472_25278.RWG Ionia IT Room Expansion - Addendum 2 - Combined.pdf
PDF 7 MB Posted
- Attached to
- 472/25278. RWG; Ionia C.F. - IT Room Expansion
- Solicitation number
- RFQ 171 270000000032 3
- Issued by
- Huron County, Michigan
About this file
This is a Construction Bid Addendum No. 2 issued by the Michigan Department of Technology, Management and Budget (DTMB), State Facilities Administration Design and Construction Division for the IT Room Expansion project at the Ionia Correctional Facility. The project involves expanding the information technology infrastructure and facilities at the correctional facility's administrative building on its second floor. The addendum was issued on November 12, 2026, with a bid opening date of November 18, 2026. The document serves to clarify and modify the original bidding documents through responses to contractor questions, updated drawings (A100 and E-500), and reissued pre-bid meeting materials. The project scope includes installation of new electrical panels (UPS-B and RP-D), transformers (45KVA and 30KVA), a 40KVA UPS system, new sealed concrete flooring, resinous flooring in specific rooms, new 1.5-hour fire-rated metal doors with dry suppression seals, removal and replacement of CMU walls, and HVAC modifications including roof penetrations with new roof pipe boots. Contractors are required to acknowledge this addendum in their bid submissions under penalty of bid rejection.
The addendum clarifies multiple technical and operational matters for bidders, including provisions for securing tools onsite in a job box located in the Administration Building with daily inventory checklists, worker escort procedures that allow for separation when not in extended work periods, leave for lunch with same-day return capability, and planned work hours of 4 ten-hour days starting at 6:30 AM through 4:30 or 5:00 PM. Electrical-only bids must be submitted to a prime contractor rather than directly in SIGMA. The document specifies that a fire damper is not required, a panic device on doors is not required by code, and roof penetrations are required with coordination responsibilities assigned to the contractor. Quality Roofing Inc. is identified as the roofing company contact, with the existing roof being a Carlisle Membrane System. The Byrd Anti-Lobbying Certificate is not required for this project. Specific rooms designated for sealed concrete flooring include CORR.1-208, TELEPHONE/DATA 1-210, and SERVER ROOM 1-211.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DTMB-0414 (Rev 12/17)
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET
State Facilities Administration Design and Construction Division
CONSTRUCTION BID ADDENDUM NO. 2
This form identifies an Addendum to Bidding Documents, and incorporates interpretations or clarifications, modifications, acceptance of proposed “or equal” materials, and other information into the Bidding Documents. Addenda will be numbered by the Professional and distributed through www.michigan.gov/SIGMAVSS as an attachment.
TO:
ALL BIDDERS
DATE ISSUED
11/12/2026
PROJECT NAME
IT Room Expansion - Ionia Correctional Facility
FILE NUMBER
472/25278.RWG
PROFESSIONAL
Commtech Design, Inc.
PROJECT DIRECTOR
Rob Gruesbeck
BID OPENING DATE:
11/18/2026
ADDENDUM ITEMS: (attach additional sheets and drawings if required)
Attachments;
1. Pre-Bid Sign in
2. Photos distributed at Pre-Bid Meeting.
Drawings reissued:
1. A100
a. Update room name to say ‘Corridor 1-220’. Update floor from ‘Concrete’ to ‘Sealed Concrete’.
2. E-500
a. Updated panel name.
Questions:
1. Can tools and materials stay securely onsite overnight, or does everything need to be brought in and out each day? What daily tool inventory is required?
Answer. You will be able to use a secured job box in the Administration Building for tools to keep them on site and have a daily checklist to make sure they are accounted for. If tools were needed to stay inside the secure area of the facility, it would be different process where we seek approval through the Inspector, have a job box and complete a tool inventory for all tools. I do recommend that maintenance have a key for the job box in case of emergencies.
2. If we have two workers onsite and one needs to go to the truck, can the other stay in the work area, or does the escort need to keep both workers together?
Answer. Yes, you should be able to send a worker to the truck and keep one working based on the location of the work as long as it not for an extended period.
3. Can we leave for lunch and return the same day? Is there a designated area where we can eat onsite instead?
Answer. Yes, you can leave for lunch and return the same day. There is not a designated area to eat onsite, you could potentially eat in the maintenance area if desired.
4. What are the contractor work hours, and how much time should we typically allow for check-in, tool inventory, and being escorted in and out??
Answer. The project is planned for 4-10 hour workdays. I would plan to start at 6:30AM and work until 4:30 or 5PM. The location of the project allows for easy access and a short time for getting in and out.
5. Can we submit an electrical-only bid directly in SIGMA, or should we send our electrical quote to a prime bidder?
Answer. No, you will need to send electrical only bids to a prime contractor.
http://www.michigan.gov/SIGMAVSS
6. On E-500 drawing: Does Ex panel “UPS” need to be connected to the new 40KVA UPS?
Answer. Ex panel “UPS” had all required UPS load separated from it as part of a different project.
Panel is not relabeled accordingly to LP-XB. Refer to revised E-500 for updated naming.
7. On E-500 drawing: What breakers are required for panels new “RP-D”, new “UPS-B”, replaced “UPS-A”, and replaced “RP-A”?
Answer. Refer to panel schedules.
8. On E-500 drawing: Please indicate the location of the connection for the EX-site cabinet.
Answer. Refer to drawings for location of the perimeter control cabinet disconnect. The wiring to the site cabinets does not need to be modified. It is only the connection to the disconnect that needs to be reworked and extended to the new UPS.
9. Can the bid date be extended to ensure the most accurate and complete bid?
Answer. The bid due date will not be extended.
10. On E-300 drawing: Please confirm that panel RP-A is to be replaced.
Answer. RPA will not be replaced. Refer to revised E-500 for updated naming.
11. Sheet A100 you indicate in finish schedule a room called open office. What room number is that.
Answer. For the open office, it should be replaced to say Corridor 1-220.
12. Specs call for resinous floor- If this is required what room get it?
Answer. Notes to SEAL CONCRETE FLOOR indicate where to apply resinous flooring. These rooms are CORR.1-208, TELEPHONE/DATA 1-210, & SERVER ROOM 1-211.
Clarifications:
1. Could you please confirm if the Byrd Anti-Lobbying Certificate is required to be submitted with our proposal?
Answer. Not required.
2. At the Pre-Bid Meeting, it was mentioned there may be fire damper required. Please clarify if this is required.
Answer. The mechanical engineer and architect have reviewed the fire damper requirement and determined a fire damper is not required. The mechanical engineer also verified there is no need for a panic device on the doors per code.
3. Are there roof penetrations required?
Answer. Yes. Refer to General Mechanical Note 2. “Refrigerant piping roof penetrations are to be routed up to roof through an existing pipe curb with new roof pipe boot installed on the top of the existing curb. Seal new boot watertight. All roof patching is to match existing, seal watertight, and maintain any existing roof warranties.
4. Please provide Roofing Company Contact information. Please also provide clarification for the contractors responsibility to coordinate with the Roofing Company.
Answer. Quality Roofing Inc. 10800 Plaza Drive, Whitmore Lake, MI 48189. The roofing warranty information states that the roofing is a Carlisle Membrane System. Contractor to handle all coordination for the roof penetrations.
ACKNOWLEDGEMENT: This Addendum must be acknowledged by the Bidder in the space provided in the Bid Summary and Bid Form. Failing to acknowledge Addenda may be cause for the Bid to be rejected. Addenda will become part of the Contract Documents.
PROFESSIONAL: Bret Emerson DATE: 11/12/2026
APPROVED BY:
PROJECT DIRECTOR: Rob Gruesbeck DATE: 11/12/2026
Ionia Admin Comm Room Expansion PreBid meeting 11/5/26
Comm Room A1 Pic 1 of 3:
Comm Room A1 Pic 2 of 3
Comm Room A1 Pic 3 of 3:
Rack A1-1
Rack A1-2
Comm Room A2 Pic 1 of 2:
Comm Room A2 Pic 2 of 2:
Rack A2-1
Rack A2-2
Rack A2-3
Top half of the rack
Rack A2-3
Bottom half of the rack
PPD Wall Rack
Mechanical Room
Electrical Room 209
Storage Room 211 Pic 1 of 2
Storage Room 211 Pic 2 of 2
INSTALL NEW SPECIAL
SEALED DOOR
FOR DRY SUPPRESSION
EXISTING DUCT CHASE
EXISTING 1HR FIRE
RATED WALLS
DOOR TO BE REMOVED AND REPLACED WITH
NEW INSULATED 1 1/2" HR RATED METAL DOOR
AND SPECIAL SEALED FOR DRY SUPPRESSION
'-1
1 2
'-4
REMOVE VCT AND CLEAN
CONCRETE FLOOR SURFACE
REMOVE EXISTING 8"X8"X16"
CMU WALL, FULL HEIGHT
CLEAN EXCESS, ADD BLOCK
FILLER AND PAINT TO MATCH
EXISTING.
2'-7 1 2" ±
8"3'-6 1 2" 5'-3"
'-9
7 8
'-2
1-
1-209 1-210
1-218b
1-b
23'-6"±
20'-2"±
5'-4" 8" 8'-0" 8" 8'-10"
'-0
1'-5"
10"
'-1
1 2
2'-10"3'-0"2'-2"±3'-0"
3'-4"3 '-0
'-4
'-7
" V .I.
F
'-3
V
.I.
F
'-8
'-8
1 2
NEW 8"X8"X16" CMU BLOCK
NEW 1 1/2 HR RATED METAL DOOR
3'-0" X 7'-0"
3 12" X 3 12" X 5 16"
ANGLES BACK TO
BACK
REMOVE ACOUSTIC
LAYIN CEILING
PAINT METAL DECK TO
MATCH EXISTING IN
ELECTRIC ROOM
3'-6 7 16"
2'-10 1 2"8" 8"
EXISTING CMU
WALL
ELECTRICAL UNIT
EXISTING CONDUITS
FOAM AND SEALANT
AROUND CONDUITS
SAWCUT EXISTING DOOR
FRAME. INSTALL NEW DOOR
FRAME USING POST
INSTILLATION ANCHORS
INTO EXISTING CMU WALL
INSULATED 1 1/2" HR RATED METAL
DOOR
AND SPECIAL SEALED FOR DRY
SUPPRESSION
BACKER
ROD AND
SEALANT
TYP.
PARTIAL FLOOR PLAN
1/4" = 1' - 0"A100
A100
1 ADMIN BUILDING SECOND FLOOR PLAN
1/8" = 1' - 0"
SECTION
1/4" = 1' - 0"A100
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
L A
TC
H
, R A
, N C
A R
B , D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
C om m te ch
D es ig n
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
PLAN DETAILS
1 1/2" = 1' - 0"A100
S t r a u b
P e t t i t t M a n n
0 N
. C ro ok s R oa d, Su ite
Cl aw so n, Mi ch iga n 4
8 -
8 -
GROUT SOLID
NEW 1 1/2" HR RATED
METAL DOOR
NEW 1 HR RATED
8"X8"X16" CMU
WALL.
NEW 1 HR RATED
8"X8"X16" CMU
WALL.
INSTALL DOOR SEALS FOR
DRY SUPPRESSION
CORRIDOR 1-220
FLOOR: CARPET PATCH
BASE: MATCH EXISTING
WALLS: PAINT TO MATCH EXISTING
CEILING: NO WORK
SERVER ROOM 1-211
FLOOR: SEALED CONCRETE
BASE: NONE
WALLS: PAINT
CEILING: PAINT
DOORS: PAINT
ELECTRICAL ROOM
FLOOR: NO WORK
BASE: NONE
WALLS: PAINT TO MATCH EXISTING
CEILING: PAINT
DOORS: PAINT
FINISH SCHEDULE
WALL DETAIL AT CONDUITS
1 1/2" = 1' - 0"A100
PLAN DETAILS
1 1/2" = 1' - 0"A100
A100
GROUT SOLID
SEAL CONCRETE FLOOR
SEAL CONCRETE FLOOR
PORTION OF
EXISTING CMU WALL
TO REMAIN
8"X8"X16" CMU FINISH ON TWO
SIDES TOOTH INTO EXISTING
BLOCK PAINT TO MATCH
EXISTING
FOAM AND
SEALANT IN 2" ±
SPACE
8"X8"X16" CMU
FINISH ON TWO
SIDES
BACKER ROD AND
SEALANT TYP.
NOTE:
NEW DOORS HARDWARE SET 1:
Door Bottom: Zero 355AA Semi Mortised Automatic Door Bottom with Neoprene Seal.
Perimeter Gasketing: Zero 870AA Adjustable Perimeter Gasketing Acoustic Door Seal Set.
EXISTING CORRIDOR DOOR 1-209 HARDWARE SET 2:
Door Bottom: Zero 361AA Heavy-Duty Surface Mounted Automatic Door Bottom
Perimeter Gasketing: Zero 870AA Adjustable Perimeter Gasketing Acoustic Door Seal Set
AutoCAD SHX Text 1-218
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
ROOM
AutoCAD SHX Text 1-207
AutoCAD SHX Text
HUMAN
AutoCAD SHX Text
RESOURCES
AutoCAD SHX Text 1-205
AutoCAD SHX Text
HUMAN
AutoCAD SHX Text
RESOURCE
AutoCAD SHX Text
RECORDS ROOM
AutoCAD SHX Text 1-204
AutoCAD SHX Text
HUMAN
AutoCAD SHX Text
RESOURCES
AutoCAD SHX Text 1-203
AutoCAD SHX Text H.R.
AutoCAD SHX Text
SUPERVISOR
AutoCAD SHX Text 1-202
AutoCAD SHX Text
FACILITY
AutoCAD SHX Text
MANAGER
AutoCAD SHX Text
XXXX
AutoCAD SHX Text
ELEV.
AutoCAD SHX Text 1-201
AutoCAD SHX Text
FACILITY
AutoCAD SHX Text
MANAGER
AutoCAD SHX Text
SECRETARY
AutoCAD SHX Text 1-A
AutoCAD SHX Text
STAIR
AutoCAD SHX Text 1-B
AutoCAD SHX Text
STAIR
AutoCAD SHX Text 1-216
AutoCAD SHX Text
MEN
AutoCAD SHX Text 1-215
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text 1-213
AutoCAD SHX Text J.C.
AutoCAD SHX Text 1-212
AutoCAD SHX Text
LOUNGE
AutoCAD SHX Text 1-211
AutoCAD SHX Text
SERVER ROOM
AutoCAD SHX Text 1-209
AutoCAD SHX Text
ELECT.
AutoCAD SHX Text
ROOM
AutoCAD SHX Text 1-208
AutoCAD SHX Text
CORR.
AutoCAD SHX Text 1-217
AutoCAD SHX Text
EMPLOYEE
AutoCAD SHX Text
COMP
AutoCAD SHX Text
TRAINING AREA
AutoCAD SHX Text 1-218
AutoCAD SHX Text
AutoCAD SHX Text
ROOM
AutoCAD SHX Text 1-221
AutoCAD SHX Text
STAFF
AutoCAD SHX Text
TRAINING
AutoCAD SHX Text
AREA
AutoCAD SHX Text 1-222
AutoCAD SHX Text
HRD
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text 1-223
AutoCAD SHX Text
HRD
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 1-206
AutoCAD SHX Text
CORR.
AutoCAD SHX Text 1-219
AutoCAD SHX Text
CORR.
AutoCAD SHX Text 1-220
AutoCAD SHX Text
CORR.
AutoCAD SHX Text 1-214
AutoCAD SHX Text
CORR.
AutoCAD SHX Text
DROP CEILING
AutoCAD SHX Text
DROP CEILING
AutoCAD SHX Text
DROP CEILING
AutoCAD SHX Text
DROP CEILING
AutoCAD SHX Text
DROP CEILING
AutoCAD SHX Text
DROP CEILING
AutoCAD SHX Text
DROP CEILING
AutoCAD SHX Text
DROP CEILING
AutoCAD SHX Text
DROP CEILING
AutoCAD SHX Text
DROP CEILING
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A100
AutoCAD SHX Text
AutoCAD SHX Text 1-210
AutoCAD SHX Text
TELEPHONE/DATA
AutoCAD SHX Text A100
AutoCAD SHX Text
AutoCAD SHX Text A100
AutoCAD SHX Text
AutoCAD SHX Text A101
AutoCAD SHX Text
AutoCAD SHX Text A101
AutoCAD SHX Text
AutoCAD SHX Text 1-211
AutoCAD SHX Text
SERVER ROOM
AutoCAD SHX Text 1-209
AutoCAD SHX Text
ELECT.
AutoCAD SHX Text
ROOM
AutoCAD SHX Text 1-208
AutoCAD SHX Text
CORR.
AutoCAD SHX Text 1-210
AutoCAD SHX Text
TELEPHONE/DATA
AutoCAD SHX Text A100
AutoCAD SHX Text
AutoCAD SHX Text A100
AutoCAD SHX Text
AutoCAD SHX Text A100
AutoCAD SHX Text
AutoCAD SHX Text 1-209b
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text index no.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text sheet title
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
IONIA IT ROOM EXPANSION
AutoCAD SHX Text
IONIA CORRECTIONAL FACILITY
AutoCAD SHX Text
IONIA, MICHIGAN
AutoCAD SHX Text 472ElectronicComm
AutoCAD SHX Text 1065_43
AutoCAD SHX Text Y17084
AutoCAD SHX Text
472/25278.RWG
AutoCAD SHX Text
DOOR SCHEDULE
AutoCAD SHX Text
DOOR NUMBERS
AutoCAD SHX Text
DOOR SIZE
AutoCAD SHX Text
DOOR TYPE
AutoCAD SHX Text
DOOR MAT'L
AutoCAD SHX Text
FRAME TYPE
AutoCAD SHX Text
FRAME MAT'L
AutoCAD SHX Text
FRAME DETAILS
AutoCAD SHX Text
HARDWARE SET
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
SET 1
AutoCAD SHX Text 1-211
AutoCAD SHX Text 3'-0" x 7'-0"
AutoCAD SHX Text
EXISTING TO REMAIN
AutoCAD SHX Text
EXISTING HOLLOW METAL
AutoCAD SHX Text
SET 2
AutoCAD SHX Text 3'-0" x 6'-10"
AutoCAD SHX Text
EXISTING HOLLOW METAL
AutoCAD SHX Text
SET 1
AutoCAD SHX Text
NEW HOLLOW METAL
AutoCAD SHX Text 1-209
AutoCAD SHX Text 1-210
AutoCAD SHX Text
INSULATED 1 1/2" HR RATED METAL DOOR PAINT DOOR AND FRAME
AutoCAD SHX Text
INSULATED 1 1/2" HR RATED METAL DOOR WITH DRY SUPPRESSION PAINT DOOR AND FRAME
AutoCAD SHX Text 3'-0" x 6'-10"
AutoCAD SHX Text 3'-0" x 6'-10"
AutoCAD SHX Text
PAINT DOOR AND FRAME
AutoCAD SHX Text
PAINT DOOR AND FRAME
AutoCAD SHX Text
NEW HOLLOW METAL
AutoCAD SHX Text
EXISTING HOLLOW METAL
AutoCAD SHX Text
EXISTING HOLLOW METAL
AutoCAD SHX Text
NEW HOLLOW METAL
AutoCAD SHX Text
NEW HOLLOW METAL
AutoCAD SHX Text
EXISTING TO REMAIN
AutoCAD SHX Text 10/19/26
AutoCAD SHX Text
ISSUED FOR BIDS
AutoCAD SHX Text 11/12/26
AutoCAD SHX Text ADDENDUM No.2
REPLACED PANEL "UPS-A"
120/208V-3Ø, 100A
T
NEW 45KVA XFMR
EX PANEL "MPB"
480V-3Ø, 600A
EX PANEL "LP-XB"
480V-3Ø, 30A
TEX
EX PANEL "L-RPX"
120/208V-3Ø, 100A
EX PANEL "RPX"
120/208V-3Ø, 100A
EX PANEL "LP-XA"
277V-3Ø, 100A
PANEL "RP-A"
120/208V-3Ø, 100A
EX PANEL "LP-ZA"
277V-3Ø, 100A
EX PANEL "LP-BB"
277V-3Ø, 100A
EX PANEL "EMPB"
480V-3Ø, 100A
RP-D-12,14,16
UPS-B-3,5,7
RP-A-45
RP-D-2
DR DR DR DR DR DR
NEW PANEL "UPS-B"
120/208V-3Ø, 200A
NEW 40KVA UPS
UPS-B-2
UPS-B-6UPS-B-1
UPS-B-4
RP-D-10
RP-D-8
RP-D-4
T
NEW 30KVA XFMR
NEW PANEL "RP-D"
120/208V-3Ø, 100A
AC-2
208V-1Ø, 2.2FLA
CU-2 (ON ROOF)
208V-1Ø, 18.5FLA
AC-3
208V-1Ø, 2.2FLA
CU-3 (ON ROOF)
208V-1Ø, 18.5FLA
RP-D-9,11
RP-D-1,3
RP-D-5,7
UPS-B-12
84" AFF
84" AFF
RP-D-6
EX PERIMETER CONTROL DISCONNECT
EX 16KVA UPS
EX 15KVA UPS
RELOCATED FIRE CONTROL
PANEL
WP
WP
WP
GFCI
RP-D-13
UPS-B-9
RP-D-13
ELECTRICAL KEY NOTES
PROVIDE AND INSTALL NEW LIEBERT 40KVA UPS IN LOCATION SHOWN. PROVIDE
AND INSTALL NEW 80A LOCKABLE BREAKER IN PANEL MPB. MATCH EXISTING
BREAKER MANUFACTURER, PROVIDE AND INSTALL ALL CONDUIT, WIRE, AND
HARDWARE AS REQUIRED. REFER TO UPS SPECIFICATION ON SHEET E-100.
REFER TO SHEET E-500 DETAIL A FOR PARTIAL ONE-LINE DIAGRAM.
PROVIDE AND INSTALL NEW 45KVA PQI E-RATED TRANSFORMER. MODEL
EY-60-045-480:208/120-150-K4-Z3. FEED FROM NEW 40KVA UPS.
PROVIDE AND INSTALL NEW 120/208V-3Ø 100A PANEL. PROVIDE AND INSTALL
BREAKERS TO MATCH EXISTING CIRCUITS. PROVIDE AND INSTALL NEW LINE
VOLTAGE SURGE PROTECTION DEVICE IN PANEL (RAYCAP
RSE-120-3Y-A-05-E-F-S).
PROVIDE AND INSTALL NEW 120/208V-3Ø 200A PANEL. PROVIDE AND INSTALL
NEW LINE VOLTAGE SURGE PROTECTION DEVICE IN PANEL (RAYCAP
RSE-120-3Y-A-05-E-F-S).
PROVIDE AND INSTALL 20A RED DUPLEX RECEPTACLE FROM EXISTING CIRCUIT.
MODIFY AND EXTEND EXISTING CONDUIT AND WIRE AS REQUIRED.
PROVIDE AND INSTALL NEW 20A BLUE DUPLEX RECEPTACLE FROM UPS POWER.
PROVIDE AND INSTALL ALL CONDUIT, WIRE, AND HARDWARE AS REQUIRED.
PROVIDE AND INSTALL 20A L5-20 RED TWISTLOCK RECEPTACLE FROM EXISTING
CIRCUIT. MOUNT BELOW DATA RACK CABLE LADDER. MODIFY AND EXTEND
EXISTING CONDUIT AND WIRE AS REQUIRED.
PROVIDE AND INSTALL 20A L5-20 RED TWISTLOCK RECEPTACLE. MOUNT BELOW
DATA RACK CABLE LADDER. PROVIDE AND INSTALL ALL CONDUIT, WIRE, AND
HARDWARE AS REQUIRED.
PROVIDE AND INSTALL 20A L5-20 BLUE TWISTLOCK RECEPTACLE FROM UPS
POWER. MOUNT BELOW DATA RACK CABLE LADDER. PROVIDE AND INSTALL ALL
CONDUIT, WIRE, AND HARDWARE AS REQUIRED.
PROVIDE AND INSTALL 30A RED L21-30 TWISTLOCK RECEPTACLE. MOUNT
BELOW DATA RACK CABLE LADDER. PROVIDE AND INSTALL ALL CONDUIT, WIRE,
AND HARDWARE AS REQUIRED.
PROVIDE AND INSTALL 30A BLUE L21-30 TWISTLOCK RECEPTACLE FROM UPS
POWER. MOUNT BELOW DATA RACK CABLE LADDER. PROVIDE AND INSTALL ALL
CONDUIT, WIRE, AND HARDWARE AS REQUIRED.
PROVIDE AND INSTALL NEW 30KVA TRANSFORMER. PROVIDE AND INSTALL NEW
60A LOCKABLE BREAKER IN PANEL MPB. MATCH EXISTING BREAKER
MANUFACTURER, PROVIDE AND INSTALL ALL CONDUIT, WIRE, AND HARDWARE
AS REQUIRED.
CONNECT EXISTING 30A DISCONNECT TO NEW 40KVA UPS. MODIFY AND EXTEND
EXISTING CONDUIT AND WIRE AS REQUIRED.
PROVIDE AND INSTALL 20A RED QUAD RECEPTACLE . MOUNT BELOW DATA
RACK CABLE LADDER. PROVIDE AND INSTALL ALL CONDUIT, WIRE, AND
HARDWARE AS REQUIRED.
1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES. INSTALLATION OF ALL NEW
OR REWORKED CONDUIT, FITTINGS, AND STRAPS SHALL FOLLOW SPECIFICATIONS
LISTED ON SHEET E-100. THIS INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE
REUSED.
GENERAL ELECTRICAL NOTES
NEW 40 KVA UPS ONE-LINE DIAGRAM
SCALE: N.T.S.
A E-500
PANEL
EXISTING
MPB
480/277 V
3Ø, 4W 600A
NEW 40KVA UPS
480/277V-3Ø
(4) #4 AWG
(1) #8 GND
(1) 1-1/4" CND
(3) #2 AWG
(1) #8 GND
(1) 1-1/4" CND
45 KVA XFMR
PRIMARY:
480V-3Ø,3W
SECONDARY: 208V-3Ø,4W
208 VOLTS
PANEL
REPLACED
UPS-A
120/208V 3Ø, 4W
100A MLO
PANEL
NEW
UPS-B
120/208V 3Ø, 4W
200A MCB
(4) #2 AWG
(1) #8 AWG GND
(1) 1-1/4" CND
480 VOLTS
480 VOLTS
4 3
(3) #6 AWG
(1) #8 GND
(1) 3/4" CND
30 KVA XFMR
PRIMARY:
480V-3Ø,3W
SECONDARY: 208V-3Ø,4W
480 VOLTS
(4) #2 AWG
(1) #8 GND
(1) 1-1/4" CND
208 VOLTS
PANEL
NEW
RP-D
120/208V 3Ø, 4W
100A MCB
EX SITE CABINET
CONNECTION
30A/3P
3PH 4W
NEMA 1
FUSED
30A FUSES
90A
(3) #8
(1) #8 GND
2" CND
30A
(4) #3/0 AWG
(1) #4 AWG GND
(1) 2" CND
E-500
JJD
JFS
N 2ND FLOOR PLAN - POWER
SCALE: 1/8" = 1'-0"
0 1 5 10 20 file no.
checked by drawn by consultant issue date index no.
contract order no.
consultant job no.
sheet title
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
L A
TC
H
, R A
, N C
A R
B , D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
C om m te ch
D es ig n
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
472ElectronicComm
1065_43
Y17084
472/25278.RWG
10/19/26 ISSUE FOR BID
11/05/26 ADDENDUM #1
11/12/26 ADDENDUM #2
| Sheets and Views |
| ICF_100 Admin - Addendum No.1-A100 |
File details come from the government source that posted it. Updated .