Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE

2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)

7. ADMINISTERED BY (If other than Item 6) CODE

STANDARD FORM 30 (REV. 11/2016)

Prescribed by GSA FAR (48 CFR) 53.243

FACILITY CODE

9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED (SEE ITEM 13)

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.

12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER

NUMBER IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15C. DATE SIGNED

15A. NAME AND TITLE OF SIGNER (Type or print)

16C. DATE SIGNED

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

PAGE OF PAGES

6. ISSUED BY CODE

8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X)

CODE

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

Previous edition unusable x

X

5P2QCB

Aneesah Muhammad, Contracting Officer

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

Amendment 0002 to RFP 47PF0023R0022 for Transaction Windows for US Bankruptcy Court and US District Court, located at the Hammond U.S. Courthouse, 5400 Federal Plaza, Hammond, IN 46320, is being issued to provide a revised section to the specification and to extend the Proposal Due Date from April 7, 2023, to April 14, 2023.

Continue on next page

General Services Administration 230 S. Dearborn, Room 3500 Chicago, IL. 60604

General Services Administration 230 S. Dearborn, Room 3500 Chicago, IL. 60604

RFP 47PF0023R0022

1 1

03/31/2023

02/17/2023

USDC & USBC Transaction Windows PBS-REG-5 Hammond, Indiana 47PF0020F0874

TABLE OF CONTENTS

SENSITIVE BUT UNCLASSIFIED (SBU)

PROPERTY OF THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice

Properly destroy document when no longer needed

DIVISION

SECTION

TITLE

PAGES

THRU

01 GENERAL REQUIREMENTS

01 10 00 Summary 1 – 3 01 14 00 Work Restrictions 1 – 3 01 25 00 Substitution Procedures 1 – 4 01 29 00 Payment Procedures 1 – 3 01 31 00 Project Management and Coordination 1 – 8 01 31 20 Critical Path Method 1 – 7 01 32 00 Construction Progress Documentation 1 – 2 01 33 00 Submittal Procedures 1 – 7 01 35 25 Fire Prevention and Protection in Construction and Demo-lition Procedures 1 – 7

01 35 26 Safety and Health 1 – 8 01 40 00 Quality Assurance 1 – 6 01 42 00 References 1 – 10 01 59 30 Security Regulations 1 – 3 01 60 00 Product Requirements 1 – 4 01 70 00 User Execution Requirements 1 – 4 01 73 10 Cutting and Patching 1 – 4 01 73 20 Selective Demolition 1 – 8 01 73 50 Fire Prevention Precautions for Hot Work 1 – 3 01 74 19 Construction Nonhazardous Waste Management and

Disposal 1 – 6

01 78 10 Project Record Documents 1 – 3 01 78 22 Operation and Maintenance Documentation 1 – 8

06 WOOD

06 10 00 Rough Carpentry 1 – 4 06 40 23 Interior Architectural Woodwork 1 – 7

07 THERMAL AND MOISTURE PROTECTION

07 84 13 Penetration Firestopping 1 – 3 07 92 00 Joint Sealants 1 – 5

08 OPENINGS

08 71 00 Door Hardware 1 – 9 08 88 53 Security Glazing 1 - 8

Hammond, Indiana 47PF0020F0874

SENSITIVE BUT UNCLASSIFIED (SBU)

PROPERTY OF THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice

Properly destroy document when no longer needed

DIVISION

SECTION

TITLE

PAGES

THRU

09 FINISHES

09 22 16 Non-Structural Metal Framing 1 – 7 09 29 00 Gypsum Board 1 – 4 09 91 23 Interior Painting 1 – 5

10 SPECIALTIES

10 14 23 Panel Signage 1 – 3

12 FURNISHINGS

12 36 23.13 Plastic-Laminate-Clad Countertops 1 – 6

13 SPECIAL CONSTRUCTION

13 47 15 Bullet Resistant Products (Transaction windows, doors and frames) 1 – 6

26 ELECTRICAL

26 05 19 Low-Voltage Electrical Power Conductors and Cables 1 – 4 26 05 26 Grounding and Bonding for Electrical Systems 1 – 4 26 05 29 Hangers and supports for Electrical Systems 1 – 5 26 05 33 Raceways and Boxes for Electrical Systems 1 – 3 26 05 44 Sleeves and Sleeve Seals for Electrical Raceways 1 – 4 26 05 53 Identification for Electrical Systems 1 – 7 26 27 26 Wiring Devices 1 – 6

27 COMMUNICATIONS

27 05 28 Pathways for Communications Systems 1 – 3 27 05 44 Sleeves and Sleeve Seals for Communications 1 – 5 27 05 53 Identification for Communications Systems 1 – 7

28 ELECTRONIC SAFETY AND SECURITY

28 05 28 Pathways for Electronic Safety and Security 1 – 8 28 05 44 Sleeves and Sleeve Seals for Electronic Safety 1 – 5 28 31 01 Voice Evacuation Fire Alarm Systems 1 – 31

APPENDIX

Appendix A Building Specific COVID Information 1 – 2

END OF TABLE OF CONTENTS

Hammond - Indiana 47PF0020F0874

SECURITY GLAZING 08 88 53

SENSITIVE BUT UNCLASSIFIED (SBU)

PROPERTY OF THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice

Properly destroy document when no longer needed

SECTION 08 88 53 - SECURITY GLAZING

PART 1 - GENERAL

1.1 SUMMARY

A. Section includes:

1. Security glazing

2. Glazing sealants and accessories

3. Accessories including channel framing, speakers and dealer trays.

1.2 RELATED SECTIONS

A. Section 06 10 00 - Rough Carpentry.

B. Section 06 40 23 – Interior Architectural Woodwork

C. Section 09 22 16 – Non-Structural Metal Framing

D. Section 09 91 23 – Interior Painting.

1.3 REFERENCE STANDARDS

A. ASTM International (ASTM)

1. ASTM F1233: Standard Test Method for Security Glazing Materials and Systems.

B. H.P. White (HPW)

1. HPW-TP-0500.03 – Transparent Materials for Use in Forced Entry or Containment Barriers.

C. Underwriters Laboratories LLC (UL):

1. UL 972 – Standard for Burglary Resisting Glazing Material.

1.4 COORDINATION

A. Coordinate glazing channel dimensions to provide necessary bite on security glazing, minimum edge and face clearances, and adequate sealant thicknesses, with reasonable tolerances.

SECURITY GLAZING 08 88 53

SENSITIVE BUT UNCLASSIFIED (SBU)

PROPERTY OF THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice

Properly destroy document when no longer needed

1.5 PREINSTALLATION MEETINGS

A. Preinstallation Conference: Conduct conference at Project site.

1.6 ACTION SUBMITTALS

A. Submit under provisions of Section 01 33 00 – Submittal Procedures.

B. Product data: For each type of product.

B. Samples for Verification:

1. Security Glazing Samples: 12”x12” sample of finished products for each type of security glazing

2. Glazing Accessory Samples: Manufacturer's standard color, showing full range of available colors for each type of sealant. Install samples between two strips of material representative in color of the adjoining framing.

C. Security Glazing Schedule: List security glazing types and thicknesses for each size opening and location.

Use same designations indicated on Drawings. Indicate coordinated dimensions of security glazing and construction that receives security glazing, including clearances and glazing channel dimensions.

1.7 INFORMATIONAL SUBMITTALS

A. Test and Evaluation Reports:

1. Product test reports.

2. Preconstruction test reports.

B. Sample warranties. For special warranties.

1.8 QUALITY ASSURANCE

A. Qualifications:

1. Installers: Entity that employs installers and supervisors who are trained and approved by manufacturer.

2. Supplier of products and an employer of workers trained and approved by product manufacturers who is available during the course of the Work to consult Contractor, Architect, and Government.

SECURITY GLAZING 08 88 53

SENSITIVE BUT UNCLASSIFIED (SBU)

PROPERTY OF THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice

Properly destroy document when no longer needed

1.9 WARRANTY

A. Special Warranty: Manufacturer agrees to replace security glazing that fails in materials or workmanship within specified warranty period.

1. Warranty Period: Five years from date of Substantial Completion.

2.PRODUCTS

2.1 GLAZING MANUFACTURERS

A. Acceptable Manufacturers:

1. McGrory Glass, DefendED

2. Riot Glass, ArmorPlast

3. Vetrotech Saint-Gobain, VDS Attack Resistant

4. Or Government-approved equal.

2.2 PERFORMANCE REQUIREMENTS

A. Safety Glazing: Where safety glazing is indicated, provide glazing that complies with 16 CFR 1201, Category II.

1. NGA Publications: "Laminated Glazing Reference Manual" and "GANA Glazing Manual."

2.3 SECURITY GLAZING, GENERAL

A. Glazing Publications: Comply with published recommendations of security glazing and glazing material manufacturers and organizations below unless more stringent requirements are indicated. Refer to these publications for glazing terms not otherwise defined in this Section or in referenced standards.

B. Plastic Glazing Labeling: Identify plastic sheets with appropriate markings of applicable testing and inspecting agency, indicating compliance with required fire-test-response characteristics.

C. Safety Glazing Labeling: Where safety glazing is indicated, permanently mark glazing with certification label of the Safety Glazing Certification Council or another certification agency acceptable to authorities having jurisdiction. Label will indicate manufacturer's name, type of glazing, glass thickness, and safety glazing standard with which glazing complies.

SECURITY GLAZING 08 88 53

SENSITIVE BUT UNCLASSIFIED (SBU)

PROPERTY OF THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice

Properly destroy document when no longer needed

2.4 GLASS PRODUCTS

A. Float Glass: ASTM C1036, Type I, Quality-Q3, Class I (clear) unless otherwise indicated.

B. Heat-Treated Float Glass: ASTM C1048; Type I; Quality-Q3; Class I (clear) unless otherwise indicated; of kind and condition indicated.

2.5 LAMINATED-GLASS SECURITY GLAZING

A. Laminated-Glass Security Glazing: ASTM C1172. Two or more glass lites bonded with interlayer. Use materials that have a proven record of no tendency to bubble, discolor, or lose physical and mechanical properties after fabrication and installation.

1. Interlayer Thickness: Provide thickness not less than that indicated and as needed to comply with requirements.

2. Interlayer Color: Clear unless otherwise indicated.

2.6 POLYCARBONATE SECURITY GLAZING

A. Monolithic Polycarbonate Security Glazing: ASTM C1349, Appendix X1, Type II, coated, mar-resistant, UV-stabilized polycarbonate with coating on exposed surfaces and Type I, standard, UV-stabilized polycarbonate where no surfaces are exposed.

2.7 GLAZING SEALANTS

A. General:

1. Compatibility: Provide glazing sealants that are compatible with one another and with other materials they contact, including security glazing, seals of insulating security glazing and air-gap security glazing, and glazing channel substrates, under conditions of service and application, as demonstrated by sealant manufacturer based on testing and field experience.

2. Suitability: Comply with sealant and security glazing manufacturers' written instructions for selecting glazing sealants suitable for applications indicated and for conditions existing at time of installation.

3. Colors of Exposed Glazing Sealants: As selected by Architect from manufacturer's full range of Industry colors.

B. Security Sealant: Manufacturer's standard, nonsag, tamper-resistant sealant for joints with low movement complying with ASTM C920, Grade NS, Class 12.5 or 25, Use NT, and with a Shore A hardness of at least 45 when tested in accordance with ASTM C661.

SECURITY GLAZING 08 88 53

SENSITIVE BUT UNCLASSIFIED (SBU)

PROPERTY OF THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice

Properly destroy document when no longer needed

2.8 GLAZING TAPES

A. Back-Bedding Mastic Glazing Tapes: Preformed, butyl-based, 100 percent solids elastomeric tape;

nonstaining and nonmigrating in contact with nonporous surfaces; with or without spacer rod as recommended in writing by tape and security glazing manufacturers for application indicated; and complying with ASTM C1281 and AAMA 800 for products indicated below:

1. AAMA 806.3 tape, for glazing applications in which tape is subject to continuous pressure.

2. AAMA 807.3 tape, for glazing applications in which tape is not subject to continuous pressure.

B. Expanded Cellular Glazing Tapes: Closed-cell, PVC foam tapes; factory coated with adhesive on both surfaces; and complying with AAMA 800 for the following types:

1. AAMA 810.1, Type 1, for glazing applications in which tape acts as the primary sealant.

2. AAMA 810.1, Type 2, for glazing applications in which tape is used in combination with a full bead of liquid sealant.

2.9 MISCELLANEOUS GLAZING MATERIALS

A. Cleaners, Primers, and Sealers: Types recommended by sealant or gasket manufacturer.

B. Setting Blocks:

1. EPDM or Silicone with Shore A durometer hardness of 85, plus or minus 5.

2. Type recommended in writing by sealant or glass manufacturer.

C. Edge Blocks:

1. EPDM or Silicone with Shore A durometer hardness in accordance with manufacturer's written instructions.

2. Type recommended in writing by sealant or glass manufacturer.

D. Cylindrical Glazing Sealant Backing: ASTM C1330, Type O (open-cell material), of size and density to control glazing sealant depth and otherwise produce optimum glazing sealant performance.

2.10 FABRICATION OF SECURITY GLAZING

A. Fabricate security glazing in sizes required to fit openings indicated for Project, with edge and face clearances, edge and surface conditions, and bite complying with written instructions of product manufacturer and referenced glazing publications, to comply with system performance requirements.

SECURITY GLAZING 08 88 53

SENSITIVE BUT UNCLASSIFIED (SBU)

PROPERTY OF THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice

Properly destroy document when no longer needed

2.11 ACCESSORIES

A. Aluminum Channel Frame

1. Acceptable Manufacturer:

a. Basis of Design: Total Security Systems, Non-Rated Aluminum U Channel

b. Or Government-approved equal.

2. Finish: Custom paint.

3. Exposed Fasteners: None.

B. Speaking Portal

1. Acceptable Manufacturer:

a. Basis of Design: Total Security Systems, Model #NVRTW with speaker hole and backer.

b. Or Government-approved equal.

2. Overall Size and Configuration: As indicated on Drawings.

C. Document Tray

1. Acceptable Manufacturer:

a. Basis of Design: Total Security Systems, Model # TSSDT1610

b. Or Government-approved equal.

2. Size: 16 by 10 inches from the outside edge of flanges with a clear open depth under the glazing no less than 1-1/2 inches.

3. Material: Stainless steel with a No. 4 finish.

3.EXECUTION

3.1 GLAZING, GENERAL

A. Comply with combined written instructions of manufacturers of security glazing, sealants, gaskets, and other glazing materials unless more stringent requirements are indicated, including those in referenced glazing publications.

B. Protect edges of security glazing from damage during handling and installation. Remove damaged security glazing from Project site and legally dispose of it off Project site. Damaged security glazing includes units with edge or face damage or other imperfections that, when installed, could weaken security glazing and impair performance and appearance.

C. Apply primers to joint surfaces where required for adhesion of sealants, as determined by preconstruction testing.

SECURITY GLAZING 08 88 53

SENSITIVE BUT UNCLASSIFIED (SBU)

PROPERTY OF THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice

Properly destroy document when no longer needed

D. Install setting blocks in sill rabbets, sized and located to comply with referenced glazing publications unless otherwise required by glazing unit manufacturer. Set blocks in thin course of compatible sealant suitable for heel bead.

E. Do not exceed edge pressures stipulated by security glazing manufacturers for installing lites.

F. Provide spacers for security glazing lites where the length plus width is larger than 50 inches (1270 mm).

G. Provide edge blocking where indicated or needed to prevent security glazing from moving sideways in glazing channel, as recommended in writing by security glazing manufacturer and in accordance with requirements in referenced glazing publications.

3.2 TAPE GLAZING

A. Position tapes on fixed stops so that, when compressed by security glazing, their exposed edges are flush with or protrude slightly above sightline of stops.

B. Install tapes continuously, but not necessarily in one continuous length. Do not stretch tapes to make them fit opening.

C. Cover vertical framing joints by applying tapes to heads and sills first and then to jambs. Cover horizontal framing joints by applying tapes to jambs and then to heads and sills.

D. Place joints in tapes at corners of opening with adjoining lengths butted together, not lapped. Seal joints in tapes with compatible sealant approved by tape manufacturer.

E. Do not remove release paper from tape until just before each glazing unit is installed.

F. Apply heel bead of elastomeric sealant.

G. Center security glazing in openings on setting blocks and press firmly against tape by inserting dense compression gaskets formed and installed to lock in place against faces of removable stops. Start gasket applications at corners and work toward centers of openings.

3.3 GASKET GLAZING (DRY)

A. Cut compression gaskets to lengths recommended in writing by gasket manufacturer to fit openings exactly, with allowance for stretch during installation.

B. Insert soft compression gasket between glazing unit and frame or fixed stop, so it is securely in place with joints miter cut and bonded together at corners.

C. Installation with Drive-in Wedge Gaskets: Center security glazing in openings on setting blocks and press firmly against soft compression gasket by inserting dense compression gaskets formed and installed to

SECURITY GLAZING 08 88 53

SENSITIVE BUT UNCLASSIFIED (SBU)

PROPERTY OF THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice

Properly destroy document when no longer needed lock in place against faces of removable stops. Start gasket applications at corners and work toward centers of openings. Compress gaskets to produce a weathertight seal without developing bending stresses in security glazing. Seal gasket joints with sealant recommended in writing by gasket manufacturer.

D. Installation with Pressure-Glazing Stops: Center security glazing in openings on setting blocks and press firmly against soft compression gasket. Install dense compression gaskets and pressure-glazing stops, applying pressure uniformly to compression gaskets. Compress gaskets to produce a weathertight seal without developing bending stresses in security glazing. Seal gasket joints with sealant recommended in writing by gasket manufacturer.

E. Install gaskets so they protrude past face of glazing stops.

3.4 SEALANT GLAZING (WET)

A. Install continuous spacers, or spacers combined with cylindrical sealant backing, between security glazing and glazing stops to maintain face clearances and to prevent sealant from extruding into glazing channel and blocking weep systems. Secure spacers, or spacers and backings, in place and in position to control depth of installed sealant relative to edge clearance for optimum sealant performance.

B. Force sealants into glazing channels to eliminate voids and to ensure complete wetting or bond of sealant to security glazing and channel surfaces.

C. Tool exposed surfaces of sealants to provide a substantial wash away from security glazing.

3.5 CLEANING AND PROTECTION

A. Immediately after installation remove nonpermanent labels and clean surfaces.

B. Protect security glazing from contact with contaminating substances resulting from construction operations, including weld splatter.

1. If, despite such protection, contaminating substances do contact with security glazing, remove substances immediately as recommended in writing by security glazing manufacturer. Remove and replace security glazing that cannot be cleaned without damage.

3.6 SECURITY GLAZING SCHEDULE

A. Security Glazing: Clear glass.

1. Forced-Entry Resistance, ASTM F1233: Class 1.4 in accordance with ASTM F1233.

2. Forced-Entry Resistance, HPW-TP-0500.03 in accordance with HPW-TP-0500.03.

3. Provide safety glazing labeling.

SECURITY GLAZING 08 88 53

SENSITIVE BUT UNCLASSIFIED (SBU)

PROPERTY OF THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice

Properly destroy document when no longer needed

END OF SECTION 08 88 53