472-24052.JGH Statewide Perimeter Repair-Replacement - Saint Louis Correctional Facility - Bid Set.pdf

PDF 1 MB Posted

Attached to
472/24052. JGH; St. Louis CF - Perimeter Fence Repair/Replace
Solicitation number
RFQ-171-250000000555-2
Issued by
Gogebic County, Michigan

About this file

These documents are bid set construction drawings for the State of Michigan Department of Technology, Management and Budget's Statewide Perimeter Repair/Replacement project at the St. Louis Correctional Facility, located at 8585 North Croswell Road in St. Louis, Michigan. The project involves comprehensive fencing enhancements for the facility's perimeter security, including installing new anti-climb razor mesh panels, replacing existing gates with upgraded double gates and vertical spring locking mechanisms, installing new man gates, adding stainless steel bottom plates to fencing, and removing and replacing a 12'x12' section of damaged asphalt with concrete. The bid set is dated 07/18/2025 and was prepared by Matrix Consulting Engineers, Inc. from Lansing, Michigan.

The site plan and detailed drawings provide specific technical specifications for the fencing upgrades, including precise installation instructions for various fence components such as razor ribbon, detection cables, gate mechanisms, and mounting hardware. The project appears to focus on improving security infrastructure by eliminating potential breach points and upgrading existing perimeter security systems. The drawings include detailed scale drawings and installation notes for each proposed modification, indicating a comprehensive approach to facility security enhancement. The project documents suggest this is a targeted improvement to the correctional facility's existing security infrastructure, with careful attention to technical details and systematic replacement of aging or vulnerable fencing components.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BTT

JFS

file no.

checked by drawn by consultant issue date index no.

contract order no.

XXXXX

consultant job no.

24233.00 sheet title

M a t r ix

472/24052.JGH

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

BID SET 07/18/2025

T-000

1 11

11 1 1 1 11

1 4

7 5

FENCING KEY NOTES

1 INSTALL NEW ANTI-CLIMB RAZOR MESH PANEL ONTO FENCE PER DETAIL 1 ON

SHEET C-200.

REMOVE EXISTING COLUMN OF VERTICAL RAZOR RIBBON AND INSTALL NEW

ANTI-CLIMB RAZOR MESH PANEL TO FENCE PER DETAIL 1 ON SHEET C-200.

PROVIDE AND INSTALL NEW MAN GATE PER DETAIL 2 ON SHEET C-200.

PROVIDE AND INSTALL NEW STAINLESS STEEL PLATE TO BOTTOM OF FENCE

PER DETAIL 3 ON SHEET C-200.

REMOVE EXISTING DOUBLE GATES AND DROP ROD MECHANISM. PROVIDE AND

INSTALL NEW DOUBLE GATES & VERTICAL SPRING LOCKING MECHANISM PER

DETAILS 4, 6, 7 ON SHEET C-200.

REMOVE EXISTING DOUBLE GATES AND DROP ROD MECHANISM. PROVIDE AND

INSTALL NEW DOUBLE GATES & VERTICAL SPRING LOCKING MECHANISM PER

DETAILS 5, 6, 7 ON SHEET C-200.

REMOVE EXISTING SECTION (12'x12') OF DAMAGED ASPHALT AND REINSTALL NEW 12'x12' PAD OF CONCRETE.

BTT

JFS

SCALE: 1" = 80'-0"

200 10 40 80 160 200

N SITE PLAN - FENCING ENHANCEMENTS

file no.

checked by drawn by consultant issue date index no.

contract order no.

XXXXX

consultant job no.

24233.00 sheet title

M a t r ix

472/24052.JGH

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

C-100

EXISTING FENCE

FABRIC

EXISTING

DETECTION CABLE

PROVIDE AND INSTALL STAINLESS STEEL TIE WIRES.

TIES SHALL BE TWIST TO SECURE THE RAZOR MESH

TO FENCE. INSTALL AT 12" O.C. WITH 9 GAUGE AND NO

LESS THAN 5 COMPLETE TWISTS.

NOTES:

(3) EXISTING

ROWS OF DETAINER HOOK

RAZOR RIBBON

EXISTING

1.660" MID RAIL

RAZOR MESH 24"

WIDE MIN. ON SECURE

SIDE OF FENCE

EXISTING

TENSION BANDS

EXISTING

TENSION BARS

EXISTING

1.660" TOP RAIL

EXISTING 1.660"

BOTTOM RAIL

GROUND GROUND

FENCE FABRIC - ANTI-CLIMB RAZOR MESH PANEL

SCALE: N.T.S.1

NEW (4'x7') MAN GATE

7'

12'

EXISTING RAZOR

RIBBON (TYP.)

INSTALL NEW RAZOR

MESH PANEL

INSTALL NEW RAZOR

MESH PANEL

EXISTING FENCE

FABRIC (TYP.)

EXISTING 1.660"

TOP RAIL

EXISTING 1.660"

MID RAIL

EXISTING 1.660"

BOTTOM RAIL

NEW 4" TALL STAINLESS STEEL

PLATES AT BOTTOM OF GATE4'

2 NEW MAN GATE DETAIL - INSTALLATION

SCALE: N.T.S.

3 EXISTING MAN GATE DETAIL - NEW STEEL PLATE INSTALLATION

SCALE: N.T.S.

EXISTING MAN GATE

7'

12'

EXISTING RAZOR

RIBBON (TYP.)

EXISTING RAZOR

MESH PANEL

EXISTING RAZOR

MESH PANEL

EXISTING FENCE

FABRIC (TYP.)

EXISTING 1.660"

TOP RAIL

EXISTING 1.660"

MID RAIL

EXISTING 1.660"

BOTTOM RAIL

NEW 4" TALL STAINLESS STEEL

PLATES AT BOTTOM OF GATE

12' 16'

EXISTING 4" DIAMETER

FENCEPOST CAP (TYP.)

10'

NEW

TRANSOM

C-200

C-200

NEW 36" DETAINER HOOK

RAZOR RIBBON (TYP.)

EXISTING 1.660"

TOP RAIL

EXISTING 1.660"

MID RAIL

EXISTING 1.660"

BOTTOM RAIL

14'

NEW 4" DIA.

FENCEPOST (16')

NEW 4" DIA.

FENCEPOST (16')

NEW GATE

FABRIC

NEW TRANSOM

FENCE FABRIC

EXISTING FENCE

FABRIC (TYP.)

EXISTING DETAINER

HOOK RAZOR RIBBON

(TYP.)

4 NEW TRANSOM SPRING LOCK DETAIL - INSTALLATION

SCALE: N.T.S.

4" TALL STEEL

PLATE (TYP.)

NEW 10'x14' GATENEW 10'x14' GATE

10'

GAP NOT TO EXCEED 4"

GAP NOT TO

EXCEED 4"

6 NEW SPRING LOCK MECHANISM DETAIL - INSTALLATION

SCALE: N.T.S.

NEW SPRING

NEW SPRING RESTRAINT (BOTTOM)

NEW SPRING RESTRAINT (TOP)

NEW HANDLE TO COMPRESS

SPRING & RELEASE LOCKING

MECHANISM

NEW GUIDE FOR

VERTICAL LOCK ROD

NEW VERTICAL LOCK ROD

NEW GATE LATCH

NEW GATE LATCH

RECEIVER

GAP NOT TO

EXCEED 4"

4" TALL STEEL PLATE (TYP.)

7 NEW TRANSOM LOCK DETAIL - INSTALLATION

SCALE: N.T.S.

NEW 1.660" HORIZONTAL

TRANSOM RAIL (TYP.)

NEW 1.660" VERTICAL

TRANSOM RAIL

NEW GATE

NEW GUIDE FOR

VERTICAL LOCK ROD

NEW VERTICAL

LOCK ROD

NEW VERTICAL LOCK ROD

RECEIVER (MOUNTED SECURELY

TO FACE OF TRANSOM)

NEW GATE

NEW VERTICAL

LOCK ROD

GAP NOT TO

EXCEED 4"

GAP NOT TO EXCEED 4"

5 NEW SPRING LOCK DETAIL - INSTALLATION

SCALE: N.T.S.

12'

10' 10'

NEW

10'x8' GATE

NEW

10'x8' GATE

EXISTING 4" DIA.

FENCEPOST (16' TALL)

EXISTING 4" DIA.

FENCEPOST (16' TALL)

4" TALL STEEL

PLATE (TYP.)

EXISTING 1.660"

TOP RAIL

EXISTING1.660"

MID RAIL

EXISTING 1.660"

BOTTOM RAIL

EXISTING FENCE

FABRIC (TYP.

EXISTING GATE

FABRIC

EXISTING DETAINER HOOK

RAZOR RIBBON (TYP.)

NEW

TRANSOM

NEW TRANSOM

FENCE FABRIC

GAP NOT TO EXCEED 4"

GAP NOT TO

EXCEED 4"

C-200

C-200

NEW 36" DETAINER

HOOK RAZOR RIBBON

10'

C-200

BTT

JFS

file no.

checked by drawn by consultant issue date index no.

contract order no.

XXXXX

consultant job no.

24233.00 sheet title

M a t r ix

472/24052.JGH

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

STRAIGHT CORNER

T000-2423300-SLF-T-000
C100-2423300-SLF-30x42
C200-2423300-SLF-30x42

File details come from the government source that posted it. Updated .