Combined Cover Sheet and SOW FREDERICK HATCH.pdf

PDF 579 KB Posted

Attached to
CGC FREDERICK HATCH U/W HULL CLEANING AND OPTIONAL ZINC REPAIR
Solicitation number
52000QR270000684
Issued by
Not on record

About this file

This is a Statement of Work (SOW) for underwater cleaning, inspection, and maintenance services for the USCGC Frederick Hatch, a U.S. Coast Guard cutter located at Naval Base Guam.

The contractor must perform definite work including: submitting pre- and post-cleaning underwater video documentation highlighting key areas such as bow thrusters, propellers, rudders, and transducers; cleaning all underwater body surfaces free of marine growth, debris, and contaminants in accordance with 29 CFR 1910 Subpart T (Commercial Diving Operations); removing and replacing sea chest grating if necessary; cleaning transducer surfaces with handheld brushes only (no power attachments); ensuring no damage to existing coatings; polishing propellers; and submitting a final written service report. Optional/conditional work includes renewing government-furnished bolt-on zinc anodes pending inspection results and Change Request (CR) approval. Provided Government-furnished materials include stern tube anodes (28 each), self-locking nuts, sea chest grate anodes (4 each), propeller zinc plates (2 each), bow thruster anodes (13 total), and associated fasteners and screws. The performance period is December 1–11, 2026, with specific performance dates to be coordinated with the Government Point of Contact, MKC Paul Kurkowski (954-999-7208, paul.j.kurkowski@uscg.mil). All contractor personnel must possess a valid REAL ID-compliant state-issued driver's license or acceptable DHS-approved identification for base access at Naval Base Guam, Santa Rita, Guam 96915. The work accomplishes Coast Guard Maintenance Planning Code B10015.D and potentially B10018.D per publications dated October 31, 2024, and April 30, 2025, respectively.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work (SOW) Cover Sheet

CGC FREDERICK HATCH, Clean/Inspect/Video Underwater (U/W) Body Surfaces (renew failed zinc anodes)

Work Items:

Clean/Inspect/Video Underwater (U/W) Body Surfaces (renew failed zinc anodes)

1. REFERENCES:

COAST GUARD PUBLICATIONS

154-WPC MPC B10015.D rev 10/31/24 154-WPC MPC B10018.D rev 04/30/25

OTHER REFERENCES

Code of Federal Regulations (CFR) Title 29, Part 1910, Subpart T, 7/16/2026, Commercial Diving Operations

2. REQUIREMENTS

See each work item for requirements. This SOW accomplishes MPC B10015.D and potentially B10018.D.

3. PERIOD OF PERFORMANCE (POP)

The POP for the requirement shall be between 12/01/26 - 12/11/26. Specific performance dates shall be coordinated with the Government POC to accommodate operational requirements. The contractor shall be available to perform the service during the specified POP window.

4. PLACE OF PERFORMANCE

The primary place of performance shall be at CGC FREDERICK HATCH located at below address:

CGC FREDERICK HATCH

NAVAL BASE GUAM

SANTA RITA Guam 96915

USA

POC: MKC Paul Kurkowski Cell: (954) 999-7208 Email: Paul.J.Kurkowski@uscg.mil

5. SECURITY REQUIREMENTS

All contractor personnel requiring access to the place of performance in order to perform work under this contract must possess a valid-state issued REAL ID-compliant driver’s license or identification card, or an acceptable alternative form of identification as defined by the Department of Homeland Security (DHS) [https://www.dhs.gov/real-id]. It is the contractor’s responsibility to ensure that all personnel are properly credentialed to gain base access. Failure to comply with access requirements may result in delays to performance and will not constitute an excusable delay.

87WPB & 154WPC 11101 PBPL 28AUG26 Page 1 of 2

Statement of Work (SOW) Clean/Inspect/Video Underwater (U/W) Body Surfaces

(renew failed zinc anodes)

1. SCOPE

1.1 Intent: While the vessel is moored pier side, clean the vessel’s U/W body and (pending inspection) renew bolt-on zinc anodes (if needed).

CUTTER USCGC FREDERICH HATCH (Hull #1143)

ADDRESS NAVAL BASE GUAM

SANTA RITA Guam 96915

USA

Period of Performance (POP) 12/01/26 thru 12/11/26

CUTTER POC MKC Paul Kurkowski, (954) 999-7208, paul.j.kurkowski@uscg.mil

1.2 Government-furnished property.

MTI ITEM DESCRIPTION NSN/PN QTY

N Anode, stern tube P/N: Z0020202H3

NIIN: 016445483

28 ea.

N Nut, Self-Locking P/N: 90715A145

NIIN: 015085774

2 Bx *24 in a bx

N Anode, Sea Chest Grate P/N: GA-4

NIIN: 016476179

4 ea.

N Screw, Prop zinc plate P/N: 950756

NIIN: 016340210

8 ea.

N Screw, Sea Chest Grate Anode, P/N: 93190A634

NIIN: 016197182

4 ea.

N Screw Cap, Stern Tube Covers

P/N: 90585A626

NIIN: 016161107

42 ea.

N Zinc plate, propeller P/N: 950733

NIIN: 016278941

2 ea.

N Anode, Bow Thruster, Gear Case, Bolt On

P/N: 1081226

NIIN: 123561870

1 ea.

N Anode, Bow Thruster, Tunnel, Bolt On

P/N: CM2000Z

NIIN: 200126334

12 ea.

2. REFERENCES

*Access to some drawings may be Export-Controlled and require any recipient to be registered in the Joint Certification

Program (JCP) through DLA to receive the drawing. *

COAST GUARD DRAWINGS

None

87WPB & 154WPC 11101 PBPL 28AUG26 Page 2 of 2

COAST GUARD PUBLICATIONS

OTHER REFERENCES

Code of Federal Regulations (CFR) Title 29, Part 1910, Subpart T, 7/16/2026, Commercial Diving Operations

3. REQUIREMENTS

This SOW accomplishes MPC B10015.D and potentially B10018.D.

3.1 DEFINITE WORK. The Contractor must:

3.1.1 SUBMIT A PRE AND POST CLEANING VIDEO. Submit before cleaning and after cleaning video highlights of underwater body surfaces (e.g. bow thruster, propellers, rudders, transducers, heavily fouled hull areas, etc.).

3.1.2 CLEAN AND INSPECT UNDERWATER BODY SURFACES. Clean the U/W body surfaces free of all marine growth, debris, and all other surface contaminants in accordance with 29 CFR 1910.

Remove and replace sea chest grating if necessary to access/clean sea chest suction. Ensure all transducer surfaces are cleaned with only handheld brushes, without the use of power attachments. Ensure that the existing U/W body coating system or non-coated surfaces do not incur any damage during cleaning process. Polish propellers.

3.1.3 SUBMIT FINAL REPORT. A written service report must be provided detailing the services accomplished.

3.2 OPTIONAL/CONDITIONAL WORK.

3.2.1 RENEW ANODES. Pending inspection results and release of a CR, renew Government-furnished components listed below paragraph 1.2. Anodes may require slight modification to ensure proper fit (e.g., trimming metal tabs, drilling tab bolt holes, etc.).

154-WPC MPC B10015.D rev 10/31/24 154-WPC MPC B10018.D rev 04/30/25

2. Cover Sheet SAP Packages HATCH
3b. SAP SOW-Clean UW Body Renew Anodes hatch
1. SCOPE
2. REFERENCES
COAST GUARD DRAWINGS
COAST GUARD PUBLICATIONS

3. REQUIREMENTS

File details come from the government source that posted it. Updated .