vpx-300p-conv-10hp.pdf

PDF 350 KB Posted

Attached to
COTS--VPX Components Federal contract opportunity
Solicitation number
515_Elma_VPX
Issued by
Department of the Navy Naval Sea Systems Command

About this file

This document appears to be a pre-solicitation notice for a federal contract opportunity to supply COTS VPX components to the Naval Surface Warfare Center, Philadelphia Division.

The key details are:

The required components and quantities are: ComEth4582a Switch (375 units), PAE03727 Switch Expander (686 units), and VPX-300-PCONV10HP Power Supply (686 units), to be delivered between 7/23/2025 and 5/8/2031. Specifications for each component are provided. This is not a request for proposals, but the government is seeking information from interested parties on their capability to supply these components. Responses should be submitted by email to the contracting officer by 4:00 PM on 6/25/2024. The contract will be awarded by the Department of the Navy Naval Sea Systems Command.

View the file

Other files for this federal contract opportunity

Other files attached to COTS--VPX Components, newest first.
File Type Posted
Cometh4582a_v14.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

300 Watts Convection Cooled

OpenVPX VITA 62 Compliant

• 300 Watts in a 3U x 10HP x 160mm Modular Design

• Wide Range AC Input with Active Power Factor Correction

• Meets MIL-STD-1399, Section 300A (Type 1) for the Voltage Range Specified

• VITA 62 Outputs; +12V/10A, +3.3V/20A, +5V/20A, Aux_+12V/1A, Aux_-12V/.75A, Aux_+3.3V/2A

• No Minimum Load Required

• Custom Input/Output Configurations Available

• N+1 Redundant with Internal Oring FET's/Diodes

• VITA 62 Convection Cooled Style

• Side Covers Support Two-Level Military Maintenance Requirements

• Ruggedized Mechanical Design

• One Year Warranty

• Greater than 150,000 Hrs MTBF

• Proudly Made in U.S.A.

KEY FEATURES:

VPX-300P-CONV-10HP

3601 Veterans Highway Ronkonkoma, New York 11779 Tel: 631-981-7231 Fax: 631-981-7266 visit us at:

switchpwr.com

VPX-300P-CONV-10HP

REV: D

Nominal Input Voltage 115/230 Vac, 3.0/1.5A max.

Frequency 47-63 Hz , 400Hz.

Operational Input 90-264 VAC. Power factor is 0.99 typical at full load.

Voltage Range Meets EN 61000-3-2.

Inrush Current Less than 4 msec. 30 amperes @ 115 Vac or 60 amperes @ 264 Vac.

Brownout Protection: Holds Regulation to 85 Vac.

Fusing 6.3 Ampere, 250 Vac, Internal ceramic body fuse.

Hold up time 20msec minimum after loss of AC input at full load and any input.

Efficiency 81% typical Turn on time 1 sec max. from power up.

Line and Load ±2% over AC input range and Regulation 0 to 100% load change.

Minimum Load No minimum load required.

Ripple & Noise Through 20MHz 1% max. or 50mv whichever is greater for all outputs, peak to peak, with coaxial probe and 0.1uF/10uF capacitors at the connector.

Transient Response Output maximum excursion of ± 5% for 25% load step. Recovery less than 500 µsec.

Overshoot Less than 5%.

Output Isolation Isolated from chassis ground, 100Vdc.

Input/Output Isolation 1500Vdc from input to both chassis/outputs.

Reverse Voltage Protected against reverse voltage to supply current rating.

Overvoltage Shutdown at 130% of nominal Vout.

Protection Recycle input power to reset.

Overtemperature Unit shuts down if overheated. Automatic recovery.

Protection Leakage Current 1.5mA max at 240Vac.

Current Limiting All outputs protected with current limit.

Automatic recovery when overload or short is removed.

Redundant Full power N+1 redundant with integral Oring FET's/Diodes.

Paralleling Two or more supplies can be operated in parallel and will share +12V/+3.3V/+5V current to within ±10% of each other.

Remote Sense Compensates for up to 0.5V total distribution voltage drop on the +12V, +3.3V and +5V outputs.

Enable* VITA 62 compliant. Reference SPI's VPX Signal data sheet for more details.

INHIBIT* VITA 62 compliant. Reference SPI's VPX Signal data sheet for more details.

SYSRESET* VITA 62 compliant. Reference SPI's VPX Signal data sheet for more details.

FAIL* VITA 62 compliant. Reference SPI's VPX Signal data sheet for more details.

NED VITA 62 compliant. Reference SPI's VPX Signal data sheet for more details.

VBAT VITA 62 compliant. Reference SPI's VPX Signal data sheet for more details.

Geographical VITA 62 compliant. Reference SPI's VPX Signal data sheet Addressing for more details.

Protocol (I²C) VITA 62 compliant. Reference SPI's VPX Signal data sheet for more details.

Indicators Green LED indicating Input OK, Red LED indicating a power supply fault.

Cooling 400 Lfpm of forced air required through heat exchanger.

Operating Temperature -40°C to +65°C operating temperature with specified airflow.

Stability All outputs 0.1% for 8 hrs. after 30 minute warm-up.

Humidity Up to 95% non-condensing.

Storage Temperature -55°C to 105°C.

Connectors VITA 62 compliant Size 3U x 10HP x 160mm Weight: 3.00 lbs.

EMC Designed to meet Mil-Std-461F with SPI's external filter, Top Assembly 25880, or equivalent.

Common Options Conformal coating with Paylene & special output configurations. Consult factory for more details on a tailored solution which meets your requirements.