This is a technical specification document detailing requirements for three 1-inch reinforced rubber hose assemblies. The specification calls for 85-foot long hose assemblies with female 1-inch CRES camlock crimped fittings (Dixon 100-C-SS) on both ends, with a working pressure of 150 PSIG, 29 IN HG vacuum capability, and 1-inch minimum bend radius. The crimp sleeve/ferrule installation must conform to manufacturer recommendations and NAHAD 500 guidelines.
The document specifies quality control requirements including a hydrostatic proof test at 250 PSIG minimum for 5 minutes with no leakage, deformation, cracking or damage permitted. After testing, hoses must be free of damage, nicks, cuts, soft spots, and bulges, and must be cleaned, dried and plugged for shipment. Data requirements include certification of the hydrostatic test per Exhibit A sequence A001.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TECHNICAL SPECIFICATION
REQ DOC NO. - 5016V315 ATTACHMENT_____1____
CONTINUATION SHEET CONTRACT NO. - _______________ PAGE _1__ OF _2__
NAME OF OFFER OR/CONTRACTOR
ONE (1) IN X 85 FT LONG; HOSE ASSEMBLY 3 EA
C. DESCRIPTION/SPECIFICATIONS
C.1 ONE (1) INCH REINFORCED RUBBER HOSE ASSEMBLY WITH FEMALE
ONE (1) INCH CRES CAMLOCK CRIMPED FITTINGS (DIXON 100-C-SS)
ON BOTH ENDS.
C.1.1 EIGHTY-FIVE (85) FEET OVERALL LENGTH
C.1.2 WORKING PRESSURE: 150 PSIG
C.1.3 29 IN HG VACUUM
C.1.4 ONE (1) INCH MINIMUM BEND RADIUS
C.1.5 CRIMP SLEEVE/FERRULE INSTALLATION TO CONFORM WITH
MANUFACTURERS RECOMMENDATIONS AND NAHAD 500
GUIDELINES.
C.2 PERFORM A HYDROSTATIC PROOF TEST TO 250 PSIG MINIMUM FOR 5
MINUTES.
C.2.1 ACCEPTANCE CRITERIA: NO LEAKAGE, DEFORMATION,
CRACKING OR DAMAGE.
C.3 AFTER HYDROSTATIC PROOF TEST, HOSES TO BE FREE OF
DAMAGE/NICKS/CUTS/SOFT SPOTS/BULGES ETC AND
CLEANED/DRIED AND PLUGGED FOR SHIPMENT.
ITEM # SUPPLIES/SERVICES QTY U/I
TECHNICAL SPECIFICATION
C.2 DATA REQUIREMENTS PER EXHIBIT A (DD-1423) & ATTCHMENT #1.
C.2.1 CERTIFICATION OF HYDROSTATIC TEST; EXHIBIT A SEQUENCE
A001.