BUILDING
FIELD OFFICE DATE PREPARED BY
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
A-01 001 502
A-04 001 502
A-04 002 502
A-04 003 502
A-04 004 129
A-05A 001 407
A-05A 002 407
A-09A 001 Roof
A-09A 002 Roof
A-11 001 Garage
A-11 002 145
A-11 003 502
A-11 004 502
A-11 005 502
A-13 002
NOT USED
203A
A-13 003
NOT USED
310B
A-13 004
NOT USED
208C
A-13 005 317
A-13 006 105
A-13 007
1st flr Hall by
A-13 008 400
Federal Building, Huron, SD SD0038ZZ
Air compressor, portable, Sears, 1hp
Air compressor, Quincy, 2hp, Air Conditioning Machine, Split System, Special Purpose, Liebert
Corp., 5 Ton, Model BF067A-ASM, S/N 343902-001, R-22 60 lbs, mated with A-09A-001, for WAPA, AO-RWA
DESCRIPTION AND REMARKS
Air compressor, Quincy, 2hp
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
Air compressor, Dry pipe fire sprinklers, C-Aire Model S265H-HD1-
115U, S/N CA201601049, 3.2CFM @ 100psi, 1.5 HP
Air Conditioning Machine, Split System, Special Purpose, Liebert
Corp., 5 Ton, Model BF067A-ASM, S/N 343902-002, R-22 60 lbs, mated with A-09A-002 for WAPA, AO-RWA
Air Cooled Condenser(EAST UNIT), Split System, Special Purpose, Liebert Corp., 5 Ton, Model CSL083LA, S/N 97070710, R-22 60 lbs, mated with A-05A-001, serves 407, WAPA, AO-RWA
Air Cooled Condenser(WEST UNIT), Split System, Special Purpose, Liebert Corp., 5 Ton, Model CSL083LA, S/N 97070709, R-22 60 lbs, mated with A-05A-002, serves 407, WAPA, AO-RWA
Air Handler, McQuay, 10,660 CFM, REMOVED
A/C Unit, Special purpose, Ceiling mounted, Airflow Co.NOT USED
A/C Unit, Special purpose, Ceiling mounted, Airflow Co.NOT USED
A/C Unit, Special purpose, Ceiling mounted, Data AireNOT USED
A/C Unit, Special purpose, Ceiling mounted, Airflow Co., Model SH-
2A3, S/N 86090142, R-22 4.375 lbs, for USDA, AO-RWA
A/C Unit, Special purpose, Ceiling Mounted, Liebert, Model
MM018AX0000, R-22 49 ounces, for SSA, AO-RWA
Air Handler, McQuay, 10,000 CFM, REMOVED
Air Handler, McQuay, 30,720 CFM
Air Handler, McQuay, 33,280 CFM
Air Handler, Trane, Size 6, 2,600 CFM
A/C Unit, Comfort cooling, Ceiling Mounted, Liebert, Model
MM024EX0000, R-22 151 ounces, for WAPA CAD room, AO-RWA
A/C Unit, Comfort Cooling, Ceiling Mounted, Liebert, Model
MM024EX0000, R-22 151 ounces, for SSA computer training room, AO-RWA
GENERAL SERVICES ADMINISTRATION 1 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
AMS 001 131
AMS 002
Exterior West
Side
AMS 003 129
B-02 001 503
B-02 002 503
B-03 001 503
B-03 002 503
B-04 001 503
B-04 002 503
B-07F 001 503
B-07F 002 503
B-08 001 503
B-08 002 503
B-09 001 503
B-09 002 503
C-02 001 501
C-02 002 501
C-02 003 503
C-02 004 503
C-02 005 Garage
C-02 006 145
C-03 001 503
C-04 001 501
C-05 001 1st floor
Advanced Metering System, Electrical
Advanced Metering System, Natural Gas
Advanced Metering System, Water, 2 each ( 1 on Main and 1 on
Lawn Sprinkler System)
Remote Air Intake Dampers, 24.4 Sq. Ft.
Remote Air Dampers, 20 Sq. Ft.
Burner, Oil, Gordon-Piatt, 21.4 gph
Automatic Mixing Box, electric, 2 ea., 4" diam. Inlet
PreHeat coil for Combustion Air Fan, 141 MBtuH, 10GPM, Face Area
31.5in X 30in
Remote Air Intake Dampers, 1 Sq. Ft.
Remote Air Intake Dampers, 4 Sq. Ft.
Central Mini computer, HVAC System
Remote Air Intake Dampers, 10 1/2 Sq. Ft.
Remote Air Intake Dampers, 35 Sq. Ft.
Burner, Gas, Gordon-Piatt
Burner, Gas, Gordon-Piatt
Boiler, Hot Water, Bryan Model CL-300-W-FDGO-LH-GP, S/N
89027, 72 BHP, 2400 MBH output, Oil & Gas
Boiler, Hot Water, Bryan Model CL-300-W-FDGO-LH-GP, S/N
89009, 72 BHP, 2400 MBH output, Oil & Gas
Burner, Oil, Gordon-Piatt, 21.4 gph Boiler Inspection, Internal, Bryan Model CL-300-W-FDGO-LH-
GP,S/N 89009, 72 BHP, 2400 MBH output, Oil & Gas Boiler Inspection, Internal, Bryan Model CL-300-W-FDGO-LH-
GP,S/N 89027, 72 BHP, 2400 MBH output, Oil & Gas
Boiler, Combustion Efficiency test, Bryan Model CL-300-W-FDGO-LH-
GP, S/N 89009, 72 BHP, 2400 MBH output, Oil & Gas Boiler, Combustion Efficiency test, Bryan Model CL-300-W-FDGO-LH-
GP, S/N 89027, 72 BHP, 2400 MBH output, Oil & Gas
Boiler Inspection, External, Bryan Model CL-300-W-FDGO-LH-GP, S/N 89009, 72 BHP, 2400 MBH output, Oil & Gas Boiler Inpsection, External, Bryan Model CL-300-W-FDGO-LH-
GP,S/N 89027, 72 BHP, 2400 MBH output, Oil & Gas
GENERAL SERVICES ADMINISTRATION 2 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
C-05 002 1st floor
C-05 003 1st floor
C-05 004 1st floor
C-05 005 1st floor
C-05 006 1st floor
C-05 007 1st floor
C-05 008 1st floor
C-05 009 2nd floor
C-05 010 2nd floor
C-05 011 2nd floor
C-05 012 2nd floor
C-05 013 2nd floor
C-05 014 3rd floor
C-05 015 3rd floor
C-05 016 3rd floor
C-05 017 3rd floor
C-05 018 3rd floor
C-05 019 3rd floor
C-05 020 4th floor
C-05 021 4th floor
C-05 022 4th floor
C-05 023 4th floor
C-05 024 4th floor
C-06 001 1st floor
C-06 002 2nd floor
Automatic Mixing Box, electric, 1 ea., 14"
Automatic Mixing Box, electric, 1 ea., 5"
Automatic Mixing Box, electric, 7 ea., 6"
Automatic Mixing Box, electric, 7 ea., 8"
Controls Electric, 71 ea.
Controls, Electric, 82 ea.
Automatic Mixing Box, electric, 4 ea., 10"
Automatic Mixing Box, electric, 1 ea., 9"
Automatic Mixing Box, electric, 5 ea., 8"
Automatic Mixing Box, electric, 2 ea., 7"
Automatic Mixing Box, electric, 2 ea., 9"
Automatic Mixing Box, electric, 3 ea., 10"
Automatic Mixing Box, electric, 3 ea., 12"
Automatic Mixing Box, electric, 2 ea., 12"
Automatic Mixing Box, electric, 4 ea., 10"
Automatic Mixing Box, electric, 3 ea., 9"
Automatic Mixing Box, electric, 12 ea., 6"
Automatic Mixing Box, electric, 3 ea., 12"
Automatic Mixing Box, electric, 3 ea., 10"
Automatic Mixing Box, electric, 2 ea., 8"
Automatic Mixing Box, electric, 7 ea., 6"
Automatic Mixing Box, electric, 3 ea., 9"
Automatic Mixing Box, electric, 7 ea., 8"
Automatic Mixing Box, electric, 7 ea., 6"
Automatic Mixing Box, electric, 1 ea., 12"
GENERAL SERVICES ADMINISTRATION 3 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
C-06 003 3rd floor
C-06 004 4th floor
C-06 005 Penthouse
C-06 006 Outside
C-09B 001 Roof
C-09B 002 Roof
C-10B 001 Roof
C-10B 002 Roof
C-30 001
Garage
Northside
C-30 002
Garage
Southside
D-01 001 Garage
D-01 002 Loading Dock
D-01 003 Snack Bar
D-03B 001 Roof
D-03B 002 Garage
D-03B 003
Front Entrance
Canopy Roof
D-04 001 Front Entrance
D-04 002 Front Entrance
D-04 003
1st FL. Mens
Restroom
D-04 004
1st FL.
Womens
D-04 005 Door 143
D-04 006 Door 105 (SSA)
D-04 007 Door 107 (SSA)
D-05A 001 1st floor
D-05A 002 1st floor
Door, Power Operated, Barcol Cam Cation, Standard Lift
Door, Power Operated, Barcol MR Operator
Door, Automatic, Stanley Magic Door, Electric
Doors, Main Entrance, Northwest
Cooling Tower, 90 Ton, Maintenance, Baltimore Aircoil, FXT-115, s/n
96400494
Cooling Tower, 90 Ton, Maintenance, Baltimore Aircoil, FXT-115, s/n
96400495
Controls Electric, 93 ea.
Controls Electric, 80 ea.
Door Power, North American, Electric, Overhead, Rolling
Drains, Roof, 12 ea
Drains, Roof, 3 ea
Door, Automatic, Stanley Magic Door, Electric
Cooling Tower, 90 Ton, Cleaning, Baltimore Aircoil, FXT-115, s/n
96400494
Cooling Tower, 90 Ton, Cleaning, Baltimore Aircoil, FXT-115, s/n
96400495
Controls Electric, 60 ea.
Controls Central Systems, Electric, 22 ea.
Doors, Main Entrance, Southeast, double leaf doors
Door, Automatic, Stanley Magic Door, Electric
Door, Automatic, Stanley Magic Door, Electric
Door, Automatic, Electric, Record Series 6100
Drains, Roof, 2 ea
Carbon Monoxide & Nitrogen Dioxide Detection & Control System, integrated with Building Automation System (BAS)
Carbon Monoxide & Nitrogen Dioxide Detection & Control System, integrated with Building Automation System (BAS)
Door, Automatic, Electric
Door, Automatic, Electric
GENERAL SERVICES ADMINISTRATION 4 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
D-05B 003 1st floor
D-05B 004 1st floor
D-05B 005 1st floor
D-05B 006 1st floor
D-05B 007 1st floor
D-05B 008 1st floor
D-05B 009 143
D-05B 010 Garage
D-06 001 Outside
D-06 002 Garage
E-01 / 12
001 - GSA
Contract Lobby
E-01 / 12
002 - GSA
Contract Lobby
E-01 001 Lobby
E-01 002 Lobby
E-19 001 1st floor
E-19 002 2nd floor
E-19 003 3rd floor
E-19 004 4th floor
E-19 005 Penthouse
E-25 001 131
E-26 001 131
E-26 002 131
E-26 003 131
E-26 004 131
E-26 005 131
Doors, Secondary Entrance, Southeast Lobby
Doors, Secondary Entrance, 2 ea., West Hall
Door, Secondary Entrance, 2 ea., East Hall
Door, Secondary Entrance, 2 ea., Back West
Doors, Secondary Entrance, Northwest Lobby
Drains, Areaway, Driveway, Storm, 4 ea.
Elevator, Hydraulic, Dover, 4 floors
Elevator, Hydraulic, Dover, 4 floors
Elevator, Hydraulic, Dover, 4 floors (O&M - Check Emergency Stop button, Alarm, Door Open, & Emergency Phone)
Door, Secondary Entrance, 2 ea., Back West
Door, Secondary Entrance, 1 ea., West
Door, Secondary Entrance, 1 ea., West
Drains, Areaway, Driveway, Storm, 10 ea.
Ground Fault Type Transformer or Differential Relay, Eaton, Digitrip
RMS310
Low Voltage Molded Case Circuit Breaker, Main Breaker (MSA), 480
Volts, 2000 Amps
Emergency Lighting and Exit Lights with batteries, 9 Ft., 13 ea
Emergency Lighting and Exit Lights with batteries, 9 Ft., 11 ea
Emergency Lighting and Exit Lights with batteries, 9 Ft., 10 ea
Emergency Lighting and Exit Lights with batteries, 9 Ft., 3 ea
Low Voltage Molded Case Circuit Breaker (SPARE), 480 Volts, 600
Amps Low Voltage Molded Case Circuit Breaker (MCCA), 480 Volts, 400
Amps
Low Voltage Molded Case Circuit Breaker (DPHA), 480 Volts, 600
Amps Low Voltage Molded Case Circuit Breaker (DPHB), 480 Volts, 600
Amps
Elevator, Hydraulic, Dover, 4 floors (O&M - Check Emergency Stop button, Alarm, Door Open, & Emergency Phone)
Emergency Lighting and Exit Lights with batteries, 9 Ft., 49 ea
GENERAL SERVICES ADMINISTRATION 5 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
E-26 006 131
E-26 007 131
E-26 008 131
E-27 001 129
E-30A 001 131
E-30A 002 501
E-34 001 Garage
E-34 002 145
E-34 003 Garage
E-34 004 Garage
E-34 005 135A
E-34 006 135A
E-34 007 131
E-34 008 131
E-34 009 131
E-34 010 131
E-34 011 131
E-34 012 131
E-34 013 131
E-34 014 131
E-34 015 502
E-34 016 502
E-34 017 502
E-34 018 502
E-34 019 502
Disconnects (Isolating Switch, per switch), Fuel oil transfer pump for
Emergency Generator Disconnects (Isolating Switch, per switch), Fuel oil transfer pump for
Boilers
Low Voltage Switchboard, 480/277 Volts, 400 Amps, Labeled "EDPA"
Disconnects (Isolating Switch, per switch), 50/50 Glycol pump, Garage heating, NO LONGER IN USE
Low Voltage Molded Case Circuit Breaker (SPARE), 480 Volts, 400
Amps Low Voltage Molded Case Circuit Breaker (ATS1), 480 Volts, 200
Amps Low Voltage Molded Case Circuit Breaker (ATS1), 480 Volts, 100
Amps
Disconnect or Isolating switch (fused/nonfused), 480 Volts, 100
Amps, for Panel “H6”
Low Voltage Power Circuit Breaker, Metron Instruments, Inc., 460
Volts, 50 HP
Low Voltage Switchboard, 480/277 volts, 2000 Amps, Labeled "MSA"
Disconnects (Isolating Switch, per switch), new Garage Exhaust Fans Disconnects (Isolating Switch, per switch), AHU #4, NO LONGER IN
USE
Disconnects (Isolating Switch, per switch), Run-around-coil pump, Garage heating, NO LONGER IN USE Disconnect or Isolating switch (fused/nonfused), 480 Volts, 150
Amps, for Panel “H7” Disconnect or Isolating switch (fused/nonfused), 100 Amps, for Panel
“H2” Disconnect or Isolating switch (fused/nonfused), 480 Volts, 100
Amps, for Panel “H3”
Disconnects (Isolating Switch, per switch), AHU #1
Disconnects (Isolating Switch, per switch), AHU #2
Disconnects (Isolating Switch, per switch), Return Fan #1
Disconnects (Isolating Switch, per switch), Return Fan #2
Disconnects (Isolating Switch, per switch), CHW pump #1
Disconnect or Isolating switch (fused/nonfused), 480 Volts, 100
Amps, for Panel “H8” Disconnect or Isolating switch (fused/nonfused), 480 Volts, 100
Amps, for “ATS2” Disconnect or Isolating switch (fused/nonfused), 480 Volts, 60 Amps, for “Power Factor Correction Capacitors” Disconnect or Isolating switch (fused/nonfused), 480 Volts, 45 Amps, for Transformer “X-LC”
GENERAL SERVICES ADMINISTRATION 6 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
E-34 020 502
E-34 021 502
E-34 022 502
E-34 023 502
E-34 024 502
E-34 025 502
E-34 026 502
E-34 027 502
E-34 028 502
E-34 029 503
E-34 030 503
E-34 031 503
E-34 032 503
E-34 033 503
E-34 034 503
E-34 035 503
E-34 036 503
E-34 037 503
E-34A 001 131
E-34A 002 131
E-34A 003 131
E-34A 004 131
E-34A 005 131
E-34A 006 502
E-34A 007 502
Disconnect or Isolating switch (fused/nonfused), 480 Volts, 200
Amps, for “ATS1”
Disconnects (Isolating Switch, per switch), HW pump #2
Disconnects (Isolating Switch, per switch), HW pump #5
Disconnects (Isolating Switch, per switch), HW pump #6
Disconnects (Isolating Switch, per switch), HW pump #4
Disconnect or Isolating switch (fused/nonfused), 480 Volts, 600
Amps, for “MCCA”
Disconnects (Isolating Switch, per switch), CHW pump #2 Disconnects (Isolating Switch, per switch), Condenser Water pump
#1 Disconnects (Isolating Switch, per switch), Condenser Water pump
#2
Disconnects (Isolating Switch, per switch), AHU #1 CHW Coil pump
Disconnects (Isolating Switch, per switch), AHU #2 CHW Coil pump
Disconnects (Isolating Switch, per switch), Makeup Air Fan
Disconnects (Isolating Switch, per switch), Air compressor
Disconnects (Isolating Switch, per switch), Cooling Tower #1 Fan
Disconnects (Isolating Switch, per switch), Combustion Air Fan
Disconnects (Isolating Switch, per switch), Boiler #1
Disconnect or Isolating switch (fused/nonfused), 480 Volts, 200
Amps, for Panel “H1”
Disconnects (Isolating Switch, per switch), Boiler #2
Disconnect or Isolating switch (fused/nonfused), 480 Volts, 200
Amps, for Panel “H4” Disconnect or Isolating switch (fused/nonfused), 480 Volts, 200
Amps, for Panel “H5”
Disconnect or Isolating Switch, fused/nonfused, 200 amps and up, Labeled “CH -2” for Chiller 2, located in “MCCA”
Disconnect or Isolating Switch, fused/nonfused, 200 amps and up, Labeled “CH -1” for Chiller 1, located in “MCCA”
Disconnects (Isolating Switch, per switch), HW pump #3
Disconnects (Isolating Switch, per switch), Cooling Tower #1 Fan
Disconnects (Isolating Switch, per switch), HW pump #1
GENERAL SERVICES ADMINISTRATION 7 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
E-34A 008 501
E-35 001 502
E-35 002 503
E-36 001 501
E-36 002 501
E-41 001 501
E-41A 001 501
E-42 001 501
E-42A 001 501
E-42B 001 501
E-42C 001 501
E-43B 001 501
E-43B 002 136
E-43B 004 501
E-43B 005 135
E-43B 006 101
E-51 001 Garage
E-51 002 Garage
E-51 003 Loading Dock
E-51 004 503
E-51 005 503
E-51 006 503
E-51 007 503
E-51 008 503
E-51 009 503
Battery, Sealed type (Gell Cell), Fire Alarm Voice Evac Panel with microphone, Silent Knight SKE450ZN4
Motor Starter, Less than 100 HP, MCCB, HW pump #2
Motor Starter, Less than 100 HP, MCCB, HW pump #3
Motor Starter, Less than 100 HP, MCCB, HW pump #4
Automatic Transfer Switch, "ATS2", feeds Panel "EMHA"
Motor Starter, Less than 100 HP, Exhaust Fan #1 for Garage, 2 HP
Motor Starter, Less than 100 HP, Exhaust Fan #2 for Garage, 1/4 HP
Emergency Generator, Diesel, Caterpillar, 277 HP, 194 KVA, 155
KW, 3 Phase, 480 Volt Emergency Generator, Diesel, Caterpillar, 277 HP, 194 KVA, 155
KW, 3 Phase, 480 Volt Emergency Generator, Diesel, Caterpillar, 277 HP, 194 KVA, 155
KW, 3 Phase, 480 Volt Emergency Generator, Diesel, Caterpillar, 277 HP, 194 KVA, 155
KW, 3 Phase, 480 Volt
Emergency Generator, Diesel
Emergency Generator, Diesel
Disconnect or Isolating Switch, fused/nonfused, 200 amps and up, Labeled “MCCB”, located in Emergency Distribution Panel “EDPA”
Battery, Sealed type (Gell Cell), Keycard System
Motor Starter, Less than 100 HP, MCCB, HW pump #6
Motor Starter, Less than 100 HP, Dock Lift
Motor Starter, Less than 100 HP, MCCB, HW pump #5
Motor Control Center, under 100 HP, Labeled "MCCB", 8 starters, 1 disconnect (for transformer LPA)
Motor Control Center, under 100 HP, Labeled "MCCA", 9 starters, 4 disconnects
Motor Starter, Less than 100 HP, MCCB, HW pump #1
Battery, Sealed type (Gell Cell), Building Automation System, Niagara
AX JACE (Network Controller)
Automatic Transfer Switch, Zenith 480, "ATS1", feeds Switchboard
"EDPA"
Battery, Sealed type (Gell Cell), Fire Alarm Panel & 2 NAC Panels
Battery, Sealed type (Gell Cell), Autodialer, Boiler Alarm
GENERAL SERVICES ADMINISTRATION 8 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
E-51 010 503
E-51 011 502
E-51 012 502
E-51 013 502
E-51 014 502
E-51 015 502
E-51 016 502
E-51 017 502
E-51 018 502
E-51 019 502
E-51 020 502
E-51 021 502
E-51 022 502
E-51 023 502
E-51 024 502
E-51 025 502
E-51 026 502
E-51 027 129
E-51 028 129
E-51 029 129
E-57 001 117
E-57 002 128
E-57 003 211
E-57 004 214
E-57 005 311
Low voltage, Dry Type Transformer, Acme Electric, 3 Phase, 60 HZ, 75 KVA, 480V, 208V, 120V
Low voltage, Dry Type Transformer, Acme Electric, 3 Phase, 60 HZ, 75 KVA, 480V, 208V, 120V
Low voltage, Dry Type Transformer, Acme Electric, 3 Phase, 60 HZ, 45 KVA, 480V, 208V, 120V
Motor Starter, Less than 100 HP, Return Fan #1
Motor Starter, Less than 100 HP, Return Fan #2
Motor Starter, Less than 100 HP, CHW pump #1
Motor Starter, Less than 100 HP, CHW pump #2
Motor Starter, Less than 100 HP, Chiller #1
Motor Starter, Less than 100 HP, Condenser Water pump #1
Motor Starter, Less than 100 HP, Condenser Water pump #2
Motor Starter, Less than 100 HP, AHU #1 CHW Coil pump
Motor Starter, Less than 100 HP, AHU #2 CHW Coil pump
Motor Starter, Less than 100 HP, Combustion Air Fan
Motor Starter, Less than 100 HP, MCCA, Cooling Tower #2 Fan
Low voltage, Dry Type Transformer, Acme Electric, 3 Phase, 60 HZ, 45 KVA, 480V, 208V, 120V
Low voltage, Dry Type Transformer, Acme Electric, 3 Phase, 60 HZ, 75 KVA, 480V, 208V, 120V
Motor Starter, Less than 100 HP, AHU #2
Motor Starter, Less than 100 HP, Air Compressor
Motor Starter, Less than 100 HP, Domestic Water Booster pumps
Motor Starter, Less than 100 HP, MCCA, Cooling Tower #1 Fan
Motor Starter, Less than 100 HP, Chiller #2
Moto Starter, Less than 100 HP, Fire Pump, Metron, Model MP300-
50-480C, s/n 23583148, 50 HP Motor Starter, Less than 100 HP, Jockey Pump, Tornatech Inc., Model JP3-460/1.5/3/60, s/n Z144044, 1.5 HP
Motor Starter, Less than 100 HP, Makeup Air Fan
Motor Starter, Less than 100 HP, AHU #1
GENERAL SERVICES ADMINISTRATION 9 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
E-57 006 314
E-57 007 412
E-57 008 413
E-57 009 501
E-57 010
407 above the ceiling
E-57 011 503
F-01 001 129
F-01A 001 129
F-02 001 129
F-02A 001 129
F-02B 001 129
F-03 001
Outside
West
F-04 001 129
F-04 002 129
F-04 003 129
F-04 004 129
F-04 005 129
F-04 006 129
F-04 007 129
F-04 008 129
F-04A 001 129
F-04A 002 129
F-04A 003 129
F-04A 004 129
F-04A 005 129
Fire Control Valves, Nibco Scott, 6", discharge side of Backflow
Preventer Fire Control Valves, Nibco Scott, 6", Fire Pump Bypass line on supply side of check valve Fire Control Valves, Nibco Scott, 6", Fire Pump Bypass line on discharge side of check valve
Fire Control Valves, Nibco Scott, 4", to building wet system
Alarm Check Valves and Accessories, Water Pressure, 100 PSI, Check Valve With Jockey Pump, 5 each
Fire Post Indicator Valve, Type, Nibco-NIP-1, 6"
Fire Control Valves, Nibco Scott, 4", to building wet system
Low voltage, Dry Type Transformer, Acme Electric, 3 Phase, 60 HZ, 75 KVA, 480V, 208V, 120V
Low voltage, Dry Type Transformer, Acme Electric, 3 Phase, 60 HZ, 45 KVA, 480V, 208V, 120V
Low voltage, Dry Type Transformer, Acme Electric, 3 Phase, 60 HZ, 30 KVA, 480V, 208V, 120V
Alarm Check Valves and Accessories, Water Pressure, 100 PSI, Check Valve With Jockey Pump, 5 each
Low voltage, Dry Type Transformer, Acme Electric, 3 Phase, 60 HZ, 75 KVA, 480V, 208V, 120V
Dry Pipe Valve, Fire Sprinkler System for Garage and Dock, Tyco
Model DPV1, 3 inch Dry Pipe Valve, Fire Sprinkler System for Garage and Dock, Tyco
Model DPV1, 3 inch Dry Pipe Valve, Fire Sprinkler System for Garage and Dock, Tyco
Model DPV1, 3 inch
Fire Control Valves, Nibco Scott, 6", supply side of Backflow
Preventer
Fire Control Valves, Nibco Scott, 6", supply side of Backflow
Preventer Fire Control Valves, Nibco Scott, 6", discharge side of Backflow
Preventer Fire Control Valves, Nibco Scott, 6", Fire Pump Bypass line on supply side of check valve Fire Control Valves, Nibco Scott, 6", Fire Pump Bypass line on discharge side of check valve
Low voltage, Dry Type Transformer, 3 Phase, 60 HZ, 15 KVA, 480V/208 - 120V
Low voltage, Dry Type Transformer, Acme Electric, 3 Phase, 60 HZ, 30 KVA, 480V, 208V, 120V
Fire Control Valve, 6", Fire Pump suction
Fire Control Valve, 6", Fire Pump flow test connection line
Fire Control Valve, 6", Fire Pump discharge
GENERAL SERVICES ADMINISTRATION 10 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
F-04A 006 129
F-04A 007 129
F-04A 008 129
F-04B 001 129
F-04B 002 129
F-04B 003 129
F-04B 004 129
F-04B 005 129
F-04B 006 129
F-04B 007 129
F-04B 008 129
F-06 001 129
F-06 002 129
F-06A 001 129
F-06A 002 129
F-06B 001 129
F-06B 002 129
F-09 001 Garage
F-09 002 1st floor
F-09 003 1st floor
F-09 004 1st floor
F-09 005 1st floor
F-09 006 2nd floor
Fire Control Valves, Nibco Scott, 6", Fire Pump Bypass line on discharge side of check valve
Fire Pump (electric motor driven) Marathon Motor 50 HP, 500 GPM, rated head 231.141 feet, Pentair Pump Size 3-481-10, s/n 15-245707
Fire Pump (Electric Motor Diven Jockey Pump), Pentair/Aurora Size
PVM1-12 s/n 15-2457019, 1.5 HP, 480 Volt
Fire Pump (electric motor driven) Marathon Motor 50 HP, 500 GPM, rated head 231.141 feet, Pentair Pump Size 3-481-10, s/n 15-245707
Fire Control Valves, Nibco Scott, 6", supply side of Backflow
Preventer
Fire Control Valves, Nibco Scott, 6", Fire Pump Bypass line on supply side of check valve
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Pump (Electric Motor Diven Jockey Pump), Pentair/Aurora Size
PVM1-12 s/n 15-2457019, 1.5 HP, 480 Volt
Fire Pump (electric motor driven) Marathon Motor 50 HP, 500 GPM, rated head 231.141 feet, Pentair Pump Size 3-481-10, s/n 15-245707
Fire Pump (Electric Motor Diven Jockey Pump), Pentair/Aurora Size
PVM1-12 s/n 15-2457019, 1.5 HP, 480 Volt
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Control Valves, Nibco Scott, 6", discharge side of Backflow
Preventer
Fire Control Valves, Nibco Scott, 4", to building wet system
Fire Control Valves, 6", Fire Pump suction
Fire Control Valves, 6", Fire Pump flow test connection line
Fire Control Valves, 6", Fire Pump discharge
Fire Control Valves, 6", Fire Pump suction
Fire Control Valves, 6", Fire Pump discharge
Fire Control Valve, 6", Fire Pump flow test connection line
GENERAL SERVICES ADMINISTRATION 11 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
F-09 007 2nd floor
F-09 008 2nd floor
F-09 009 2nd floor
F-09 010 3rd floor
F-09 011 3rd floor
F-09 012 3rd floor
F-09 013 3rd floor
F-09 014 4th floor
F-09 015 4th floor
F-09 016 4th floor
F-09 017 4th floor
F-09 018 Penthouse
F-09 019 Penthouse
F-09 020 Penthouse
F-09 021 Penthouse
F-09A 001 Garage
F-09A 002 1st floor
F-09A 003 1st floor
F-09A 004 1st floor
F-09A 005 1st floor
F-09A 006 2nd floor
F-09A 007 2nd floor
F-09A 008 2nd floor
F-09A 009 2nd floor
F-09A 010 3rd floor
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
GENERAL SERVICES ADMINISTRATION 12 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
F-09A 011 3rd floor
F-09A 012 3rd floor
F-09A 013 3rd floor
F-09A 014 4th floor
F-09A 015 4th floor
F-09A 016 4th floor
F-09A 017 4th floor
F-09A 018 Penthouse
F-09A 019 Penthouse
F-09A 020 Penthouse
F-09A 021 Penthouse
F-10 001
Exterior
North Side
F-10 002
Exterior West
Side
F-11 001 1st floor
F-11 002 2nd floor
F-11 003 3rd floor
F-11 004 4th floor
F-11 005 Penthouse
F-13 001 129
F-13 002 129
F-13 003 129
F-13 004 129
F-13 005 129
F-13 006 129
F-13 007 129
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Doors, Stairwells & Exitway (Swinging), 2 ea.
Fire Doors, Stairwells & Exitway (Swinging), 2 ea.
Fire Doors, Stairwells & Exitway (Swinging), 4 ea.
Fire Doors, Stairwells & Exitway (Swinging), 4 ea.
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Department Hose Connections, Larsens, 2-1/2"
Fire Supervisory Signal-Testing, Tamper Switch (Fire Main supply valve to Garage and Dock Dry System)
Fire Department Pumper Connection, Sprinkler, Elkhart, 3" Fire Department Pumper Connection, Sprinkler, 3", for Fire Pump flow test
Fire Doors, Stairwells & Exitway (Swinging), 20 ea.
Fire Supervisory Signal-Testing, Tamper Switch (Supply valve -
Jockey pump suction) Fire Supervisory Signal-Testing, Tamper Switch (Valve - Jockey pump discharge)
Fire Supervisory Signal-Testing, Tamper Switch, 2 each, (Fire Main
Supply backflow preventer)
Fire Supervisory Signal-Testing, Tamper Switch (Fire Main valve -
Fire Pump suction)
Fire Supervisory Signal-Testing, Tamper Switch, 2 each (Fire Main valve - Fire Pump Bypass)
Fire Supervisory Signal-Testing, Tamper Switch (Fire Main valve -
Fire Pump discharge)
GENERAL SERVICES ADMINISTRATION 13 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
F-13 008
Outside
West
F-13 009 129
F-14 001 1st Lobby
F-14 002 2nd Lobby
F-14 003 3rd Lobby
F-14 004 4th Lobby
F-14 005 407
F-14 006 407
F-14 007 407
F-14 008 407
F-14 009 Penthouse
F-14 010 Penthouse
F-14 011 Penthouse
F-14 012 Penthouse
F-14 013
Elevator Mach.
Rm.
F-14A 001 129
F-14A 002 129
F-14A 003 2nd Lobby
F-14A 004 2nd Lobby
F-14A 005 3rd Lobby
F-14A 006 3rd Lobby
F-14A 007 4th Lobby
F-14A 008 4th Lobby
F-14A 009 Penthouse
F-14A 010
Elevator Mach.
Rm.
Automatic Fire Detection or Alarm Devices, Smoke
Automatic Fire Detection or Alarm Devices, Smoke
Automatic Fire Detection or Alarm Devices, Smoke
Fire Supervisory Signal-Testing, Tamper Switch, Post indicator valve
Automatic Fire Detection or Alarm Devices, Ionization
Automatic Fire Detection or Alarm Devices, Ionization
Automatic Fire Detection, Waterflow Alarms
Automatic Fire Detection, Waterflow Alarms (Dry pipe system)
Automatic Fire Detection or Alarm Devices, Smoke
Automatic Fire Detection or Alarm Devices, Smoke
Automatic Fire Detection or Alarm Devices, Smoke
Automatic Fire Detection or Alarm Devices, Ionization
Automatic Fire Detection or Alarm Devices, Ionization
Automatic Fire Detection or Alarm Devices, Smoke
Automatic Fire Detection or Alarm Devices, Smoke
Automatic Fire Detection or Alarm Devices, Smoke
Fire Supervisory Signal-Testing, Low Air Pressure (Dry pipe system)
Automatic Fire Detection, Waterflow Alarms
Automatic Fire Detection, Waterflow Alarms
Automatic Fire Detection, Waterflow Alarms
Automatic Fire Detection, Waterflow Alarms
Automatic Fire Detection, Waterflow Alarms
Automatic Fire Detection, Waterflow Alarms
Automatic Fire Detection, Waterflow Alarms
Automatic Fire Detection, Waterflow Alarms
GENERAL SERVICES ADMINISTRATION 14 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
F-14B 001
Elevator Mach.
Rm.
F-14B 002 501
F-15 001 100
F-15 002 501
F-15 003 501
F-15 004 501
F-15B 001 501
F-15B 002 136
F-16B 001 100
F-17 001 Garage
F-17 002
1st Floor
Back Hall
F-17 003 105
F-17 004 Stairwell 1
F-17 005 Stairwell 2
F-17 006 Lobby
F-17 007 Lobby
F-17 008 106
F-17 009 106A
F-17 010 2nd Lobby
F-17 011 2nd Lobby
F-17 012 3rd Lobby
F-17 013 3rd Lobby
F-17 014 4th Lobby
F-17 015 4th Lobby
F-17 016 501
Fire Alarm Control Panel, Silent Knight 5808
Fire Alarm Box, Manual, Addressable, Silent Knight
Fire Alarm Control Panel, Silent Knight 5495, Distributed Power
Module Fire Alarm Control Panel, Silent Knight 5495, Distributed Power
Module
Fire Alarm Box, Manual, Addressable, Silent Knight
Fire Alarm Box, Manual, Addressable, Silent Knight
Fire Alarm Box, Manual, Addressable, Silent Knight
Fire Alarm Box, Manual, Addressable, Silent Knight
Fire Alarm Box, Manual, Addressable, Silent Knight
Fire Alarm Box, Manual, Addressable, Silent Knight
Fire Alarm Box, Manual, Addressable, Silent Knight
Fire Alarm Box, Manual, Addressable, Silent Knight
Fire Alarm control Panel, Annunciator Panel, Silent Knight 5860R
Fire Alarm System, Audio Control Panel, Voice Evacuation System with microphone, Silent Knight SKE450ZN4
Automatic Fire Detection, Heat detector
Automatic Fire Detection, Heat detector
Central Station, Transmitter, Fire Alarm, Autodialer integrated with
Silent Knight Fire Alarm Control Panel
Central Station, Transmitter, Boiler Alarm
Fire Alarm Box, Manual, Addressable, Silent Knight
Fire Alarm Box, Manual, Addressable, Silent Knight
Fire Alarm Box, Manual, Addressable, Silent Knight
Fire Alarm Box, Manual, Addressable, Silent Knight
Fire Alarm Box, Manual, Addressable, Silent Knight
Fire Alarm Box, Manual, Addressable, Silent Knight
Fire Alarm Box, Manual, Addressable, Silent Knight
GENERAL SERVICES ADMINISTRATION 15 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
F-17 017 503
F-18 001 111
F-18 002 111
F-18 003 111
F-18 004 122
F-18 005 122
F-18 006 122
F-18 007 122
F-18 008 211
F-18 009 211
F-18 010 211
F-18 011 211
F-18 012 212
F-18 013 212
F-18 014 212
F-18 015 212
F-18 016 311
F-18 017 311
F-18 018 311
F-18 019 311
F-18 020 314
F-18 021 314
F-18 022 314
F-18 023 314
F-18 024 412
Fire Alarm Box, Manual, Addressable, Silent Knight
Fire Dampers, Thermal Fusible Link, 24" 0
Fire Dampers, Thermal Fusible Link, 20" 0
Fire Dampers, Thermal Fusible Link, 12 x 8
Fire Dampers, Thermal Fusible Link, 9 x 6
Fire Dampers, Thermal Fusible Link, 40 x 20
Fire Dampers, Thermal Fusible Link, 19" 0
Fire Dampers, Thermal Fusible Link, 9 x 6
Fire Dampers, Thermal Fusible Link, 40 x 20
Fire Dampers, Thermal Fusible Link, 40 x 24
Fire Dampers, Thermal Fusible Link, 24" 0
Fire Dampers, Thermal Fusible Link, 12 x 10
Fire Dampers, Thermal Fusible Link, 12 x 8
Fire Dampers, Thermal Fusible Link, 40 x 24
Fire Dampers, Thermal Fusible Link, 23" 0
Fire Dampers, Thermal Fusible Link, 12 x 8
Fire Dampers, Thermal Fusible Link, 9 x 6
Fire Dampers, Thermal Fusible Link, 40 x 24
Fire Dampers, Thermal Fusible Link, 16 x 10
Fire Dampers, Thermal Fusible Link, 12 x 10
Fire Dampers, Thermal Fusible Link, 40 x 20
Fire Dampers, Thermal Fusible Link, 23" 0
Fire Dampers, Thermal Fusible Link, 12 x 10
Fire Dampers, Thermal Fusible Link, 12 x 8
Fire Dampers, Thermal Fusible Link, 40 x 24
GENERAL SERVICES ADMINISTRATION 16 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
F-18 025 412
F-18 026 412
F-18 027 413
F-18 028 413
F-18 029 413
F-18 030 502
F-18 031 502
F-18 032 502
F-18 033 502
F-20 001 1st floor
F-20 002 2nd floor
F-20 003 3rd floor
F-20 004 4th floor
F-20 005 Penthouse
F-22 001 1st floor
F-22 002 2nd floor
F-22 003 3rd floor
F-22 004 4th floor
F-22 005 5th floor
F-22A 001 Building
F-24 001 Building
F-25B 001 1st floor
F-25B 002 2nd floor
F-25B 003 3rd floor
F-25B 004 4th floor
Fire Extinguisher, Stored Pressure with Guage, 22 ea (2 - 20lb, 20 -
10lb)
Fire Extinguisher, Stored Pressure with Guage, 10 Lbs., 8 ea
(Southeast End), Fire Dampers, Thermal Fusible Link, 48 x 48
Sprinkler Heads, 27,477 Sq. Ft., approx. 147 heads
Sprinkler Heads, 19,400 Sq. Ft., approx. 104 heads
Sprinkler Heads, 19,400 Sq. Ft., approx. 104 heads
(Northwest End), Fire Dampers, Thermal Fusible Link, 40" 0
(Northwest End), Fire Dampers, Thermal Fusible Link, 48 x 48
Sprinkler Heads, 19,400 Sq. Ft., approx. 104 heads
Sprinkler Heads, 3,330 Sq. Ft., approx. 18 heads
(Southeast End), Fire Dampers, Thermal Fusible Link, 40" 0
Fire Extinguisher, Monthly Inspection, 50 ea (1 of these belongs to
SSA in Room 105)
Fire Extinguisher, Stored Pressure with Guage, 10 Lbs., 9 ea
Fire Extinguisher, Stored Pressure with Guage, 10 Lbs., 7 ea
Fire Extinguisher, Non-Stainless Steel, 49 ea. (5 - 20lb, 44 - 10lb)
Fire Extinguisher, Stored Pressure with Gauge, 9 ea
Fire Extinguisher, Stored Pressure with Gauge, 8 ea
Fire Dampers, Thermal Fusible Link, 24" 0
Fire Dampers, Thermal Fusible Link, 14 x 10
Fire Dampers, Thermal Fusible Link, 40 x 24
Fire Dampers, Thermal Fusible Link, 23" 0
Fire Dampers, Thermal Fusible Link, 12 x 10
Fire Extinguisher, Stored Pressure with Guage, 20 Lbs., 3 ea
Fire Extinguisher, Stored Pressure with Gauge, 7 ea
Fire Extinguisher, Stored Pressure with Gauge, 22 ea
GENERAL SERVICES ADMINISTRATION 17 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
F-25B 005 5th floor
F-27 001 503
F-27 002 Roof
F-27 003 501
F-27 004 119
F-27 005 139
F-27 006 502
F-27 007 502
F-27 008 Garage
F-27 009 Garage
F-27 010 Roof
F-27 011 Roof
F-27 012 Roof
F-32 001 Garage
F-32 002 145
F-32 003 1st floor
F-32 004 1st floor
F-32 005 1st floor
F-32 006 2nd floor
F-32 007 2nd floor
F-32 008 3rd floor
F-32 009 3rd floor
F-32 010 4th floor
F-32 011 4th floor
Fan, Centrifugal, 420 CFM, 1147 RPM, Twin City Fan, Model BSI, Size 100A, Motor 1/4 HP, 115 Volt, 1750 RPM, Installed 11/2016
Filter, Throw Away, 14-7/8"x17-3/8"x1", (U.H.), 4 ea.
(Perimeter VAV) Filter, Throw Away, 23"x19-7/8"x1", (U.H.), 1 ea.
(Perimeter VAV)
Filter, Throw Away, 14-7/8"x17-3/8"x1", (U.H.), 6 ea.
(Perimeter VAV)
Filter, Throw Away, 14-7/8"x17-3/8"x1", (U.H.), 7 ea.
(Perimeter VAV)
Filter, Throw Away, 14-7/8"x17-3/8"x1", (U.H.), 3 ea.
(Perimeter VAV)
Fan, Centrifugal, Return Air #2, Size 49, 25,240 CFM, McQuay, 15
HP
Fan, Centrifugal, 50 CFM, Loren Cook, .07 HP, Penthouse Restroom
Fan, Centrifugal, 315 CFM, Loren Cook, 1/25 HP
Fan, Centrifugal, 250 CFM, Loren Cook, 1/25 HP Fan, Centrifugal, Return Air #1, Size 49, 23,010 CFM, McQuay, 15
HP
Fan, Centrifugal, 2400 CFM, Borg Warner, 1/4 HP
Fan, Centrifugal, 1920 CFM, Loren Cook, 1/4 HP
Filter, Throw Away, Drico, 2" x 14" x 18", (AH-3), 12 ea., REMOVED
Filter, Throw Away, Drico, 2" x 14" x 18", (AH-4), 12 ea., REMOVED Filter, Throw Away, 10-7/8"x13-7/8"x1", (U.H.), 6 ea.
(Perimeter VAV)
Filter, Throw Away, 10-7/8"x13-7/8"x1", (U.H.), 9 ea.
(Perimeter VAV)
Filter, Throw Away, 10-7/8"x13-7/8"x1", (U.H.), 8 ea.
(Perimeter VAV)
Filter, Throw Away, 10-7/8"x13-7/8"x1", (U.H.), 11 ea.
(Perimeter VAV)
Fan, Centrifugal, 6250 CFM, 465 RPM, Twin City Fan, Model TCLB, Size 330A1, Motor 2 HP, 460 Volt, 3 phase, 1750 RPM, Installed
11/2016 Fan, Centrifugal, Loren Cook, .75 HP, 120 volt, Variable speed
Electrically Commutated Motor, 300-1725 RPM, 2500 CFM, EF5 Fan, Centrifugal, Loren Cook, .75 HP, 120 volt, Variable speed
Electrically Commutated Motor, 300-1725 RPM, 2500 CFM, EF6 Fan, Centrifugal, Loren Cook, .75 HP, 120 volt, Variable speed
Electrically Commutated Motor, 300-1725 RPM, 2500 CFM, EF7
Fire Extinguisher, Stored Pressure with Gauge, 3 ea
GENERAL SERVICES ADMINISTRATION 18 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
F-32 012 502
F-32 013 502
F-34A SC 001 136
F-34A SC 002 1st floor
F-34A SC 003 2nd floor
F-34A SC 004 3rd floor
F-34A SC 005 4th floor
F-34A SC 006 Penthouse
F-34A SC 007 1st floor
F-34A SC 008 2nd floor
F-34A SC 009 1st floor
F-34A SC 010 2nd floor
F-34A SC 011 3rd floor
F-34A SC 012 4th floor
F-34A SC 013 1st floor
F-34A SC 014 2nd floor
F-34A SC 015 3rd floor
F-38 001 Roof
F-49 001 502
F-100 001 135
G-01 001 503
G-01 002 503
G-03 001
Outside - Lease
Lot
G-03 002
Outside -
Government Lot
H-01 001 135A
Hot Water Converter, 762 MBH, 88 GPM Tube, 76.2 GPM Shell NO
LONGER IN USE
Fluorescent, 1 Tube, Industrial Lamp, 48", Metalux, 15 ea.
Fluorescent, 2 Tube, Industrial Lamp, 48", Metalux, 15 ea.
Fluorescent, 2 Tube, Industrial Lamp, 48", Metalux, 3 ea.
Filter, Throw Away, 20X20X2, 48 ea., AHU #1
Filter, Throw Away, 20X20X2, 48 ea., AHU #2
Gates, Security and Access, 2 ea.
Gates, Security and Access, 2 ea.
Fluorescent, 2 Tube, Industrial Lamp, 48", Metalux, 2 ea.
Fluorescent, 2 Tube, Industrial Lamp, 48", Metalux, 4 ea.
Fluorescent, 2 Tube, Industrial Lamp, 48", Metalux, 23 ea.
Fluorescent, 4 Tube, Industrial Lamp, 48", Metalux, 3 ea.
Fluorescent, 2 Tube, Diffuser Lamps, 48", Williams, 321 ea.
Fluorescent, 4 Tube, Diffuser Lamps, 48", Williams, 21 ea.
Fluorescent, 4 Tube, Diffuser Lamps, 48", Williams, 12 ea.
Fluorescent, 4 Tube, Diffuser Lamps, 48", Williams, 14 ea.
Fluorescent, 4 Tube, Industrial Lamp, 48", Metalux, 1 ea.
Fluorescent, 2 Tube, Diffuser Lamps, 48", Williams, 258 ea.
Fluorescent, 2 Tube, Diffuser Lamps, 48", Williams, 326 ea.
Fluorescent, 2 Tube, Diffuser Lamps, 48", Williams, 309 ea.
Lighting Protection, Down Conductors, 23 ea.
Filter control Air, Siemens/Powers 908-042
Fuel Oil Filter/Strainer, Boiler #1, Parker Hannifin Corp
Evacuation Chair, FERNO, Model 59-T, s/n 08-093052
Fuel Oil Filter/Strainer, Boiler #2, Parker Hannifin Corp.
GENERAL SERVICES ADMINISTRATION 19 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
H-01 002 503
H-03 001 124
H-03 002 204
H-03 003 304
H-03 004 404
H-15 001 Penthouse
I-04 001
1st floor elevator lobby
I-04 002
1st floor elevator lobby
L-01 001 Garage
L-01 002 Garage
L-01 003 Garage
L-01 004 Garage
L-01 005 Garage
L-02 001
Outside
SW Corner
L-03 001 1st floor
L-03 002 2nd floor
L-03 003 3rd floor
L-03 004 4th floor
L-03 005 1st floor
L-03 006 300 & 301
L-03 007 400 & 401
L-04B 001 Outside
L-04B 002 Outside
L-04B 003 Outside
L-04B 004 Outside
Hot Water Heater, Electric, 40 Gallons
Hot Water Heater, Electric, 40 Gallons
Lawn Edger, gas powered
Leaf Blower, gas powered
Lighting, Outside, Mercury Vapor, Crouse-Hinds, 24' High, Double Lights Lighting, Outside, Mercury Vapor, Crouse-Hinds, 24' High, Double Lights Lighting, Outside, Mercury Vapor, Crouse-Hinds, 24' High, Double Lights
Lighting, Special Fixtures, Flourescent, 2 Tube, Diffuser Lamps, 36", 2 ea.
Lighting, Special Fixtures, Incandescent, Recessed with Dimmers, 9'
High, Altair, 4 ea.
Lighting, Special Fixtures, Incandescent, Recessed with Dimmers, 9'
High, Altair, 4 ea.
Lighting, Outside, Mercury Vapor, Crouse-Hinds, 24' High, Double Lights
Lighting, Special Fixtures, Incandescent, Recessed Spots with
Diffusers and Dimmers, 10' High, 13 ea.
Lighting, Special Fixtures, Incandescent, Recessed Spots with
Diffusers and Dimmers, 10' High, 7 ea.
Lighting, Special Fixtures, Incandescent, Recessed Spots with
Diffusers and Dimmers, 10' High, 8 ea.
Hoist, Electric, Coffing, Model TG-10 P, 1/2 Ton
Fan/Coil Unit, Ceiling Hung w/Disposable Filter
Fan/Coil Unit, Ceiling Hung w/Disposable Filter
Loading Ramp, 20,000 Lbs.
Lawn Mower, Push type, gas powered
Lawn Edger, Weed eater, gas powered
Hot Water Heater, Electric, 40 Gallons
Hot Water Heater, Electric, 30 Gallons
Lighting, Special Fixtures, Incandescent, Recessed Spots with
Diffusers and Dimmers, 10' High, 8 ea.
Lawn mower, tractor mounted for John Deere LT155
Hot Water Converter, 1153 MBH, 78 GPM Tube, 78.8 GPM Shell
GENERAL SERVICES ADMINISTRATION 20 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
L-04B 005 Outside
L-04B 006 Outside
L-04B 007
Outside
Under Canopy
L-04B 008
Outside
Under Canopy
L-04B 009
Outside
Under Canopy
L-04B 010
Outside
Under Canopy
L-04B 011
Outside
Under Canopy
L-04B 012
Outside
Under Canopy
L-04B 013
Garage
Ceiling
L-04B 014
Garage
Ceiling
L-04B 015
Garage
Ceiling
L-04B 016
Garage
Ceiling
L-04B 017
Garage
Ceiling
L-04B 018
Garage
Ceiling
L-04B 019
Garage
Ceiling
L-04B 020
Garage
Ceiling
L-04B 021
Garage
Ceiling
L-04B 022
Garage
Ceiling
L-04B 023
Garage
Ceiling
L-04B 024
Garage
Ceiling
L-04B 025
Garage
Ceiling
L-04B 026
Garage
Ceiling
L-04B 027
Garage
Ceiling
L-04B 028 Outside
L-04B 029 Outside
Lighting, Sodium Vapor, GE, 10' High
Lighting, Sodium Vapor, GE, 10' High
Lighting, Sodium Vapor, GE, 10' High
Lighting, Sodium Vapor, GE, 10' High
Lighting, Sodium Vapor, GE, 10' High
Lighting, Sodium Vapor, GE, 10' High
Lighting, Outside, Mercury Vapor, Crouse-Hinds, 24' High, Double Lights
Lighting, Sodium Vapor, GE, 10' High
Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 12' High
Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 12' High
Lighting, Sodium Vapor, GE, 10' High
Lighting, Sodium Vapor, GE, 10' High
Lighting, Sodium Vapor, GE, 10' High
Lighting, Sodium Vapor, GE, 10' High
Lighting, Outside, Mercury Vapor, Crouse-Hinds, 24' High, Double Lights
Lighting, Outside, Mercury Vapor, Art Metal, Recessed, 12' High
Lighting, Outside, Mercury Vapor, Art Metal, Recessed, 12' High
Lighting, Outside, Mercury Vapor, Art Metal, Recessed, 12' High
Lighting, Sodium Vapor, GE, 10' High
Lighting, Sodium Vapor, GE, 10' High
Lighting, Sodium Vapor, GE, 10' High
Lighting, Sodium Vapor, GE, 10' High
Lighting, Outside, Mercury Vapor, Art Metal, Recessed, 12' High
Lighting, Outside, Mercury Vapor, Art Metal, Recessed, 12' High
Lighting, Outside, Mercury Vapor, Art Metal, Recessed, 12' High
GENERAL SERVICES ADMINISTRATION 21 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
L-04B 030 Outside
L-04B 031 Outside
L-04B 032 Outside
L-04B 033 Outside
L-04B 034 Outside
L-04B 035 Parking Lot
L-04B 036 Parking Lot
L-04B 037 Parking Lot
L-04B 038 Parking Lot
L-04B 039 Parking Lot
L-04B 040 Parking Lot
L-04B 041 Parking Lot
L-04B 042 Parking Lot
L-04B 043 Parking Lot
L-04B 044 Parking Lot
L-04B 045 Parking Lot
L-04B 046 Parking Lot
L-04B 047 Parking Lot
L-04B 048 Parking Lot
L-04B 049 Parking Lot
L-04B 050 Parking Lot
L-04B 051 Parking Lot
L-04B 052 Parking Lot
L-04B 053 Parking Lot
L-04B 054 Parking Lot
Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 39' High, 1 Light Per Pole
Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 12' High
Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 12' High
Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 12' High
Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 12' High
Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 39' High, 1 Light Per Pole
Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 12' High
Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 12' High
Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 12' High
Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 12' High
Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 39' High, 1 Light Per Pole Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 39' High, 1 Light Per Pole Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 39' High, 1 Light Per Pole Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 39' High, 1 Light Per Pole
Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 39' High, 1 Light Per Pole
Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 39' High, 1 Light Per Pole
Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 39' High, 1 Light Per Pole Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 39' High, 1 Light Per Pole Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 39' High, 1 Light Per Pole
Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 39' High, 1 Light Per Pole Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 39' High, 1 Light Per Pole Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 39' High, 1 Light Per Pole Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 39' High, 1 Light Per Pole Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 39' High, 1 Light Per Pole Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 39' High, 1 Light Per Pole
GENERAL SERVICES ADMINISTRATION 22 GSA FORM 1736 (REV. 6-80)
8PM-PS 10/19/2017 R Hagmann
PM
GUIDE
NUMBER
EQUIPMENT
NUMBER
LOCATION
Federal Building, Huron, SD SD0038ZZ
DESCRIPTION AND REMARKS
Air Dryer (refrigerant) Hankinson, 10 CFM
EQUIPMENT INVENTORY LIST
Note: SC = Service Call / AO-RWA= Agency Owned-RWA required before repair can be performed
L-04B 055 Parking Lot
L-04B 056 Parking Lot
L-04B 057 Outside
L-05 001 Exterior
M-02 001 Exterior
M-03 001 Garage
M-03 002 135
M-03 003 Garage
M-03 004 502
M-03 005 502
M-03 006 502
M-03 007 502
M-03 008 502
M-03 009 502
M-03 010 Roof
M-03 011 Roof
M-03 012 502
M-03 013 502
M-03 014 503
M-03 015 503
M-03 016 503
M-03 017 503
M-03 018 503
M-03 019 503
M-03 020 502
Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 39' High, 1 Light Per Pole Lighting, Outside, Sodium, Vapor, Crouse-Hinds, 39' High, 1 Light Per Pole
Motor, 3 HP, Cooling Coil Pump, AHU #2
Motor, 5 HP (Condenser Cooling Water)
Motor, 5 HP (Condenser Cooling Water)
Motor, Century, 1 HP (Air Comp.)
Motor, 5 HP, Heating Water Pump #2, Secondary
Motor, 15 HP (Return Fan #1)
Motor, 2 HP, Heating Water Pump #3, Primary
Motor, 2 HP, Heating Water Pump #4, Primary
Motor, GE, 2 HP (Air Comp.)
Motor, 3 HP, Cooling Coil Pump, AHU #1
Motor, 2 HP, Heating Water Pump #6, Preheat coils
Motor, 7.5 HP (Cooling Tower #2 Fan)
Motor, 7.5 HP (Chilled Water)
Motor, 7.5 HP (Chilled Water)
Motor, 5 HP, Heating Water Pump #1, Secondary
Motor, 7.5 HP (Cooling Tower #1 Fan)
Lighting, Outside, Quartz, Crouse-Hinds, 16' High, Flagpole Light
With Adjustable Beam and Electric Eye, Leach
Motor,…