472_17032_RWG_Lakeland CF -Wifi Cablng Infrastructure - Add 01 - Complete.pdf
PDF 4 MB Posted
- Solicitation number
- RFQ-171-250000000427-2
- Issued by
- Barry County, Michigan
About this file
This document is a Construction Bid Addendum No. 1 issued by the Michigan Department of Technology, Management and Budget (DTMB), Design and Construction Division, for the Lakeland Correctional Facility Wi-Fi Cabling Infrastructure project. The addendum, dated 6/12/2025, provides updates and clarifications for the bid scheduled to open on 6/18/2025. Key details include the provision of two escorts, working hours of 5 eight-hour days starting at 7:00 AM, and specific site access requirements such as day passes, sign-in procedures, and vehicle restrictions. The project involves Wi-Fi cabling infrastructure installation, with modifications to drawings including connectivity code changes, rack layout updates, and details on routing wireless access point (WAP) cables in the warehouse and power house buildings.
The addendum includes several critical clarifications for bidders, such as the requirement to include an Asbestos form with the bid, provide cable manufacturer warranty per specifications, and adhere to specific site protocols. Working conditions involve restricted access, with the sallyport open at 7 AM, contractors allowed to use a Gator with lockable doors and gas cap, and kitchen/dining work to be performed after 7 PM. Equipment storage is limited, with no overnight storage in secure areas, and a job site trailer is permitted. The electrical scope includes 20 AMP circuits, with an electrical allowance for potential scope changes. The professional for the project is Commtech Design, Inc., with Rob Gruesbeck as the project director.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DTMB-0414 (Rev 12/17)
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET
State Facilities Administration Design and Construction Division
CONSTRUCTION BID ADDENDUM NO. 1
This form identifies an Addendum to Bidding Documents, and incorporates interpretations or clarifications, modifications, acceptance of proposed “or equal” materials, and other information into the Bidding Documents. Addenda will be numbered by the Professional and distributed through www.michigan.gov/SIGMAVSS as an attachment.
TO:
ALL BIDDERS
DATE ISSUED
6/12/2025
PROJECT NAME
Lakeland Correctional Facility – Wi-Fi Cabling Infrastructure
FILE NUMBER
472/17032.RWG
PROFESSIONAL
Commtech Design, Inc.
PROJECT DIRECTOR
Rob Gruesbeck
BID OPENING DATE:
6/18/2025
ADDENDUM ITEMS: (attach additional sheets and drawings if required)
Attachments:
1. Pre-Bid Sign In sheet.
2. TC704, TC708, TC809A,TC 809B & TC810
Drawings reissued:
1. TC704 - Connectivity code ‘45’ added for cabling details.
2. TC708 - Rack layout added for comm room W2 in the warehouse building and modifications for rack layouts in comm room D2.
3. TC809A, TC809B, TC810 – Connectivity code change to the APs. Comm room added in the warehouse building
‘W2’. Details on how to route WAP cables in the warehouse and power house building.
Clarifications:
1. There will be (2) escorts provided.
2. Working hours are 5 - 8-hour days starting at 7:00AM.
3. 20 AMP circuits are to be included in this bid per Keyed Notes on the drawings and Electrical Details on TC705. The Electrical Allowance is for changes to the electrical scope of work.
4. Escort not required outside of secure area.
5. Day passes are required. No site badges.
6. After receiving Day Pass all crew members must sign in each day at Maintenance Dave Karney’s office
7. Sallyport is open 7am
8. Contractor can have a Gator to go through Sallyport. Gator must have lockable doors and lockable gas cap.
9. Walking through sallyport is ok
10. Job Box / Gang box may stored inside secure area. Coordinate with the site
11. Contractor may have a Jobsite trailer
12. Kitchen/Dining work to be performed after 7pm
13. No equipment can be stored in secure area overnight
14. Include Asbestos form with your bid
15. Contractor to provide cable MFG warranty per specifications
ACKNOWLEDGEMENT: This Addendum must be acknowledged by the Bidder in the space provided in the Bid Summary and Bid Form. Failing to acknowledge Addenda may be cause for the Bid to be rejected. Addenda will become part of the Contract Documents.
PROFESSIONAL: Bret Emerson, Commtech Design DATE: 6/12/2025
APPROVED BY:
PROJECT DIRECTOR: Rob Gruesbeck DATE: 6/12/2025 http://www.michigan.gov/SIGMAVSS
TC704
METAL PIPE THROUGH GYPSUM WALL
ASSEMBLY (2-HR.) -TYPICAL
TC704
METAL PIPE THROUGH CONCRETE OR
BLOCK WALL ASSEMBLY (2-HR.) -TYPICAL
TC704
METAL PIPE THROUGH CONCRETE
FLOOR ASSEMBLY (3-HR.)
TC704
CABLE INSTALLATION AND SUPPORT
TYPES OF SUPPORT THAT ARE DISALLOWED
TC704
FIBER OPTIC PANEL
LABELING DETAIL
TC704
DATA CABLE
SUPPORT DETAILS AND REQUIREMENTS
TC704
DATA CABLE
DROP CEILING CABLE SUPPPORT. TYPICAL
TC704
FIBER OPTIC CABLE
LABELING
CAUTION
FIBER OPTIC CABLE
TYPE
COUNT
TC704
WIRELESS CABLE. HARD CEILING
CONDUIT TO ENCLOSURE
TC102
CONNECTIVITY CODE TC704
CABLING DETAILS
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
L A
TC
H
, R A
, N C
A R
B , D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
C om m te ch
D es ig n
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
AutoCAD SHX Text EMT CONDUIT SIZED AS SHOWN ON FLOORPLANS. EQUIP WITH: NYLON GROMMETS AT EACH END FIRESTOP SEALANT AROUND CONDUIT.
AutoCAD SHX Text
INSTALL PER UL SYSTEM W-L-1054. USE HILTI FS-ONE SEALANT OR EQUAL -TYPICAL
AutoCAD SHX Text
NYLON GROMMET-TYP.
AutoCAD SHX Text
EMT TYPE CONDUIT
AutoCAD SHX Text
INSTALL PER UL SYSTEM C-AJ-6017. USE HILTI FS-ONE SEALANT OR EQUAL -TYPICAL
AutoCAD SHX Text
NYLON GROMMET-TYP.
AutoCAD SHX Text
EMT TYPE CONDUIT
AutoCAD SHX Text EMT CONDUIT SIZED AS SHOWN ON FLOORPLANS. EQUIP WITH: NYLON GROMMETS AT EACH END FIRESTOP SEALANT AROUND CONDUIT.
AutoCAD SHX Text
INSTALL PER UL SYSTEM C-AJ-6017. USE HILTI FS-ONE SEALANT OR EQUAL -TYPICAL
AutoCAD SHX Text
HILTI FS-ONE SEALANT OR EQUAL -TYPICAL. MINIMUM 1/4" THICKNESS
AutoCAD SHX Text
NYLON GROMMET-TYP.
AutoCAD SHX Text
EMT TYPE CONDUIT
AutoCAD SHX Text EMT CONDUIT SIZED AS SHOWN ON FLOORPLANS. EQUIP WITH: NYLON GROMMETS AT EACH END FIRESTOP SEALANT AROUND CONDUIT.
AutoCAD SHX Text
PACKING MATERIAL. MINIMUM 4" MINERAL WOOL FIRMLY PACKED
AutoCAD SHX Text
INSTALL PER UL SYSTEM C-AJ-1150.
AutoCAD SHX Text
HILTI FS-ONE SEALANT OR EQUAL -TYPICAL. MINIMUM 1/4" THICKNESS
AutoCAD SHX Text
CABLES SHALL NOT REST ON HVAC DUCT
AutoCAD SHX Text
HVAC DUCT
AutoCAD SHX Text CABLES SHALL NOT BE ATTACHED OR REST DIRECTLY TO THREADED ROD OR OTHER ONTO PIPES
AutoCAD SHX Text DO NOT USE TY-WRAPS OR VELCRO TO ATTACH CABLES TO BUILDING STRUCTURE OR OTHER SUPPORTS
AutoCAD SHX Text
CABLES SHALL NOT REST ON CONDUIT NOR BE ATTACHED TO CONDUIT
AutoCAD SHX Text
CABLES SHALL NOT BE ATTACHED OR REST DIRECTLY TO BUILDING STEEL
AutoCAD SHX Text
CABLES SHALL NOT BE INSTALLED IN BETWEEN BUILDING STEEL AND ROOF
AutoCAD SHX Text
CABLES SHALL NOT BE INSTALLED THRU A WALL WITHOUT A CONDUIT PASS-THRU
AutoCAD SHX Text INSTALLATION NOTES: 1. CONTRACTOR SHALL INSTALL CABLES AROUND THE BUILDING AND CONTRACTOR SHALL INSTALL CABLES AROUND THE BUILDING AND SHALL SUPPORT CABLES AS PER NOTES, DETAILS AND INDUSTRY STANDARDS. 2. DO NOT USE ANY TY-WRAPS OR TAPE TO SUPPORT CABLES. DO NOT USE ANY TY-WRAPS OR TAPE TO SUPPORT CABLES. 3. DO NOT ATTACH CABLES TO BUILDING STEEL, CONDUITS OR PIPES. DO NOT ATTACH CABLES TO BUILDING STEEL, CONDUITS OR PIPES. 4. DO NOT INSTALL CONDUITS THRU A WALL WITHOUT INSTALLING DO NOT INSTALL CONDUITS THRU A WALL WITHOUT INSTALLING NYLON GROMMETS TO THE END OF THE CONDUIT PASS THRUS. 5. DO NOT ALLOW CABLES TO REST ON HVAC DUCTS.DO NOT ALLOW CABLES TO REST ON HVAC DUCTS.
AutoCAD SHX Text = TIE WRAPS OR VELCRO IS NOT TO BE TIE WRAPS OR VELCRO IS NOT TO BE USED FOR DIRECT SUPPORT OF CABLES TO PIPES, STEEL OR BUILDING STRUCTURE
AutoCAD SHX Text
ROUTING CABLES DIRECTLY THRU A WALL IS NOT ALLOWED. CONDUIT MUST BE INSTALLED
AutoCAD SHX Text
SIDE VIEW
AutoCAD SHX Text
FRONT VIEW
AutoCAD SHX Text
CABLE
AutoCAD SHX Text
STEEL
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
CONDUIT
AutoCAD SHX Text
ENGRAVED PHENOLIC LABEL
AutoCAD SHX Text
SC CONNECTOR PANEL
AutoCAD SHX Text
ENGRAVED PHENOLIC LABEL
AutoCAD SHX Text
ENGRAVED PHENOLIC LABEL
AutoCAD SHX Text
WALL MOUNT FIBER PANEL
AutoCAD SHX Text
FIBER TO XXYY
AutoCAD SHX Text
THIS IS CABINET CAB-002
AutoCAD SHX Text
FIBER TO XXYY
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
24 SM FIBER CABLE TO CAB-001
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
24 SM FIBER CABLE TO CAB-003
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CAB-001 / CAB-002 12-SM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text NOTES 1. THE FIBER PANELS AT THE RACK AND AT THE EXTERIOR CABINETS SHALL BE LABELED TO IDENTIFY THE FIBER. 2. LABELS IDENTIFYING THE FIBER CABLES SHALL BE ENGRAVED LABELS WITH BLACK BACKGROUND AND WHITE LETTERS. 3. SIZE THE LABELS TO MATCH THE SIZE OF THE PANEL. PROVIDE A SAMPLE TO THE OWNER AND ENGINEER PRIOR TO PURCHASING. 4. PROVIDE A WRAP-AROUND LABEL ON THE FIBER CABLE AS IT ENTERS THE PATCH PANEL. LASER PRINTED
AutoCAD SHX Text
ENGRAVED PHENOLIC LABEL (TYP)
AutoCAD SHX Text
ENGRAVED PHENOLIC LABEL
AutoCAD SHX Text
24 STRAND SM FIBER TO CAB-001
AutoCAD SHX Text
THIS IS CABINET CAB-002
AutoCAD SHX Text
24 STRAND SM FIBER TO CAB-003
AutoCAD SHX Text
BLANK
AutoCAD SHX Text
RACK MOUNT FIBER PANEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BLANK PANEL
AutoCAD SHX Text
ENGRAVED PHENOLIC LABEL (TYP)
AutoCAD SHX Text
WRAP AROUND LABEL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text INSTALLATION NOTES: 1. CONTRACTOR SHALL INSTALL CABLE SUPPORTS TO ENSURE CABLES CONTRACTOR SHALL INSTALL CABLE SUPPORTS TO ENSURE CABLES ARE NOT LAYING ON CONDUIT, WATERPIPE OR BUILDING STEEL. 2. CONTRACTOR SHALL INSTALL CABLE SUPPORTS SUCH AS J-HOOKS CONTRACTOR SHALL INSTALL CABLE SUPPORTS SUCH AS J-HOOKS AND BRIDLE RINGS TO SUPPORT CABLE EVERY 5' MINIMUM 3. WHEN ROUTING CABLES ALONG A WALL, ABOVE A CEILING OR WHEN ROUTING CABLES ALONG A WALL, ABOVE A CEILING OR ABOVE 12' AFF, INSTALL J-HOOKS ON WALL EVERY 5' MINIMUM OR AS REQUIRED TO KEEP CABLES FROM RESTING ON CEILING. 4. THERE SHALL BE ABSOLUTELY NO USE OF TAPE OR TY-WRAPS ON THERE SHALL BE ABSOLUTELY NO USE OF TAPE OR TY-WRAPS ON THE CABLES. USE ONLY VELCRO STRAPS ON CABLE. DO NOT SUPPORT CABLE DIRECTLY TO CONDUITS, PIPES OR BUILDING STEEL. 5. DO NOT USE DROP CEILING TILE WIRES TO SUPPORT CABLES. DO NOT USE DROP CEILING TILE WIRES TO SUPPORT CABLES. WHERE NO BUILDING STEEL OR WALL IS AVAILABLE INSTALL DROP CEILING WIRES AND ANCHORT TO BUILDING STEEL OR DIRECTLY INTO CONCRETE CEILING. 6. INSTALL CABLE SUPPORTS DIRECTLY ABOVE THE CAMERA OR WAP INSTALL CABLE SUPPORTS DIRECTLY ABOVE THE CAMERA OR WAP LOCATION. COIL CABLE AND SUPPORT ON A J-HOOK OR BRIDLE RING. USE VELCRO TO SECURE LOOP TO THE CABLE SUPPORT.
AutoCAD SHX Text
COIL OF CABLE
AutoCAD SHX Text
SURFACE BOX
AutoCAD SHX Text
INSTALL GREEN OR YELLOW STICKER DOT ON CEILING GRID
AutoCAD SHX Text DROP CEILING INSTALLATION WHERE THERE IS BUILDING STEEL WITHIN 24" OF DROP CEILING
AutoCAD SHX Text
J-HOOKS -TYP
AutoCAD SHX Text
COIL OF CABLE
AutoCAD SHX Text
SURFACE BOX
AutoCAD SHX Text
INSTALL GREEN OR YELLOW STICKER DOT ON CEILING GRID
AutoCAD SHX Text DROP CEILING INSTALLATION WHERE THERE IS BUILDING STEEL MOPE THAN 24" OF DROP CEILING
AutoCAD SHX Text
J-HOOKS -TYP
AutoCAD SHX Text
ATTACH J-HOOKS TO BLDG STEEL. CAN BE AT TOP, IN MIDDLE OR AT BOTTOM OF STEEL
AutoCAD SHX Text
SURFACE BOX
AutoCAD SHX Text
INSTALL CABLING ALONG WALL. OPEN CEILING ABOVE 12' OR ABOVE ACCESSIBLE CEILING
AutoCAD SHX Text
J-HOOKS -TYP
AutoCAD SHX Text ATTACH J-HOOKS TO THE WALL. INSTALL MINIMUM EVERY 5' AND AS CLOSE TO KEEP CABLES FROM CEILING
AutoCAD SHX Text
SURFACE BOX
AutoCAD SHX Text
INSTALL GREEN OR YELLOW STICKER DOT ON CEILING GRID
AutoCAD SHX Text
INSTALL CABLING WITH SUPPORT FROM THE CEILING
AutoCAD SHX Text
J-HOOKS -TYP
AutoCAD SHX Text ATTACH J-HOOKS TO THE WALL. INSTALL MINIMUM EVERY 5' AND AS CLOSE TO KEEP CABLES FROM CEILING
AutoCAD SHX Text
THREADED ROD OR 12 GA WIRE -TYP
AutoCAD SHX Text
SIDE VIEW
AutoCAD SHX Text
SURFACE BOX
AutoCAD SHX Text
INSTALL GREEN OR YELLOW STICKER DOT ON CEILING GRID
AutoCAD SHX Text
INSTALL CABLING WITH SUPPORT FROM THE CEILING
AutoCAD SHX Text
J-HOOKS -TYP
AutoCAD SHX Text ATTACH J-HOOKS TO THE WALL. INSTALL MINIMUM EVERY 5' AND AS CLOSE TO KEEP CABLES FROM CEILING
AutoCAD SHX Text
CEILING TILE WIRE. PAINTED GREEN
AutoCAD SHX Text
THREADED ROD OR 12 GA WIRE -TYP
AutoCAD SHX Text INSTALLATION NOTES: 1. CONTRACTOR SHALL INSTALL CABLE SUPPORTS TO ENSURE CABLES CONTRACTOR SHALL INSTALL CABLE SUPPORTS TO ENSURE CABLES ARE NOT LAYING ON CONDUIT, WATERPIPE OR BUILDING STEEL. 2. CONTRACTOR SHALL INSTALL CABLE SUPPORTS SUCH AS J-HOOKS CONTRACTOR SHALL INSTALL CABLE SUPPORTS SUCH AS J-HOOKS AND BRIDLE RINGS TO SUPPORT CABLE EVERY 5' MINIMUM 3. WHEN ROUTING CABLES ALONG A WALL, ABOVE A CEILING OR WHEN ROUTING CABLES ALONG A WALL, ABOVE A CEILING OR ABOVE 12' AFF, INSTALL J-HOOKS ON WALL EVERY 5' MINIMUM OR AS REQUIRED TO KEEP CABLES FROM RESTING ON CEILING. 4. THERE SHALL BE ABSOLUTELY NO USE OF TAPE OR TY-WRAPS ON THERE SHALL BE ABSOLUTELY NO USE OF TAPE OR TY-WRAPS ON THE CABLES. USE ONLY VELCRO STRAPS ON CABLE. DO NOT SUPPORT CABLE DIRECTLY TO CONDUITS, PIPES OR BUILDING STEEL. 5. DO NOT USE EXISTING DROP CEILING TILE WIRES TO SUPPORT DO NOT USE EXISTING DROP CEILING TILE WIRES TO SUPPORT CABLES. WHERE NO BUILDING STEEL OR WALL IS AVAILABLE INSTALL DROP CEILING WIRES AND ANCHOR TO BUILDING STEEL OR DIRECTLY INTO CONCRETE CEILING. ATTACH TO DROP CEILING. PAINT WIRES GREEN PRIOR TO INSTALLATION. 6. INSTALL CABLE SUPPORTS DIRECTLY ABOVE THE CAMERA OR WAP INSTALL CABLE SUPPORTS DIRECTLY ABOVE THE CAMERA OR WAP LOCATION. COIL CABLE AND SUPPORT ON A J-HOOK OR BRIDLE RING. USE VELCRO TO SECURE LOOP TO THE CABLE SUPPORT.
AutoCAD SHX Text KEYED NOTES: PROVIDE ADHESIVE LABEL ON FRONT OF EACH FIBER PANEL FOR LABELING THE FIBER CABLES INSTALL SELF-LAMINATING, WRAP-AROUND LABELS AT FIBER PANEL AND STOWAGE RING. INSTALL THE FIBER LABEL ON THE FIBER CABLE IN EACH HANDHOLE OR MANHOLE. PANDUIT #PST=FO
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text GENERAL NOTES: 1. INSTALL A WRAP-AROUND LABEL AT EACH END OF EACH CABLE AND AT THE INSTALL A WRAP-AROUND LABEL AT EACH END OF EACH CABLE AND AT THE HANDHOLES AND ON THE COIL ON THE WALL OF COMM ROOMS. 2. WRAP-AROUND LABELS SHALL BE LASER PRINTED AND SELF-LAMINATING AT THE WRAP-AROUND LABELS SHALL BE LASER PRINTED AND SELF-LAMINATING AT THE FIBER PANELS. 3. LABELS IN HANDHOLES AND AT THE COIL ON THE WALL SHALL BE PANDUIT LABELS IN HANDHOLES AND AT THE COIL ON THE WALL SHALL BE PANDUIT #PST-FO
AutoCAD SHX Text
RACK MOUNTED FIBER PANEL
AutoCAD SHX Text
12 STRAND, 50 MICRON TO COMM RM XXX XXX-YYY/XXX-YYY ZZAA
AutoCAD SHX Text
TYPICAL HANDHOLE
AutoCAD SHX Text
WRAP-AROUND LABEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LAMINATED LABEL DETAILING FIBER CABLES IN THE STOWAGE RING -TYPICAL
AutoCAD SHX Text
AutoCAD SHX Text
RACK MOUNTED FIBER PANEL
AutoCAD SHX Text
12 STRAND, 50 MICRON TO COMM RM XXX XXX-YYY/XXX-YYY ZZAA
AutoCAD SHX Text
AutoCAD SHX Text
PANDUIT FIBER LABEL
AutoCAD SHX Text
STOWAGE RING ON WALL OF COMM ROOM
AutoCAD SHX Text
STOWAGE RING ON WALL OF COMM ROOM
AutoCAD SHX Text
WRAP-AROUND LABEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text XXX-YYY/XXX-YYY ZZAA WRAP-AROUND LABEL XXX = CABINET OR BUILDING. CAB/ADM IN EXAMPLE YYY = CABINET NUMBER OR BUILDING ROOM # ZZ = FIBER STRAND COUNT AA = MULTIMODE MM OR SINGLEMODE SM
AutoCAD SHX Text
BUILDING NAME HERE
AutoCAD SHX Text
I.E.: SM
AutoCAD SHX Text I.E.: 24
AutoCAD SHX Text
PANDUIT FIBER LABEL DETAIL
AutoCAD SHX Text
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 CAT-6A CABLES-YELLOW -LONG DISTANCE CAT-6A CABLES-YELLOW -LONG DISTANCE SUPERIOR ESSEX PW6H-H72-6B 1 CAT-6A COUPLER WITH RJ-45 HUBBELL SCP6A CAT-6A COUPLER WITH RJ-45 HUBBELL SCP6A HUBBELL SCP6A SCP6A
AutoCAD SHX Text INSTALLATION NOTES: 1. PROVIDE A SHORT COIL OF CABLE AT TERMINATION LOCATION PROVIDE A SHORT COIL OF CABLE AT TERMINATION LOCATION INSIDE ENCLOSURE 2. PROVIDE A 12" CAT-6A PATCH CABLE. CONNECT TO CABLE JACK. PROVIDE A 12" CAT-6A PATCH CABLE. CONNECT TO CABLE JACK. 3. OWNER WILL PROVIDE WAPS AND WAP ENCLOSURE TO THE OWNER WILL PROVIDE WAPS AND WAP ENCLOSURE TO THE CONTRACTOR. INSTALL WAP AND DOCUMENT WAP ADDRESS AND NUMBER ON AS-BUILTS. 4. LABEL PATCH PANEL WITH WAP # LABEL PATCH PANEL WITH WAP # 5. EXTEND CONDUIT DIRECTLY TO THE WAP ENCLOSURE. CONNECT EXTEND CONDUIT DIRECTLY TO THE WAP ENCLOSURE. CONNECT WITH CONDUIT CONNECTIONS.
AutoCAD SHX Text
WIRELESS ACCESS POINT, CAT-6A SURFACE ENCLOSURE RACEWAY REQUIRED
AutoCAD SHX Text
%%UHARD DRYWALL CEILING INSTALLATION
AutoCAD SHX Text
INSTALL CAT-6A PATCH CABLE AND WAP
AutoCAD SHX Text
INSTALL 3/4" OR 1" CONDUIT
AutoCAD SHX Text
%%UHARD IN-ACCESSIBLE CEILING INSTALLATION
AutoCAD SHX Text
INSTALL 3/4" OR 1" CONDUIT
AutoCAD SHX Text
INSTALL OWNER PROVIDED WAP ENCLOSURE. OBERON #1020
AutoCAD SHX Text
INSTALL CAT-6A PATCH CABLE AND WAP
AutoCAD SHX Text
INSTALL OWNER PROVIDED WAP ENCLOSURE. OBERON #1020
AutoCAD SHX Text
CAT-6A CONNECTOR
AutoCAD SHX Text
AutoCAD SHX Text
CAT-6A CABLE TO RACK
AutoCAD SHX Text
PLUG RJ-45 INTO WAP
AutoCAD SHX Text
WAP
AutoCAD SHX Text
COBRA COUPLER
AutoCAD SHX Text
OR ROUTE THRU CEILING TO ACCESSIBLE AREA
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 GFI PLATE-STAINLESS HUBBELL SS26 GFI PLATE-STAINLESS HUBBELL SS26 HUBBELL SS26 SS26 1 ONE HOLE GFI PLATE HUBBELL NS611GY ONE HOLE GFI PLATE HUBBELL NS611GY HUBBELL NS611GY NS611GY 1 CAT-6A CABLE-YELLOW MOHAWK M59230 CAT-6A CABLE-YELLOW MOHAWK M59230 MOHAWK M59230 M59230 1 CAT-6A COBRA CONNECTOR HUBBELL HJU6AY CAT-6A COBRA CONNECTOR HUBBELL HJU6AY HUBBELL HJU6AY HJU6AY 1 CAT-6A PATCH CABLE HUBBELL HC6AY07CAT-6A PATCH CABLE HUBBELL HC6AY07HUBBELL HC6AY07HC6AY07
AutoCAD SHX Text
DATA
AutoCAD SHX Text INSTALLATION NOTES: 1. USE ONLY SECURITY SCREWS WITH THESE PLATES. USE ONLY SECURITY SCREWS WITH THESE PLATES. 2. WHERE NOTED THE CABLES SHALL BE INSTALLED THRU WHERE NOTED THE CABLES SHALL BE INSTALLED THRU SURFACE RACEWAY. 3. LABEL THE FACEPLATE WITH A LASER PRINTED LABELLABEL THE FACEPLATE WITH A LASER PRINTED LABEL
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
AutoCAD SHX Text
INSTALL YELLOW STICKER DOT ON CEILING GRID
AutoCAD SHX Text
SINGLE GANG BACKBOX
AutoCAD SHX Text
FACEPLATE
AutoCAD SHX Text
CAT-6A PATCH CABLE
AutoCAD SHX Text
CAT-6A CONNECTOR
AutoCAD SHX Text
CONDUIT. 3/4" MINIMUM
AutoCAD SHX Text
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text index no.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text sheet title
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
WI-FI CABLING INFRASTRUCTURE
AutoCAD SHX Text
LAKELAND CORRECTIONAL FACILITY
AutoCAD SHX Text
COLDWATER, MICHIGAN
AutoCAD SHX Text 5/20/25
AutoCAD SHX Text
ISSUE FOR BID
AutoCAD SHX Text 472ElectronicComm
AutoCAD SHX Text 1065_43
AutoCAD SHX Text Y17084
AutoCAD SHX Text
472/17032.RWG
AutoCAD SHX Text 6/13/25
AutoCAD SHX Text
ADDENDUM 01
TC708
POWER PLANT
COMM ROOM P1 RACK LAYOUT2
TC708
HOUSING UNIT B
COMM ROOM B1 RACK LAYOUT3
TC708
HOUSING UNIT C
COMM ROOM C1 RACK LAYOUT
TC708
HOUSING UNIT D
COMM ROOM D2 RACK LAYOUT 4
TC708
HOUSING UNIT D
COMM ROOM D1 RACK LAYOUT6
TC708
HOUSING UNIT E
COMM ROOM E1 RACK LAYOUT7
TC708
HOUSING UNIT F
COMM ROOM F1 RACK LAYOUT
TC708
WAREHOUSE
COMM ROOM W1 RACK LAYOUT
GENERAL RACK NOTES KEYED RACK NOTES
TC708
WAREHOUSE
COMM ROOM W2 RACK LAYOUT TC708
RACK LAYOUTS
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
L A
TC
H
, R A
, N C
A R
B , D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
C om m te ch
D es ig n
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ULTRALINK
AutoCAD SHX Text
24 PORT CISCO SWITCH
AutoCAD SHX Text
PCO-1
AutoCAD SHX Text
24 PORT HVAC PANEL
AutoCAD SHX Text
24 PORT HVAC SWITCH
AutoCAD SHX Text
12 PORT DTMB SWITCH
AutoCAD SHX Text
UPS
AutoCAD SHX Text
VALCOM
AutoCAD SHX Text
LAKELAND POWER PLANT COMM ROOM P1 EXISTING WALL CABINET P1-1
AutoCAD SHX Text
LAKELAND HOUSING UNIT B COMM ROOM B1 EXISTING CAM/DTMB/PPD RACK B1-1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FIBER OPTIC PANEL
AutoCAD SHX Text
FIBER OPTIC PANEL
AutoCAD SHX Text
8 PORT KEEFE SWITCH
AutoCAD SHX Text
24 PORT DTMB SWITCH
AutoCAD SHX Text
12 PORT DTMB PANEL
AutoCAD SHX Text
12 PORT DTMB PANEL
AutoCAD SHX Text
JPAY SWITCH
AutoCAD SHX Text
8 PORT JPAY SWITCH
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
48 PORT CAM SWITCH
AutoCAD SHX Text
CAM SWITCH
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
UPS
AutoCAD SHX Text
24 PORT GTL PANEL
AutoCAD SHX Text
24 PORT GTL SWITCH
AutoCAD SHX Text
GTL INTERFACE SWITCH
AutoCAD SHX Text
GTL INTERFACE SWITCH
AutoCAD SHX Text
UPS
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
48 PORT PPD PANEL
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
48 PORT PPD PANEL
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
ULTRALINK
AutoCAD SHX Text
SHELF/AMPLIFIER
AutoCAD SHX Text
UPS
AutoCAD SHX Text
UPS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LAKELAND HOUSING UNIT C COMM ROOM C1 EXISTING CAM/DTMB/PPD RACK C1-1
AutoCAD SHX Text
FIBER OPTIC PANEL
AutoCAD SHX Text
FIBER OPTIC PANEL
AutoCAD SHX Text
48 PORT CAM SWITCH
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
24 PORT DTMB SWITCH
AutoCAD SHX Text
12 PORT DTMB PANEL
AutoCAD SHX Text
12 PORT DTMB PANEL
AutoCAD SHX Text
8 PORT JPAY SWITCH
AutoCAD SHX Text
UPS
AutoCAD SHX Text
24 PORT GTL PANEL
AutoCAD SHX Text
24 PORT GTL SWITCH
AutoCAD SHX Text
GTL INTERFACE SWITCH
AutoCAD SHX Text
GTL INTERFACE SWITCH
AutoCAD SHX Text
UPS
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
48 PORT PPD PANEL
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
24 PORT PPD PANEL
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
ULTRALINK
AutoCAD SHX Text
SHELF/AMPLIFIER
AutoCAD SHX Text
UPS
AutoCAD SHX Text
UPS
AutoCAD SHX Text
8 PORT KEEFE SWITCH
AutoCAD SHX Text
JPAY SWITCH
AutoCAD SHX Text
LAKELAND HOUSING UNIT D COMM ROOM D2 EXISTING CAM/DTMB/PPD RACK D2-1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FIBER OPTIC PANEL
AutoCAD SHX Text
24 PORT SWITCH
AutoCAD SHX Text
FIBER OPTIC PANEL
AutoCAD SHX Text
12 PORT DTMB PANEL
AutoCAD SHX Text
12 PORT DTMB SWITCH
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
24 PORT PPD PANEL
AutoCAD SHX Text
PAGING INTERFACE
AutoCAD SHX Text
SHELF/AMPLIFIER
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
48 PORT CAM SWITCH
AutoCAD SHX Text
UPS
AutoCAD SHX Text
2 PORT CAM SWITCH
AutoCAD SHX Text
LAKELAND HOUSING UNIT D COMM ROOM D1 EXISTING CAM/DTMB RACK D1-1
AutoCAD SHX Text
2 PLUG POWER STRIP
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
24 PORT DTMB PANEL/PCO-1
AutoCAD SHX Text
24 PORT DTMB PANEL
AutoCAD SHX Text
12 PORT DTMB SWITCH
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
24 PORT DTMB PANEL/PCO-1
AutoCAD SHX Text
24 PORT DTMB PANEL/PCO-1
AutoCAD SHX Text
24 PORT DTMB PANEL/PCO-1
AutoCAD SHX Text
24 PORT CAM SWITCH
AutoCAD SHX Text
FIBER PANEL-1
AutoCAD SHX Text
LAKELAND HOUSING UNIT E COMM ROOM E1 EXISTING CAM/DTMB/PPD RACK E1-1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FIBER OPTIC PANEL
AutoCAD SHX Text
8 PORT KEEFE SWITCH
AutoCAD SHX Text
8 PORT JPAY SWITCH
AutoCAD SHX Text
JPAY POE
AutoCAD SHX Text
JPAY POE
AutoCAD SHX Text
12 PORT DTMB PANEL
AutoCAD SHX Text
12 PORT DTMB SWITCH
AutoCAD SHX Text
12 PORT CAM PANEL
AutoCAD SHX Text
24 PORT CAM SWITCH
AutoCAD SHX Text
SHELF/UPS
AutoCAD SHX Text
24 PORT GTL PANEL
AutoCAD SHX Text
24 PORT GTL SWITCH
AutoCAD SHX Text
GTL INTERFACE SWITCH
AutoCAD SHX Text
UPS
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
24 PORT PPD PANEL
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
ULTRALINK
AutoCAD SHX Text
SHELF/AMPLIFIER
AutoCAD SHX Text
UPS
AutoCAD SHX Text
LAKELAND HOUSING UNIT F COMM ROOM F1 EXISTING CAM/DTMB/PPD RACK F1-1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SHELF/FIBER OPTIC PANEL
AutoCAD SHX Text
8 PORT KEEFE SWITCH
AutoCAD SHX Text
8 PORT JPAY SWITCH
AutoCAD SHX Text
12 PORT DTMB PANEL
AutoCAD SHX Text
12 PORT DTMB SWITCH
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
24 PORT CAM SWITCH
AutoCAD SHX Text
UPS
AutoCAD SHX Text
24 PORT GTL PANEL
AutoCAD SHX Text
24 PORT GTL SWITCH
AutoCAD SHX Text
GTL INTERFACE SWITCH
AutoCAD SHX Text
UPS
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
24 PORT PPD PANEL
AutoCAD SHX Text
PPD PAGING INTERFACE
AutoCAD SHX Text
UPS
AutoCAD SHX Text
LAKELAND HOUSING UNIT B COMM ROOM B1 NEW 4-POST RACK B1-1
AutoCAD SHX Text
LAKELAND HOUSING UNIT C COMM ROOM C1 NEW 4-POST RACK C1-1
AutoCAD SHX Text
ATTACH PANEL BACK ONTO RACK.
AutoCAD SHX Text
FIBER PANEL
AutoCAD SHX Text
24 PORT CAT-6 WIFI
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PCO - 1
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text
LAKELAND HOUSING UNIT E COMM ROOM E1 NEW WALL RACK E1-1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
24 PORT CAT-6 WIFI
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
24 PORT CAT-6 WIFI
AutoCAD SHX Text A
AutoCAD SHX Text
PCO - 1
AutoCAD SHX Text
PCO - 1
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text W
AutoCAD SHX Text
AutoCAD SHX Text W
AutoCAD SHX Text
SHELF
AutoCAD SHX Text X
AutoCAD SHX Text
SHELF
AutoCAD SHX Text X
AutoCAD SHX Text H
AutoCAD SHX Text H
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FIBER OPTIC PANEL
AutoCAD SHX Text
FIBER OPTIC PANEL
AutoCAD SHX Text
8 PORT KEEFE SWITCH
AutoCAD SHX Text
24 PORT DTMB SWITCH
AutoCAD SHX Text
12 PORT DTMB PANEL
AutoCAD SHX Text
12 PORT DTMB PANEL
AutoCAD SHX Text
JPAY SWITCH
AutoCAD SHX Text
8 PORT JPAY SWITCH
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
48 PORT CAM SWITCH
AutoCAD SHX Text
CAM SWITCH
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
UPS
AutoCAD SHX Text
24 PORT GTL PANEL
AutoCAD SHX Text
24 PORT GTL SWITCH
AutoCAD SHX Text
GTL INTERFACE SWITCH
AutoCAD SHX Text
GTL INTERFACE SWITCH
AutoCAD SHX Text
UPS
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
48 PORT PPD PANEL
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
48 PORT PPD PANEL
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
ULTRALINK
AutoCAD SHX Text
SHELF/AMPLIFIER
AutoCAD SHX Text
UPS
AutoCAD SHX Text
UPS
AutoCAD SHX Text
PCO - 1
AutoCAD SHX Text C
AutoCAD SHX Text
MOVE EXISTING EQUIPMENT OUT OF 2 POST RACK INTO NEW 4-POST RACK AS SHOWN.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FIBER OPTIC PANEL
AutoCAD SHX Text
FIBER OPTIC PANEL
AutoCAD SHX Text
48 PORT CAM SWITCH
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
24 PORT DTMB SWITCH
AutoCAD SHX Text
12 PORT DTMB PANEL
AutoCAD SHX Text
12 PORT DTMB PANEL
AutoCAD SHX Text
8 PORT JPAY SWITCH
AutoCAD SHX Text
24 PORT GTL PANEL
AutoCAD SHX Text
24 PORT GTL SWITCH
AutoCAD SHX Text
GTL INTERFACE SWITCH
AutoCAD SHX Text
GTL INTERFACE SWITCH
AutoCAD SHX Text
UPS
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
48 PORT PPD PANEL
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
24 PORT PPD PANEL
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
ULTRALINK
AutoCAD SHX Text
SHELF/AMPLIFIER
AutoCAD SHX Text
UPS
AutoCAD SHX Text
UPS
AutoCAD SHX Text
8 PORT KEEFE SWITCH
AutoCAD SHX Text
JPAY SWITCH
AutoCAD SHX Text
PCO - 1
AutoCAD SHX Text C
AutoCAD SHX Text
SHELF
AutoCAD SHX Text X
AutoCAD SHX Text
SHELF
AutoCAD SHX Text X
AutoCAD SHX Text
UPS
AutoCAD SHX Text
24 PORT CAT-6 WIFI
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
24 PORT CAT-6 WIFI
AutoCAD SHX Text A
AutoCAD SHX Text
PCO - 1
AutoCAD SHX Text
PCO - 1
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text W
AutoCAD SHX Text
AutoCAD SHX Text W
AutoCAD SHX Text H
AutoCAD SHX Text H
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text MOVE EXISTING EQUIPMENT OUT OF 4 POST RACK INTO NEW 4-POST RACK AS SHOWN. FIELD VERIFY THAT ALL EXISTING EQUIPMENT WILL FIT AND NEW EQUIPMENT FOR WIFI.
AutoCAD SHX Text
AutoCAD SHX Text W
AutoCAD SHX Text H
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
24 PORT GTL PANEL
AutoCAD SHX Text
24 PORT GTL SWITCH
AutoCAD SHX Text
GTL INTERFACE SWITCH
AutoCAD SHX Text
UPS
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
24 PORT PPD PANEL
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
PAGING INTERFACE FOR PPD
AutoCAD SHX Text
SHELF/AMPLIFIER
AutoCAD SHX Text
UPS
AutoCAD SHX Text
FIBER OPTIC PANEL
AutoCAD SHX Text
8 PORT KEEFE SWITCH
AutoCAD SHX Text
8 PORT JPAY SWITCH
AutoCAD SHX Text
12 PORT DTMB PANEL
AutoCAD SHX Text
12 PORT DTMB SWITCH
AutoCAD SHX Text
12 PORT CAM PANEL
AutoCAD SHX Text
24 PORT CAM SWITCH
AutoCAD SHX Text
SHELF/UPS
AutoCAD SHX Text
PCO - 1
AutoCAD SHX Text C
AutoCAD SHX Text
PCO - 1
AutoCAD SHX Text C
AutoCAD SHX Text
24 PORT CAT-6 WIFI
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PCO - 1
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text W
AutoCAD SHX Text
AutoCAD SHX Text W
AutoCAD SHX Text H
AutoCAD SHX Text H
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MOVE EXISTING EQUIPMENT OUT OF 4 POST RACK. INTO NEW WALL RACK AS SHOWN.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LAKELAND WAREHOUSE COMM ROOM W1 EXISTING DTMB RACK W1-1
AutoCAD SHX Text
GND BAR
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
GND BAR
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
GND BAR
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
GND BAR
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
GND BAR
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
12 PORT EMPTY PANEL
AutoCAD SHX Text
12 PORT DTMB PANEL
AutoCAD SHX Text
FIBER OPTIC PANEL
AutoCAD SHX Text
24 PORT DTMB SWITCH
AutoCAD SHX Text
FIBER PANEL
AutoCAD SHX Text
24 PORT CAT-6 WIFI
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PCO - 1
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text
CAT-6, DTMB
AutoCAD SHX Text
AutoCAD SHX Text
12 CABLES
AutoCAD SHX Text H
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text W
AutoCAD SHX Text P
AutoCAD SHX Text
MOVE UPS TO BOTTOM OF CABINET
AutoCAD SHX Text
24 PORT CAT-6 WIFI
AutoCAD SHX Text
PCO - 1
AutoCAD SHX Text
RETERMINATE TWO EXISTING DTMB CABLES INTO PATCH PANEL
AutoCAD SHX Text
POWER STRIP
AutoCAD SHX Text Q
AutoCAD SHX Text
AutoCAD SHX Text
AF
AutoCAD SHX Text
AutoCAD SHX Text
1. VERIFY RACK EQUIPMENT AND SPACE IN THE RACK PRIOR TO VERIFY RACK EQUIPMENT AND SPACE IN THE RACK PRIOR TO INSTALLATION OF CABLES. 2. MOVE EXISTING PANELS AND OTHER EQUIPMENT UP OR DOWN AS MOVE EXISTING PANELS AND OTHER EQUIPMENT UP OR DOWN AS REQUIRED TO FIT THE NEW PATCH PANELS AND SWITCHES. 3. OWNER SHALL PROVIDE AND INSTALL ALL PATCH CABLES FOR FIBER OWNER SHALL PROVIDE AND INSTALL ALL PATCH CABLES FOR FIBER AND WAP CABLES AT THE RACKS AND ETHERNET SWITCH. 4. CONTRACTOR SHALL PROVIDE AND INSTALL CAT-6A PATCH CABLES AT CONTRACTOR SHALL PROVIDE AND INSTALL CAT-6A PATCH CABLES AT EACH WAP. 5. AT EACH RACK WHERE WAP CABLES ARE BEING INSTALLED THE AT EACH RACK WHERE WAP CABLES ARE BEING INSTALLED THE CONTRACTOR SHALL INCLUDE TIME TO ORGANIZER EXISTING CABLING AND POWER CORDS. ATTACH EXISTING CABLES TO THE CABLE LADDER AND TO THE WALL. GROUP WITH VELCRO TIES. 6. ORGANIZE ALL POWER CABLES THAT SERVE ITEMS IN THE RACK WHERE ORGANIZE ALL POWER CABLES THAT SERVE ITEMS IN THE RACK WHERE WAP CABLES ARE BEING INSTALLED. MOVE POWER STRIPS TO THE RACK AND NEATLY ROUTE ALL POWER CORDS 7. WHEN DIRECTED TO MOVE A RACK OR ROTATE A RACK, CONTRACTOR WHEN DIRECTED TO MOVE A RACK OR ROTATE A RACK, CONTRACTOR SHALL REMOVE EXISTING BOLTS FROM THE FLOOR AND SHALL INSTALL NEW BOLTS TO ATTACH RACK TO FLOOR AT NEW LOCATION 8. SEE TC704 FOR DETAILS ABOUT CABLE LADDER INSTALLATION AND SEE TC704 FOR DETAILS ABOUT CABLE LADDER INSTALLATION AND CABLE ROUTING
AutoCAD SHX Text PROVIDE VERTICAL SUPPORT OF CABLES AS THEY ROUTE FROM THE CEILING TO THE RACK. INSTALL 12" CABLE LADDER FROM RACK TO CEILING OR WALL. SUPPORT CABLE LADDER AT CEILING AND RACK WITH UNISTRUT ETC. SEE DETAILS ON TC705/4 OWNER TO INSTALL CAT-6A PATCH CABLES FROM CAT-6A PANEL TO THE WIFI SWITCH IN EACH RACK. LABEL EACH PORT IN THE PATCH PANEL WITH THE WAP NUMBER. INSTALL STICKER THAT IS LASER PRINTED AT JACK IN PANEL. SEE NEW PANEL LABELING DETAILS. INSTALL POWER STRIP. CONNECT TO OUTLET INSTALLED AS PART OF THIS PROJECT. SEE ELECTRICAL DRAWINGS FOR CIRCUIT. SEE TC705/3 MOVE EXISTING CABLES. REMOVE EXISTING DTMB CABLES FROM PANEL ON THE WALL. RE-ROUTE TO PATCH PANEL IN RACK. TERMINATE EXISTING DTMB CABLES. SEE INDIVIDUAL RACK LAYOUTS FOR CABLE QUANTITY. PROVIDE NEW PATCH PANEL WITH BLUE CAT-6 JACKS FOR CABLE TERMINATION. SPLICE EXISTING CABLES. UNTERMINATE EXISTING DTMB CABLES FROM PATCH PANEL. TERMINATE ON 110 BLOCKS. SPLICE NEW CAT-6 CABLES FROM 110 BLOCK TO NEW PATCH PANEL IN RACK. SEE TC705/2 FOR SPLICE AND EXTENSION DETAIL. SEE RACK DETAILS FOR QUANTITY OF CABLES TO EXTEND. INSTALL GROUND BAR. CONNECT TO ELECTRICAL PANEL GROUND. SEE DETAIL ON TC701/4 . INSTALL A VERTICAL ORGANIZER TO THE SIDE OF THE RACK. CONNECT RACK TO EXISTING GROUND BAR IN THIS ROOM. INSTALL CABLE LADDER FOR NEW 4 POST RACK AS SHOWN IN DETAIL TC705/4 AND FLOORPLAN INSTALL POWER STRIP. CONNECT TO OUTLET INSTALLED AS PART OF THIS PROJECT. SEE ELECTRICAL DRAWINGS FOR CIRCUIT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text P
AutoCAD SHX Text
FIBER PANEL-1
AutoCAD SHX Text H
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
24 PORT DTMB PANEL/PCO-1
AutoCAD SHX Text
24 PORT DTMB PANEL/PCO-1
AutoCAD SHX Text
24 PORT DTMB PANEL/PCO-1
AutoCAD SHX Text
24 PORT DTMB PANEL
AutoCAD SHX Text
24 PORT CAT-6 WIFI
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PCO - 1
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text
12 PORT DTMB SWITCH
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
24 PORT CAM SWITCH
AutoCAD SHX Text
SHELF
AutoCAD SHX Text U
AutoCAD SHX Text
AF
AutoCAD SHX Text REMOVE EXISTING RACK. INSTALL NEW WALL RACK. MOVE EXISTING EQUIPMENT OUT OF WALL RACK INTO NEW WALL RACK AS SHOWN.
AutoCAD SHX Text
SHELF
AutoCAD SHX Text Z
AutoCAD SHX Text
MOVE UPS TO THE SHELF
AutoCAD SHX Text
LAKELAND HOUSING UNIT D COMM ROOM D1 NEW WALL RACK D1-1
AutoCAD SHX Text
SHELF
AutoCAD SHX Text Z
AutoCAD SHX Text
MOVE UPS TO THE SHELF
AutoCAD SHX Text
AutoCAD SHX Text H
AutoCAD SHX Text
MOVE SWITCH AND FIBER PANEL UP IN RACK
AutoCAD SHX Text
SHELF
AutoCAD SHX Text U
AutoCAD SHX Text
JPAY POE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text W
AutoCAD SHX Text
AutoCAD SHX Text W
AutoCAD SHX Text H
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MOVE EXISTING EQUIPMENT OUT OF 4 POST RACK. INTO NEW WALL RACK AS SHOWN.
AutoCAD SHX Text P
AutoCAD SHX Text
SHELF
AutoCAD SHX Text H
AutoCAD SHX Text
AutoCAD SHX Text
SHELF/FIBER OPTIC PANEL
AutoCAD SHX Text
SHELF
AutoCAD SHX Text U
AutoCAD SHX Text
JPAY POE
AutoCAD SHX Text
8 PORT KEEFE SWITCH
AutoCAD SHX Text
8 PORT JPAY SWITCH
AutoCAD SHX Text
PCO - 1
AutoCAD SHX Text C
AutoCAD SHX Text
12 PORT DTMB PANEL
AutoCAD SHX Text
24 PORT CAT-6 WIFI
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
12 PORT DTMB SWITCH
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
24 PORT CAM SWITCH
AutoCAD SHX Text
UPS
AutoCAD SHX Text
24 PORT GTL PANEL
AutoCAD SHX Text
24 PORT GTL SWITCH
AutoCAD SHX Text
GTL INTERFACE SWITCH
AutoCAD SHX Text
UPS
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
24 PORT PPD PANEL
AutoCAD SHX Text
PPD PAGING INTERFACE
AutoCAD SHX Text
SHELF
AutoCAD SHX Text
UPS
AutoCAD SHX Text
INSTALL PLYWOOD BEHIND RACK FOR MOUNTING
AutoCAD SHX Text
INSTALL PLYWOOD BEHIND RACK FOR MOUNTING
AutoCAD SHX Text
INSTALL PLYWOOD BEHIND RACK FOR MOUNTING
AutoCAD SHX Text
LAKELAND HOUSING UNIT F COMM ROOM F1 NEW WALL RACK F1-1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text
LAKELAND WAREHOUSE COMM ROOM W2 NEW WALL CABINET W2-1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FIBER PANEL
AutoCAD SHX Text
24 PORT DTMB PANEL/PCO-2
AutoCAD SHX Text
24 PORT DTMB SWITCH
AutoCAD SHX Text
LAKELAND WAREHOUSE COMM ROOM W2 EXISTING WALL RACK W2-1 REPLACE
AutoCAD SHX Text
FIBER PANEL
AutoCAD SHX Text
24 PORT DTMB PANEL/PCO-2
AutoCAD SHX Text
24 PORT DTMB SWITCH
AutoCAD SHX Text
24 PORT CAT-6 WIFI
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PCO - 1
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text REMOVE EXISTING WALL RACK. INSTALL NEW WALL CABINET. MOVE EXISTING EQUIPMENT OUT OF WALL RACK INTO NEW WALL CABINET AS SHOWN.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text L
AutoCAD SHX Text
GND BAR
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text H
AutoCAD SHX Text
AutoCAD SHX Text H
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text index no.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text sheet title
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
WI-FI CABLING INFRASTRUCTURE
AutoCAD SHX Text
LAKELAND CORRECTIONAL FACILITY
AutoCAD SHX Text
COLDWATER, MICHIGAN
AutoCAD SHX Text 5/20/25
AutoCAD SHX Text
ISSUE FOR BID
AutoCAD SHX Text 472ElectronicComm
AutoCAD SHX Text 1065_43
AutoCAD SHX Text Y17084
AutoCAD SHX Text
472/17032.RWG
AutoCAD SHX Text 6/13/25
TC809A
SERVICE BUILDING/
WAREHOUSE
FIRST FLOOR
WI-FI NETWORK
TC809A
SERVICE BUILDING/WAREHOUSE
FIRST FLOOR - WI-FI NETWORKN
KEYED CABLING NOTES
GENERAL WI-FI NOTES
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
L A
TC
H
, R A
, N C
A R
B , D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
C om m te ch
D es ig n
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
AutoCAD SHX Text W1
AutoCAD SHX Text
COMM ROOM
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 12'-4 1/2" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 9'-2" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 8'-0" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 8'-0" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 8'-9" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 9'-0" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 9'-1" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 9'-1" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 9'-1" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 11'-10" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 9'-0" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 9'-0" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 8'-11 1/2" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 12'-5" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 12'-5" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 7'-6" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 7'-6" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 7'-6" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 7'-6" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 16'-2" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 12'-7" AFF
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 9'-2" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 9'-1" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 15'-11" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 12-5" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 12-4" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 12-5" AFF
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 8-3 1/2" AFF
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
RECORDS
AutoCAD SHX Text
GARAGE DOOR
AutoCAD SHX Text
HT 12'-0"
AutoCAD SHX Text
GARAGE DOOR
AutoCAD SHX Text
HT 12'-0"
AutoCAD SHX Text
GARAGE DOOR
AutoCAD SHX Text
HT 12'-0"
AutoCAD SHX Text
SHIPPING/RECEIVING
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 8-3 1/2" AFF
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 8'-1" AFF
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
DELIVERY
AutoCAD SHX Text
CLG: GYP BOARD CLG HT: 12'-5" AFF
Au…
This is the start of the file's text. The full file is on GovTribe.