Tech data window section temper tan.pdf

PDF 142 KB Posted

Attached to
Window Section, Tan, Temper
Solicitation number
44597262
Issued by

About this file

Item Description and Iterim Changes for the Window Section Tan Temperate

View the file

Other files

File Type Posted
TDP.zip ZIP file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NSN(S) THIS PROCUREMENT

8340-01-213-6006

SECTION C - DESCRIPTION/SPECIFICATION

ITEM DESCRIPTION

WINDOW SECTION, DESERT/TROPICAL, DESERT TAN, US ARMY 686A

WINDOW SECTION, DESERT/TROPICAL, DESERT TAN, US ARMY 686A SHALL BE

IN ACCORDANCE WITH MILITARY SPECIFICATION MIL-PRF-44271, REVISION C,

DATED 16 SEPTEMBER, 2005, DRAWINGS 5-4-9755 SHEETS 1 AND 2 AND IN

ACCORDANCE WITH THE FOLLOWING PARTS BREAKDOWN:

NATIONAL STOCK

NUMBER

QUANTITY EACH

TENT

DESCRIPTION PART NUMBER

8340-01-213-6006 1 TENT SECTION DRAWING

5-4-9755

SHEET 11 AND 12

THE FOLLOWING VECP WILL ONLY APPLY TO THIS CONTRACT

WHEN CONVENTIONAL SEWN SEAMS ARE USED AND INDICATED IN

CLAUSE 52.248-9000/BSM# I48C01:

VECP 2002010 ½ INCH TURNUNDER IN-LIEU-OF 1 INCH TURNUNDER OF

THE BODY FABRIC FOR JOINING OF WINDOW SECTION

HALVES ON THE TEMPER TENT

DOOR/WINDOW SECTIONS (DESERT/TROPICAL) AND (TEMPERATE), SHALL BE IN

ACCORDANCE WITH THE FOLLOWING DRAWINGS:

DRAWING 5-4-3351 REV W, DOOR SECTION (DESERT/TROPICAL),

SHEET 1 AND 2, SECTION J-J

DRAWING 5-4-3352 REV V, WINDOW SECTION (DESERT/TROPICAL),

SHEET 1 AND 2, SECTION H-H

5-4-9755 SHEET 10 – THIS DRAWING IS CURRENTLY INACTIVE AND SHALL NOT BE

USED.

5-4-9755 SHEET 11 – THIS DRAWING IS CURRENTLY INACTIVE AND SHALL NOT BE

USED.

MIL-PRF-44271C TENT, EXTENDABLE, MODULAR,

PERSONNEL (TEMPER)

CHANGES FOR MIL-PRF-44271C:

ALL SEAMS ON THE TENT BODY THAT MAY BE EXPOSED TO ELEMENTS OF RAIN

OR SNOW SHALL BE DESIGNED TO PREVENT LEAKAGE OF WATER TO THE

INTERIOR OF THE TENT. THE USE OF THERMAL, ULTRASONIC, OR RADIO-

FREQUENCY (RF) WELDING, OR SIMILAR TECHNIQUES IS STRONGLY

RECOMMENDED TO PREVENT LEAKAGE. THE USE OF CONVENTIONAL SEWN

SEAMS, WHILE NOT RECOMMENDED, MAY BE ACCEPTABLE IF THE EXPOSED

SEWN SEAMS ARE AUGMENTED WITH HEAT-SEALED OR RF-WELDED

WATERPROOF TAPES TO PREVENT PENETRATION OF WATER THROUGH THE SEAM.

PARAGRAPH 1.1 CLASSIFICATION AND IDENTIFYING NUMBERS, CLASSES

UNDER CATORGORY CLASSES, CLASS 2, DELETE DESERT TAN NUMBER 459 AND

REPLACE WITH THE FOLLOWING: TAN 686A, CHIP NUMBER 33446, IN

ACCORDANCE WITH FEDERAL STANDARD 595C, COLORS USED IN GOVERNMENT

PROCUREMENT. THE COLOR REQUIREMENTS ARE DETAILED IN MIL-DTL-53039C

PARAGRAPH 3.3.1 TABLE 1. THE AVERAGE INFRARED REFLECTANCE SHALL BE 62

TO 72 PERCENT BETWEEN 720 TO 860 NANOMETERS. THIS NEW COLOR, TAN

686A, WILL REPLACE DESERT TAN 459.

ORDERING INFORMATION FOR COMMERCIAL CUSTOMERS: FAN DECKS, THE

COLOR BOOK, INDIVIDUAL COLOR CHIPS, SETS OF COLOR CHIPS ARE AVAILABLE

FOR SALE BY THE GENERAL SERVICES ADMINISTRATION AT THE FOLLOWING

ADDRESS:

-GENERAL SERVICES ADMINISTRATION PROPERTY MANAGEMENT

GSA/CO/3QSCB

490 L'ENFANT PLAZA EAST SW

SUITE 8214

WASHINGTON, DC 20407

-ORDERING INFORMATION FOR GOVERNMENT CUSTOMERS: INDIVIDUAL COLOR

CHIPS, COLOR BOOK, AND SETS OF COLOR CHIPS ARE AVAILABLE AT SAME

ADDRESS AS ABOVE. FAN DECKS ARE AVAILABLE VIA ROUTINE SUPPLY

CHANNELS UNDER NATIONAL STOCK NUMBER 7690-01-162-2210

THE NEW COLOR SHALL BE TAN 686A, CHIP NUMBER 33446, PER PARAGRAPH 6,

NOTES ON PAGE 4 OF FED-STD-595C, “THE CHIPS FOR CAMOUFLAGE COLORS

SHALL BE USED FOR GENERAL COLOR MATCHING PURPOSES ONLY, THE

SPECIFICATIONS FOR CAMOUFLAGE COATINGS CONTAIN REQUIREMENTS FOR

INFRARED REFLECTANCE WHICH MUST BE MET IN ADDITION TO COLOR. THE

COLOR CAEDS (CHIPS) FOR THE CAMOUFLAGE COLORS CONTAIN PIGMENTS

CHOSEN FOR THEIR SUITABILITY AND COMPATIBILITY WITH THE COLOR CARD

COATING AND, THEREFORE, HAVE DIFFERENT INFRARED REFLECTANCE

CHARACTERISTICS THEN THIS REQUIRED FOR CAMOUFLAGE COATINGS. MERELY

MATCHING THE COLOR CHIP FOR COLOR WILL NOT BE SUFFICIENT TO ASSURE

PRODUCT ACCEPTANCE BY THE CONTRACTING ACTIVITY. FOR FURTHER

INFORMATION, CONTACT FOR CAMOUFLAGE COLORS ONLY: U.S. ARMY

RESEARCH LABORATORY, CARC COMMODITY MANAGEMENT, ATTN: AMSRD-ARL-

WM-MC, ABERDEEN PROVING GROUND, MD 21005-5069.”

PARAGRAPH 3.5.1.1 END WALL

ADD THE FOLLOWING: "POTENTIAL WATER ENTRY ALONG THE TOP SEAM OF

EACH WINDOW SHALL BE DIVERTED BY A RAIN DIVERTER FLAP OR EQUIVALENT

FEATURE. A RAIN DIVERTER FLAP IS A STRIP OF FABRIC, IDENTICAL TO THE

FABRIC USED FOR THE EXTERIOR OF THE TENT, APPROXIMATELY 4 INCHES IN

HEIGHT, EXTENDING ACROSS THE TOP EDGE OF THE WINDOW OPENINGS AND AT

LEAST 2 INCHES ON EITHER SIDE OF THE WINDOW FLAP. THE RAIN DIVERTER

FLAP SHALL BE ATTACHED TO THE TENT BODY ALONG THE TOP EDGE BY USE OF

THERMAL, ULTRASONIC, OR RF WELDING TO PREVENT LEAKAGE. THE RAIN

DIVERTER FLAP SHALL BE POSITIONED SO THAT IT DIVERTS WATER OVER THE

TOP SEAM OF THE WINDOW AND SO THAT IT DOES NOT INTERFERE WITH

OPERATION OR REMOVAL OF THE WINDOW AND/OR WINDOW FLAP."

PARAGRAPH 3.5.1.2 WINDOW SECTION (TEMPERATE)

ADD THE FOLLOWING: "POTENTIAL WATER ENTRY ALONG THE TOP SEAM OF

EACH WINDOW SHALL BE DIVERTED BY A RAIN DIVERTER FLAP OR EQUIVALENT

FEATURE. A RAIN DIVERTER FLAP IS A STRIP OF FABRIC, IDENTICAL TO THE

FABRIC USED FOR THE EXTERIOR OF THE TENT, APPROXIMATELY 4 INCHES IN

HEIGHT, EXTENDING ACROSS THE TOP EDGE OF THE WINDOW OPENINGS AND AT

LEAST 2 INCHES ON EITHER SIDE OF THE WINDOW FLAP. THE RAIN DIVERTER

FLAP SHALL BE ATTACHED TO THE TENT BODY ALONG THE TOP EDGE BY USE OF

THERMAL, ULTRASONIC, OR RF WELDING TO PREVENT LEAKAGE. THE RAIN

DIVERTER FLAP SHALL BE POSITIONED SO THAT IT DIVERTS WATER OVER THE

TOP SEAM OF THE WINDOW AND SO THAT IT DOES NOT INTERFERE WITH

OPERATION OR REMOVAL OF THE WINDOW AND/OR WINDOW FLAP."

PARAGRAPH 3.5.1.3 WINDOW SECTION (DESERT/TROPICAL)

ADD THE FOLLOWING: "POTENTIAL WATER ENTRY ALONG THE TOP SEAM OF

EACH WINDOW SHALL BE DIVERTED BY A RAIN DIVERTER FLAP OR EQUIVALENT

FEATURE. A RAIN DIVERTER FLAP IS A STRIP OF FABRIC, IDENTICAL TO THE

FABRIC USED FOR THE EXTERIOR OF THE TENT, APPROXIMATELY 4 INCHES IN

HEIGHT, EXTENDING ACROSS THE TOP EDGE OF THE WINDOW OPENINGS AND AT

LEAST 2 INCHES ON EITHER SIDE OF THE WINDOW FLAP. THE RAIN DIVERTER

FLAP SHALL BE ATTACHED TO THE TENT BODY ALONG THE TOP EDGE BY USE OF

THERMAL, ULTRASONIC, OR RF WELDING TO PREVENT LEAKAGE. THE RAIN

DIVERTER FLAP SHALL BE POSITIONED SO THAT IT DIVERTS WATER OVER THE

TOP SEAM OF THE WINDOW AND SO THAT IT DOES NOT INTERFERE WITH

OPERATION OR REMOVAL OF THE WINDOW AND/OR WINDOW FLAP."

PARAGRAPH 3.5.1.4 DOOR SECTION (TEMPERATE)

ADD THE FOLLOWING: "POTENTIAL WATER ENTRY ALONG THE TOP SEAM OF

EACH WINDOW SHALL BE DIVERTED BY A RAIN DIVERTER FLAP OR EQUIVALENT

FEATURE. A RAIN DIVERTER FLAP IS A STRIP OF FABRIC, IDENTICAL TO THE

FABRIC USED FOR THE EXTERIOR OF THE TENT, APPROXIMATELY 4 INCHES IN

HEIGHT, EXTENDING ACROSS THE TOP EDGE OF THE WINDOW OPENINGS AND AT

LEAST 2 INCHES ON EITHER SIDE OF THE WINDOW FLAP. THE RAIN DIVERTER

FLAP SHALL BE ATTACHED TO THE TENT BODY ALONG THE TOP EDGE BY USE OF

THERMAL, ULTRASONIC, OR RF WELDING TO PREVENT LEAKAGE. THE RAIN

DIVERTER FLAP SHALL BE POSITIONED SO THAT IT DIVERTS WATER OVER THE

TOP SEAM OF THE WINDOW AND SO THAT IT DOES NOT INTERFERE WITH

OPERATION OR REMOVAL OF THE WINDOW AND/OR WINDOW FLAP."

PARAGRAPH 3.5.1.5 DOOR SECTION (DESERT/TROPICAL)

ADD THE FOLLOWING: "POTENTIAL WATER ENTRY ALONG THE TOP SEAM OF

EACH WINDOW SHALL BE DIVERTED BY A RAIN DIVERTER FLAP OR EQUIVALENT

FEATURE. A RAIN DIVERTER FLAP IS A STRIP OF FABRIC, IDENTICAL TO THE

FABRIC USED FOR THE EXTERIOR OF THE TENT, APPROXIMATELY 4 INCHES IN

HEIGHT, EXTENDING ACROSS THE TOP EDGE OF THE WINDOW OPENINGS AND AT

LEAST 2 INCHES ON EITHER SIDE OF THE WINDOW FLAP. THE RAIN DIVERTER

FLAP SHALL BE ATTACHED TO THE TENT BODY ALONG THE TOP EDGE BY USE OF

THERMAL, ULTRASONIC, OR RF WELDING TO PREVENT LEAKAGE. THE RAIN

DIVERTER FLAP SHALL BE POSITIONED SO THAT IT DIVERTS WATER OVER THE

TOP SEAM OF THE WINDOW AND SO THAT IT DOES NOT INTERFERE WITH

OPERATION OR REMOVAL OF THE WINDOW AND/OR WINDOW FLAP."

PARAGRAPH 3.5.1.7 INTERMEDIATE LINER (TEMPERATE)

ADD THE FOLLOWING: "THE CLEAR, FLEXIBLE WINDOW SHALL BE IN

ACCORDANCE WITH 5-4-9755, SHEET 12. (SEE ALSO CHANGES TO ICD 5-4-9755,

SHEET 37)"

PARAGRAPH 3.5.1.8 INTERMEDIATE LINER (DESERT/TROPICAL)

ADD THE FOLLOWING: "THE CLEAR, FLEXIBLE WINDOW SHALL BE IN

ACCORDANCE WITH 5-4-9755, SHEET 12. (SEE ALSO CHANGES TO ICD 5-4-9755,

SHEET 38)"

PARAGRAPH 3.5.1.9 END SECTION LINER (TEMPERATE AND DESERT/TROPICAL)

ADD THE FOLLOWING: "THE CLEAR, FLEXIBLE WINDOWS USED IN THE SIDE

WALLS OF THE LINER SHALL BE IN ACCORDANCE WITH 5-4-9755, SHEET 12. (SEE

ALSO CHANGES TO ICD 5-4-9755, SHEET 34 AND SHEET 35)"

PARAGRAPH 3.5.1.17 FLOOR 8’, INSULATED

IN THE SECOND TO LAST SENTENCE, DELETE “, AND THE R FACTOR SHALL BE 6.5

OR MORE”

PARAGRAPH 3.5.2.7 FABRIC WEIGHT

ON LINE 3, DELETE "4.0 OZ/SQ. YD." AND SUBSTITUTE "7.0 OZ/SQ. YD."

PARAGRAPH 3.5.1.22 VESTIBULE FLOOR, INSULATED

IN THE SECOND TO LAST SENTENCE, DELETE “, AND THE R FACTOR SHALL BE 6.5

OR MORE”

PARAGRAPH 3.7.3 IDENTIFICATION AND MARKING

ADD THE FOLLOWING:

TENTAGE LABELS FOR INDIVIDUAL COMPONENTS SHALL CONTAIN THE

FOLLOWING INFORMATION, IN ADDITION TO ANY INFORMATION SPECIFIED ON

THE COMPONENT'S INTERFACE CONTROL DRAWING:

"COMPONENT: [INSERT COMPONENT NOMENCLATURE]

COMPONENT NSN: [INSERT COMPONENT NSN]

CONTRACT #: [INSERT CONTRACT NUMBER]

[INSERT CONTRACTOR'S NAME, INCLUDING TRADEMARK OR CORPORATE LOGO

IF DESIRED]

CAGE CODE: [INSERT CODE]

QUANITY: [INSERT UNIT OF ISSUE QUANITY]

MANUFACTURE DATE: [INSERT DATE]

LOT NUMBER: [INSERT LOT NUMBER]"

THE IDENTIFICATION LABELS THAT SHALL BE PERMANENTLY ATTACHED TO THE

TENT FABRIC END SECTIONS AND STORAGE COVERS. THE LABEL SHALL BE A

MINIMUM OF 7 INCHES WIDE AND 7 INCHES HIGH WHITE FABRIC. THE LABEL

SHALL BE PRINTED IN A PERMANENT MARKING MEDIUM WITH THE FOLLOWING

NOMENCLATURE:

"COMPONENT: [INSERT COMPONENT NOMENCLATURE]

COMPONENT NSN: [INSERT COMPONENT NSN]

CONTRACT #: [INSERT CONTRACT NUMBER]

[INSERT CONTRACTOR'S NAME, INCLUDING TRADEMARK OR CORPORATE LOGO

IF DESIRED]

CAGE CODE: [INSERT CODE]

QUANITY: [INSERT UNIT OF ISSUE QUANITY]

MANUFACTURE DATE: [INSERT DATE]

LOT NUMBER: [INSERT LOT NUMBER]"

THE ATTACHMENT METHOD FOR LABELS AS FOLLOWS: “THE LABELS SHALL BE

PLACED CENTERED SEWN AND TO A SEPARATE PANEL OF BODY MATERIAL. THE

PANEL SHALL BE DIMENSIONED LARGER THAN THE LABELS TO ALLOW THE

EDGES OF THE PANEL TO BE THERMALLY SEALED TO THE TENT SECTION.

ADDITIONALLY IN PREFERENCE, ANY LABEL MY BE SECURED INO AN EXISTING

SEAM ALONG THE TOP EDGE IN LIEU OF STITCHING AROUND THE ENTIRE

PERMETER.

PARAGRAPH 4.5.2.11 LINER INSPECTION.

DELETE THE PARAGRAPH IN ITS ENTIRETY AND REPLACE WITH THE FOLLOWING:

"4.5.2.11 LINER INSPECTION. VISUALLY CONFIRM THAT THE LINER

CONFIGURATION AND INTERFACE DESIGN ARE ACCORDING TO ITS ICD. PERFORM

A TEAR STRENGTH TEST ON THE LINER ACCORDING TO ASTM-D2261. ONE

MAXIMUM PEAK LOAD SHALL BE RECORDED. THE MACHINE SHALL TEAR A

MINIMUM DISTANCE OF 3 INCHES. THE FORCE NECESSARY TO TEAR THE CLOTH

SHALL BE OBSERVED BY MEANS OF AN AUTOGRAPHIC RECORDING DEVICE. IN

CASE OF FAILURE BY YARN PULLOUT, RATHER THAN YARN BREAKAGE,

SPECIMENS SHALL BE CUT 8 BY 11 INCHES. PERFORM THE FOLLOWING FIELD

CLEANING TEST PROCEDURE ON THE LINER FABRIC:

1. DILUTE STANDARD HOUSEHOLD CHLORINE BLEACH (5.25 PERCENT SODIUM

HYPOCHLORITE ACTIVE INGREDIENT) BY MIXING 1 CUP OF BLEACH PER 1 GALLON

OF CLEAN WATER.

2. BRUSH OR SPRAY AFFECTED AREA WITH THE DILUTE BLEACH SOLUTION.

PREFERABLY, THE CLEANING IS DONE WHILE THE TENT IS ERECTED.

3. BRUSH THE AREA WELL TO REMOVE THE MILDEW AND/OR MOLD. LET STAND

UNTIL MILDEW AND/OR MOLD IS VISUALLY REMOVED.

4. RINSE THE BLEACHED AREA THOROUGHLY WITH WATER.

5. LET DRY COMPLETELY BEFORE FOLDING AND STORING.

ALL THE MATERIALS ARE AVAILABLE THROUGH GSA.

PRECAUTIONS FOR SAFE HANDLING AND USE OF BLEACH: BLEACH IS A

CORROSIVE MATERIAL THAT CAN CAUSE SKIN, EYE AND NOSE IRRITATION. AVOID

EYE/SKIN CONTACT AND INHALATION OF VAPOR MIST. THE FOLLOWING

PRECAUTIONS SHOULD BE TAKEN WHEN HANDLING: USE GLOVES, APRON,

GOGGLES OR SAFETY GLASSES. MANY COLORED FABRICS (GARMENTS) ARE

DAMAGED OR DISCOLORED BY BLEACH, INCLUDING THE BATTLEDRESS

UNIFORM. PLEASE USE APPOPRIATE PROTECTIVE CLOTHING WHEN HANDLING.

FOLLOW MANUFACTURER'S RECOMMENDED SAFETY PRECAUTIONS.

INSPECT THE LINER MATERIAL FOR ANY COLOR CHANGE, FADING, OR

DETERIORATION. NON-COMPLIANCE WITH THE ICD, ANY COLOR CHANGE OR

DETERIORATION FROM CLEANING, OR TEAR STRENGTH OF LESS THAN 17 POUNDS

SHALL BE RECORDED AS A FAILURE."

PARAGRAPH 4.5.2.12 PLENUM INSPECTION.

IN THE THIRD SENTENCE, DELETE THE PHRASE ENCLOSED IN PARENTHESES AND

REPLACE WITH THE FOLLOWING:

"(ACCORDING TO STEP 1 OF THE FIELD CLEANING TEST PROCEDURE IN

PARAGRAPH 4.5.2.11)"

ADD THE FOLLOWING PARAGRAPH:

"4.5.2.14 PARTITION AND MODESTY CURTAIN INSPECTION.

VISUALLY CONFIRM THAT THE PARTITION AND MODESTY CURTAIN

CONFIGURATION AND INTERFACE DESIGN ARE ACCORDING TO THEIR

RESPECTIVE ICD. PERFORM A TEAR STRENGTH TEST ON THE FABRIC ACCORDING

TO ASTM-D2261. ONE MAXIMUM PEAK LOAD SHALL BE RECORDED. THE

MACHINE SHALL TEAR A MINIMUM DISTANCE OF 3 INCHES. THE FORCE

NECESSARY TO TEAR THE CLOTH SHALL BE OBSERVED BY MEANS OF AN

AUTOGRAPHIC RECORDING DEVICE. IN CASE OF FAILURE BY YARN PULLOUT,

RATHER THAN YARN BREAKAGE, SPECIMENS SHALL BE CUT 8 BY 11 INCHES.

PERFORM THE FOLLOWING FIELD CLEANING TEST PROCEDURE ON THE FABRIC:

1. DILUTE STANDARD HOUSEHOLD CHLORINE BLEACH (5.25 PERCENT SODIUM

HYPOCHLORITE ACTIVE INGREDIENT) BY MIXING 1 CUP OF BLEACH PER 1 GALLON

OF CLEAN WATER.

2. BRUSH OR SPRAY AFFECTED AREA WITH THE DILUTE BLEACH SOLUTION.

PREFERABLY, THE CLEANING IS DONE WHILE THE TENT IS ERECTED.

3. BRUSH THE AREA WELL TO REMOVE THE MILDEW AND/OR MOLD. LET STAND

UNTIL MILDEW AND/OR MOLD IS VISUALLY REMOVED.

4. RINSE THE BLEACHED AREA THOROUGHLY WITH WATER.

5. LET DRY COMPLETELY BEFORE FOLDING AND STORING.

ALL THE MATERIALS ARE AVAILABLE THROUGH GSA.

PRECAUTIONS FOR SAFE HANDLING AND USE OF BLEACH: BLEACH IS A

CORROSIVE MATERIAL THAT CAN CAUSE SKIN, EYE AND NOSE IRRITATION. AVOID

EYE/SKIN CONTACT AND INHALATION OF VAPOR MIST. THE FOLLOWING

PRECAUTIONS SHOULD BE TAKEN WHEN HANDLING: USE GLOVES, APRON,

GOGGLES OR SAFETY GLASSES. MANY COLORED FABRICS (GARMENTS) ARE

DAMAGED OR DISCOLORED BY BLEACH, INCLUDING THE BATTLEDRESS

UNIFORM. PLEASE USE APPOPRIATE PROTECTIVE CLOTHING WHEN HANDLING.

FOLLOW MANUFACTURER'S RECOMMENDED SAFETY PRECAUTIONS.

INSPECT THE FABRIC FOR ANY COLOR CHANGE, FADING, OR DETERIORATION.

NON-COMPLIANCE WITH THE ICD, ANY COLOR CHANGE OR DETERIORATION FROM

CLEANING, OR TEAR STRENGTH OF LESS THAN 17 POUNDS SHALL BE RECORDED

AS A FAILURE."

DRAWINGS - CARTOONS - PATTERNS

INTERIM CHANGES TO 5-4-9755 ARE AS FOLLOWS:

GENERAL NOTES FOR 5-4-9755:

5-4-9755 DATED 20 SEPT 2005, WITH THE FOLLOWING CHANGES:

WHEREVER PRACTICAL, TENTAGE LABELS INDICATED ON THESE DRAWINGS

SHALL BE SEWN INTO AN EXISTING ADJACENT SEAM, PROVIDED THAT THE

VISIBILITY OF THE LABELS ON THE ERECTED TENT IS NOT OBSCURED.

5-4-9755 SHEET 1 - NO CHANGES

5-4-9755 SHEET 2 - NO CHANGES

5-4-9755 SHEET 3 - NO CHANGES

5-4-9755 SHEET 4 - NO CHANGES

5-4-9755 SHEET 5 - IN ZONE D8, DELETE "GOTHIC" AND REPLACE WITH "ARIAL".

TWO (2) "US" MARKINGS ARE ACCEPTABLE FOR EACH 16' FLY, IN LIEU OF THE

FOUR (4) MARKINGS SHOWN. THE TWO MARKINGS SHALL APPEAR ON OPPOSITE

SIDES OF THE RIDGE LINE ON THE ERECTED TENT, AND SHALL BE CENTERED

HORIZONTALLY AT THE CENTER LINE OF THE FLY.

TIE TAPES FOR THE STOVEPIPE FLAP SHALL BE INCORPORATED BOTH ON THE

OUTSIDE OF THE STOVEPIPE FLAP, AND ON THE OUTSIDE OF THE STOVEPIPE

ADAPTER PANEL (UNDER THE STOVEPIPE FLAP), SO THAT THE FLAP MAY BE

ROLLED UP AND SECURED WHEN STOVEPIPE IS PRESENT.

5-4-9755 SHEET 6 - IN ZONE E8, DELETE "GOTHIC" AND REPLACE WITH "ARIAL".

TIE TAPES FOR THE STOVEPIPE FLAP SHALL BE INCORPORATED BOTH ON THE

OUTSIDE OF THE STOVEPIPE FLAP, AND ON THE OUTSIDE OF THE STOVEPIPE

ADAPTER PANEL (UNDER THE STOVEPIPE FLAP), SO THAT THE FLAP MAY BE

ROLLED UP AND SECURED WHEN A STOVEPIPE IS PRESENT.

5-4-9755 SHEET 7 - MARK IN PERMANENT BLACK INK, WITH 1" HIGH ARIAL FONT

LETTERS, THE FOLLOWING INSTRUCTION:

"CLOSE SLIDE FASTENERS AND SNAPHOOKS BEFORE ERECTING"

THIS NOTATION SHALL BE CENTERED HORIZONTALLY ON THE OUTSIDE OF DOOR,

APPROXIMATELY 6" FROM LOWER EDGE OF DOOR. SEE DRAWING 5-4-9755

SHEET 13 FOR REFERENCE.

TIE TAPES FOR THE WINDOW FLAPS SHALL BE INCORPORATED BOTH ON THE

OUTSIDE OF THE WINDOW FLAP, AND ON THE OUTSIDE TOP EDGE OF THE

WINDOW SCREEN, SO THAT THE WINDOW FLAP MAY BE ROLLED UP REGARDLESS

OF WHETHER A REMOVABLE PLASTIC WINDOW PANE IS PRESENT.

5-4-9755 SHEET 8 - IN ZONE D6, DELETE "27" AND REPLACE WITH "28".

THE SIDE OF THE ADAPTER CONTAINING THE 14 #2 GROMMETS SHALL

INCORPORATE A 2" WIDE LOOP FASTENER TAPE ALONG THE INTERIOR EDGE IN

ORDER TO FACILITATE INTERFACE WITH THE DOUBLE-BUMP DOOR ASSEMBLY.

THE 2" WIDE LOOP FASTENER TAPE SHALL EXTEND APPROXIMATELY FROM THE

GROUND LINE TO THE 2" SLIT SHOWN IN VIEW G.

5-4-9755 SHEET 9 - IN SECTION A-A, ZONE C6, DELETE "36"L" AND REPLACE WITH

"18"L". OMIT THE TIE TAPE SHOWN ON THE INSIDE OF THE WINDOW PANE. IN

ZONE D7, RELOCATE THE FASTENER TAPE (LOOP) TO THE INSIDE OF THE WINDOW

PANE. IN ZONE B7, RELOCATE THE FASTENER TAPE (LOOP) TO THE INSIDE OF

THE WINDOW PANE, AND RELOCATE THE FASTENER TAPE (HOOK) TO THE

OUTSIDE OF THE WINDOW PANE.

IN SECTION B-B, ZONE A5, RELOCATE THE FASTENER TAPE (LOOP) TO THE INSIDE

OF THE WINDOW PANE, AND RELOCATE THE FASTENER TAPE (HOOK) TO THE

OUTSIDE OF THE WINDOW PANE.

5-4-9755 SHEET 10 - TIE TAPES FOR THE WINDOW FLAPS SHALL BE

INCORPORATED BOTH ON THE OUTSIDE OF THE WINDOW FLAP, AND ON THE

OUTSIDE TOP EDGE OF THE WINDOW SCREEN, SO THAT THE WINDOW FLAP MAY

BE ROLLED UP REGARDLESS OF WHETHER A REMOVABLE PLASTIC WINDOW PANE

IS PRESENT.

TIE TAPES FOR THE STOVEPIPE FLAP SHALL BE INCORPORATED BOTH ON THE

OUTSIDE OF THE STOVEPIPE FLAP, AND ON THE OUTSIDE OF THE STOVEPIPE

ADAPTER PANEL (UNDER THE STOVEPIPE FLAP), SO THAT THE FLAP MAY BE

ROLLED UP AND SECURED WHEN STOVEPIPE IS PRESENT.

5-4-9755 SHEET 11 - TIE TAPES FOR THE WINDOW FLAPS SHALL BE

INCORPORATED BOTH ON THE OUTSIDE OF THE WINDOW FLAP, AND ON THE

OUTSIDE TOP EDGE OF THE WINDOW SCREEN, SO THAT THE WINDOW FLAP MAY

BE ROLLED UP REGARDLESS OF WHETHER A REMOVABLE PLASTIC WINDOW PANE

IS PRESENT.

5-4-9755 SHEET 12 - DELETE THE BROKEN LINES THAT EXTEND FROM ZONE B6

THROUGH C6 AND FROM ZONE B2 THROUGH C2, AND REPLACE WITH SOLID

LINES. IN THE MAIN VIEW, THE LENGTH OF THE TIE TAPES SHALL BE 20". IN

SECTION A-A, ZONE C7, RELOCATE THE FASTENER TAPE (LOOP) TO THE INSIDE OF

THE WINDOW PANE. IN ZONE B7, RELOCATE THE FASTENER TAPE (LOOP) TO THE

INSIDE OF THE WINDOW PANE, AND RELOCATE THE FASTENER TAPE (HOOK) TO

THE OUTSIDE OF THE WINDOW PANE. IN SECTION B-B, ZONE A7, ADD FASTENER

TAPE (HOOK) TO THE OUTSIDE OF THE WINDOW PANE.

5-4-9755 SHEET 13 - NO CHANGES

5-4-9755 SHEET 14 - NO CHANGES

5-4-9755 SHEET 15 - THE SIDE OF THE ADAPTER CONTAINING THE 14 #2

GROMMETS SHALL INCORPORATE A 2" WIDE LOOP FASTENER TAPE ALONG THE

INTERIOR EDGE IN ORDER TO FACILITATE INTERFACE WITH THE DOUBLE-BUMP

DOOR ASSEMBLY. THE 2" WIDE LOOP FASTENER TAPE SHALL EXTEND

APPROXIMATELY FROM THE GROUND LINE TO THE 2" SLIT SHOWN IN VIEW D.

5-4-9755 SHEET 16 - THE VESTIBULE SHALL INCORPORATE TWO 2" WIDE LOOP

FASTENER TAPES ALONG THE INTERIOR EDGES OF THE GROMMET LINES (ZONES

G6-G7, AND C2-C3-C4) IN ORDER TO FACILITATE INTERFACE WITH THE DOUBLE-

BUMP DOOR ASSEMBLY. THE 2" WIDE LOOP FASTENER TAPES SHALL EXTEND

APPROXIMATELY FROM THE GROUND LINE TO THE #4 GROMMETS AT THE EAVE

OF THE VESTIBULE (ZONES C4 AND G5).

5-4-9755 SHEET 17 - NO CHANGES

5-4-9755 SHEET 18 - NO CHANGES

5-4-9755 SHEET 19 - NO CHANGES

5-4-9755 SHEET 20 - NO CHANGES

5-4-9755 SHEET 21 - NO CHANGES

5-4-9755 SHEET 22 - NO CHANGES

5-4-9755 SHEET 23 - NO CHANGES

5-4-9755 SHEET 24 - NO CHANGES

5-4-9755 SHEET 25 - NO CHANGES

5-4-9755 SHEET 26 - NO CHANGES

5-4-9755 SHEET 27 - NO CHANGES

5-4-9755 SHEET 28 - NO CHANGES

5-4-9755 SHEET 29 - NO CHANGES

5-4-9755 SHEET 30 - NO CHANGES

5-4-9755 SHEET 31 - NO CHANGES

5-4-9755 SHEET 32 - NO CHANGES

5-4-9755 SHEET 33 - IN ZONE F7, DELETE "25 1/2" AND REPLACE WITH "24". IN

ZONE E6, DELETE "32" AND REPLACE WITH "28". ADD THE FOLLOWING NOTE:

"THE END WALL LINER SHALL BE FITTED WITH TWO REMOVABLE WINDOW

ASSEMBLIES IN ACCORDANCE WITH 5-4-9755 SHEET 36."

5-4-9755 SHEET 34 - IN ZONE B7, DELETE "8'-- 1 1/2" " AND REPLACE WITH "8'-- 2

1/2" "

IN ZONE B7, DELETE "48 3/4" " AND REPLACE WITH "49 1/4" "

IN ZONE B5, DELETE "8'-1 1/2" " AND REPLACE WITH "8'-2 1/2" "

IN ZONE B5, DELETE "16-12" " AND REPLACE WITH "11" "

IN ZONE B5, DELETE "4'-9" OPENING " AND REPLACE WITH "5'-8" OPENING "

IN ZONE B5, DELETE "28-1/2" " AND REPLACE WITH "34" "

IN ZONE D5, DELETE "28-1/2" " AND REPLACE WITH "34" "

IN ZONE B3, DELETE "4'-11" " AND REPLACE WITH "6' "

ELIMINATE THE 4 STRAPS ALONG THE EDGE OF THE LINER IN ZONES H7, G7 AND

F7, AND WHERE THE SAME 4 STRAPS APPEAR ON THE OUTSIDE VIEW AT H4, G4

AND F4.

IN ZONE B6, DELETE "29X" AND REPLACE WITH "25X"

IN ZONE F8, CHANGE THE DIMENSION OF THE SLIT INDICATED AT THE RIDGE

LINE OF THE PANEL FROM 1" TO 2". THIS SLIT SHOULD EXTEND TO THE EDGE OF

THE FABRIC PANEL TO FACILITATE INTERFACE WITH THE ADJOINING PANEL.

5-4-9755 SHEET 35 - IN ZONE B7, DELETE "8'-- 1 1/2" " AND REPLACE WITH "8'-- 2

1/2" "

IN ZONE B7, DELETE "48 3/4" " AND REPLACE WITH "49 1/4" "

IN ZONE B5, DELETE "8'-1 1/2" " AND REPLACE WITH "8'-2 1/2" "

IN ZONE B4, DELETE "16-12" " AND REPLACE WITH "11" "

IN ZONE B5, DELETE "4'-9" OPENING " AND REPLACE WITH "5'-8" OPENING "

IN ZONE B5, DELETE "28-1/2" " AND REPLACE WITH "34" "

IN ZONE D4, DELETE "28-1/2" " AND REPLACE WITH "34" "

IN ZONE B3, DELETE "4'-11" " AND REPLACE WITH "6' "

ELIMINATE THE 4 STRAPS ALONG THE EDGE OF THE LINER IN ZONES H7, G7 AND

F7, AND WHERE THE SAME 4 STRAPS APPEAR ON THE OUTSIDE VIEW AT H4, G4

AND F4.

IN ZONE B6, DELETE "29X" AND REPLACE WITH "25X"

IN ZONE F8, CHANGE THE DIMENSION OF THE SLIT INDICATED AT THE RIDGE

LINE OF THE PANEL FROM 1" TO 2". THIS SLIT SHOULD EXTEND TO THE EDGE OF

THE FABRIC PANEL TO FACILITATE INTERFACE WITH THE ADJOINING PANEL.

5-4-9755 SHEET 36 - NO CHANGES

5-4-9755 SHEET 37 - IN ZONE B7, DELETE "8'-- 1 1/2" " AND REPLACE WITH "8'-- 3

1/2" "

IN ZONE B7, DELETE "48 3/4" AND REPLACE WITH "49 3/4"

IN ZONE B6, DELETE "38X" AND REPLACE WITH "30X"

IN ZONE B5, DELETE "8'-- 1 1/2" "AND REPLACE WITH "8'-- 3 1/2" "

IN ZONE B5, DELETE "16-12" " AND REPLACE WITH "11" "

IN ZONE B5, DELETE "4'-9" OPENING " AND REPLACE WITH "5'-8" OPENING "

IN ZONE B5, DELETE "28-1/2" " AND REPLACE WITH "34" "

IN ZONE D5, DELETE "28-1/2" " AND REPLACE WITH "34" "

IN ZONE B3, DELETE "4'-11" " AND REPLACE WITH "6' "

ELIMINATE THE 4 STRAPS ALONG THE EDGE OF THE LINER, IN ZONES H7, G7, AND

F7, AND WHERE THE SAME STRAPS APPEAR ON THE OUTSIDE VIEW IN H4, G4,

AND F4.

ELIMINATE THE 4 STRAPS ALONG THE EDGE OF THE LINER IN ZONES C6, D6, AND

E6, AND WHERE THE SAME STRAPS APPEAR ON THE OUTSIDE VIEW IN C5, D5,

AND E5. THE STRAP AT THE RIDGE LINE IN E6 SHALL REMAIN.

IN ZONE E6, CHANGE THE DIMENSION OF THE SLIT INDICATED AT THE RIDGE

LINE OF THE PANEL FROM 1" TO 2". THIS SLIT SHOULD EXTEND TO THE EDGE OF

THE FABRIC PANEL TO FACILITATE INTERFACE WITH THE ADJOINING PANEL.

5-4-9755 SHEET 38 - IN ZONE B7, DELETE "8'-- 1 1/2" " AND REPLACE WITH "8'-- 3

1/2" "

IN ZONE B7, DELETE "48 3/4" AND REPLACE WITH "49 3/4"

IN ZONE B6, DELETE "38X" AND REPLACE WITH "30X"

IN ZONE B5, DELETE "8'-- 1 1/2" "AND REPLACE WITH "8'-- 3 1/2" "

IN ZONE B4, DELETE "16-12" " AND REPLACE WITH "11" "

IN ZONE B5, DELETE "4'-9" OPENING " AND REPLACE WITH "5'-8" OPENING "

IN ZONE B5, DELETE "28-1/2" " AND REPLACE WITH "34" "

IN ZONE D4, DELETE "28-1/2" " AND REPLACE WITH "34" "

IN ZONE B3, DELETE "4'-11" " AND REPLACE WITH "6' "

ELIMINATE THE 4 STRAPS ALONG THE EDGE OF THE LINER, IN ZONES H7, G7, AND

F7, AND WHERE THE SAME STRAPS APPEAR ON THE OUTSIDE VIEW IN H4, G4,

AND F4.

ELIMINATE THE 4 STRAPS ALONG THE EDGE OF THE LINER IN ZONES C6, D6, AND

E6, AND WHERE THE SAME STRAPS APPEAR ON THE OUTSIDE VIEW IN C5, D5,

AND E5. THE STRAP AT THE RIDGE LINE IN E6 SHALL REMAIN.

IN ZONE E6, CHANGE THE DIMENSION OF THE SLIT INDICATED AT THE RIDGE

LINE OF THE PANEL FROM 1" TO 2". THIS SLIT SHOULD EXTEND TO THE EDGE OF

THE FABRIC PANEL TO FACILITATE INTERFACE WITH THE ADJOINING PANEL.

5-4-9755 SHEET 39 - THIS DRAWING IS CURRENTLY INACTIVE AND SHALL NOT BE

USED.

5-4-9755 SHEET 40 - THIS DRAWING IS CURRENTLY INACTIVE AND SHALL NOT BE

5-4-9755 SHEET 41 - THIS DRAWING IS CURRENTLY INACTIVE AND SHALL NOT BE

5-4-9755 SHEET 42 - THIS DRAWING IS CURRENTLY INACTIVE AND SHALL NOT BE

USED.

5-4-9755 SHEET 43 - THIS DRAWING IS CURRENTLY INACTIVE AND SHALL NOT BE

USED.

5-4-9755 SHEET 44 - THIS DRAWING IS CURRENTLY INACTIVE AND SHALL NOT BE

USED.

PLENUM ASSEMBLIES SHALL BE IN ACCORDANCE WITH THE FOLLOWING

DRAWINGS:

5-4-3614 REV F, DATED 2/10/00

5-4-3615 REV E, DATED 7/6/87

5-4-3616 REV C, DATED 3/23/99

5-4-3618 REV C, DATED 3/18/85

5-4-3619 REV E, DATED 7/6/87

5-4-3620 REV D, DATED 2/10/00

5-4-7970 DATED 8/14/98

5-4-7971 DATED 8/14/98

5-4-7972 DATED 8/14/98

5-4-7973 DATED 8/14/98

5-4-7974 DATED 8/14/98

5-4-7975 DATED 8/14/98

5-4-7976 DATED 8/14/98

5-4-7977 DATED 8/14/98

5-4-7978 DATED 8/14/98

5-4-7979 DATED 8/14/98

5-4-7980 DATED 8/14/98

5-4-7981 DATED 8/14/98

5-4-7982 DATED 8/14/98

5-4-7983 DATED 8/14/98

5-4-7984 DATED 8/14/98

PARTS LISTS:

PL5-4-3616 REV C, DATED 3/23/99

PL5-4-7970 DATED 8/14/98

5-4-9755 SHEET 45 - IN ZONE H3, DELETE "HOOK" AND REPLACE WITH "LOOP"

IN ZONE D2, DELETE "LOOP" AND REPLACE WITH "HOOK"

IN ZONE D3, DELETE "HOOK" AND REPLACE WITH "LOOP"

IN ZONE A2, DELETE "LOOP" AND REPLACE WITH "HOOK"

5-4-9755 SHEET 46 - NO CHANGES

5-4-9755 SHEET 47 - NO CHANGES

5-4-9755 SHEET 48 - IN ZONE G4, DELETE "HOOK" AND REPLACE WITH "LOOP"

IN ZONE F3, DELETE "HOOK" AND REPLACE WITH "LOOP"

IN ZONE C2, DELETE "LOOP" AND REPLACE WITH "HOOK"

5-4-9755 SHEET 49 - NO CHANGES

5-4-9755 SHEET 50 - NO CHANGES

5-4-9755 SHEET 51 - NO CHANGES

5-4-9755 SHEET 52 - IN ZONE H7, DELETE "GOTHIC" AND REPLACE WITH "ARIAL".

ADD THE FOLLOWING SENTENCE UNDER THE NOTES:

"NOMENCLATURES AND ANY OTHER MARKINGS SHALL BE SPECIFIED IN THE

CONTRACT OR PURCHASE ORDER."

5-4-9755 SHEET 53 - IN ZONE C5, DELETE "GOTHIC" AND REPLACE WITH "ARIAL".

ADD THE FOLLOWING NOTE:

"NOMENCLATURES AND ANY OTHER MARKINGS SHALL BE SPECIFIED IN THE

CONTRACT OR PURCHASE ORDER."

IN ZONE E6, DELETE "BOTH SIDES". ADD THE FOLLOWING NOTE: "THE LETTERS

"US" SHALL BE MARKED ON THE OUTSIDE OF THE COVER; THE CONTENTS SHALL

BE MARKED ON BOTH THE OUTSIDE AND THE INSIDE OF THE COVER. SEE 5-4-

3347 FOR GUIDANCE."

5-4-9755 SHEET 54 - IN ZONE B6, DELETE "GOTHIC" AND REPLACE WITH "ARIAL".

IN ZONE B2, DELETE 4" AND REPLACE WITH 6". THE TENTAGE LABEL SHALL BE

RELOCATED TO THE BOTTOM (CLOSED END) OF THE CONTAINER.

5-4-9755 SHEET 55 - IN ZONE B6, DELETE "GOTHIC" AND REPLACE WITH "ARIAL".

5-4-1 TENT, PIN, WOOD; REV. 16, 02/02/82

5-4-791 REV. F TENT, PIN, METAL 11/30/87

5-4-3358 ERECTION INSTRUCTIONS SH. 1 REV B, 4/2/85; SH. 2 REV

C, 9/5/85\

5-4-8489 TENT, EXTENDABLE, MODULAR, PERSONNEL (TEMPER) ASSEMBLY

COMPONENTS

SHEET 1, REV. C, 3/21/03

SHEET 2, REV. C, 3/21/03

SHEET 3, REV. C, 3/21/03

8-1-10 REV N SHIELD, STOVEPIPE, TENT, NONMETALIC 12/20/83

IMPORTANT NOTE:

ACCOMPANING DOCUMENTS INCLUDED IN THIS TECHNICAL DATA PACKAGE

LABELED “HISTORICAL TECHNICAL DATA FOR REFERENCES PURPOSES ONLY’”

MAY BE USED TO IDENTIFY THE TYPE, QUALITY, AND QUALITY OF MATERIALS AND

METHODS OF CONSTRUCTION THAT HAVE BEEN HISTORICALLY ACCEPTABLE IN

THE MANUFACTURE OF TEMPER TENT SYSTEMS AND COMPONENTS. THE

HISTORICAL DOCUMENTS ARE NOT TO BE USED FOR INSPECTION OR LOT

RELEASE PURPOSES UNLESS SPECIFICALLY APPROVED BY THE DLA TROOP

SUPPORT CONTRACTING OFFICER THROUGH MODIFICATION TO THE CONTRACT.

CONTRACTOR'S TECHNICAL DATA PACKAGE:

GOVERNMENT DRAWING 5-4-9755 IDENTIFIES COMPONENT INTERFACE CONTROL

REQUIREMENTS NECESSARY FOR INTEGRATION AND FACILITATION OF THE

DEVELOPED ITEM. 5-4-9755 DOES NOT IDENTIFY ALL NECESSARY DETAILED

MATERIAL REQUIREMENTS OR METHODS OF CONSTRUCTION. THE CONTRACTOR

SHALL DEVELOP AND DOCUMENT A TECHNICAL DATA PACKAGE (TDP) THAT

ENCOMPASSES THE REQUIREMENTS OF 5-4-9755 AND MIL-PRF-44271C. THE

CONTRACTOR'S TDP SHALL IDENTIFY, AT MINIMUM, ALL MATERIALS (INCLUDING

SPECIFICATIONS), METHODS OF CONSTRUCTION, VISUAL AND DIMENSIONAL

CHARACTERISTICS PERTINENT TO THE MATERIEL BEING PROCURED BY THE

GOVERNMENT.

THE CONTRACTOR SHALL DEVELOP AND DOCUMENT THEIR OWN DETAILED PARTS

LIST AND METHOD OF CONSTRUCTION ENGINEERING DRAWINGS. A COPY OF THE

TECHNICAL PACKAGE SHALL BE PRESENTED TO THE DLA TROOP SUPPORT

CONTRACTING OFFICER ALONG WITH THE PRODUCT DEMONSTRATION MODEL OR

FIRST ARTICLE. ANY PDM OR FIRST ARTICLE SUBMISSION LACKING A

COMPLETE DOCUMENTED TECHNICAL DATA PACKAGE SHALL BE CONSIDERED

AN INCOMPLETE SUBMISSION AND WILL NOT BE ACCEPTED.

THE SPECIFICATIONS OF THE COMPONENTS AND SOURCES OF COMPONENT

MATERIALS SHALL BE IDENTIFIED, INCLUDING APPLICABLE SPECIFICATIONS, AND

SHALL NOT BE CHANGED THROUGHOUT THE LIFE OF THE CONTRACT WITHOUT

REQUEST AND APPROVAL BY THE DLA TROOP SUPPORT CONTRACTING OFFICER

THROUGH MODIFICATION TO THE CONTRACT.

THE FIRST ARTICLE (FA) SHALL BE A PACKAGED AND PRESERVED COMPLETE END

ITEM. THE UNIT SHALL BE ERECTED IN ACCORDANCE WITH TM 10-8340-224-13.

DLA TROOP SUPPORT MAY ELECT TO PERFORM PHYSICAL TESTING SPECIFIED IN

SECTION 4.0 VERIFICATION OF MIL-PRF-44271C AS PART OF THE FA TESTING.

DPSCM4155.3 REQUIREMENTS SHALL BE MAINTAINED FOR COMPONENT

CERTIFICATION AND CERTIFICATE OF COMPLIANCE. FABRICS REQUIRED TO BE

SOURCE SAMPLED SHALL INCLUDE ALL APPLICABLE CHARTERISTICS AND TEST

METHODS EQUAL TO THE COMPONENT SPECIFICATIONS IDENTIFIED IN THE

“HISTORICAL TECHNICAL DATA FOR REFERENCES PURPOSES ONLY” COMPONENT.

ALL FABRIC LOT RELEASE TESTING PROCEDURES ARE APPLICABLE.

SOURCES OF COMPONENT MATERIALS SHALL BE IDENTIFIED, INCLUDING

APPLICABLE SPECIFICATIONS, AND SHALL NOT BE CHANGED THROUGHOUT THE

LIFE OF THE CONTRACT WITHOUT REQUEST AND APPROVAL BY THE DSCP

CONTRACTING OFFICER THROUGH MODIFICATION TO THE CONTRACT.

ADDITIONAL QUALITY ASSURANCE REQUIREMENTS

FABRIC TEST REPORTS AND COMPONENT CERTIFICATIONS IN ACCORDANCE WITH

DPSCM-4155.3 IS REQUIRED WITH THE FIRST ARTICLE AND ALL CONTRACT

COMPONENT LOTS.

A PROCESS ORIENTED QUALITY PLAN IS REQUIRED FOR THIS CONTRACT: NO

SPECIFIC OR CERTIFIED GOVERNMENT, ANSI, ASTM OR ISO QUALITY ASSURANCE

PLAN IS REQUIRED BUT SUCH PLANS MAY BE FOUND TO BE ACCEPTABLE FOR

CONTROL REQUIREMENTS.

A DETAILED QUALITY ASSURANCE PLAN SHALL INCLUDE AT MINIMUM THE

FOLLOWING ELEMENTS:

A) IN-PROCESS INSPECTION FOR ALL INTEROPERABLE MEASUREMENTS IS

REQUIRED.

A PLAN IS REQUIRED FOR ALL PROCESSES, RESULTING IN PARTS THAT POSSESS

INTEROPERABLE DIMENSIONS, I.E. ANY COMPONENT LENGTH, WIDTH OR

LOCATION THAT WILL INTERFACE WITH ANOTHER COMPONENT DURING

ASSEMBLY OR OPERATION BY THE END USER. REPRESENTATIVE EXAMPLES OF

INTEROPERABILITY ARE: THE DIMENSION OF THE EAVE LINE GROMMET TO THE

GROUND LINE, OR RIDGE LINE GROMMET TO THE EAVE LINE GROMMET THAT

WILL INTEROPERATE WITH THE TENT FRAME, OR THE LOCATION OF THE BECKET

LACES WHICH INTEROPERATING WITH THE LACING GROMMETS.

ANY INSPECTION METHOD MUST TAKE INTO ACCOUNT THE FOLLOWING THREE

UNSPECIFIED VARIABLES:

TAKE-UP, BUILD-UP OF TOLERANCES AND OPPOSING TOLERANCES

1. TAKE-UP. TAKE-UP FROM JOINING SEAMS CAUSES DISTORTIONS IN THE

GEOMETRY OF THE END ITEM COMPONENT.

RATIONAL: ALL SPECIFIED INDIVIDUAL0 DIMENSIONS CAN BE WITHIN

TOLERANCE, I.E. PERIMETER EDGE MEASUREMENTS, HOWEVER, WITH THE

COMPILATION OF EXCESS TAKE-UP FROM SEAMING AND THE ATTACHMENT OF

COMPONENT PARTS, THE CUSTOMER WOULD RECEIVE A COMPONENT INCAPABLE

OF CORRECTLY FITTING, AS DESIGNED, OVER THE TENT FRAME. EVERY STITCH

CREATES IT'S OWN SMALL PUCKER WITH THOUSANDS OF STITCHES FROM

JOINING SEAMS, ATTACHING WINDOWS, VENTS, FLAPS, ADAPTERS ECT. THE

UNMEASURED CENTER OF THE PANEL PULLS THE PERIMETER INWARD.

METHOD: ACCEPTABLE METHODS FOR DETERMINING THIS CONDITION MUST

INCLUDE THE MEASUREMENT OF ALL THE INTEROPERABLE POINTS

SIMULTANEOUSLY. IF A GAUGE OR JIG DEVICE IS USED THE APPARATUS MUST

ACCOUNT FOR ALL APPLICABLE TOLERANCES. A GOVERNMENT QUALITY

ASSURANCE SPECIALIST SHALL VERIFY THE APPARATUS FOR ACCURACY AGAINST

THE APPROVED PDM BY THE DIRECTION OF THE CONTRACTING OFFICER. 100

PERCENT IN-PROCESS INSPECTION IS REQUIRED. THE END ITEM LOT SAMPLE

UNITS SHALL BE INSPECTED WITH THIS GAUGE.

2. BUILD-UP OF TOLERANCES. AREAS REQUIRED FOR IN-PROCESS INSPECTIONS

SHALL ALSO INCLUDE PROCESSES THAT THAT CAN BE AFFECTED BY A BUILD-UP

OF TOLERANCES. AN EXAMPLE IS BECKET AND GROMMET INTEROPERABLE

LOCATIONS.

RATIONAL: IF A MAXIMUM TOLERANCE IS USED BETWEEN EVERY GROMMET

SPACE AND A MINIMUM TOLERANCE IS USED FOR THE EAVE TO RIDGE GROMMET

OR EAVE-LINE GROMMET TO GROUND-LINE GROMMET, THE SPACING OF THE

LAST GROMMET TO THE EAVE-LINE GROMMET WOULD NOT BE UNIFORM. THIS

MAY BE FURTHER COMPLICATED IF THE NEXT TENT SECTION IS ON THE

MAXIMUM SIDE OF THE TOLERANCES.

3. OPPOSING TOLERANCES. OPPOSING TOLERANCES SHALL ALSO BE

EXAMINED. IN-PROCESS INSPECTIONS TO CONTROL THIS CONDITION ARE

REQUIRED.

RATIONALE: FOR EXAMPLE, IF A MINIMUM TOLERANCE IS TAKEN BETWEEN THE

EAVE TO RIDGE AND A MAXIMUM FOR THE LENGTH OF THE WEATHER SEAL FLAP

PLUS, A MAXIMUM FOR THE PLACEMENT TO ATTACH THE FLAP FROM THE RIDGE

LINE, THE FLAP WILL COVER THE EAVE GROMMET. FLAPS FOR THE STOVEPIPE,

WINDOW OR VENTS MANUFACTURED TO THE MINIMUM AND OPENINGS MADE TO

THE MAXIMUM WILL ALSO RESULT IN POOR WORKMANSHIP.

B) RISK CLASSIFICATION ASSESSMENT

QUALITY ASSURANCE PLANS SHALL ACCOUNT AND ASSESS THE PROCESS RISK

FOR EACH PROCESS. CONSIDERATION FOR CLASSIFYING RISKS OF A PROCESS

INCLUDES THE PROCESSES SOPHISTICATION, PROCESS STABILITY, AND

PROCESSES PRODUCING INTEROPERABILITY COMPONENTS.

CONTROL OF PRODUCT QUALITY IS DEPENDENT ON IDENTIFYING THE FOLLOWING

CLASSIFICATIONS:

LOW RISK: PROCESSES YIELDING PRODUCTS WITH SMALL IMPACT ON THE

FUNCTIONALITY OF THE END ITEM. CONFIDENCE IS ESTABLISHED FOR THESE

IDENTIFIED PROCESSES BY QUALITY DATA COLLECTION FOR PERIODIC

VERIFICATION AGAINST THE CONTRACTOR’S SPECIFICATIONS

MODERATE RISK: USE THIS CLASSIFICATION WHEN A PROCESS YIELDING

PRODUCTS THAT CANNOT BE CLASSIFIER AS LOW OR HIGH RISK OR CONTAINS

HIDDEN OPERATIONS. CONSIGNORS PRODUCT VERIFICATION AND DATA

COLLECTION SHALL BE PERFORMED UNTIL THE PROCESS CAN BE PROVED TO BE

IN CONTROL.

HIGH RISK: USE WHEN THE PROCESS PERFORMANCE IS CRITICAL TO THE

PERFORMANCE, OR THE PROCESS YIELDS COMPONENTS THAT MUST

INTEROPERATE. SOPHISTICATED PROCESSES SUCH AS HEAT SEALED SEAMS

THAT CAN RESULT IN CATASTROPHIC END ITEM FAILURE WHERE

ENVIRONMENTAL CONDITIONS AFFECT THE PROCESS OUTPUT SHALL BE

CONSIDERED HIGH RISK. INTENSIFIED PRODUCT AUDITS SHALL BE USED TO

VERIFY THE CONTROL OF THE PROCESS.

RECLASSIFICATION TO A LOWER RISK CATEGORY OF ANY PROCESS IS PERMITTED

AFTER THE IN-PLANT GOVERNMENT QUALITY REPRESENTATIVE HAS PROOFED

THE PROCESS AND AGREES THAT THE PROCESS IS IN CONTROL AND

CONFIDENCE IN THE PROCESS IS ESTABLISHED. RECLASSIFICATION TO A

HIGHER RISK CATEGORY IS REQUIRED WHEN A GOVERNMENT PRODUCT AUDIT

IDENTIFIES THAT A PROCESS IS PRODUCING A RUNNING NONCONFORMANCE OR

DEPARTURE.

C) DEFECT CLASSIFICATION AND QUALITY AUDIT CRITERIA

A. THE CONTRACTORS PROPOSED QUALITY ASSURANCE PLAN MUST INCLUDE A

DETAILED LIST OF END ITEM VISUAL DEFECTS, PACKAGING NONCONFORMITIES

AND LOT ACCEPTANCE CRITERIA INCLUDING ANY ACCEPTABLE QUALITY LEVELS.

RECOMMENDED DEFECTS WITH RELATION TO SEVERITY ARE LISTED BUT NOT

LIMITED TO THE FOLLOWING:

1. MAJOR DEFECTS: ANY HOLE, CUT, TEAR; COLOR NOT AS SPECIFIED; OPEN

SEAMS; LOOSE THREAD TENSION RESULTING IN LOOSE SEAMS; ANY MATERIAL

DEFECTS, DISTORTED PARTS OR POOR WORKMANSHIP; ANY COMPONENT PART

OMITTED; LABEL MISSING, INCORRECT, OR ILLEGIBLE; MEASUREMENT NOT AS

SPECIFIED

2. MINOR DEFECTS ANY PART SHADED: ANY SPOT OR STAIN (OUTSIDE); RAW

EDGES (ON NON-COATED WOVEN CLOTHS); THREAD ENDS NOT REMOVED, BAR

CODE OMITTED OR NOT READABLE BY SCANNER; BAR CODE NOT VISIBLE ON

FOLDED, PACKAGED ITEM; BARCODE CAUSES DAMAGE TO THE ITEM; ANY ITEMS

NOT PACKAGED IN ACCORDANCE WITH THE CONTRACT OR CONTRACTORS

SPECIFICATIONS.

B. RESPONSIBILITY FOR INSPECTION. THE CONTRACTOR IS RESPONSIBLE FOR

THE PERFORMANCE OF ALL INSPECTION, EXAMINATION, AND TEST

REQUIREMENTS SPECIFIED HEREIN AND IN THE SITED SPECIFICATIONS. THE

GOVERNMENT RESERVES THE RIGHT TO PERFORM ANY OF THE INSPECTIONS,

EXAMINATIONS AND TESTS AS DEEMED NECESSARY TO ENSURE SUPPLIES AND

SERVICES CONFORM TO PRESCRIBED REQUIREMENTS.

-D) TESTING

LOT INSPECTION IN ACCORDANCE WITH THE "AMERICAN NATIONAL STANDARDS

INSTITUTE (ANSI) ANSI/ASQC Z1.4 SAMPLING PROCEDURES AND TABLES FOR

INSPECTION BY ATTRIBUTES IS REQUIRED. LOT SIZES SHALL BE EXPRESSED IN

UNITS OF COMPLETELY FABRICATED TENTS. A CONTRACTOR DEVELOPED TABLE

OF DEFECTS ALONG WITH A SAMPLING PLAN WITH ACCEPTABLE QUALITY LEVELS

FOR:

1. END ITEM VISUAL EXAMINATION

2. END ITEM DIMENSIONAL AND INTEROPERABLE

3. END ITEM TESTING

4. PACKAGING

THE CONTRACTOR SHALL CERTIFY AND MAINTAIN SUBSTANTIATING EVIDENCE

THAT THE PRODUCT PRESENTED TO THE GOVERNMENT FOR ACCEPTANCE ARE

TENTS WHICH FULLY MEET AND COMPLY WITH THE GOVERNMENT'S

PERFORMANCE SPECIFICATION REQUIREMENTS, THE PRODUCERS

SPECIFICATIONS AND DRAWINGS, STANDARDS, AND QUALITY ASSURANCE

PRACTICES AND THAT WHICH CONFORM TO THE QUALITY STANDARDS AGREED

TO AT THE TIME OF CONTRACT AWARD. END ITEMS SHALL BE EXAMINED AS

CONTRACTUALLY SPECIFIED FOR ALL DEFECTS AND IN ACCORDANCE WITH THE

ACCEPTABLE QUALITY LEVEL AND DEFECT CRITERIA IN THIS CONTRACTS

APPROVED QUALITY ASSURANCE PLAN.

RESPONSIBILITY OF INSPECTION. THE CONTRACTOR IS RESPONSIBLE FOR THE

PERFORMANCE OF ALL INSPECTION, EXAMINATION, AND TEST REQUIREMENTS

SPECIFIED HEREIN AND IN THE SITED SPECIFICATIONS AND CONTRACT. THE

GOVERNMENT RESERVES THE RIGHT TO PERFORM ANY OF THE INSPECTIONS,

EXAMINATIONS AND TESTS AS DEEMED NECESSARY TO ENSURE SUPPLIES AND

SERVICES CONFORM TO PRESCRIBED REQUIREMENTS

APPLICABLE DOCUMENTS:

THE FOLLOWING LIST OF DOCUMENTS IS APPLICABLE TO THIS PROCUREMENT:

DEPARTMENT OF DEFENSE INDEX OF SPECIFICATIONS AND STANDARDS. PART

I AND II, JULY 2000 AND SUPPLEMENT, MARCH 2000.

SPECIFICATIONS

FEDERAL

A-A-55634A COMMERICAL ITEM DESCRIPTION, ZIPPERS

(FASTENERS, SLIDE INTERLOCKING) DATED 23 MARCH,

MILITARY

MIL-C-43256D NOT 1 MILITARY SPECIFICATION CORD, FIBROUS, POLYESTER,

SOLID BRAID DATED 16 JUNE, 1997 IS INACTIVE FOR NEW

DESIGN AND IS NO LONGER USED EXCEPT FOR

REPLACEMENT PURPOSES.

MIL-R-24049B MILITARY SPECIFICATION ROPE, POLYPROPYLENE DATED 14

JUNE, 1991.

MIL-DTL-32072 THREAD, POLYESTER DATED 08 JAN 2002 SUPERSEDING

V-T-285F JANUARY 03, 1991

MIL-DTL-32075 DATED 17 OCTOBER 2000

LABEL: FOR CLOTHING, EQUIPAGE, AND TENTAGE,

(GENERAL USE) SUPERSEDING DDD-L-20 DATED

MARCH 30, 1990.

MIL-DTL-53039C DATED 19 FEBRUARY 2009

COATING, ALIPHATIC POLYURETHANE, SINGLE

COMPONENT,

CHEMICAL AGENT RESISTANT

MIL-PRF-20696F CLOTH, WATERPROOF, WEATHER RESISTANT, DATED

2 SEPT 1997.

UNITED STATES INDUSTRIAL FABRICS INSTITUTE (USIFI) CLOTH

SPECIFICATIONS USIFI-PRF-44103 AND USIFI-PRF-20696 SHALL BE USED IN

PREFERENCE TO MIL-PRF-44103D AND MIL-PRF-20696F

USIFI - UNITED STATES INDUSTRIAL FABRICS INSTITUTE, A DIVISION OF IFAI

1801 COUNTY ROAD B WEST

ROSEVILLE, MN 55113

http://www.usifi.com

INTERIM CHANGES TO MIL-PRF-20696F:

PAGE 4, PARAGRAPH 3.7, TABLE I REQUIREMENTS: DELETE ALL REQUIREMENTS

FOR WEIGHT AND SUBSTITUTE THE FOLLOWING UNDER THE APPROPRIATE

COLUMN:

TYPE I

CLASS 1 2 3

"WEIGHT OZ/YD2 (MAX) 9.0 10.0 11.5

TYPE II & IV III

CLASS 1 2 3 5

17.0 19.0 19.0 13.0"

UNDER REQUIREMENTS FOR FLAME RESISTANCE (MAX), AFTER FLAME AND CHAR

LENGTH, DELETE "10" AND "3.5" FROM THE TYPE II & IV CLASS 1 COLUMN AND

INSERT UNDER TYPE I CLASS 3 COLUMN. UNDER REQUIREMENTS FOR FLAME

RESISTANCE (MAX), AFTER FLAME AND CHAR LENGTH, DELETE "10" AND "3.5"

FROM TYPE III CLASS V COLUMN AND INSERT UNDER TYPE II & IV, CLASS 3

COLUMN.

PAGE 5, AFTER PARAGRAPH 3.8 ADD THE FOLLOWING: "3.9 LENGTH AND PUT-UP.

UNLESS OTHERWISE SPECIFIED (SEE 6.2), THE CLOTH SHALL BE FURNISHED IN

ROLLS CONTAINING 50 TO 65 YARDS. NO ROLL SHALL CONTAIN MORE THAN

THREE PIECES AND NO SINGLE PIECE SHALL BE LESS THAN 10 YARDS IN

LENGTH."

PAGE 5, PARAGRAPH 4.3.2.1 YARD BY YARD EXAMINATION: AT THE END OF

PARAGRAPH, ADD THE FOLLOWING: "THE NUMBER OF ROLLS FROM WHICH THE

SAMPLE YARDAGE IS TO BE SELECTED SHALL BE IN ACCORDANCE WITH THE

FOLLOWING TABLE:

LOT SIZE (YARDS) SAMPLE SIZE (ROLLS)

UP TO 1200 INCLUSIVE 1/ 3

1201 UP TO AND INCLUDING 3200 5

3201 UP TO AND INCLUDING 10,000 8

10,001 UP TO AND INCLUDING 35,000 13

35,001 UP TO AND INCLUDING 150,000 20

150,001 AND OVER 32

1/ IF A LOT CONTAINS FEWER THAN THREE ROLLS, EACH ROLL IN THE LOT SHALL

BE EXAMINED."

THE INSPECTION LEVEL SHALL BE II AND THE ACCEPTABLE QUALITY LEVEL (AQL),

EXPRESSED IN TERMS OF DEFECTS PER HUNDRED UNITS, SHALL BE 2.5 FOR

MAJOR DEFECTS AND 6.5 FOR TOTAL (MAJOR AND MINOR COMBINED) DEFECTS.

MIL-DTL-43002E SHIELD, STOVEPIPE, TENT, NONMETALLIC

14 SEPTEMBER, 2000

MIL-PRF-44103D CLOTH, FIRE, WATER AND WEATHER RESISTANT, DATED

19 NOVEMBER, 1996.

UNITED STATES INDUSTRIAL FABRICS INSTITUTE (USIFI) CLOTH

SPECIFICATIONS USIFI-PRF-44103 AND USIFI-PRF-20696 SHALL BE USED IN

PREFERENCE TO MIL-PRF-44103D AND MIL-PRF-20696F.

USIFI - UNITED STATES INDUSTRIAL FABRICS INSTITUTE, A DIVISION OF IFAI

1801 COUNTY ROAD B WEST

ROSEVILLE, MN 55113

http://www.usifi.com

MIL-DTL-44258B ELECTRICAL DISTRIBUTION ASSEMBLIES FOR

TENT, EXTENDABLE, MODULAR, PERSONNEL (TEMPER)

NOTICE 2, 21 JANUARY, 2009.

MIL-DTL-44285A DOORS, DOUBLE BUMP THROUGH, 9 MARCH, 2000

MIL-C-53004B MILITARY SPECIFICATION CAMOUFLAGE SCREENING

SYSTEMS, MODULAR, LIGHTWEIGHT, SYNTHETIC,

WOODLAND, DESERT AND SNOW 18 JULY, 1997.

MIL-DTL-53039C COATING, ALIPHATIC POLYURETHANE, SINGLE

COMPONENT, CHEMICAL AGENT RESISTANT, DATED

19 FEBRUARY, 2009

MIL-PRF-44259E LIGHT SET, PORTABLE, FLUORESCENT, 29 JUNE, 2009

DPSCM-4155.3 QUALITY SYSTEMS REQUIREMENTS DATED NOVEMBER

03, 1997

MIL-I-45208A INSPECTION SYSTEMS REQUIREMENTS,

DATED 12/16/63; AM. 1, 7/24/81

NOTE: MIL-I-45208 HAS BEEN CANCELED: USE THE INTERNATIONAL

STANDARDS ISO 9002 OR ANSI/ASQC Q9002 IN PREFERANCE TO THE MIL-I-

45208

HIGHER LEVEL INSPECTION SYSTEM: THE INSPECTION SYSTEM(S) MUST BE

SUBMITTED WITH YOUR BID PROPOSAL FOR EVALUATION AND APPROVAL BY

DLA TOOP SUPPORT CONTRACTING OFFICER. INSPECTION SYSTEM(S)

COMPLIANT/BUT ARE NOT LIMITED TO THE INTERNATIONAL STANDARDS ISO

9002 OR ANSI/ANQC Q9002

MIL-L-1709E LINE, TENT, 10 AUGUST, 1989

"INTERIM CHANGES TO MIL-L-1709E:

THE USE OF MANILA LINES HAS BEEN DISCONTINUED. LINES IN TYPES SPECIFIED

SHALL BE FABRICATED FROM ROPE, POLYPROPYLENE, COLOR BLACK, IN

ACCORDANCE WITH MIL-R-24049B, DATED 14 JUNE 1991, OR BRAIDED

POLYESTER CORD, COLOR BLACK, IN ACCORDANCE WITH MIL-C-43256D, DATED 2

JULY 1991. THE ALTERNATE LINES SHALL BE OF THE SAME DIAMETER AS THE

SPECIFIED MANILA LINES. MINIMUM BREAKING STRENGTH OF THE ALTERNATE

LINES SHALL BE EQUAL TO OR GREATER THAN THE SPECIFIED MANILA LINES.

POLYESTER LINES MAY BE KNOTTED TO THE SAME DIMENSION AS THE SPECIFIED

SPLICE. THE KNOT SHALL HAVE THE SAME FUNCTION AS THE REPLACED SPLICE

AND SHALL NOT INTERFERE WITH OPERATION OF THE TENT SYSTEM. ALL LINES

SHALL INTEROPERATE WITH THE TENT SLIP OR GROMMET EQUALLY AS THE

REPLACED MANILA LINE."

MIL-P-501P MILITARY SPECIFICATION PIN, TENT, METAL, DATED 01

MARCH 1991

MIL-P-2383H NOT 1 MILITARY SPECIFICATION PINS, TENT, WOOD, DATED 11

ARRIL 1994

MIL-S-1734J SLIPS, TENT LINE, 30 JANUARY, 2002 SUPERSEDING

MIL-S-1734H DATED 06 DECEMBER, 1984.

NOTE: THE BELOW CHANGES TO THE MIL-S-1734H NEED TO BE COMPLIED

WITH IN CONJUCTION WITH THE MIL-S-1734J, SLIPS, TENT LINE, 30 JANUARY,

2002.

MIL-S-1734H SLIPS, TENT LINE

INTERIM SPECIFICATION CHANGES TO

MIL-S-1734H:

PARA. 1.2, AFTER TYPE II, DELETE “CASTING” AND SUBSTITUTE “INJECTION

MOLDED”.

PARA. 2.1, UNDER “SPECIFICATION, FEDERAL”, DELETE “QQ-M-38, QQ-M-55, QQ-

M-56” AND TITLES; UNDER “STANDARDS”, ADD “FED-STD-595-COLORS”.

PARA. 2.2, UNDER “ASTM”, DELETE “B94 AND TITLE”; SUBSTITUTE “D4066-NYLON

INJECTION MOLDED AND EXTRUSION MATERIALS (PA).”

PARA. 3.2.1.3, DELETE IN ITS ENTIRETY.

PARA. 3.2.4, DELETE AND SUBSTITUTE: “3.2.4 ENAMEL. ENAMEL SHALL CONFORM

TO COMPOSITION G OR L OF TT-E-529 CAMOUFLAGE GREEN COLOR NO. 34094 OF

FED-STD-595.”

PARA. 3.3.2, DELETE AND SUBSTITUTE: “3.3.2 TYPE II. THE TYPE II TENT LINE SLIP

SHALL BE FABRICATED OF NYLON 6 WITH 30 PERCENT GLASS, CONFORMING TO

ASTM D 4066. MATERIAL SHALL CONTAIN AN ULTRAVIOLENT STABILIZER. CLEAN

UNBURNED MATERIAL IN THE FORM OF RUNNERS, OR FROM OTHER MOLDING OR

FINISHING OPERATIONS MAY BE GROUND AND MIXED WITH VIRGIN MATERIAL.

WHEN REGROUND MATERIAL IS MIXED WITH VIRGIN MATERIAL, IT SHALL NOT

EXCEED A LEVEL OF 20 PERCENT BY WEIGHT OF THE BLENDED MIXTURE. THE

SURFACE OF THE MOLDING SHALL BE FREE OF DIRT, DUST OF FOREIGN MATTER

INCLUSION. CAMOUFLAGE GREEN COLOR NO. 34094 OF FED-STD-595 SHALL BE

INCLUDED IN THE PLASTIC COMPOUND. NO FURTHER COLOR TREATMENT

REQUIRED.

PARA. 3.4.1, LINE 1 AND LINE 3, AFTER “OF THE” ADD, “TYPE I”.

MIL-STD-105E SAMPLING PROCEDURES AND TABLES FOR

INSPECTION BY ATTRIBUTES, 06 FEBRUARY, 2008

SUPERSEDING NOTICE 2 DATED 26 MARCH, 2001

MIL-STD-105E, DATED 10 MAY, 1989, IS HEREBY CANCELED. FUCTURE

ACQUISTIONS MAY REFER TO: MIL-STD-1916, “DOD PERFERRED METHODES FOR

ACCEPTANCE OF PRODUCT” , OR ANSI/ASQ Z1.4 SAMPLING PROCEDURES AND

TABLES FOR INSPECTION BY ATTRIBUTES

APPLICATION FOR COPIES SHOULD BE OBTAINED FROM:

AMERICAN SOCIETY FOR QUALITY CONTROL

600 NORTH PLANKINTON AVENUE,

MILWAUKEE, WI 53203

MIL-STD-129P DEPARTMENT OF DEFENSE STANDARD PRACTICE

MILITARY MARKING FOR SHIPMENT AND STORAGE

WITH CHANGE 4 DATED 19 SEPTEMBER, 2007

SUPERSEDING MIL-STD-129P WITH CHANGE 3 DATED

29 OCTOBER, 2004

MIL-STD-129P INTERIM CHANGES:

OMISSION OF MARKINGS ON EXTERIOR SHIPPING CONTAINERS OF ITEMS

IN THE DEFENSE LOGISTICS AGENCY TROOP SUPPORT, CLOTHING AND TEXTILE

(C&T) DIRECTORATE:

THE NOMENCLATURE AND MANUFACTURER'S NAME (WHEN THE NAME IDENTIFIES

THE MATERIAL) SHALL BE OMITTED FROM ALL EXTERIOR SHIPPING CONTAINERS

OF DLA TROOP SUPPORT C&T ITEMS, REGARDLESS OF MODE OF SHIPMENT.

IF THE MANUFACTURER'S NAME DOES NOT IDENTIFY THE MATERIAL AS BEING

CLOTHING, IT MAY REMAIN. NSNS SHALL BE SHOWN ON ALL SHIPPING

CONTAINERS OF C&T ITEMS, THE PACKING LIST SHALL BE PLACED INSIDE THE

LAST CONTAINER TO BE LOADED FOR EACH SHIP- MENT. THE WORDS "PACKING

LIST HERE" SHALL BE STENCILED, NOT

HAND LETTERED, ON THE CONTAINER.

MIL-HDBK-129 DEPARTMENT OF DEFENSE HANDBOOK MILITARY

MARKING NOTICE 1 DATED 15 DECEMBER, 2002.

MIL-HDBK-129, DATED 15 MAY 1997, IS HEREBY CANCELED. FUCTURE

ACQUISTIONS SHOULD REFER TO MIL-STD-129, MILITARY MARKING FOR

SHIPMENT AND STORAGE, STANDARD PRACTICE.

MIL-STD-130N DEPARTMENT OF DEFENSE IDENTIFICATION MARKING

OF U.S. MILITARY PROPERTY, DATED DECEMBER 2007

SUPERSEDING MIL-STD-130M WITH CHANGE 1, DATED

15 JUNE, 2007

MIL-STD-1472F DEPARTMENT OF DEFENSE DESIGN CRITERIA

STANDARD HUMAN ENGINEERING DATED 23 AUGUST

1999 CHANGE NOTICE 1, DATED 05 DECEMBER 2003

MIL-STD-810G DEPARTMENT OF DEFENSE TEST METHOD STANDARD

ENVIRONMENTAL ENGINEERING CONSIDERATIONS

AND LABORATORY TESTS DATED 31 OCTOBER, 2008

SUPERSEDING MIL-STD-810F DATED 01 JANUARY, 2000

MIL-STD-1366E DEPARTMENT OF DEFENSE INTERFACE STANDARD FOR

TRANSPORTABILITY CRITERIA, DATED 31 OCTOBER,

2006 SUPERSEDING MIL-STD-1366D DATED 18

DECEMBER, 1998

MIL-STD-1916 DEPARTMENT OF DEFENSE TEST METHOD STANDARD

DOD PREFERRED METHODS FOR ACCEPTANCE OF

PRODUCT DATED 01 APRIL, 1996

MIL-STD-2073-1E, STANDARD PRACTICE FOR MILITARY PACKAGING DATED

23 MAY, 2008

MIL-STD-731A MILITARY STANDARD QUALITY OF WOOD MEMBERS

FOR CONTAINERS AND PALLETS, DATED 03 MAY2002

SUPERSEDING NOTICE 2, DATED 05 AUG 1995

MIL-STD-731A DATED 04 OCTOBER, 1990 IS HEREBY CANCELLED AND

SUPERSEDED BY ASTM D6199 ENTIRELY.

MIL-STD-147E DEPARTMENT OF DEFENSE PALLETIZED UNIT LOADS

DATED 16 MAY, 2008 SUPERSEDING MIL-STD-147D

DATED 10 DECEMBER 1988

STANDARDS

FEDERAL

V-T-285F NOTICE 1 FEDERAL SPECIFICATION THREAD, POLYESTER, 03/APRIL,

V-T-285F FEDERAL SPECIFICATION THREAD, POLYESTER, 1/3/91 IS

HEREBY CANCELED AND REPLACED BY MIL-DTL-32072

THREAD, POLYESTER DATED 08 JAN 2002

INTERIM CHANGES TO V-T-285F:

PAGE 3, PARA. 2.2, AFTER LINE 8, ADD:

"AMERICAN ASSOCIATION OF TEXTILE CHEMISTS AND COLORISTS (AATCC)

AATCC 20 - FIBER ANALYSIS: QUALITATIV (APPLICATIONS FOR COPIES

SHOULD BE ADDRESSED TO AMERICAN ASSOCIATION OF TEXTILE

CHEMISTS AND COLORISTS (AATCC), P.O. BOX 12215, TRIANGLE PARK, NC

27709-2215)"

PAGE 12, PARA 4.2.3 - TABLE X, END ITEM TESTS, UNDER TEST METHOD

COLUMN, LINES 1 AND 2, DELETE "1600" AND SUBSTITUTE "AATCC 20".

PAGE 10, PARAGRAPH 4.2.1.1 THREAD ON HOLDER EXAMINATION LINE 7,

DELETE "1.5" AND "4.0" AND SUBSTITUTE "1.0" AND "2.5".

PAGE 11, PARAGRAPH 4.2.1.2 THREAD AS UNWOUND EXAMINATION, LINE 8,

DELETE "1.5" AND "4.0" AND SUBSTITUTE "1.0" AND "2.5".

PAGE 12, PARAGRAPH 4.2.3 END ITEM TESTING, LINE 8, DELETE "6.5" AND

SUBSTITUTE "4.0". APPROVED FINISHES FOR TY I CL 1 SUBCLASS B NON-

WICKING THREAD OF V-T-285; NW-1-AMERICAN THREAD CO. 90 PARK AVE,

NY, NY

10016; 33Q-COATS & CLARK INC, 430 PARK AVE, NY, NY 10022; ZS-

AMERICAN & EFIRD THREAD MILLS, MT. HOLLY, NC 28120; CBF-THREADS

INC, GASTONIA NC, 28053; WRE-THE LINEN THREAD CO, 12 MUNROE ST.,

WINSTED, CT 06098; 929-GUDEBROD BROS. SILK CO, 12 S. 12TH ST, PHILA.

PA 19107; AW-8-PREMIER THREAD CO, 345 THAMES ST, BRISTOL, RI 02809;

EINW-EDDINGTON THREAD MFG, CO. STREET ROADS, EDDINGTON, PA

19020; ST4-1-STD THREAD CONVERTING CO, PAWTUCKET, RI 02862; CE-T4-

JOHN C. MEYER THREAD CO. 62 FREMONT ST. WORCHESTER, MA 01603;

RTC-P-ROBINSON THREAD CO. INC. 19 MCKEON RD, WORCHESTER, MA

01610;AWSL-HOLLAND THREAD CO.INC. 423 MAIN ST., STROUDSBURG, PA

18360; ARCO-A.H. RICE CO. PITTSFIELD, MA 01201;SCB-SYNTHETIC

THREAD CO. 825 TWELFTH AVE, BETHLEHEM, PA 18018;

ASEW-HEMINWAY & BARTLETT MFG CO.WATERTOWN, CT, 06795

L-S-125B SCREENING, NONMETALLIC INSECT, 2/3/72

FED-STD-191A TEXTILE TEST METHODS, 7/29/78

CH NOT 1, 3/19/85; CH NOT 2,

8/15/85; CH NOT 3, 1/15/86;

CH NOT 4, 3/31/87; CH NOT 5,

12/28/89; CH NOT 6, 6/21/90

CHANGE NOTICE 7, DATED 8/9/2000:

FED-STD-191A NOTICE 1, DATED 21 JUNE 1990 IS

HEREBY INACTIVE FOR NEW DESIGN.

ADDITIONAL INFORMATION FOR FED-STD-191:

FED-STD-191A NOTICE 7, DATED AUGUST 9, 2000 IS HEREBY INACTIVE FOR NEW

DESIGN. WHEN NOT USING FED-STD-191, SEE INTERIM CHANGES TO END ITEM

SPECIFICATION FOR REPLACEMENT ASTM.

INTERIM CHANGES TO FED-STD-191A:

TEST METHOD 5202, PARA. 5.3, DELETE FIRST SENTENCE AND SUBSTITUTE: "THE

SPECIMEN SHALL BE CLAMPED FIRMLY, WITH ONE END FLUSH WITH THE OUTER

EDGE OF THE VISE, SUCH THAT ONE INCH OF SPECIMEN LIES WITHIN THE CLAMP

AND ONE INCH OF THE SPECIMEN EXTENDS BEYOND THE CENTER OF ROTATION

(FACE OF THE VISE), AND WITH THE LONG EDGE PARALLEL TO THE FACE OF THE

DIAL PLATE".

TEST METHOD 5309.1 ABRASION RESISTANT OF TEXTILE WEBBING. PAGE 1, PARA

4.1.2,LINE 4: DELETE "B-97" AND SUBSTITUTE "B-91".

THE FOLLOWING METHODS ARE IDENTIFIED AS SPECIFYING OZONE DEPLETING

SUBSTANCES: 1100, 1200, 1240, 1400, 1410, 1500, 1510,1520,1530, 1540, AND

1550. PARA 5.1 OF THESE TEST METHODS REQUIRE THE USE OF 1,1,1-

TRICHLOROETHANE, ALCOHOL OR ETHER. 1,1,1-TRICHLORETHANE IS AN OZONE

DEPLETING SUBSTANCE (METHYL CHLOROFORM) AND IS THEREFORE

PROHIBITED. THE USE OF EITHER ALCOHOL OR ETHER IS REQUIRED WHEN

THESE METHODS ARE IN BASIC OR ANY REFERENCED DOCUMENT.

METHOD 5202, STIFFNESS OF CLOTH, DIRECTIONAL; CANTILEVER BENDING

METHOD. PAGE 2, PARA. 5.3 DELETE FIRST SENTENCE AND SUBSTITUTE WITH

THE FOLLOWING: "THE…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .