Attachment_1_Statement_of_Work.pdf

PDF 437 KB Posted

Attached to
Autoclave Equipment Repair Federal contract opportunity
Solicitation number
47QSWA-Y6-18-MRO4
Issued by
GSA Federal Acquisition Service

About this file

Attachment 1 - Statement of Work (SOW)

View the file

Other files for this federal contract opportunity

Other files attached to Autoclave Equipment Repair, newest first.
File Type Posted
Attachment_5_Nitrogen_Heater_Repair_Pictures.pdf PDF
Amendment_2_SF_30_dated_5.25.18.pdf PDF
Attachment_4_B-831214_A.PDF PDF
Amendment__1_SF_30_dated_5.17.18.pdf PDF
Attachment_3_SF1449_Autoclave.pdf PDF
RFQ__Autoclave.pdf PDF
Attachment_2_SCA_WD_San_Diego_CA.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1, SCOPE:

STATEMENT OF WORK

Repair of the 7'

Autoclave System

N65888018326

1.1. This Statement of Work {SOW) identifies necessary supplies and services to establish an on site service agreement of a Government�owned asset located at Fleet Readiness Center Southwest (FR.CSW), NAS North Island, San Diego, CA. 92135-7058.

1.2. The requested service is to repair the 7' Autocla\le System in Building 250 ND\ to full working condition which consists of the Liquid Nitrogen Steam System, the Programmable Logic Controller (PLC}, the autoclave system and the computer system based on the written evaluation report approved by the Designated Government Representative (DGR).

1.3. The autoclave system was originally manufactured and installed in 1984 by Thermal Equipment Corp (TEC), and then later upgraded in 2007 by Taricco corp. The autoclave· system consists of the following;

1.3.1. One (lj 7' natural gas autoclave, model no. 83S3-7, serial no. 250, manufactured by TEC jModel# 8353-7, S/N# 2SO, PEMA# 65888018326).

1.3.2. Onell) Liquid Nitrogen Steam Vaporizer, model no. 10x4, manufactured by Cryogenics Experts tnc.

1.3.3. One (lt TCS Autoclave Control System manufactured by Taricco Corporation utilizin'g multiple Direct Logic (Kayo) PLC chassis and CPU system, one (1) Agilent Technologies model 34980A-LXI Multi-function switch/Measuring Unit {MUX), with three {3) operating consoles.

1.4. The primary Pedod of Performance for the requested services is for a period not to exceed 10 months aftN contract award date.

Z. APPLICABLE DOCUMENTS:

2.1. Taricco !ouch Screen Operation Procedure & Manual

2.2. Cryogenic Expert Inc. (CEXl).Drawing No, B-831214 Rev A

STATEMENT OF WORK

Page 1 of7

6.3.1.1

6.3.1.2

The Contractor shall provide the DGR with a Coe.

The DGR shall review, sign, and provide a signed copy of the Coe to the Contractor prior to departing NAS North lsland.

7. SPECIAL REQUIREMENTS�

7 .1. Base Access:

7 .1.1. The Contractor shall provide the DGR with the full name (first, middle, and last}, date of birth, place of birth, citizenship, and full Social Security Number of each person requiring base access in ordered to facmtate the vetting process required for base access at least ten business {10) days in advance of the scheduled site visit:

7.1.2. Upon arrival, all personnel will be required to check�ln at the Visitor Control Center

(Bldg.680), which is located near the Main Gate to Naval Base Coronado lNBC), NAS

North ls1and, San Diego, CA. Following receipt of a clearance, personnel wlll then be required to coordinate with the DGR and obtain visitor badges through the FRCSW

Quarterdeck, located in Building 94.

Pages of7

STATEMENT OFWORK

File details come from the government source that posted it.