51501221 DATA.pdf
PDF 275 KB Posted
- Attached to
- STUD FULL BODY
- Solicitation number
- SPMYM225Q2505
About this file
This Material Ordering Data document (MIL-DTL-1222) specifies detailed requirements for high-reliability fasteners, specifically a stud with the part number M1222ST1C18C396NANN. The stud is 1-1/8" in diameter, 6" long, with a 7UNC-3A thread series, Grade 400, and can be either as-formed or stress-relieved. The fasteners are intended for general, high-temperature, high-strength, and corrosive environment applications where a high degree of reliability is required.
The document requires chemical analysis and mechanical property test results for the fasteners. Additional requirements include marking unit, intermediate, and shipping containers in accordance with MIL-STD-129, with specific reference to DLA Procurement Note C20. The fasteners are designed to withstand diverse conditions including elevated temperatures, sea water immersion, salt air/marine environments, high preloads, and high shock loadings. The document was prepared by Carl Pagel with code 260V.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 25Q2505 STUD FULL BODY.pdf | ||
| 51501223 DATA.pdf | ||
| 51501223 CDRL.pdf | ||
| 51501221 CDRL.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MATERIAL ORDERING DATA
MIL-DTL-1222
IDN: 4523A 5150-1221
ICN: 38LNG24411 KO: S02 KOI: 027
Any specification that is referenced in this Material Order Data sheet is required to be to the latest revision at time of award.
Paragraph 6.2 Ordering Data
A. MIL-DTL-1222J, GENERAL SPECIFICATION FOR STUDS, BOLTS, SCREWS AND
NUTS FOR APPLICATIONS WHERE A HIGHER DEGREE OF RELIABILITY IS
REQUIRED; dated 08 DEC 2000.
B. Part Number (see 3.14): M1222ST1C18C396NANN
1. Configuration, Type, Style, Grade & Condition (see 1.2): STUD, TY-1, STY-C, GR-400, AS FORMED or STRESS RELIEVED.
a. Configuration for socket head cap screws style: N/A (ASME B18.3 para 1.2)
2. Size, Length (for studs, bolts and screws) (see 3.9.2.2): 1-1/8" DIA. X 6" LG.
3. Thread series, and class of fit (see 3.9.1): 7UNC -3A
4. When needed for type IV studs, end configuration shall be (see 3.9.2.2): N/A
5. When a nonstandard fastener is needed, it may be specified on a drawing (see
1.2): N/A C. The current issue of DoDISS and individual documents is to be cited in the solicitation.
D. When heat treatments do not need to be controlled in accordance with AMS 2750 and MIL-
STD-1684: N/A
E. Type of coating and the minimum coating thickness for all internally-threaded fasteners, all externally-threaded fasteners with class 3A or 5 threads, and those externally-threaded fasteners with class 2A threads that need a thicker coating, when required: N/A
F. When aluminum alloy fasteners are to be coated with an immersion zinc flake/chromate dispersion coating, the coating procedure and thickness requirements shall be provided:
N/A
G. When titanium alloy fasteners are to be coated with an inorganic coat: N/A H. When cut or ground threads are not permitted: Permitted I. The tread series, when a nonstandard thread series is needed: N/A J. Bearing surface of the bolt or nut, when a specific bearing surface is needed: CHAMFERED
STUD ENDS
K. Is self locking element required? No If yes, specification type/class: Select one:
6.1 Intended use. Fasteners meeting this specification are intended for general, high temperature, high strength and corrosive environment applications where a high degree of reliability is required. It is designed to be used to acquire commercial off-the-shelf fasteners with added inspections to verify the high degree of reliability required. Fastener types and grades have been selected to meet diverse applications which include: elevated temperatures, immersion in sea water, salt air/marine environments, high preloads and high shock loadings.
MATERIAL ORDERING DATA
MIL-DTL-1222
L. Identification markings, when a nonstandard identification marking is needed: N/A (Per
NSTM S9086-CJ-STM-010 Chapter 75 Rev 5, para 075-3.2.2.1.1, Level I alloy steel socket head capscrews shall be marked “A574;” marking “STM” is also acceptable.)
M. When required the following are to be reported:
1. Examination test results: NO
a. Specify which test type desired (e.g., PT, MT): N/A
2. Chemical analysis: YES
3. Mechanical property test results: YES
4. Decarburization test: NO
5. Magnetic permeability test: NO
N-BB: YES
Note to Engineer: If you select “yes”, specify additional requirements in the Additional Data Requirements section.
Note to Vendor: If anything from sections N-BB applies, it is specified in the Additional Data Requirements section.
Additional Data Requirements:
All unit, intermediate and shipping containers must be marked in accordance with MIL-STD-129.
Refer to DLA Procurement Note C20 for further instructions.
Prepared By: Carl Pagel Code: 260V