise specified.

8. “Tier 1 Evaluation” means an evaluation by an Engineer in accordance with Chapters 2.0 and 3.0 of ASCE/SEI 31. A Tier 1 Evaluation must include the appropriate Structural, Nonstructural and Geologic Site Hazards and Foundation Checklists.

9. “Tier 2 Evaluation” means an evaluation by an Engineer in accordance with Chapter 4.0 of ASCE/SEI 31.

10. “Tier 3 Evaluation” means an evaluation by an Engineer in accordance with Chapter 5.0 of ASCE/SEI 31.

3.03 SEISMIC SAFETY – HIGH SEISMICITY (MAY 2025)

In accordance with the Earthquake Hazards Reduction Act of 1977, the following apply:

A. The Government intends to award a Lease to an Offeror of a Building that is in compliance with the Seismic Standards. If an offer is received which is in compliance with the Seismic Standards and the other requirements of this RLP, then other offers which do not comply with the Seismic Standards must not be considered. If none of the offers is in compliance with the Standards, the LCO will make the award to the Offeror whose offer meets the other requirements of this RLP and provides the best value to the Government, taking into account price, seismic safety and any other evaluation factors specified in this RLP.

B. An offered Building will be considered to be in compliance with the Seismic Standards if it meets one of the following conditions:

1. The offer includes a representation that the Premises will be in a one-story Building of steel light frame or wood construction with less than 3,000 ABOA SF of space in the Building (Seismic Form D).

2. The offer includes a Seismic Certificate certifying that the Building is a Benchmark Building (Seismic Form A).

3. The offer includes a Seismic Certificate based on a Tier I Evaluation showing that the Building meets the Seismic Standards (Seismic

Form B). The submission must include the checklists and backup calculations from the Tier 1 Evaluation.

4. The offer includes a Seismic Certificate based on a Tier 2 or Tier 3 Evaluation showing that the Building complies with the Seismic

Standards (Seismic Form B). If the certificate is based on a Tier 2 or Tier 3 Evaluation, the data, working papers, calculations and reports from the evaluation must be made available to the Government.

5. The offer includes a commitment to retrofit the Building to satisfy all of the Basic Safety Objective requirements of ASCE/SEI 41 (Seismic

Form C, Part 1). If the Offeror proposes to retrofit the Building, the offer must include a Tier 1 report with all supporting documents, a narrative explaining the process and scope of retrofit and a schedule for the seismic retrofit. The Offeror shall provide a construction schedule, concept design for the seismic upgrade and supporting documents for the retrofit, including structural calculations, drawings, specifications, and geotechnical report to the Government for review and approval prior to award. The documentation must demonstrate the seismic retrofit will meet the seismic standards and be completed within the time frame required.

6. The offer includes a pre-award commitment to construct a new Building, using local building codes (Seismic Form C, Part 2).

C. The LCO may allow an Offeror to submit a Seismic Certificate after the deadline for final proposal revisions. However, the LCO is not obligated to delay award in order to enable an Offeror to submit a Seismic Certificate.

D. Definitions. For the purpose of this paragraph:

1. “ASCE/SEI 31” means the American Society of Civil Engineers standard, Seismic Evaluation of Existing Buildings. You can purchase

2. “ASCE/SEI 41” means American Society of Civil Engineers standard, Seismic Rehabilitation of Existing Buildings. You can purchase

3. “Benchmark Building” means a building that was designed and built, or retrofitted, in accordance with the seismic provisions of the applicable codes specified in Section 1.3.1 of RP 8.

4. Engineer” means a professional engineer who is licensed in Civil or Structural Engineering and qualified in the structural design of buildings. They must be licensed in the state where the property is located.

5. “RP 8” means “Standards of Seismic Safety for Existing Federally Owned and Leased Buildings ICSSC Recommended Practice 8 (RP

8),” issued by the Interagency Committee on Seismic Safety in Construction as ICSSC RP 8 and the National Institute of Standards and Technology as NIST GCR 11-917-12. RP 8 can be obtained from HTTPS://WWW.NIST.GOV/.

https://www.nist.gov/publications/standards-seismic-safety-existing-federally-owned-and-leased-buildings-icssc https://www.nist.gov/publications/standards-seismic-safety-existing-federally-owned-and-leased-buildings-icssc

RLP NO.57-28033-26-NR PAGE 5 GSA TEMPLATE R103 (10/24)

6. “Seismic Certificate” means a certificate executed and stamped by an Engineer on the appropriate Certificate of Seismic Compliance form included with this RLP together with any required attachments.

7. “Seismic Standards” means the requirements of RP 8 Section 2.2 for Life Safety Performance Level in ASCE/SEI 31 or the Basic Safety

Objective in ASCE/SEI 41, unless otherwise specified.

8. “Tier 1 Evaluation” means an evaluation by an Engineer in accordance with Chapters 2.0 and 3.0 of ASCE/SEI 31. A Tier 1 Evaluation must include the appropriate Structural, Nonstructural and Geologic Site Hazards and Foundation Checklists.

9. “Tier 2 Evaluation” means an evaluation by an Engineer in accordance with Chapter 4.0 of ASCE/SEI 31.

10. “Tier 3 Evaluation” means an evaluation by an Engineer in accordance with Chapter 5.0 of ASCE/SEI 31.

3.04 ENERGY INDEPENDENCE AND SECURITY ACT (SMALL) (MAY 2025)

A. The Energy Independence and Security Act (EISA) establishes requirements for Government leases relating to energy efficiency standards and potential cost-effective energy efficiency and conservation improvements.

B. If the offered Space is not in a Building that has earned the ENERGY STAR® Label within one year prior to the due date for final proposal revisions, Offerors are required to include in their lease proposal an agreement to renovate the Building for all energy efficiency and conservation improvements that it has determined would be cost effective over the Firm Term of the Lease, if any, prior to acceptance of the Space

C. The term "cost effective" means an improvement that will result in substantial operational cost savings to the landlord by reducing electricity or fossil fuel consumption, water, or other utility costs. The term "operational cost savings" means a reduction in operational costs to the landlord through the application of Building improvements that achieve cost savings over the Firm Term of the Lease sufficient to pay the incremental additional costs of making the Building improvements.

D. Instructions for obtaining an ENERGY STAR® Label are provided at

HTTPS://WWW.ENERGYSTAR.GOV/BUILDINGS/BUILDING_RECOGNITION (use “Portfolio Manager” to apply). The ENERGY STAR® BUILDING UPGRADE MANUAL and BUILDING UPGRADE VALUE CALCULATOR are tools which can be useful in considering energy efficiency and conservation improvements to Buildings.

E. If the offered Space is not in a Building that has earned the ENERGY STAR® Label within one year prior to the due date for final proposal revisions, the successful Offeror will be excused from performing any agreed-to energy efficiency and conservation renovations if it obtains the Energy Star Label prior to the Government’s acceptance of the Space

E. If no improvements are proposed, the Offeror must demonstrate to the Government using the ENERGY STAR® Online Tools why no energy efficiency and conservation improvements are cost effective. If such explanation is unreasonable, the offer may be rejected.

3.05 NATIONAL HISTORIC PRESERVATION ACT REQUIREMENTS – RLP (SMALL) (OCT 2023)

A. The Government is responsible for complying with section 106 of the National Historic Preservation Act of 1966, as amended, 54 U.S.C. §

306108 (Section 106). An Offeror must allow the Government access to the offered Property to conduct studies in furtherance of the Section 106 compliance.

B. If the Government determines that the leasing action could affect historic property, the Offeror of any Property that the Government determines could affect historic property will be required to retain, at its sole cost and expense, the services of a preservation architect who meets or exceeds the Secretary of the Interior’s Professional Qualifications Standards for Historic Architecture, as amended and annotated and previously published in the Code of Federal Regulations, 36 C.F.R. part 61, and the GSA’s Qualification Requirements for Preservation Architects. These standards are available at: HTTPS://WWW.GSA.GOV/REAL-ESTATE/HISTORIC-PRESERVATION/.

3.06 HUBZONE SMALL BUSINESS CONCERN PRICE PREFERENCE WAIVER (SMALL) (OCT 2023)

A HUBZone small business concern (SBC) Offeror may elect to waive the price evaluation preference provided in the “Basis of Award” paragraph. In such a case, no price evaluation preference shall apply to the evaluation of the HUBZone SBC.

https://www.energystar.gov/buildings/building_recognition/building_certification/how_apply https://www.energystar.gov/sites/default/files/buildings/tools/EPA_BUM_Full.pdf https://www.energystar.gov/buildings/tools-and-resources/building-upgrade-value-calculator https://www.gsa.gov/real-estate/historic-preservation/historic-preservation-policy-tools/preservation-tools-resources/proof-of-competency-other-documentation

RLP NO.57-28033-26-NR PAGE 6 GSA TEMPLATE R103 (10/24)

SECTION 4 - HOW TO OFFER

4.01 RECEIPT OF LEASE PROPOSALS (SMALL) (OCT 2023)

A. Offeror is authorized to transmit its lease proposal as an attachment to an email. Offeror's email shall include the name, address and telephone number of the Offeror, and identify the name and title of the individual signing on behalf of the Offeror. Offeror's signed Lease proposal must be saved in a generally accessible format (such as portable document format (pdf)), which displays a visible image of all original document signatures and must be transmitted as an attachment to the email. Only emails transmitted to, and received at, the GSA email address identified in the RLP will be accepted. Offeror submitting a Lease proposal by email shall retain in its possession, and make available upon GSA's request, its original signed proposal. Offeror choosing not to submit its proposal via email may still submit its lease proposal, by United States mail, or other express delivery service of Offeror's choosing.

B. In order to be considered for award, offers conforming to the requirements of the RLP shall be received no later than 4pm EST on the date specified below at the following designated office and address, or email address:

Date: August 29, 2026

Email Address: JASON.CLINDININ@USDA.GOV

C. Offers sent by United States mail or hand delivered (including delivery by commercial carrier) shall be deemed late if delivered to the address of the office designated for receipt of offers after the date and time established for receipt of offers.

D. Offers transmitted through email shall be deemed late if received at the designated email address after the date and time established for receipt of offers unless it was received at the initial point of entry to the Government infrastructure not later than 5:00 p.m. one Working Day prior to the date specified for receipt of proposals.

E. Offers may be also deemed timely if there is acceptable evidence to establish that it was received at the Government installation designated for receipt of proposals and was under the Government’s control prior to the time set for receipt of proposals; or if it was the only proposal received.

F. There will be no public opening of offers, and all offers will be confidential until the Lease has been awarded. However, the Government may release proposals outside the Government such as to support contractors to assist in the evaluation of offers. Such Government contractors shall be required to protect the data from unauthorized disclosure.

4.02 PROPOSAL CONTENTS FOR SMALL LEASES (OCT 2024)

The proposal shall consist of the following documents:

DOCUMENT NAME OR DESCRIPTION

U.S. Government Lease For Real Property (Short Form) (GSA Form 3626), completed and signed by Offeror Supplemental Lease Requirements, initialed by Offeror Agency Specific Requirements, Dated 07/13/2026, initialed by Offeror Security Requirements, initialed by Offeror GSA 3517A, General Clauses, initialed by Offeror Fire Protection and Life Safety information and documents (See applicable Fire Protection and Life Safety paragraphs) Auto CAD or scaled floor plans delineating the Premises proposed by the Offeror Seismic Form(s) Historic Property information and documentation, if applicable, per the Historic Preference paragraph Registration in the System for Award Management (SAM) prior to the Lease Award Date, including completion of all required representations and certifications. This registration service is free of charge.

EISA compliance information (See applicable Energy Independence and Security Act paragraphs) Evidence of ownership or control of Building or site, including a copy of the Property deed Authorization from the ownership entity to submit an offer on the ownership entity’s behalf, if the offeror is not the owner of the Property Proof of signing authority (see GSA 3516A, Solicitation Provisions) Small Business Subcontracting Plan, if applicable FAR 52.204-24, Representation Regarding Certain Telecommunications and Video Surveillance Services or Equipment Offeror’s Rate for Routine Cleaning and Disinfection Requirements

4.03 FIRE PROTECTION AND LIFE SAFETY SUBMITTALS (SMALL) (OCT 2020)

A. The Offeror must submit the Fire Protection and Life Safety (FPLS) Submittal Information in A.1 through A.5, unless the Building meets either exemption in sub-paragraph B or C below.

1. Completed GSA Form 12000, Prelease Fire Protection and Life Safety Evaluation for an Office Building (Part A or Part B, as applicable).

mailto:jason.clindinin@usda.gov

RLP NO.57-28033-26-NR PAGE 7 GSA TEMPLATE R103 (10/24)

2. A copy of the previous year’s fire alarm system maintenance record showing compliance with the requirements in NFPA 72 (if a system is installed in the Building).

3. A copy of the previous year’s automatic fire sprinkler system maintenance record showing compliance with the requirements in NFPA 25

(if a system is installed in the Building).

4. Computer generated plans set to 1/8" = 1'-0" (preferred). Plans submitted for consideration shall include floor plan(s) for which Space is being offered and floor plan(s) of the floor(s) of exit discharge (e.g., street level(s)). Each plan submitted shall include the locations of all exit stairs, elevators, and the Space(s) being offered to the Government. In addition, where Building exit stairs are interrupted or discontinued before the level of exit discharge, additional floor plans for the level(s) where exit stairs are interrupted or discontinued must also be provided.

5. A valid Building Certificate of Occupancy (C of O) issued by the local jurisdiction. If the Building C of O is not available or the local jurisdiction does not issue a Building C of O, provide a report prepared by a licensed fire protection engineer with their assessment of the Building regarding compliance with all applicable local Fire Protection and Life Safety-related codes and ordinances.

B. If the Space offered is 10,000 RSF or less in area and is located on the 1st floor of the Building, Offeror is not required to submit to GSA the Fire

Protection and Life Safety (FPLS) Submittal Information listed in A.1 through A.5 above.

C. If the Offeror provides a Building C of O obtained under any edition of the International Building Code (IBC), and the offered Space meets or will meet all the requirements of the Lease with regard to Means of Egress, Automatic Fire Sprinkler System, and Fire Alarm System prior to occupancy, then Offeror is not required to submit to GSA the FPLS Submittal Information in A.1 through A.5 above.

4.04 EISA SUBMITTALS (SMALL) (SEP 2015)

No later than the due date for final proposal revisions, the Offeror must submit to the LCO:

A. Evidence of an Energy Star® label obtained within the 12 months prior to the due date of final proposal revisions, or

B. If the offered existing building will not have an ENERGY STAR® label by the date of final proposal revisions, a written statement addressing which energy efficiency and conservation improvements (can be made to the building must be submitted. If no cost-effective improvements can be made, the Offeror must demonstrate to the Government using the ENERGY STAR® Online Tools why no energy efficiency and conservation improvements are cost effective. This explanation will be subject to review by the LCO. If the explanation is considered unreasonable, the offer may be considered technically unacceptable.

4.05 SWING SPACE - RLP (OCT 2022)

A. A renovation of the Space at the current location will be required to meet all the requirements of this RLP package, including the schedule requirements outlined under the Lease. The RLP package outlines a level of base building/shell requirements, tenant improvements and BSAC that will require all or portions of the Space to be vacant during renovations.

B. As part of the initial offer, the incumbent Lessor must submit a plan and schedule outlining specific swing space alternatives meeting the requirements stated herein and under Lease paragraph “Swing Space - Lease.” Any plan or schedule that does not efficiently or timely house the Government’s requirements or fails to adequately prevent disruption of Government operations may be rejected and the offer may be considered technically unacceptable. The swing space plan and schedule shall include, at a minimum, the following:

1. Detailed narrative demonstrating how renovations are proposed at the current location in accordance with all of the requirements of this

RLP package, including requirements set forth in this paragraph and Lease paragraph 7.06, Swing Space - Lease. Narrative shall clearly identify the number of Government staff member moves and outline how renovations will occur with minimum disruption and interference with ongoing Government operations;

2. Floor plan (computer generated plans set to 1/8” = 1’0” preferred) indicating block(s) of swing space including swing space finishes; and

3. Schedule of swing space and final Space to address interim moves demonstrating adherence to Lease schedule, inclusive of all phases, commissioning, and testing requirements.

C. Swing space must meet the following:

1. _Max 2800 RSF__________

2. _Restrooms_____________

3. _2 reserved parking spaces for government vehicles____________

D. Swing space offered at a location other than Hernando-Nesbit, MS must have the following area of consideration. An area bounded as follows:

North: __City Limits____________ South: __City Limits____________

RLP NO.57-28033-26-NR PAGE 8 GSA TEMPLATE R103 (10/24)

East: __City Limits____________ West: __City Limits____________

Buildings with Property boundary(ies) on the boundary streets are deemed to be within the swing space delineated Area of Consideration.

E. If the incumbent is not the owner of the offered property for swing space, an executed Letter of Intent for leasing such swing space to the Offeror, reflecting a minimum lease term coterminous with the completion of the renovation of Space, must be submitted no later than Final Proposal Revisions. If selected, control through ownership, lease, or binding option of such specific alternatives must be demonstrated within thirty (30) days after Lease Award.

F. The Government reserves the right to require a single group of employees (including contractor personnel) or successive groups of the

Government employees to be moved into and out of the swing space, based upon the Incumbent Lessor's proposal. The Government shall be responsible for the cost of moving each Government employee one time only, which shall be identified as the last and final move from the swing space to the final Space. The Incumbent Lessor shall be responsible for the cost of all moves, interim moves, and restacking in excess of one move per Government employee.

LEASE NO. 57-28033-26-NR

AGENCY SPECIFIC REQUIREMENTS (NOV 2023)

PAGE 1 LESSOR: ______ GOVERNMENT: ________

EXHIBIT A

USDA Agency Specific Requirements

Lease Number: 57-28033-26-NR (Hernando-Nesbit, MS)

The Agency Specific Requirements (ASRs) do not reduce the minimum requirements contained within the Lease. These ASRs provides specific agency requirements, which may be complementary, more specific, or more stringent than those of the Lease minimum requirements. To the extent the contents of these ASRs conflict with the contents of the Lease, the more stringent requirement shall apply.

A. ROOM SCHEDULE

The following spaces in these approximate sizes shall be provided by the Lessor.

State: MS City: Hernando-Nesbit

Delineated Area: City Limits Minimum Sq. Ft. (ABOA): 2030

Maximum Sq. Ft. (ABOA): 2132 Maximum Sq. Ft. (RSF) 2436

Space Type: Office Reserved Government Vehicle

Parking Spaces:

Reserved Visitor/Customer Parking Spaces:

Non-Reserved Employee Parking Spacing (located on-site or within 300 feet of premises):

Full Term: 15 Firm Term: 5

Termination Rights: 120 Days Additional Requirements: 300 square foot wareyard

Secured Storage on the property

PAGE 2 LESSOR: ______ GOVERNMENT: ________

B. ROOM DESCRIPTIONS

Lobby/Reception Area – The lobby area is designed for customers to enter, check in, and wait to be seen by USDA staff.

1. Electrical outlets according to local code.

2. Flooring, wall coverings, and window coverings according to Lease.

3. See Physical Security requirements below for additional information.

Design Examples:

Private Offices- Private offices shall be designed to accommodate (1) one individual seated at a desk, with space for (2) two additional guests. These spaces are to be utilized by individuals who require acoustic and visual privacy for meetings and phone calls or tele/video conferencing. Interior glass window with blinds to provide visibility to the open office and allow daylight to penetrate through.

1. Sound Transmission Class rating as specified in Lease.

2. Greater of three (3) double electrical outlets or local code.

3. Two (2) telecommunication outlet.

4. Flooring, wall coverings, and window coverings according to Lease.

Design Example:

PAGE 3 LESSOR: ______ GOVERNMENT: ________

Consult Room – Consult rooms shall be designed to seat up to 4 individuals for hosting small meetings, phone calls, tele/video conferencing, or for individual working. Locate adjacent to workstation clusters and in close proximity to enclosed offices. When possible, provide access to natural daylight.

Interior glass window with blinds to provide visibility to the open office and allow daylight to penetrate through. Provide film at seated height for partial privacy.

2. Greater of five (5) double electrical outlets or local code.

3. Two (2) telecommunication outlet.

4. Flooring, wall coverings, and window coverings according to Lease.

Conference Room - Meeting rooms for 10-12 people for large meetings, tele/video-conferencing, as well as presentations. Locate centrally within the office and adjacent to the reception/service desk in order to provide immediate access for invited guests. Ideally, locate close to the break area for convenience for invited guests. Consider locating doors off of the open office area for acoustic privacy. Provide access to daylight when possible.

2. Greater of five (5) double electrical outlets or local code.

3. One (1) or Two (2) telecommunication floor boxes.

PAGE 4 LESSOR: ______ GOVERNMENT: ________

4. Lessor to provide data jack and audio-visual (A/V) connection for installation of a wall mounted television to use for presentations. Lessor is responsible for maintenance of connections/wiring and data jack, but television is the property of USDA and is to be installed and maintained by USDA.

5. Flooring, wall coverings, and window coverings according to Lease.

Break Room - An enclosed or semi-enclosed space to serve as a destination for refreshment. The space is provisioned to support food preparation and storage, coffee machines and recycle bins.

Depending on size of office this may be an area for socialization, so seating area should be provided.

Locate adjacent to conference room. Some enclosure is necessary to reduce transmission of noise and smells into the workplace.

2. Greater of four (4) double electrical outlets or local code, in addition to the outlets required for refrigerator/freezer and microwave. Outlets provided at counter per local code.

3. Flooring, wall coverings, and window coverings according to Lease.

4. Lessor to provide and maintain, as part of operations and maintenance of the Premises, a breakroom refrigerator with freezer (at least 18 cu ft in size) and countertop microwave oven.

The Lessor shall retain ownership of these items, and associated costs shall be included in Operating Expenses on the Form 1217.

5. Minimum of ten (10) feet of counter with base and overhead cabinets and double compartment sink.

PAGE 5 LESSOR: ______ GOVERNMENT: ________

Secure Storage – This room is for equipment or other content that needs to be securely stored, but easily accessible within the office. Size and type of storage units will vary depending on content requirements.

1. Room shall not be accessible through the ceiling to prevent “up and over” access. Utilize slab-to-slab walls or installation of steel mesh to prevent intrusion.

2. Solid core door with door hinges installed inside the room. No windows or other openings.

3. Fire extinguisher required.

4. Sound Transmission Class rating as specified in Lease.

5. Greater of three (3) double electrical outlets or local code.

6. Flooring and wall coverings according to Lease.

Open Office - A standard space for an individual to accomplish focused solo work and short-term collaborative work who spend most of their time at their desk. Individual workstations are provided in combination with easily accessible meeting spaces for group work and focus booths for concentration or private conversation. Place near floor perimeter to maximize access to natural light.

Generally, this is open space where systems (cubicle) furniture will be installed by USDA. Lessor must ensure electrical and data connections are available to hard wire the installed furniture, and Lessor is responsible for providing an electrician to undertake or assist with the furniture installation.

Data and electrical can be provided via ceiling drops or wall connections.

PAGE 6 LESSOR: ______ GOVERNMENT: ________

Mud Room - The Mud Room includes an area of approximately 120sf for cleaning and washing field equipment. The room shall be located away from open offices areas. Recommend locating adjacent to a point of entry, to limit path of travel through office. Locate near lavatories or existing plumbing.

2. Electrical outlets per local code.

3. Flooring, wall coverings, and window coverings according to Lease.

C. REQUIRED FEATURES NOT INCLUDED IN SHELL COSTS: For all of these items, purchase and installation should be included in the Lessor’s Tenant Improvement costs and ongoing maintenance should be an Operating Cost included on GSA Form 1217.

1. Lessor to install and maintain all Telecommunication Requirements (development of ADP

Room, CAT wiring, etc.) as outline in Lease Exhibit G.

2. If the US Postal Service will not deliver and pick up mail from each USDA agency inside the Premises, then the Lessor is required to provide and maintain separate mailboxes for each USDA agency in the Premises. The mailboxes must be lockable and acceptable to both USDA and USPS. The incoming mailboxes must be of sufficient size to accept a single package of 9” wide x 11 ½” deep x 12” high, or a separate common oversized mailbox of that minimum size must be provided. A separate outgoing mailbox capable of holding outgoing parcel of a minimum of 9” wide x 11 ½” deep x 12” high must also be provided by Lessor. Location and design must be approved by LCO or designated representative.

3. Lessor to install and maintain a locking depository drop box. Drop box should be secure and provide the ability for receipt of documents from exterior of building without entering interior areas of the building. Location and design must be approved by LCO or designated representative.

4. Lessor to provide and maintain signage as outlined in USDA Facility Signage Guide as furnished by the Government.

a. The monument sign must be such that the sign is visible from both directions of traffic.

b. Sign locations and design must be approved by LCO or designated representative.

PAGE 7 LESSOR: ______ GOVERNMENT: ________

c. Should the location of the leased Premises not be evident to customers parking in the parking lot, the Lessor shall install and maintain directional or wayfinding signage from the parking area to the Premises.

5. Lessor to Install and maintain fire extinguishers, smoke detectors, and carbon monoxide detectors.

6. Lessor to provide and maintain approximately 200 square feet (10-foot x 20-foot structure) of exterior storage at the Premises. Structure must include a minimum 10-foot by 10-foot overhead door to accommodate UTV/ATVs with trailers.

7. Secured Parking Requirements

• Secured Parking needed to accommodate 2 GOVs and 6 parking spaces for support equipment.

• Secured Parking to be enclosed with fencing 6’ in height.

D. REQUIRED FEATURES TO BE INCLUDED IN SHELL COSTS: Lessor shall include the costs associated with these features in Shell Rent.

1. The leased Premises must comply with accessibility requirements set forth in Section 3.15 of

Lease at the time of lease commencement. Offeror must agree to correct the following accessibility related deficiencies found in previously completed ABAAS review:

2. Lessor to provide an exterior area large enough for an 8 foot by 10-foot storage shed at the Premises. USDA will provide, maintain, and retain ownership of the shed. Lessor shall note that USDA may store gasoline for ATV use, and the location of the shed must meet all local building codes and required setbacks. Shed location to be coordinated with and approved by LCO or designated representative.

E. PHYSICAL SECURITY REQUIREMENTS

In addition to the specifications set forth in Section 7.01 of the Lease, the Lessor is required to install the necessary improvements to meet the below requirements. Costs associated with the purchase and installation of improvements are considered Tenant Improvements (TI) and should be reflected in the Tenant Improvements Costs Summary (TICS) table. Costs to operate and maintain these improvements are considered operating expenses and should be reflected in the Lessor’s Annual Cost Statement (GSA Form 1217).

1. Hardened Customer Service Counter: A Hardened Customer Service Counter or Service

Window shall be installed to separate the public lobby area from employee workspace. It shall be designed in a way that customers cannot access USDA space (on the other side of the counter) unless permitted entry through a locked door. This counter must be a hardened barrier that requires employees to enter through a locked door to enter from the public side of the counter into USDA employee space. The door must have a lock and remain secured at all times. The counter shall be 42” to 48’’ high and may have a glass or barrier partition above the counter to enclose it. In limited circumstances, offices can also elect to keep the main customer entrance door secured at all times and have a buzzer or intercom installed at the secure door to communicate with visitors. In this configuration, a hardened customer service counter is not required since the office is secure.

2. Entrance Door Chime: An entrance door chime shall be installed on the main/customer entrance to notify employees when a visitor enters the facility to increase employee situational awareness.

3. Duress/Panic Buttons: All USDA Main Entrance/Reception areas shall have a duress/panic alarm installed that is monitored. Additional duress/panic buttons shall be placed in all areas that employees routinely service customers.

PAGE 8 LESSOR: ______ GOVERNMENT: ________

4. Intrusion Detection System (IDS) Coverage and Monitoring: All offices shall have an Intrusion Detection System (IDS) alarm installed. This system shall consist of door contacts for all perimeter entry and exit doors to USDA space; magnetic contacts for operable ground floor windows, acoustic glass break detectors for glass doors, doors with glass windows, or ground level windows; passive infrared motion sensors (if needed); an alarm keypad (one needed per office suite); and an auto-dialer for alarms to annunciate to a monitoring service for after-hours monitoring.

5. Main/Customer Entrance Emergency Lockdown: A locking device is required on the main/customer entrance that will easily allow for locking/unlocking the door in emergencies.

To support an emergency lockdown, a thumb turn deadbolt, or some other device shall be installed on the main entrance door so the door can be locked immediately in an emergency.

6. Space Compartmentalization - False Ceiling: Any suspended (false) ceilings that lead into

USDA-FPAC space from a wall in a common hallway or other tenants’ space must be secured in a manner that no individual can enter USDA space undetected or unmonitored by exploiting the gap above the false ceiling wall. The preferred method of securing the space is to install “slab to slab” walls that separate the USDA space from the rest of the facility.

However, installing steel fencing mesh affixed to the true ceiling and the existing walls or drywalling the open area are also acceptable.

7. Perimeter Doors and Door Locks Leading to USDA-FPAC Space: Perimeter doors to

USDA space must be either glass storefront doors, metal high-security doors, or solid-core wood doors. Hollow core doors are not permissible. Door hinges must be located on the inside of the door (non-public side), or exposed door hinge pins must be permanently secured to prevent removal. Approved methods include tack welding or locking screws to hold pin in place. Perimeter door locks must be either electronic access control, high security cipher, or high-security mechanical locks, preferably with a dead-bolt. Cipher locks are highly encouraged to avoid the need to issue keys. All exposed door locking mechanisms, except for deadbolts, must be covered by a door strike plate cover to prevent the mechanism from tampering. All doors without a window, shall have a peephole installed in the door. All door locks shall be rekeyed prior to USDA leasing the space and all keys must be accounted for.

8. Emergency Exit Doors: Emergency exits doors shall include an automatic door closer and exit hardware that is compliant with applicable life safety codes and standards. All emergency exits doors shall have signage posted on the interior side of the door stating, “Emergency Exit Only”. Emergency Exit doors shall have no visible hardware on the exterior.

9. Window Air-Conditioning (A/C) Unit Protection: If window A/C units are installed, they must be secured with a lockable cage or window bars in a way that prevents the window unit from being pushed in or removed.

10. Protection of Exterior Gas Mains or Propane Tanks Adjacent to Premises: If there is exposed gas mains/meters or propane tanks near a facility façade or in a parking lot, they must have bollards (typically yellow safety bollards) or some other barrier (i.e., boulder) placed around it to protect it from a vehicle strike.

11. Security of Exterior Electrical Panels and Switches: If applicable, exterior electrical panels on the outside of the building or in common/public space shall be secured via a locking device, unless not permitted by local code. The preferred location for electrical panels is inside the USDA space or in a secured area on the interior of the building.

12. Public Restroom Access: Lessor must secure public restrooms (restrooms located in the building common area) in a manner that only facility tenants can access them and not the general public. This can be done by securing the restrooms with either a hard key or an access code.

13. Fire and Carbon Monoxide Detection: Ensure an appropriate amount of smoke and carbon monoxide detection devices as needed and in accordance with local code.

PAGE 9 LESSOR: ______ GOVERNMENT: ________

14. Perimeter Lighting: Ensure that the building exterior entrances/exits are illuminated to a minimum of 5 foot-candles; Sidewalks and walkways illuminated to a minimum of 3 foot-candles; and Parking lot surfaces illuminated to 1 foot-candle throughout the parking areas.

Lighting must meet this standard at all times in periods of darkness. Only having motion activated lighting is not sufficient.

15. Interior Office Doors: Interior doors to offices, conference rooms, restrooms, and break rooms shall not be hollow core wood or any other interior residential use door. Doors shall be solid core wood or equivalent. All doors to private offices shall have door locking mechanism (residential use internal locks are not permitted).

16. Landscaping: Landscaping shall be maintained and trimmed as needed to prevent it from creating areas of concealment around the facility and parking areas. Landscaping shall not be overgrown where it impacts lighting illumination, camera views (if applicable), and a clear line of sight.

SOLICITATION PROVISIONS

(For Simplified Acquisition of Leasehold Interests in Real Property)

1. 552.270-1 INSTRUCTIONS TO OFFERORS – ACQUISITION OF LEASEHOLD INTERESTS IN

REAL PROPERTY (JUN 2011) – ALTERNATE II (MAR 1998)

(a) Definitions. As used in this provision—

“Discussions” are negotiations that occur after establishment of the competitive range that may, at the Contracting Officer’s discretion, result in the offeror being…

This is the start of the file's text. The full file is on GovTribe.