This is a comprehensive technical drawing document for Wi-Fi cabling infrastructure at Alger Correctional Facility in Munising, Michigan, prepared by the Michigan Department of Technology, Management and Budget for a state of Michigan capital project issued for bid on December 16, 2024. The project involves designing and installing a complete wireless access point (WAP) cabling infrastructure system across multiple buildings including Administration (Building 100), Support Services (Building 200), Education (Building 300), Maintenance/Warehouse (Building 500), and six housing units (Aspen, Birch, Cedar, Maple, Pine, and Spruce). The scope encompasses installation of CAT-6A and CAT-6 data cabling, patch panels, cable trays, grounding systems, fiber optic backbone connectivity, communication rooms with rack-mounted equipment, and exterior WAP installations. The project includes approximately 26 wireless access points distributed across interior and exterior locations with detailed specifications for cable types, termination methods, support requirements, and labeling conventions. Technical drawings are organized by building and floor level with connectivity diagrams showing network architecture, rack layouts, and cable routing paths.
The specifications require the contractor to provide vertical cable support via cable ladder systems, J-hooks installed at minimum five-foot intervals, and conduit installations with firestop protection through fire-rated assemblies. All cables must be labeled with laser-printed, self-laminating wrap-around labels following a specific coding system. Grounding systems must be installed per specifications with #6 AWG green ground cables and phosphor bronze bolts. The owner will provide and install all Ethernet switches, fiber optic patch cables, and wireless access points (Cisco equipment), while the contractor is responsible for all CAT-6A patch cables at WAP locations, cable ladder systems, conduit work, power strips, and horizontal cable management. The project documentation includes detailed equipment schedules specifying manufacturers and part numbers for Hubbell, Ortronics, Chatsworth, Leviton, and other vendors. No pricing information, contract award date, or project timeline completion dates are specified in these technical design drawings, which serve as the basis for competitive bidding by qualified communications contractors.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TC701
TYPICAL CABLE LABELING
AT SURFACE BOX & PATCH PANEL 1
TC701
CAT-6 DATA PANEL
TYPICAL LABELING
ABBREVIATIONS
ABBREV. DESCRIPTION ABBREV. DESCRIPTION
TC701
PATCH CABLE DIAGRAM
TYPICAL CONNECTITY
CABLE SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
NETWORK EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
TC701
COMMUNICATIONS GROUNDING DETAIL
COMMUNICATION SYMBOL LEGEND
SYMBOL DESCRIPTION
COMMUNICATION EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
TC701
CABLING LEGENDS AND
DETAILS
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
L A
TC
H
, R A
, N C
A R
B , D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
C om m te ch
D es ig n
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
AutoCAD SHX Text
YY-APZZ
AutoCAD SHX Text
ADHESIVE LABEL
AutoCAD SHX Text
WRAP-AROUND LABEL
AutoCAD SHX Text 33-3204-02
AutoCAD SHX Text
WRAP-AROUND LABEL
AutoCAD SHX Text 33-3204-02
AutoCAD SHX Text
CAT-6 CABLE
AutoCAD SHX Text
BACK OF PATCH PANEL IN COMM ROOM
AutoCAD SHX Text NOTES: 1. INSTALL A WRAP-AROUND LABEL AT EACH END OF EACH CABLE. INSTALL A WRAP-AROUND LABEL AT EACH END OF EACH CABLE. 2. WRAP-AROUND LABELS SHALL BE LASER-PRINTED AND SHALL BE WRAP-AROUND LABELS SHALL BE LASER-PRINTED AND SHALL BE SELF-LAMINATING. 3. LABEL ALL SURFACE MOUNT BOXES WITH THE SAME CABLE NUMBER AS LABEL ALL SURFACE MOUNT BOXES WITH THE SAME CABLE NUMBER AS THE CABLE IS NUMBERED
AutoCAD SHX Text CABLE LABEL: XX = COMM ROOM NUMBER. SEE FLOORPLANS YY = FLOOR DESIGNATION BB=BASEMENT. LL=LOWER LEVEL. UL= UPPER LEVEL EX = EXTERIOR AP = WAP ZZ = AP NUMBER. O1 THRU 99
AutoCAD SHX Text NOTES: 1. LABEL EACH PATCH PANEL IN THE RACK WITH THE BUILDING AND LABEL EACH PATCH PANEL IN THE RACK WITH THE BUILDING AND THE FLOOR WHERE THE WAPS ARE INSTALLED. 2. INSTALL A LABEL TO EACH PATCH PORT ON THE PANEL DETAILING INSTALL A LABEL TO EACH PATCH PORT ON THE PANEL DETAILING THE WAP NUMBER. REFER TO SPREADSHEET PROVIDED BY STATE OF MICHIGAN AT TIME OF INSTALLATION. 3. ALL LABELS ADDED TO THE PANEL SHALL BE LASER PRINTED AND ALL LABELS ADDED TO THE PANEL SHALL BE LASER PRINTED AND CUT TO FIT. ALL NUMBERS SHALL EXACTLY ALIGN WITH THE LOCATION ON THE PATCH PANEL. 4. LABEL THE CABLES AT THE BACK OF THE PATCH PANEL WITH A LABEL THE CABLES AT THE BACK OF THE PATCH PANEL WITH A WRAP AROUND, LASER PRINTED, SELF-ADHESIVE LABEL. 5. THE CABLES SHALL BE TERMINATED ON THE PATCH PANEL IN THE CABLES SHALL BE TERMINATED ON THE PATCH PANEL IN NUMERICAL ORDER. NO EXCEPTIONS. 6. PROVIDE AND INSTALL A PATCH PANEL FOR EACH FLOOR OF A PROVIDE AND INSTALL A PATCH PANEL FOR EACH FLOOR OF A BUILDING WHERE WAPS ARE ON MULTIPLE FLOORS. 7. COMBINE BASEMENT CABLES OR MEZZANINE CABLES WITH EXTERIOR COMBINE BASEMENT CABLES OR MEZZANINE CABLES WITH EXTERIOR CABLES AND INSTALL ON THEIR OWN PATCH PANEL. EXTERIOR CABLES SHALL START ON THE RIGHT SIDE OF THE PATCH PANEL AND WORK TOWARDS THE MIDDLE.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LABEL PATCH PANEL USING INFORMATION FROM THE WAP LABELS
AutoCAD SHX Text
ADHESIVE LABEL (TYPICAL)
AutoCAD SHX Text 2G
AutoCAD SHX Text
TWO-GANG BOX - PROVIDED BY EC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NOT IN CONTRACT
AutoCAD SHX Text
AC
AutoCAD SHX Text ABOVE COUNTER - INSTALL BACKBOX SAME HEIGHT AS OTHER ELECTRICAL OUTLETS ABOVE THE COUNTER.
AutoCAD SHX Text
PBO
AutoCAD SHX Text
PROVIDED BY OTHERS
AutoCAD SHX Text
AFF
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text
PCO-1
AutoCAD SHX Text
PATCH CORD ORGANIZER - 1 UNIT HIGH
AutoCAD SHX Text
AFG
AutoCAD SHX Text
ABOVE FINISHED GROUND
AutoCAD SHX Text
PCO-2
AutoCAD SHX Text
PATCH CORD ORGANIZER - 2 UNITS HIGH
AutoCAD SHX Text
AWG
AutoCAD SHX Text
AMERICAN WIRE GAUGE
AutoCAD SHX Text
PET
AutoCAD SHX Text
PROTECTED ENTRANCE TERMINAL
AutoCAD SHX Text
EMT
AutoCAD SHX Text
EMT TYPE CONDUIT
AutoCAD SHX Text
QTY
AutoCAD SHX Text
QUANTITY
AutoCAD SHX Text
EC
AutoCAD SHX Text
ELECTRICAL CONTRACTOR
AutoCAD SHX Text
%%UWIRELESS ACCESS POINT
AutoCAD SHX Text
YELLOW PATCH CABLES ARE TO BE PROVIDED AND INSTALLED BY OWNER
AutoCAD SHX Text GENERAL NOTES: 1. ALL PATCH CORDS BETWEEN PANEL AND ETHERNET SWITCH ARE ALL PATCH CORDS BETWEEN PANEL AND ETHERNET SWITCH ARE PROVIDED AND INSTALLED BY THE OWNER. 2. PROVIDE AND INSTALL PATCH CABLE AT THE WAP. SEE DETAILS PROVIDE AND INSTALL PATCH CABLE AT THE WAP. SEE DETAILS ON SHEET TC702 FOR PATCH CABLE AND CONNECTIVITY DETAILS.
AutoCAD SHX Text
PROVIDE AND INSTALL A CAT-6A PATCH CABLE, YELLOW, SEE DETAILS ON TC702
AutoCAD SHX Text
CAT-6A WAP CABLE
AutoCAD SHX Text
PATCH PANEL IN THE COMM ROOM
AutoCAD SHX Text
ETHERNET SWITCH IN THE COMM ROOM -PROVIDED BY OWNER
AutoCAD SHX Text
YELLOW PATCH CABLE FOR WAPS
AutoCAD SHX Text
CAT-6A CONNECTION
AutoCAD SHX Text
LL AP01
AutoCAD SHX Text
LABEL PATCH PANELS WITH THE WAP NUMBER
AutoCAD SHX Text
CAT-6A UTP CABLES FOR WIRELESS ACCESS POINTS SHALL BE YELLOW IN COLOR
AutoCAD SHX Text
MOHAWK
AutoCAD SHX Text M59230
AutoCAD SHX Text
CAT-6 UTP CABLES FOR DTMB CONNECTIVITY. SHALL BE BLUE IN COLOR
AutoCAD SHX Text
MOHAWK
AutoCAD SHX Text M58281
AutoCAD SHX Text
CAT-6A UNDERGROUND CABLES. SHALL BE BLACK IN COLOR
AutoCAD SHX Text
MOHAWK
AutoCAD SHX Text M59199
AutoCAD SHX Text
CATEGORY UTP CABLE, INDOOR, PLENUM RATED, EXTENDED DISTANCE. YELLOW
AutoCAD SHX Text
SUPERIOR ESSEX
AutoCAD SHX Text
PW6H-H72-6B
AutoCAD SHX Text
CATEGORY UTP CABLE, OUTDOOR, UNDERGOUND RATED, EXTENDED DISTANCE. BLACK
AutoCAD SHX Text
SUPERIOR ESSEX
AutoCAD SHX Text
PWO4-401-58
AutoCAD SHX Text
12 STRAND SINGLEMODE FIBER CABLE, PLENUM RATED -ARMORED
AutoCAD SHX Text
OCC
AutoCAD SHX Text
DZ012TSLX9YP18
AutoCAD SHX Text
12 STRAND SINGLEMODE FIBER CABLE, OUTDOOR RATED
AutoCAD SHX Text
OCC
AutoCAD SHX Text
DX012DSLX9KR
AutoCAD SHX Text
24 STRAND SINGLEMODE FIBER CABLE, OUTDOOR RATED
AutoCAD SHX Text
OCC
AutoCAD SHX Text
DX024DSLX9KR
AutoCAD SHX Text
12 STRAND MULTIMODE FIBER CABLE, 50 MICRON, PLENUM RATED -ARMORED
AutoCAD SHX Text
OCC
AutoCAD SHX Text
DZ012TALT9QP18
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text CORE ETHERNET SWITCH. PROVIDED BY OWNER. MOUNT IN RACK, INSTALL AND CONNECT TO INCOMING INTERNET, WIRELESS CONTROLLERS AND SWITCHES IN ALL OTHER BUILDINGS. PROVIDE ALL PATCH CORDS FOR CONNECTIVITY. INSTALL AND CONNECT
AutoCAD SHX Text
CISCO
AutoCAD SHX Text
PROVIDED AND INSTALLED BY OWNER
AutoCAD SHX Text BUILDING ETHERNET SWITCH 48 PORT. PROVIDED BY OWNER. MOUNT IN RACK, INSTALL AND CONNECT. PROVIDE ALL PATCH CORDS FOR FIBER AND WAP CONNECTIVITY.
AutoCAD SHX Text
CISCO
AutoCAD SHX Text
PROVIDED AND INSTALLED BY OWNER
AutoCAD SHX Text WIRELESS ACCESS POINT (WAP) INDOOR OR OUTDOOR. PROVIDED BY OWNER. INSTALL AND MOUNT AT THE LOCATIONS SHOWN ON FLOORPLANS. PROVIDE PATCH CABLE AT THE WAP LOCATION. PROVIDE HARDWARE REQUIRED FOR MOUNTING. OWNER TO PROVIDE MANUFACTURERS MOUNTS.
AutoCAD SHX Text
CISCO
AutoCAD SHX Text
PROVIDED BY OWNER INSTALLED BY CONTRACTOR
AutoCAD SHX Text
NA
AutoCAD SHX Text
NB
AutoCAD SHX Text
NC
AutoCAD SHX Text
LL AP02
AutoCAD SHX Text
LL AP03
AutoCAD SHX Text
LL AP04
AutoCAD SHX Text
LL AP05
AutoCAD SHX Text
LL AP06
AutoCAD SHX Text
LL AP07
AutoCAD SHX Text
LL AP088
AutoCAD SHX Text
LL AP09
AutoCAD SHX Text
LL AP10
AutoCAD SHX Text
LL AP11
AutoCAD SHX Text
LL AP12
AutoCAD SHX Text
LL AP13
AutoCAD SHX Text
XX-YY-APZZ
AutoCAD SHX Text
XX-YY-APZZ
AutoCAD SHX Text CABLE LABEL: XX = COMM ROOM NUMBER. SEE FLOORPLANS YY = FLOOR DESIGNATION BB=BASEMENT. LL=LOWER LEVEL. UL= UPPER LEVEL EX = EXTERIOR AP = WAP ZZ = AP NUMBER. O1 THRU 99
AutoCAD SHX Text
BLDG
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text
PROVIDE AND INSTALL GROUND BAR AT EACH COMM ROOM
AutoCAD SHX Text
TYPICAL CRIMP LUG CONNECTIVITY
AutoCAD SHX Text GROUNDING NOTES: 1. INSTALL GROUND BAR AT EACH COMM ROOM. INSTALL GROUND BAR AT EACH COMM ROOM. 2. CONNECT THE GROUND BAR AS SHOWN IN THIS DIAGRAM CONNECT THE GROUND BAR AS SHOWN IN THIS DIAGRAM & AS DIRECTED IN THE GROUNDING SPECIFICATIONS. 3. ALL GROUND CONNECTIONS SHALL BE MADE WITH CRIMP ALL GROUND CONNECTIONS SHALL BE MADE WITH CRIMP LUGS ONLY. THIS APPLIES TO ALL CONNECTIONS TO THE GROUND BAR & THE CONNECTIONS TO THE ASSOCIATED EQUIPMENT. 4. GROUND CONNECTIONS SHALL BE MADE WITH A MINIMUM GROUND CONNECTIONS SHALL BE MADE WITH A MINIMUM OF #6 AWG CABLE. CABLES SHALL BE EQUIPPED WITH A GREEN SHEATH. 5. ALL CONNECTIONS TO THE GROUND BAR SHALL BE MADE ALL CONNECTIONS TO THE GROUND BAR SHALL BE MADE WITH PHOSPHER BRONZE BOLTS & NUTS. 6. ALL GROUND WIRES SHALL HAVE GREEN INSULATION ALL GROUND WIRES SHALL HAVE GREEN INSULATION UNLESS INSTALLED IN A PLENUM AREA. GROUND CABLES THAT MUST BE INSTALLED IN A PLENUM AREA SHALL BE BARE COPPER WIRE WITH GREEN TAPE AT ENDS. 7. INSTALL THE GROUND WIRE TO GROUND BUS ON INSTALL THE GROUND WIRE TO GROUND BUS ON ELECTRICAL PANEL
AutoCAD SHX Text
TELECOMMUNICATIONS GROUND BAR
AutoCAD SHX Text
BUILDING STEEL
AutoCAD SHX Text
LOCAL RECEPT. PANEL
AutoCAD SHX Text
#6 AWG
AutoCAD SHX Text
EXISTING RACK OR CABINET
AutoCAD SHX Text
NEW RACK OR CABINET
AutoCAD SHX Text
COMMUNICATIONS CABLE TRAY AND CABLE LADDER
AutoCAD SHX Text
PROTECTED ENTRANCE TERMINAL
AutoCAD SHX Text
#6 AWG
AutoCAD SHX Text
#6 AWG
AutoCAD SHX Text
#6 AWG
AutoCAD SHX Text
TYPICAL FOR ALL GROUND BARS
AutoCAD SHX Text
#6 AWG
AutoCAD SHX Text
AutoCAD SHX Text
TYPICAL ELECTRICAL PANEL
AutoCAD SHX Text
GROUND BUS
AutoCAD SHX Text
#6 AWG GREEN GROUND CABLE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EQUIPMENT SCHEDULE, SEE DETAILS AND EQUIPMENT SCHEDULES ON TC101 ETC.
AutoCAD SHX Text
CABLE SCHEDULE, SEE COMMUNICATIONS CABLE SCHEDULE
AutoCAD SHX Text
KEYNOTES. REFER TO NOTES ON THE SHEET FOR ADDITIONAL INFORMATION
AutoCAD SHX Text DATA COMMUNICATIONS OUTLET CONNECTIVITY CODE. X IS A 1 THRU 99. SEE TC7XX SHEETS FOR SPECIFIC REQUIREMENTS. XXXX NOTES THAT THE CABLE IS FOR A SPECIFIC USE
AutoCAD SHX Text
INSTALL NEW WIRELESS ACCESS POINT. SEE DETAILS AND SPREADSHEET
AutoCAD SHX Text
INSTALL NEW EXTERIOR WIRELESS ACCESS POINT. SEE DETAILS AND SPREADSHEET
AutoCAD SHX Text
INSTALL NEW EXTERIOR WIRELESS ACCESS POINT. SEE DETAILS AND SPREADSHEET
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WAP-X
AutoCAD SHX Text X
AutoCAD SHX Text
XXXX
AutoCAD SHX Text
WAP-E2
AutoCAD SHX Text
WAP-E3
AutoCAD SHX Text
BLDG XX
AutoCAD SHX Text PATCH PANEL-24 PORT, EQUIPPED WITH 8-PIN MODULAR . PATCH PANEL SHALL BE COMPLETELY FILLED WITH MODULAR JACKS. NO OPENINGS ARE ALLOWED AT PROJECT COMPLETION. INSTALL YELLOW CAT-6A MODULAR CONNECTORS TO FILL THE PATCH PANEL. EQUIP WITH REAR CABLE ORGANIZER.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
PANEL:HPJ24 ORGANIZER:ECMBR3
AutoCAD SHX Text PATCH PANEL-24 PORT, EQUIPPED WITH 8-PIN MODULAR JACKS. FOR CAT-6 CABLES. THE PATCH PANEL SHALL BE COMPLETELY FILLED WITH MODULAR JACKS. NO OPENINGS ARE ALLOWED AT PROJECT COMPLETION. INSTALL BLUE CAT-6 MODULAR CONNECTORS TO FILL THE PATCH PANEL. EQUIP WITH REAR CABLE ORGANIZER.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
PANEL:HPJ24 ORGANIZER:ECMBR3
AutoCAD SHX Text
SINGLE RACK UNIT PATCH CORD ORGANIZER (PCO-1) WITH HINGED COVER.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
HC119ME3N/HC119C
AutoCAD SHX Text
TWO RACK UNIT PATCH CORD ORGANIZER (PCO-2) WITH HINGED COVER.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
HC2119ME3N/HC219C
AutoCAD SHX Text TELECOMMUNICATIONS GROUND BAR (TGB). 1/4"x4"x10" EQUIPPED WITH INSULATED STAND-OFFS.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
HBBB14210A
AutoCAD SHX Text 2-POST RACK:7'x19" BLACK RELAY RACK EQUIPPED WITH ONE FULL-LENGTH 6" VERTICAL ORGANIZER. RELAY RACK IS TO BE CONFIGURED WITH VERTICAL & HORIZONTAL CABLE LADDER AS SHOWN ON THE DRAWINGS AND AS DESCRIBED IN THE SPECS.
AutoCAD SHX Text
ORTRONICS
AutoCAD SHX Text
19-84-T2SD-B
AutoCAD SHX Text 4-POST ADJUSTABLE RACK. PUNCHED 3/8" HOLES. EQUIP WITH TWO 6" VERTICAL ORGANIZERS. EQUIP WITH CAGE NUTS FOR 19" RACK COMPONENTS. EQUIP WIITH CABLE LADDER AS PER SPECS AND DETAILS.
AutoCAD SHX Text
ORTRONICS
AutoCAD SHX Text
19-84-SSDA2132
AutoCAD SHX Text POWER STRIP, VERTICAL, FOR BACK OF EACH RACK. SALL HAVE (6) NEMA 5-20R RECEPTACLES AND SHALL BE 18" LONG. PLUG INTO WALL OUTLET. ATTACH THE POWER STRIP TO THE BACK OF THE VERTICAL CABLE LADDER OF EACH RACK.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
PV3620A12S
AutoCAD SHX Text 24" TALL WALL MOUNT CABINET. 12 RACK UNITS. 26" DEEP. INCLUDE PLEXIGLAS FRONT DOOR AND POWER STRIP, RACK MOUNTED POWER STRIP
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
HSQ2426
AutoCAD SHX Text 36" TALL WALL MOUNT CABINET. 18 RACK UNITS. 26" DEEP. INCLUDE PLEXIGLAS FRONT DOOR AND POWER STRIP, RACK MOUNTED POWER STRIP
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
HSQ3626
AutoCAD SHX Text 48" TALL WALL MOUNT CABINET. 24 RACK UNITS. 26" DEEP.INCLUDE PLEXIGLAS FRONT DOOR AND POWER STRIP, RACK MOUNTED POWER STRIP
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
HSQ4826
AutoCAD SHX Text
29" TALL WALL RACK. 12 RACK UNITS. 24" DEEP. INCLUDE POWER STRIP
AutoCAD SHX Text
CHATSWORTH
AutoCAD SHX Text 11790-X25
AutoCAD SHX Text
43" TALL WALL RACK. 20 RACK UNITS. 24" DEEP. INCLUDE POWER STRIP
AutoCAD SHX Text
CHATSWORTH
AutoCAD SHX Text 11791-X25
AutoCAD SHX Text
53" TALL WALL RACK. 26 RACK UNITS. 24" DEEP. INCLUDE POWER STRIP
AutoCAD SHX Text
CHATSWORTH
AutoCAD SHX Text 11807-X25
AutoCAD SHX Text
78" TALL WALL RACK. 40 RACK UNITS. 24" DEEP. INCLUDE POWER STRIP
AutoCAD SHX Text
CHATSWORTH
AutoCAD SHX Text 11792-X25
AutoCAD SHX Text POWER STRIP, RACK MOUNT, PROVIDE FOR EACH RACK OR CABINET WHERE WIFI CABLES ARE BEING TERMINATED
AutoCAD SHX Text
TRIPP LITE
AutoCAD SHX Text
PDUMH20-ISO
AutoCAD SHX Text 110 STYLE SPLICE BLOCKS. WALL MOUNTED. 16 CABLES SPLICED AT WALL FOR EXTENSION TO NEW PATCH PANEL
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
6110FTK64WL W/ CONNECTORS 6110CB4PR13 AND LABEL STRIP XPL1101OW
AutoCAD SHX Text FIBER OPTIC CABLE STOWAGE RING. WALL MOUNTED. 12" OR 24". PROVIDE AND INSTALL TO SUPPORT BEND RADIUS REQUIREMENTS OF THE FIBER CABLE`
AutoCAD SHX Text
LEVITON
AutoCAD SHX Text
24" #48900-OFR
AutoCAD SHX Text RACK MOUNT FIBER PANEL. USE WHEN TERMINATING 24 OR LESS FIBER STRANDS. PROVIDE EACH FIBER PANEL WITH "SC" SIX OR 12 PACKS AS REQUIRED FOR TERMINATION OF ALL FIBERS. PROVIDE SPLICE TRAY AND SHELF FOR FUSION SPLICES TO PIGTAILS.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
FPR3SP
AutoCAD SHX Text
RACK MOUNT SHELF. MESH BASE WITH 14" DEPTH MINIMUM
AutoCAD SHX Text
MIDDLE ATLANTIC
AutoCAD SHX Text
UFA-14.5
AutoCAD SHX Text HANDHOLE. SHALL BE 36" LONG, 24" WIDE AND 24" DEEP. EQUIP WITH EXTENSION FOR DEEPER ROUTING OF CONDUITS. EQUIP WITH A CVOER
AutoCAD SHX Text
QUAZITE
AutoCAD SHX Text
SEE SPECS
AutoCAD SHX Text VERTICAL ORGANIZER FOR MOUNTING TO THE SIDE OF A RACK. WHERE THE RACK IS LESS THAN 7', CUT OFF VERTICAL ORGANIZER TO FIT RACK.
AutoCAD SHX Text
RLX
AutoCAD SHX Text
3326-BJ06
AutoCAD SHX Text
ADJUSTABLE SHELF FOR 4-POST RACK. ADJUSTABLE TO ATTACH TO ALL 4 POSTS
AutoCAD SHX Text
MIDDLE ATLANTIC
AutoCAD SHX Text
VSA-2744
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text H
AutoCAD SHX Text J
AutoCAD SHX Text K
AutoCAD SHX Text L
AutoCAD SHX Text M
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text P
AutoCAD SHX Text Q
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text V
AutoCAD SHX Text W
AutoCAD SHX Text X
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text index no.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text sheet title
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
WI-FI CABLING INFRASTRUCTURE
AutoCAD SHX Text
ALGER CORRECTIONAL FACILITY
AutoCAD SHX Text
MUNISING, MICHIGAN
AutoCAD SHX Text 12/16/24
AutoCAD SHX Text
ISSUED FOR BID
AutoCAD SHX Text 472ElectronicComm
AutoCAD SHX Text 1065_43
AutoCAD SHX Text Y17084
AutoCAD SHX Text
472/17032.RWG
TC702
WIRELESS CABLE
DROP OR OPEN CEILING, NO ENCLOSURE
N
TC702
CONNECTIVITY CODE
MOHAWK NOTE4
TC702
WIRELESS CABLE. HARD, ACCESSIBLE
CEILING, RECESSED CABLE BOX
TC702
WIRELESS CABLE. DROP CEILING
INSTALL INSIDE ENCLOSURE
TC702
WIRELESS CABLE. HARD CEILING
CONDUIT TO ENCLOSURE
TC702
WIRELESS CABLE. EXTERIOR WAP
VERTICAL MOUNT. STANDARD CABLE
TC702
WIRELESS CABLE, -OPEN CEILING
WALL MOUNTED IN ENCLOSURE
TC702
WIRELESS CABLE. DROP OR
OPEN CEILNG, UNDERGROUND CABLE
TC702
WIRELESS CABLE. EXTERIOR WAP
VERTICAL MOUNT. OUTDOOR CABLE TC702
CABLING DETAILS
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
L A
TC
H
, R A
, N C
A R
B , D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
C om m te ch
D es ig n
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 SURFACE BOX HUBBELL HSB1OW SURFACE BOX HUBBELL HSB1OW HUBBELL HSB1OW HSB1OW 1 CAT-6A CABLE-YELLOW MOHAWK M59230 CAT-6A CABLE-YELLOW MOHAWK M59230 MOHAWK M59230 M59230 1 CAT-6A COBRA CONNECTOR HUBBELL HJU6AY CAT-6A COBRA CONNECTOR HUBBELL HJU6AY HUBBELL HJU6AY HJU6AY 1 CAT-6A PATCH CABLE HUBBELL HC6AY07CAT-6A PATCH CABLE HUBBELL HC6AY07HUBBELL HC6AY07HC6AY07
AutoCAD SHX Text INSTALLATION NOTES: 1. PROVIDE A COIL OF CABLE AT TERMINATION LOCATION. PROVIDE A COIL OF CABLE AT TERMINATION LOCATION. 2. PROVDE A 6' CAT-6A PATCH CABLE. CONNECT TO CABLE JACK. PROVDE A 6' CAT-6A PATCH CABLE. CONNECT TO CABLE JACK. 3. OWNER WILL PROVIDE WAPS TO THE CONTRACTOR. INSTALL WAP OWNER WILL PROVIDE WAPS TO THE CONTRACTOR. INSTALL WAP AND DOCUMENT WAP ADDRESS AND NUMBER ON AS-BUILTS. 4. LABEL PATCH PANEL WITH WAP #LABEL PATCH PANEL WITH WAP #
AutoCAD SHX Text
%%UDROP CEILING INSTALLATION
AutoCAD SHX Text
%%UOPEN CEILING INSTALLATION
AutoCAD SHX Text
15' COIL OF CABLE
AutoCAD SHX Text
SURFACE BOX
AutoCAD SHX Text
INSTALL YELLOW STICKER DOT ON CEILING GRID
AutoCAD SHX Text
15' COIL OF CABLE
AutoCAD SHX Text
SURFACE BOX
AutoCAD SHX Text
CAT-6A PATCH CABLE-YELLOW
AutoCAD SHX Text
WIRELESS ACCESS POINT, CAT-6A NO ENCLOSURE
AutoCAD SHX Text INSTALLATION NOTES: 1. REFER TO THESE NOTES FOR ALL CONNECTIVITY CODES. REFER TO THESE NOTES FOR ALL CONNECTIVITY CODES. FOR SPECIALIZED NOTES SEE THE ACTUAL CONNECTIVITY CODE. 2. ROUTE ALL USER CABLES FROM THE RACK OR CABINET, ROUTE ALL USER CABLES FROM THE RACK OR CABINET, THROUGH THE CABLE TRAY IF SO PROVIDED. IF NO CABLE TRAY IS SHOWN INSTALL CABLES THROUGH "J" HOOKS. PROVIDE ALL "J" HOOKS. 3. CABLES SHALL BE SUPPORTED NO LESS THAN EVERY 5 CABLES SHALL BE SUPPORTED NO LESS THAN EVERY 5 FEET. 4. PROVIDE A SMALL LOOP OF CABLE ABOVE THE CEILING PROVIDE A SMALL LOOP OF CABLE ABOVE THE CEILING PRIOR TO INSTALLING THE CABLE INTO THE USER CONDUIT OR RACEWAY. 5. ROUTE THE CABLE THROUGH THE CONDUIT OR RACEWAY ROUTE THE CABLE THROUGH THE CONDUIT OR RACEWAY AND TO THE WALLBOX, FLOORBOX OR SURFACE MOUNT BOX. PROVIDE ENOUGH EXTRA CABLE FOR TERMINATION AND MAINTENANCE. 6. TERMINATE ALL CABLES WITH THE CORRECT TERMINATE ALL CABLES WITH THE CORRECT CONNECTORS. 7. ALL CONNECTORS SHALL BE INSERTED INTO THE ALL CONNECTORS SHALL BE INSERTED INTO THE KEYSTONE PLATES AND THEN THE KEYSTONE PLATES SHALL BE INSTALLED INTO THE FACEPLATES. 8. INSTALL FACEPLATES TO THE BOXES OR DIRECTLY TO INSTALL FACEPLATES TO THE BOXES OR DIRECTLY TO THE WALL OR FURNITURE IN THE CASE OF SURFACE MOUNT BOXES. 9. EACH CABLE SHALL HAVE A LASER-PRINTED, EACH CABLE SHALL HAVE A LASER-PRINTED, SELF-LAMINATING WRAP-AROUND LABEL AT EACH END. 10. OUTLETS SHALL BE AT 18" AFF UNLESS NOTED ON THE OUTLETS SHALL BE AT 18" AFF UNLESS NOTED ON THE CONNECTIVITY CODE OR PLAN DRAWINGS. 11. LABEL EACH FACEPLATE WITH A LASER-PRINTED LABEL LABEL EACH FACEPLATE WITH A LASER-PRINTED LABEL THAT IS INSTALLED BEHIND THE CLEAR PLASTIC LABEL STRIP. WHERE NO LABEL STRIP IS PROVIDED, THE CONTRACTOR SHALL INSTALL A LASER PRINTED ADHESIVE LABEL. WHERE SPECIFICALLY NOTED, THE CONTRACTOR SHALL INSTALL ENGRAVED LAMACOID LABELS. 12. AFTER INSTALLATION, ALL CABLES SHALL BE TESTED. AFTER INSTALLATION, ALL CABLES SHALL BE TESTED. SEE SPECIFICATIONS FOR TESTING REQUIREMENTS. 13. FOR AUDIO AND VIDEO CONNECTIONS, THE CONTRACTOR FOR AUDIO AND VIDEO CONNECTIONS, THE CONTRACTOR SHALL ROUTE SIGNALS ACROSS THE CABLES FOR TESTING. 14. PROVIDE FLEXIBLE CONDUIT FROM THE WALLBOX OR PROVIDE FLEXIBLE CONDUIT FROM THE WALLBOX OR FLOORBOX TO THE FURNITURE RACEWAY WHERE CABLES ARE INSTALLED IN FURNITURE.
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 SINGLE-GANG OLD WORK RECESSED ARLINGTON DVFR1W SINGLE-GANG OLD WORK RECESSED ARLINGTON DVFR1W ARLINGTON DVFR1W DVFR1W 1 CAT-6A CABLES-YELLOW MOHAWK M59230 CAT-6A CABLES-YELLOW MOHAWK M59230 MOHAWK M59230 M59230 1 CAT-6A JACK-YELLOW HUBBELL HJU6AY CAT-6A JACK-YELLOW HUBBELL HJU6AY HUBBELL HJU6AY HJU6AY 1 DECORA FRAME 1 PORT WHITE HUBBELL NS611W DECORA FRAME 1 PORT WHITE HUBBELL NS611W HUBBELL NS611W NS611W 1 DECORA FACEPLATE HUBBELL P26W DECORA FACEPLATE HUBBELL P26W HUBBELL P26W P26W 1 CAT-6A PATCH CABLE-THIN HUBBELL HCL6AY01 CAT-6A PATCH CABLE-THIN HUBBELL HCL6AY01 HUBBELL HCL6AY01 HCL6AY01
AutoCAD SHX Text INSTALLATION NOTES: 1. CUT INTO DRYWALL OR DROP CEILING AND INSTALL AN OLD-WORK CUT INTO DRYWALL OR DROP CEILING AND INSTALL AN OLD-WORK RECESSED FRAME. INSTALL CAT-6A JACK IN THE SURFACE MOUNT BOX. 2. PROVIDE A COIL OF CABLE ABOVE CEILING. ROUTE CABLE INTO PROVIDE A COIL OF CABLE ABOVE CEILING. ROUTE CABLE INTO RECESSED BOX. TERMINATE THE CABLE WITH CAT6A JACK INTO FACEPLATE. 3. INSTALL WAP MOUNTING PLATE OVER RECESSED FRAME. INSTALL INSTALL WAP MOUNTING PLATE OVER RECESSED FRAME. INSTALL CAT6A PATCH CABLE THROUGH WAP MOUNTING PLATE AND PLUG INTO THE WAP. 4. OWNER WILL PROVIDE WAPS TO THE CONTRACTOR. INSTALL WAP OWNER WILL PROVIDE WAPS TO THE CONTRACTOR. INSTALL WAP AND DOCUMENT WAP ADDRESS AND NUMBER ON AS-BUILTS. 5. LABEL PATCH PANEL WITH WAP #LABEL PATCH PANEL WITH WAP #
AutoCAD SHX Text
WIRELESS ACCESS POINT, CAT-6A HARD CEILING -NO ENCLOSURE
AutoCAD SHX Text
%%UHARD CEILING INSTALLATION
AutoCAD SHX Text
15' COIL OF CABLE
AutoCAD SHX Text
CAT6A JACK
AutoCAD SHX Text
WAP
AutoCAD SHX Text
CUT IN AN OLD-WORK RECESSED BACKBOX
AutoCAD SHX Text
DECORA FACEPLATE
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 SURFACE BOX HUBBELL HSB1OW SURFACE BOX HUBBELL HSB1OW HUBBELL HSB1OW HSB1OW 1 CAT-6A CABLE-YELLOW MOHAWK M59230 CAT-6A CABLE-YELLOW MOHAWK M59230 MOHAWK M59230 M59230 1 CAT-6A COBRA CONNECTOR HUBBELL HJU6AY CAT-6A COBRA CONNECTOR HUBBELL HJU6AY HUBBELL HJU6AY HJU6AY 1 CAT-6A PATCH CABLE HUBBELL HC6AY07CAT-6A PATCH CABLE HUBBELL HC6AY07HUBBELL HC6AY07HC6AY07
AutoCAD SHX Text INSTALLATION NOTES: 1. PROVIDE A COIL OF CABLE AT TERMINATION LOCATION. PROVIDE A COIL OF CABLE AT TERMINATION LOCATION. 2. PROVIDE A 6' CAT-6A PATCH CABLE. CONNECT TO CABLE JACK. PROVIDE A 6' CAT-6A PATCH CABLE. CONNECT TO CABLE JACK. 3. OWNER WILL PROVIDE WAP AND OBERON DROP CEILING BOX TO OWNER WILL PROVIDE WAP AND OBERON DROP CEILING BOX TO THE CONTRACTOR. INSTALL WAP AND ENCLOSURE AND DOCUMENT WAP ADDRESS AND NUMBER ON AS-BUILTS. 4. DISPOSE OF EXISTING CEILING TILE. CUT 2'X4' TILES WHERE DISPOSE OF EXISTING CEILING TILE. CUT 2'X4' TILES WHERE REQUIRED. 5. LABEL PATCH PANEL WITH WAP #LABEL PATCH PANEL WITH WAP #
AutoCAD SHX Text
%%UDROP CEILING INSTALLATION
AutoCAD SHX Text
15' COIL OF CABLE
AutoCAD SHX Text
SURFACE BOX
AutoCAD SHX Text INSTALL OWNER PROVIDED OBERON BOX #1047-COAP9120-LW. CUT TILE IF IT IS 24"X48" CEILING TILE
AutoCAD SHX Text
WIRELESS ACCESS POINT, CAT-6A DROP CEILING ENCLOSURE
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 CAT-6A CABLE-YELLOW MOHAWK M59230 CAT-6A CABLE-YELLOW MOHAWK M59230 MOHAWK M59230 M59230 1 CAT-6A COBRA CONNECTOR HUBBELL HJU6AY CAT-6A COBRA CONNECTOR HUBBELL HJU6AY HUBBELL HJU6AY HJU6AY 1 CAT-6A PATCH CABLE-THIN HUBBELL HCL6AY01 CAT-6A PATCH CABLE-THIN HUBBELL HCL6AY01 HUBBELL HCL6AY01 HCL6AY01
AutoCAD SHX Text INSTALLATION NOTES: 1. PROVIDE A SHORT COIL OF CABLE AT TERMINATION LOCATION PROVIDE A SHORT COIL OF CABLE AT TERMINATION LOCATION INSIDE ENCLOSURE 2. PROVIDE A 6" or 12" CAT-6A PATCH CABLE. CONNECT TO CABLE PROVIDE A 6" or 12" CAT-6A PATCH CABLE. CONNECT TO CABLE JACK. 3. OWNER WILL PROVIDE WAPS AND WAP ENCLOSURE TO THE OWNER WILL PROVIDE WAPS AND WAP ENCLOSURE TO THE CONTRACTOR. INSTALL WAP AND DOCUMENT WAP ADDRESS AND NUMBER ON AS-BUILTS. 4. LABEL PATCH PANEL WITH WAP # LABEL PATCH PANEL WITH WAP # 5. EXTEND CONDUIT DIRECTLY TO THE WAP ENCLOSURE. CONNECT EXTEND CONDUIT DIRECTLY TO THE WAP ENCLOSURE. CONNECT WITH CONDUIT CONNECTIONS.
AutoCAD SHX Text
WIRELESS ACCESS POINT, CAT-6A SURFACE ENCLOSURE RACEWAY REQUIRED
AutoCAD SHX Text
%%UHARD DRYWALL CEILING INSTALLATION
AutoCAD SHX Text
INSTALL CAT-6A PATCH CABLE AND WAP
AutoCAD SHX Text
INSTALL 3/4" OR 1" CONDUIT
AutoCAD SHX Text
%%UHARD IN-ACCESSIBLE CEILING INSTALLATION
AutoCAD SHX Text
INSTALL 3/4" OR 1" CONDUIT
AutoCAD SHX Text
INSTALL OWNER PROVIDED WAP ENCLOSURE. OBERON #1020
AutoCAD SHX Text
INSTALL CAT-6A PATCH CABLE AND WAP
AutoCAD SHX Text
INSTALL OWNER PROVIDED WAP ENCLOSURE. OBERON #1020
AutoCAD SHX Text
CAT-6A PATCH CABLE-YELLOW
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 CAT-6A CABLE-YELLOW MOHAWK M59230 CAT-6A CABLE-YELLOW MOHAWK M59230 MOHAWK M59230 M59230 1 CAT-6A COBRA COUPLER HUBBELL SC6A CAT-6A COBRA COUPLER HUBBELL SC6A HUBBELL SC6A SC6A 1 EXTERIOR RATED CAT-6A CABLE MOHAWK M59199 EXTERIOR RATED CAT-6A CABLE MOHAWK M59199 MOHAWK M59199 M59199 1 CABLE GLAND AT WAP CISCO PROVIDED BY OWNER CABLE GLAND AT WAP CISCO PROVIDED BY OWNER CISCO PROVIDED BY OWNER PROVIDED BY OWNER
AutoCAD SHX Text INSTALLATION NOTES: 1. INSTALL RACEWAY THRU THE WALL TO ACCESSIBLE CEILING AREA. SEAL AROUND CONDUIT AND BOX. INSTALL RACEWAY THRU THE WALL TO ACCESSIBLE CEILING AREA. SEAL AROUND CONDUIT AND BOX. 2. ISNTALL TWO-GANG BOX ON EXTERIOR OF THE BUILDING. PROVIDE WEATHERPROOF COVER ON THE BOX. ISNTALL TWO-GANG BOX ON EXTERIOR OF THE BUILDING. PROVIDE WEATHERPROOF COVER ON THE BOX. 3. INSTALL CABLE GLAND AT BOTTOM OF THE TWO-GANG BOX TO PROVIDE WEATHERPROOF TRANSITION FROM INSTALL CABLE GLAND AT BOTTOM OF THE TWO-GANG BOX TO PROVIDE WEATHERPROOF TRANSITION FROM BACKBOX TO CABLE OUTSIDE BOX. INSTALL EXTERIOR RATED CAT-6A CABLE FROM BACKBOX TO WAP. 4. TERMINATE EXTERIOR RATED CABLE ONTO THE CISCO CABLE GLAND. PLUG CABLE INTO THE WAP. TERMINATE EXTERIOR RATED CABLE ONTO THE CISCO CABLE GLAND. PLUG CABLE INTO THE WAP. 5. LABEL PATCH PANEL WITH WAP #LABEL PATCH PANEL WITH WAP #
AutoCAD SHX Text
WIRELESS ACCESS POINT, CAT-6A MOUNTED TO EXTERIOR
AutoCAD SHX Text
3/4" CONDUIT
AutoCAD SHX Text
3/4" CONDUIT
AutoCAD SHX Text
EXTERIOR WAP INSTALLATION DROP OR OPEN/ACCESSIBLE CEILING
AutoCAD SHX Text
EXTERIOR WAP INSTALLATION WHERE INTERIOR REQUIRES CONDUIT
AutoCAD SHX Text
UNISTRUT AND CONDUIT STRAP. TORX SCREWS REQUIRED
AutoCAD SHX Text
SINGLE GANG BACKBOX WITH COVER
AutoCAD SHX Text
INSTALL WAP AND SECURE TO BUILDING
AutoCAD SHX Text
OUTDOOR RATED CAT-6A CABLE
AutoCAD SHX Text
XXX-YYY-ZZZ
AutoCAD SHX Text
EXTERIOR RATED CAT-6A CABLE
AutoCAD SHX Text
EXTERIOR WAP INSTALLATION FRONT VIEW
AutoCAD SHX Text
DOUBLE-GANG BACKBOX WITH RUBBER GROMMET AND SEALED COVER
AutoCAD SHX Text
CABLE GLAND
AutoCAD SHX Text
INSTALL WAP AND SECURE TO BUILDING
AutoCAD SHX Text
OUTDOOR RATED CAT-6A CABLE
AutoCAD SHX Text
DOUBLE-GANG BACKBOX WITH RUBBER GROMMET AND SEALED COVER
AutoCAD SHX Text
RJ-45 CABLE GLAND-OWNER PROVIDED
AutoCAD SHX Text
INSTALL TWO-HOLE CABLE STRAP TO SECURE PATCH CABLE
AutoCAD SHX Text
DOUBLE-GANG BACKBOX WITH RUBBER GROMMET AND SEALED COVER
AutoCAD SHX Text
CAT-6A COUPLER
AutoCAD SHX Text
CAT-6A COUPLER
AutoCAD SHX Text
%%UCAT-6A COUPLER
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CAT-6A CONNECTOR
AutoCAD SHX Text
SURFACE MOUNT BOX
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
CAT-6A CONNECTOR
AutoCAD SHX Text
SURFACE MOUNT BOX
AutoCAD SHX Text
CAT-6A CONNECTOR
AutoCAD SHX Text
AutoCAD SHX Text
CAT-6A CABLE TO RACK
AutoCAD SHX Text
CAT-6A PATCH CABLE-YELLOW
AutoCAD SHX Text
WAP
AutoCAD SHX Text
CABLE GLAND
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 SURFACE BOX HUBBELL HSB1OW SURFACE BOX HUBBELL HSB1OW HUBBELL HSB1OW HSB1OW 1 CAT-6A CABLE-YELLOW MOHAWK M59230 CAT-6A CABLE-YELLOW MOHAWK M59230 MOHAWK M59230 M59230 1 CAT-6A COBRA CONNECTOR HUBBELL HJU6AY CAT-6A COBRA CONNECTOR HUBBELL HJU6AY HUBBELL HJU6AY HJU6AY 1 CAT-6A PATCH CABLE-THIN HUBBELL HCL6AY01 CAT-6A PATCH CABLE-THIN HUBBELL HCL6AY01 HUBBELL HCL6AY01 HCL6AY01
AutoCAD SHX Text INSTALLATION NOTES: 1. PROVIDE A SHORT COIL OF CABLE AT TERMINATION LOCATION. PROVIDE A SHORT COIL OF CABLE AT TERMINATION LOCATION. 2. PROVIDE A 6" TO 12" CAT-6A PATCH CABLE. CONNECT TO CABLE PROVIDE A 6" TO 12" CAT-6A PATCH CABLE. CONNECT TO CABLE JACK. 3. OWNER WILL PROVIDE WAPS AND WAP ENCLOSURE TO THE OWNER WILL PROVIDE WAPS AND WAP ENCLOSURE TO THE CONTRACTOR. INSTALL WAP AND DOCUMENT WAP ADDRESS AND NUMBER ON AS-BUILTS. 4. LABEL PATCH PANEL WITH WAP # LABEL PATCH PANEL WITH WAP # 5. EXTEND CONDUIT DIRECTLY TO THE WAP ENCLOSURE. CONNECT EXTEND CONDUIT DIRECTLY TO THE WAP ENCLOSURE. CONNECT WITH CONDUIT CONNECTIONS.
AutoCAD SHX Text
WIRELESS ACCESS POINT, CAT-6A SURFACE ENCLOSURE RACEWAY REQUIRED
AutoCAD SHX Text
CAT-6A CONNECTOR
AutoCAD SHX Text
AutoCAD SHX Text
CAT-6A CABLE TO RACK
AutoCAD SHX Text
CAT-6A PATCH CABLE
AutoCAD SHX Text
CAT-6A CONNECTOR
AutoCAD SHX Text
3/4" CONDUIT
AutoCAD SHX Text
FRONT VIEW
AutoCAD SHX Text
WAP
AutoCAD SHX Text
WALL MOUNT WAP ENCLOSURE. -PROVIDED BY OWNER
AutoCAD SHX Text
MOUNT BETWEEN 10' AND 16' AFF. VERIFY ONSITE
AutoCAD SHX Text
SIDE VIEW
AutoCAD SHX Text
3/4" CONDUIT
AutoCAD SHX Text
WALL MOUNT WAP ENCLOSURE. -PROVIDED BY OWNER
AutoCAD SHX Text
CAT-6A PATCH CABLE-YELLOW
AutoCAD SHX Text
WAP
AutoCAD SHX Text
WAP
AutoCAD SHX Text
WAP
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
SURFACE MOUNT BOX
AutoCAD SHX Text
CAT-6A CABLE TO RACK
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 CAT-6A CABLE-UNDERGROUND MOHAWK M59199 CAT-6A CABLE-UNDERGROUND MOHAWK M59199 MOHAWK M59199 M59199 1 CAT-6A COBRA COUPLER HUBBELL SC6A CAT-6A COBRA COUPLER HUBBELL SC6A HUBBELL SC6A SC6A 1 CAT-6 CABLE-UNDERGROUND -STANDARD DISTANCE CAT-6 CABLE-UNDERGROUND -STANDARD DISTANCE MOHAWK M59199 M59199 1 CABLE GLAND AT WAP CISCO PROVIDED BY OWNER CABLE GLAND AT WAP CISCO PROVIDED BY OWNER CISCO PROVIDED BY OWNER PROVIDED BY OWNER
AutoCAD SHX Text INSTALLATION NOTES: 1. INSTALL RACEWAY THRU THE WALL TO ACCESSIBLE CEILING AREA. SEAL AROUND CONDUIT AND BOX. INSTALL RACEWAY THRU THE WALL TO ACCESSIBLE CEILING AREA. SEAL AROUND CONDUIT AND BOX. 2. ISNTALL TWO-GANG BOX ON EXTERIOR OF THE BUILDING. PROVIDE WEATHERPROOF COVER ON THE BOX. ISNTALL TWO-GANG BOX ON EXTERIOR OF THE BUILDING. PROVIDE WEATHERPROOF COVER ON THE BOX. 3. INSTALL CABLE GLAND AT BOTTOM OF THE TWO-GANG BOX TO PROVIDE WEATHERPROOF TRANSITION FROM INSTALL CABLE GLAND AT BOTTOM OF THE TWO-GANG BOX TO PROVIDE WEATHERPROOF TRANSITION FROM BACKBOX TO CABLE OUTSIDE BOX. INSTALL EXTERIOR RATED CAT-6A CABLE FROM BACKBOX TO WAP. 4. TERMINATE EXTERIOR RATED CABLE ONTO THE CISCO CABLE GLAND. PLUG CABLE INTO THE WAP. TERMINATE EXTERIOR RATED CABLE ONTO THE CISCO CABLE GLAND. PLUG CABLE INTO THE WAP. 5. LABEL PATCH PANEL WITH WAP #LABEL PATCH PANEL WITH WAP #
AutoCAD SHX Text
WIRELESS ACCESS POINT, CAT-6A MOUNTED TO EXTERIOR
AutoCAD SHX Text
3/4" CONDUIT
AutoCAD SHX Text
3/4" CONDUIT
AutoCAD SHX Text
EXTERIOR WAP INSTALLATION DROP OR OPEN/ACCESSIBLE CEILING
AutoCAD SHX Text
EXTERIOR WAP INSTALLATION WHERE INTERIOR REQUIRES CONDUIT
AutoCAD SHX Text
UNISTRUT AND CONDUIT STRAP. TORX SCREWS REQUIRED
AutoCAD SHX Text
SINGLE GANG BACKBOX WITH COVER
AutoCAD SHX Text
INSTALL WAP AND SECURE TO BUILDING
AutoCAD SHX Text
OUTDOOR RATED CAT-6A CABLE
AutoCAD SHX Text
XXX-YYY-ZZZ
AutoCAD SHX Text
EXTERIOR RATED CAT-6A CABLE
AutoCAD SHX Text
EXTERIOR WAP INSTALLATION FRONT VIEW
AutoCAD SHX Text
DOUBLE-GANG BACKBOX WITH RUBBER GROMMET AND SEALED COVER
AutoCAD SHX Text
CABLE GLAND
AutoCAD SHX Text
INSTALL WAP AND SECURE TO BUILDING
AutoCAD SHX Text
OUTDOOR RATED CAT-6A CABLE
AutoCAD SHX Text
DOUBLE-GANG BACKBOX WITH RUBBER GROMMET AND SEALED COVER
AutoCAD SHX Text
RJ-45 CABLE GLAND
AutoCAD SHX Text
INSTALL TWO-HOLE CABLE STRAP TO SECURE PATCH CABLE
AutoCAD SHX Text
DOUBLE-GANG BACKBOX WITH RUBBER GROMMET AND SEALED COVER
AutoCAD SHX Text
CAT-6A COUPLER
AutoCAD SHX Text
CAT-6A COUPLER
AutoCAD SHX Text
%%UCAT-6A COUPLER
AutoCAD SHX Text
CABLE GLAND
AutoCAD SHX Text
AutoCAD SHX Text
WAP
AutoCAD SHX Text
CAT-6A CABLE TO RACK
AutoCAD SHX Text
CONDUIT TO OTHER BUILDING. SEE SITE PLAN
AutoCAD SHX Text
CONDUIT TO OTHER BUILDING. SEE SITE PLAN
AutoCAD SHX Text
%%UDROP CEILING INSTALLATION
AutoCAD SHX Text
%%UOPEN CEILING INSTALLATION
AutoCAD SHX Text
15' COIL OF CABLE
AutoCAD SHX Text
SURFACE BOX
AutoCAD SHX Text
INSTALL YELLOW STICKER DOT ON CEILING GRID
AutoCAD SHX Text
15' COIL OF CABLE
AutoCAD SHX Text
SURFACE BOX
AutoCAD SHX Text
INSTALL CAT-6A PATCH CABLE AND WAP
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 CAT-6A CABLE-UNDERGROUND MOHAWK M59198 CAT-6A CABLE-UNDERGROUND MOHAWK M59198 MOHAWK M59198 M59198 1 SURFACE BOX HUBBELL HSB1OW SURFACE BOX HUBBELL HSB1OW HUBBELL HSB1OW HSB1OW 1 CAT-6A COBRA CONNECTOR HUBBELL HJU6AY CAT-6A COBRA CONNECTOR HUBBELL HJU6AY HUBBELL HJU6AY HJU6AY 1 CAT-6A PATCH CABLE HUBBELL HC6AY07 CAT-6A PATCH CABLE HUBBELL HC6AY07 HUBBELL HC6AY07 HC6AY07
AutoCAD SHX Text
WIRELESS ACCESS POINT, CAT-6A UNDERGROUND CABLE. INTERIOR WAP
AutoCAD SHX Text
%%UCAT-6A COUPLER
AutoCAD SHX Text
AutoCAD SHX Text
CONDUIT TO OTHER BUILDING. SEE SITE PLAN
AutoCAD SHX Text
CONDUIT TO OTHER BUILDING. SEE SITE PLAN
AutoCAD SHX Text
15' COIL OF CABLE
AutoCAD SHX Text
SURFACE BOX
AutoCAD SHX Text INSTALL OWNER PROVIDED OBERON BOX #1047-COAP9120-LW. CUT TILE IF IT IS 24"X48" CEILING TILE
AutoCAD SHX Text
CAT-6A PATCH CABLE-YELLOW
AutoCAD SHX Text
CONDUIT TO OTHER BUILDING. SEE SITE PLAN
AutoCAD SHX Text INSTALLATION NOTES: 1. INSTALL RACEWAY THRU THE WALL TO ACCESSIBLE INSTALL RACEWAY THRU THE WALL TO ACCESSIBLE CEILING AREA. SEAL AROUND CONDUIT AND BOX. 2. ROUTE EXTERIOR CONDUIT TO BUILDING OR CABINET ROUTE EXTERIOR CONDUIT TO BUILDING OR CABINET NOTED ON THE DESIGN DRAWINGS. 3. INSTALL LIGHTNING ARRESTOR ON CABLE AT INSTALL LIGHTNING ARRESTOR ON CABLE AT BUILDING OR CABINET. 4. INSTALL WAP. TERMINATE CABLE. INSTALL PATCH INSTALL WAP. TERMINATE CABLE. INSTALL PATCH CABLE AND INSTALL WAP. TEST CONNECTTIVITY 5. LABEL PATCH PANEL WITH WAP # LABEL PATCH PANEL WITH WAP # 6. SEE SPREADSHEET FOR MOUNTING TYPESEE SPREADSHEET FOR MOUNTING TYPE
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text index no.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text sheet title
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
WI-FI CABLING INFRASTRUCTURE
AutoCAD SHX Text
ALGER CORRECTIONAL FACILITY
AutoCAD SHX Text
MUNISING, MICHIGAN
AutoCAD SHX Text 12/16/24
AutoCAD SHX Text
ISSUED FOR BID
AutoCAD SHX Text 472ElectronicComm
AutoCAD SHX Text 1065_43
AutoCAD SHX Text Y17084
TC703
EXTERIOR WAP. VERTCIAL MOUNT
UNDERGROUND CABLE, LONG DISTANCE
TC703
EXTERIOR WAP. HORIZONTAL MOUNT
STANDARD CABLE3
TC703
EXTERIOR WAP. HORIZONTAL MOUNT
UNDERGROUND CABLE
TC703
EXTERIOR WAP -POLE MOUNTED
UNDERGROUND CABLE TC703
CABLING DETAILS
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
L A
TC
H
, R A
, N C
A R
B , D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
C om m te ch
D es ig n
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 CAT-6A CABLE-UNDERGROUND, LONG-DISTANCE TO 650' CAT-6A CABLE-UNDERGROUND, LONG-DISTANCE TO 650' SUPERIOR ESSEX PW-04-401-58 PW-04-401-58 1 CAT-6A COBRA COUPLER HUBBELL SC6A CAT-6A COBRA COUPLER HUBBELL SC6A HUBBELL SC6A SC6A 1 CAT-6 CABLE-UNDERGROUND -STANDARD DISTANCE CAT-6 CABLE-UNDERGROUND -STANDARD DISTANCE MOHAWK M59199 M59199 1 CABLE GLAND AT WAP CISCO PROVIDED BY OWNER CABLE GLAND AT WAP CISCO PROVIDED BY OWNER CISCO PROVIDED BY OWNER PROVIDED BY OWNER
AutoCAD SHX Text INSTALLATION NOTES: 1. INSTALL RACEWAY THRU THE WALL TO ACCESSIBLE CEILING AREA. SEAL AROUND CONDUIT AND BOX. INSTALL RACEWAY THRU THE WALL TO ACCESSIBLE CEILING AREA. SEAL AROUND CONDUIT AND BOX. 2. INSTALL TWO-GANG BOX ON EXTERIOR OF THE BUILDING. PROVIDE WEATHERPROOF COVER ON THE BOX. INSTALL TWO-GANG BOX ON EXTERIOR OF THE BUILDING. PROVIDE WEATHERPROOF COVER ON THE BOX. 3. INSTALL CABLE GLAND AT BOTTOM OF THE TWO-GANG BOX TO PROVIDE WEATHERPROOF TRANSITION FROM INSTALL CABLE GLAND AT BOTTOM OF THE TWO-GANG BOX TO PROVIDE WEATHERPROOF TRANSITION FROM BACKBOX TO CABLE OUTSIDE BOX. INSTALL EXTERIOR RATED CAT-6A CABLE FROM BACKBOX TO WAP. 4. TERMINATE EXTERIOR RATED CABLE ONTO THE CISCO CABLE GLAND. PLUG CABLE INTO THE WAP. TERMINATE EXTERIOR RATED CABLE ONTO THE CISCO CABLE GLAND. PLUG CABLE INTO THE WAP. 5. LABEL PATCH PANEL WITH WAP #LABEL PATCH PANEL WITH WAP #
AutoCAD SHX Text
WIRELESS ACCESS POINT, CAT-6A MOUNTED TO EXTERIOR
AutoCAD SHX Text
3/4" CONDUIT
AutoCAD SHX Text
3/4" CONDUIT
AutoCAD SHX Text
EXTERIOR WAP INSTALLATION DROP OR OPEN/ACCESSIBLE CEILING
AutoCAD SHX Text
EXTERIOR WAP INSTALLATION WHERE INTERIOR REQUIRES CONDUIT
AutoCAD SHX Text
UNISTRUT AND CONDUIT STRAP. TORX SCREWS REQUIRED
AutoCAD SHX Text
SINGLE GANG BACKBOX WITH COVER
AutoCAD SHX Text
INSTALL WAP AND SECURE TO BUILDING
AutoCAD SHX Text
OUTDOOR RATED CAT-6A CABLE
AutoCAD SHX Text
XXX-YYY-ZZZ
AutoCAD SHX Text
EXTERIOR RATED CAT-6A CABLE
AutoCAD SHX Text
EXTERIOR WAP INSTALLATION FRONT VIEW
AutoCAD SHX Text
DOUBLE-GANG BACKBOX WITH RUBBER GROMMET AND SEALED COVER
AutoCAD SHX Text
CABLE GLAND
AutoCAD SHX Text
RJ-45 CABLE GLAND
AutoCAD SHX Text
INSTALL TWO-HOLE CABLE STRAP TO SECURE PATCH CABLE
AutoCAD SHX Text
DOUBLE-GANG BACKBOX WITH RUBBER GROMMET AND SEALED COVER
AutoCAD SHX Text
CAT-6A COUPLER
AutoCAD SHX Text
%%UCAT-6A COUPLER
AutoCAD SHX Text
AutoCAD SHX Text
WAP
AutoCAD SHX Text
CAT-6A CABLE UNDERGROUND TO CABINET OR RACK. SEE FLOORPLANS
AutoCAD SHX Text
CONDUIT TO OTHER BUILDING. SEE SITE PLAN
AutoCAD SHX Text
CONDUIT TO OTHER BUILDING. SEE SITE PLAN
AutoCAD SHX Text
3/4" CONDUIT
AutoCAD SHX Text
INSTALL WAP AND SECURE TO BUILDING
AutoCAD SHX Text
OUTDOOR RATED CAT-6A CABLE
AutoCAD SHX Text
DOUBLE-GANG BACKBOX WITH RUBBER GROMMET AND SEALED COVER
AutoCAD SHX Text
CABLE GLAND
AutoCAD SHX Text
CAT-6A COUPLER
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 CAT-6A CABLE-YELLOW MOHAWK M59230 CAT-6A CABLE-YELLOW MOHAWK M59230 MOHAWK M59230 M59230 1 CAT-6A COBRA COUPLER HUBBELL SC6A CAT-6A COBRA COUPLER HUBBELL SC6A HUBBELL SC6A SC6A 1 EXTERIOR RATED CAT-6A CABLE MOHAWK M59199. EXTERIOR RATED CAT-6A CABLE MOHAWK M59199. MOHAWK M59199. M59199. INSTALL THIS CABLE FROM COUPLER TO WAP 1 CABLE GLAND AT WAP CISCO PROVIDED BY OWNER CABLE GLAND AT WAP CISCO PROVIDED BY OWNER CISCO PROVIDED BY OWNER PROVIDED BY OWNER
AutoCAD SHX Text INSTALLATION NOTES: 1. INSTALL RACEWAY THRU THE WALL TO ACCESSIBLE CEILING AREA. SEAL AROUND CONDUIT AND BOX. INSTALL RACEWAY THRU THE WALL TO ACCESSIBLE CEILING AREA. SEAL AROUND CONDUIT AND BOX. 2. INSTALL TWO-GANG BOX ON EXTERIOR OF THE BUILDING. PROVIDE WEATHERPROOF COVER ON THE BOX. INSTALL TWO-GANG BOX ON EXTERIOR OF THE BUILDING. PROVIDE WEATHERPROOF COVER ON THE BOX. 3. INSTALL CABLE GLAND AT BOTTOM OF THE TWO-GANG BOX TO PROVIDE WEATHERPROOF TRANSITION FROM INSTALL CABLE GLAND AT BOTTOM OF THE TWO-GANG BOX TO PROVIDE WEATHERPROOF TRANSITION FROM BACKBOX TO CABLE OUTSIDE BOX. INSTALL EXTERIOR RATED CAT-6A CABLE FROM BACKBOX TO WAP. 4. TERMINATE EXTERIOR RATED CABLE ONTO THE CISCO CABLE GLAND. PLUG CABLE INTO THE WAP. TERMINATE EXTERIOR RATED CABLE ONTO THE CISCO CABLE GLAND. PLUG CABLE INTO THE WAP. 5. CONTRACTOR SHALL PROVIDE AND INSTALL CISCO CABLE GLAND AT WAP TERMINATION.CONTRACTOR SHALL PROVIDE AND INSTALL CISCO CABLE GLAND AT WAP TERMINATION.
AutoCAD SHX Text
WIRELESS ACCESS POINT, CAT-6A MOUNTED TO EXTERIOR
AutoCAD SHX Text
3/4" CONDUIT
AutoCAD SHX Text
3/4" CONDUIT
AutoCAD SHX Text
EXTERIOR WAP INSTALLATION DROP OR OPEN/ACCESSIBLE CEILING
AutoCAD SHX Text
EXTERIOR WAP INSTALLATION WHERE INTERIOR REQUIRES CONDUIT
AutoCAD SHX Text
UNISTRUT AND CONDUIT STRAP. TORX SCREWS REQUIRED
AutoCAD SHX Text
SINGLE GANG BACKBOX WITH COVER
AutoCAD SHX Text
INSTALL WAP AND SECURE TO BUILDING
AutoCAD SHX Text
OUTDOOR RATED CAT-6A CABLE
AutoCAD SHX Text
EXTERIOR RATED CAT-6A CABLE
AutoCAD SHX Text
EXTERIOR WAP INSTALLATION FRONT VIEW
AutoCAD SHX Text
DOUBLE-GANG BACKBOX WITH RUBBER GROMMET AND SEALED COVER
AutoCAD SHX Text
CABLE GLAND
AutoCAD SHX Text
OUTDOOR RATED CAT-6A CABLE
AutoCAD SHX Text
DOUBLE-GANG BACKBOX WITH RUBBER GROMMET AND SEALED COVER
AutoCAD SHX Text
RJ-45 CABLE GLAND
AutoCAD SHX Text
INSTALL TWO-HOLE CABLE STRAP TO SECURE PATCH CABLE
AutoCAD SHX Text
DOUBLE-GANG BACKBOX WITH RUBBER GROMMET AND SEALED COVER
AutoCAD SHX Text
CAT-6A COUPLER
AutoCAD SHX Text
CAT-6A COUPLER
AutoCAD SHX Text
%%UCAT-6A COUPLER
AutoCAD SHX Text
AutoCAD SHX Text
CAT-6A CABLE TO RACK OR CABINET. SEE FLOORPLANS
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 CAT-6A CABLE-UNDERGROUND MOHAWK M59199 CAT-6A CABLE-UNDERGROUND MOHAWK M59199 MOHAWK M59199 M59199 1 CAT-6A COBRA COUPLER HUBBELL SC6A CAT-6A COBRA COUPLER HUBBELL SC6A HUBBELL SC6A SC6A 1 CAT-6 CABLE-UNDERGROUND -STANDARD DISTANCE CAT-6 CABLE-UNDERGROUND -STANDARD DISTANCE MOHAWK M59198 M59198 1 CABLE GLAND AT WAP CISCO PROVIDED BY OWNER CABLE GLAND AT WAP CISCO PROVIDED BY OWNER CISCO PROVIDED BY OWNER PROVIDED BY OWNER
AutoCAD SHX Text INSTALLATION NOTES: 1. INSTALL RACEWAY THRU THE WALL TO ACCESSIBLE CEILING AREA. SEAL AROUND CONDUIT AND BOX. INSTALL RACEWAY THRU THE WALL TO ACCESSIBLE CEILING AREA. SEAL AROUND CONDUIT AND BOX. 2. INSTALL TWO-GANG BOX ON EXTERIOR OF THE BUILDING. PROVIDE WEATHERPROOF COVER ON THE BOX. INSTALL TWO-GANG BOX ON EXTERIOR OF THE BUILDING. PROVIDE WEATHERPROOF COVER ON THE BOX. 3. INSTALL CABLE GLAND AT BOTTOM OF THE TWO-GANG BOX TO PROVIDE WEATHERPROOF TRANSITION FROM INSTALL CABLE GLAND AT BOTTOM OF THE TWO-GANG BOX TO PROVIDE WEATHERPROOF TRANSITION FROM BACKBOX TO CABLE OUTSIDE BOX. INSTALL EXTERIOR RATED CAT-6A CABLE FROM BACKBOX TO WAP. 4. TERMINATE EXTERIOR RATED CABLE ONTO THE CISCO CABLE GLAND. PLUG CABLE INTO THE WAP. TERMINATE EXTERIOR RATED CABLE ONTO THE CISCO CABLE GLAND. PLUG CABLE INTO THE WAP. 5. CONTRACTOR SHALL PROVIDE AND INSTALL CISCO CABLE GLAND AT WAP TERMINATION.CONTRACTOR SHALL PROVIDE AND INSTALL CISCO CABLE GLAND AT WAP TERMINATION.
AutoCAD SHX Text
WIRELESS ACCESS POINT, CAT-6A MOUNTED TO EXTERIOR
AutoCAD SHX Text
3/4" CONDUIT
AutoCAD SHX Text
3/4" CONDUIT
AutoCAD SHX Text
EXTERIOR WAP INSTALLATION DROP OR OPEN/ACCESSIBLE CEILING
AutoCAD SHX Text
EXTERIOR WAP INSTALLATION WHERE INTERIOR REQUIRES CONDUIT
AutoCAD SHX Text
UNISTRUT AND CONDUIT STRAP. TORX SCREWS REQUIRED
AutoCAD SHX Text
SINGLE GANG BACKBOX WITH COVER
AutoCAD SHX Text
DOUBLE-GANG BACKBOX WITH RUBBER GROMMET AND SEALED COVER
AutoCAD SHX Text
DOUBLE-GANG BACKBOX WITH RUBBER GROMMET AND SEALED COVER
AutoCAD SHX Text
CAT-6A COUPLER
AutoCAD SHX Text
CAT-6A COUPLER
AutoCAD SHX Text
%%UCAT-6A COUPLER
AutoCAD SHX Text
AutoCAD SHX Text
CAT-6A CABLE UNDERGROUND TO CABINET OR RACK. SEE FLOORPLANS
AutoCAD SHX Text
CONDUIT TO OTHER BUILDING. SEE SITE PLAN
AutoCAD SHX Text
CONDUIT TO OTHER BUILDING. SEE SITE PLAN
AutoCAD SHX Text
INSTALL WAP AND SECURE TO BUILDING
AutoCAD SHX Text
CABLE GLAND
AutoCAD SHX Text
INSTALL WAP AND SECURE TO BUILDING
AutoCAD SHX Text
OUTDOOR RATED CAT-6A CABLE
AutoCAD SHX Text
CABLE GLAND
AutoCAD SHX Text
INSTALL WAP AND SECURE TO BUILDING
AutoCAD SHX Text
OUTDOOR RATED CAT-6A CABLE
AutoCAD SHX Text
CABLE GLAND
AutoCAD SHX Text
HORIZONTAL MOUNT
AutoCAD SHX Text
HORIZONTAL MOUNT
AutoCAD SHX Text
HORIZONTAL MOUNT
AutoCAD SHX Text
HORIZONTAL MOUNT
AutoCAD SHX Text
WAP
AutoCAD SHX Text
HORIZONTAL MOUNT
AutoCAD SHX Text
EXTERIOR RATED CAT-6A CABLE
AutoCAD SHX Text
EXTERIOR WAP INSTALLATION FRONT VIEW
AutoCAD SHX Text
RJ-45 CABLE GLAND
AutoCAD SHX Text
INSTALL TWO-HOLE CABLE STRAP TO SECURE PATCH CABLE
AutoCAD SHX Text
DOUBLE-GANG BACKBOX WITH RUBBER GROMMET AND SEALED COVER
AutoCAD SHX Text
WAP
AutoCAD SHX Text
HORIZONTAL MOUNT
AutoCAD SHX Text
TYPICAL PERIMETER WAP CONNECTIVITY DIAGRAM
AutoCAD SHX Text
USE EXISTING JUNCTION BOX AT POLE. USED FOR CAMERA CABLE JUNCTION BOX 3
AutoCAD SHX Text
WAP LOCATION AT 15' AFG
AutoCAD SHX Text
WAP CONNECTIVITY AT POLE
AutoCAD SHX Text
TYPICAL PERIMETER TECHNOLOGY CABINET CABINET
AutoCAD SHX Text
LIGHTING ARRESTOR
AutoCAD SHX Text
INSTALL CAT-6A SHIELDED CABLE
AutoCAD SHX Text KEYED NOTES: PROVIDE ONE (1) SURGE SUPPRESSOR FOR EACH CAT-6A CABLE AT EACH POLE. INSTALL INSIDE THE PERIMETER CABINET. CUSTOM MOUNT THE WAP TO THE FRONT OF THE BOX ON THE POLE. PROVIDE SHORT COIL OF CABLE IN JUNCTION BOX. INSTALL A GROMMET OUT BOTTOM OF BOX FOR CABLE TO ROUTE TO WAP. PROVIDED AND INSTALL THE CABLE GLAND ON THE WAP. SEE LIST OF EQUIPMENT IN THIS DETAILS.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
INSTALL CONDUIT ON POLE 1" CONDUIT
AutoCAD SHX Text
UNDERGROUND RATED CAT-6A CABLE
AutoCAD SHX Text
ETHERNET SWITCH BY OWNER
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 CAT-6A CABLE-YELLOW MOHAWK M59230 CAT-6A CABLE-YELLOW MOHAWK M59230 MOHAWK M59230 M59230 2 CAT-6A COBRA COUPLER HUBBELL SC6A CAT-6A COBRA COUPLER HUBBELL SC6A HUBBELL SC6A SC6A 1 CAT-6 CABLE-UNDERGROUND -STANDARD DISTANCE CAT-6 CABLE-UNDERGROUND -STANDARD DISTANCE MOHAWK M59198 M59198 1 CABLE GLAND AT WAP CISCO PROVIDED BY OWNER CABLE GLAND AT WAP CISCO PROVIDED BY OWNER CISCO PROVIDED BY OWNER PROVIDED BY OWNER
AutoCAD SHX Text INSTALLATION NOTES: 1. INSTALL CABLE GLAND AT BOTTOM OF JUNCTION BOX 1 TO PROVIDE WEATHERPROOF TRANSITION FROM INSTALL CABLE GLAND AT BOTTOM OF JUNCTION BOX 1 TO PROVIDE WEATHERPROOF TRANSITION FROM BACKBOX TO CABLE OUTSIDE BOX. INSTALL EXTERIOR RATED CAT-6A CABLE FROM BACKBOX TO WAP. 2. TERMINATE EXTERIOR RATED CABLE ONTO THE CISCO CABLE GLAND. PLUG CABLE INTO THE WAP.TERMINATE EXTERIOR RATED CABLE ONTO THE CISCO CABLE GLAND. PLUG CABLE INTO THE WAP.
AutoCAD SHX Text
AutoCAD SHX Text
ROUTE NEW CABLE THRU EXISTING UNDERGROUND CONDUIT
AutoCAD SHX Text
SEE SITE PLAN FOR LOCATION OF POLE AND CABINET
AutoCAD SHX Text
INSTALL A NEMA 3X RATED BOX WITH HINGED COVER. JUNCTION BOX 1
AutoCAD SHX Text
CONNECT NEW CONDUIT TO EXISTING JUNCTION BOX
AutoCAD SHX Text
CAT-6A PATCH CABLE BY OWNER
AutoCAD SHX Text
INSTALL FLEXIBLE LIQUITITE CONDUIT BETWEEN EXISTING BOX ON POLE AND NEW BOX.
AutoCAD SHX Text
INSTALL A NEMA 3X RATED BOX WITH SCREW COVER. JUNCTION BOX 2
AutoCAD SHX Text
JUNCTION BOX 2
AutoCAD SHX Text
JUNCTION BOX 1
AutoCAD SHX Text
INSTALL WAP AND SECURE TO JUNCTION BOX 1
AutoCAD SHX Text
INSTALL A NEMA 3X RATED BOX WITH HINGED COVER. JUNCTION BOX 1
AutoCAD SHX Text
OUTDOOR RATED CAT-6A PATCH CABLE
AutoCAD SHX Text
WAP CONNECTIVITY AT CABINET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text index no.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text sheet title
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .