Tech data window section temper tan.pdf
PDF 142 KB Posted
- Attached to
- Window Section, Tan, Temper
- Solicitation number
- 44597262
About this file
Item Description and Iterim Changes for the Window Section Tan Temperate
View the file
Other files
| File | Type | Posted |
|---|---|---|
| TDP.zip | ZIP file |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NSN(S) THIS PROCUREMENT
8340-01-213-6006
SECTION C - DESCRIPTION/SPECIFICATION
ITEM DESCRIPTION
WINDOW SECTION, DESERT/TROPICAL, DESERT TAN, US ARMY 686A
WINDOW SECTION, DESERT/TROPICAL, DESERT TAN, US ARMY 686A SHALL BE
IN ACCORDANCE WITH MILITARY SPECIFICATION MIL-PRF-44271, REVISION C,
DATED 16 SEPTEMBER, 2005, DRAWINGS 5-4-9755 SHEETS 1 AND 2 AND IN
ACCORDANCE WITH THE FOLLOWING PARTS BREAKDOWN:
NATIONAL STOCK
NUMBER
QUANTITY EACH
TENT
DESCRIPTION PART NUMBER
8340-01-213-6006 1 TENT SECTION DRAWING
5-4-9755
SHEET 11 AND 12
THE FOLLOWING VECP WILL ONLY APPLY TO THIS CONTRACT
WHEN CONVENTIONAL SEWN SEAMS ARE USED AND INDICATED IN
CLAUSE 52.248-9000/BSM# I48C01:
VECP 2002010 ½ INCH TURNUNDER IN-LIEU-OF 1 INCH TURNUNDER OF
THE BODY FABRIC FOR JOINING OF WINDOW SECTION
HALVES ON THE TEMPER TENT
DOOR/WINDOW SECTIONS (DESERT/TROPICAL) AND (TEMPERATE), SHALL BE IN
ACCORDANCE WITH THE FOLLOWING DRAWINGS:
DRAWING 5-4-3351 REV W, DOOR SECTION (DESERT/TROPICAL),
SHEET 1 AND 2, SECTION J-J
DRAWING 5-4-3352 REV V, WINDOW SECTION (DESERT/TROPICAL),
SHEET 1 AND 2, SECTION H-H
5-4-9755 SHEET 10 – THIS DRAWING IS CURRENTLY INACTIVE AND SHALL NOT BE
USED.
5-4-9755 SHEET 11 – THIS DRAWING IS CURRENTLY INACTIVE AND SHALL NOT BE
USED.
MIL-PRF-44271C TENT, EXTENDABLE, MODULAR,
PERSONNEL (TEMPER)
CHANGES FOR MIL-PRF-44271C:
ALL SEAMS ON THE TENT BODY THAT MAY BE EXPOSED TO ELEMENTS OF RAIN
OR SNOW SHALL BE DESIGNED TO PREVENT LEAKAGE OF WATER TO THE
INTERIOR OF THE TENT. THE USE OF THERMAL, ULTRASONIC, OR RADIO-
FREQUENCY (RF) WELDING, OR SIMILAR TECHNIQUES IS STRONGLY
RECOMMENDED TO PREVENT LEAKAGE. THE USE OF CONVENTIONAL SEWN
SEAMS, WHILE NOT RECOMMENDED, MAY BE ACCEPTABLE IF THE EXPOSED
SEWN SEAMS ARE AUGMENTED WITH HEAT-SEALED OR RF-WELDED
WATERPROOF TAPES TO PREVENT PENETRATION OF WATER THROUGH THE SEAM.
PARAGRAPH 1.1 CLASSIFICATION AND IDENTIFYING NUMBERS, CLASSES
UNDER CATORGORY CLASSES, CLASS 2, DELETE DESERT TAN NUMBER 459 AND
REPLACE WITH THE FOLLOWING: TAN 686A, CHIP NUMBER 33446, IN
ACCORDANCE WITH FEDERAL STANDARD 595C, COLORS USED IN GOVERNMENT
PROCUREMENT. THE COLOR REQUIREMENTS ARE DETAILED IN MIL-DTL-53039C
PARAGRAPH 3.3.1 TABLE 1. THE AVERAGE INFRARED REFLECTANCE SHALL BE 62
TO 72 PERCENT BETWEEN 720 TO 860 NANOMETERS. THIS NEW COLOR, TAN
686A, WILL REPLACE DESERT TAN 459.
ORDERING INFORMATION FOR COMMERCIAL CUSTOMERS: FAN DECKS, THE
COLOR BOOK, INDIVIDUAL COLOR CHIPS, SETS OF COLOR CHIPS ARE AVAILABLE
FOR SALE BY THE GENERAL SERVICES ADMINISTRATION AT THE FOLLOWING
ADDRESS:
-GENERAL SERVICES ADMINISTRATION PROPERTY MANAGEMENT
GSA/CO/3QSCB
490 L'ENFANT PLAZA EAST SW
SUITE 8214
WASHINGTON, DC 20407
-ORDERING INFORMATION FOR GOVERNMENT CUSTOMERS: INDIVIDUAL COLOR
CHIPS, COLOR BOOK, AND SETS OF COLOR CHIPS ARE AVAILABLE AT SAME
ADDRESS AS ABOVE. FAN DECKS ARE AVAILABLE VIA ROUTINE SUPPLY
CHANNELS UNDER NATIONAL STOCK NUMBER 7690-01-162-2210
THE NEW COLOR SHALL BE TAN 686A, CHIP NUMBER 33446, PER PARAGRAPH 6,
NOTES ON PAGE 4 OF FED-STD-595C, “THE CHIPS FOR CAMOUFLAGE COLORS
SHALL BE USED FOR GENERAL COLOR MATCHING PURPOSES ONLY, THE
SPECIFICATIONS FOR CAMOUFLAGE COATINGS CONTAIN REQUIREMENTS FOR
INFRARED REFLECTANCE WHICH MUST BE MET IN ADDITION TO COLOR. THE
COLOR CAEDS (CHIPS) FOR THE CAMOUFLAGE COLORS CONTAIN PIGMENTS
CHOSEN FOR THEIR SUITABILITY AND COMPATIBILITY WITH THE COLOR CARD
COATING AND, THEREFORE, HAVE DIFFERENT INFRARED REFLECTANCE
CHARACTERISTICS THEN THIS REQUIRED FOR CAMOUFLAGE COATINGS. MERELY
MATCHING THE COLOR CHIP FOR COLOR WILL NOT BE SUFFICIENT TO ASSURE
PRODUCT ACCEPTANCE BY THE CONTRACTING ACTIVITY. FOR FURTHER
INFORMATION, CONTACT FOR CAMOUFLAGE COLORS ONLY: U.S. ARMY
RESEARCH LABORATORY, CARC COMMODITY MANAGEMENT, ATTN: AMSRD-ARL-
WM-MC, ABERDEEN PROVING GROUND, MD 21005-5069.”
PARAGRAPH 3.5.1.1 END WALL
ADD THE FOLLOWING: "POTENTIAL WATER ENTRY ALONG THE TOP SEAM OF
EACH WINDOW SHALL BE DIVERTED BY A RAIN DIVERTER FLAP OR EQUIVALENT
FEATURE. A RAIN DIVERTER FLAP IS A STRIP OF FABRIC, IDENTICAL TO THE
FABRIC USED FOR THE EXTERIOR OF THE TENT, APPROXIMATELY 4 INCHES IN
HEIGHT, EXTENDING ACROSS THE TOP EDGE OF THE WINDOW OPENINGS AND AT
LEAST 2 INCHES ON EITHER SIDE OF THE WINDOW FLAP. THE RAIN DIVERTER
FLAP SHALL BE ATTACHED TO THE TENT BODY ALONG THE TOP EDGE BY USE OF
THERMAL, ULTRASONIC, OR RF WELDING TO PREVENT LEAKAGE. THE RAIN
DIVERTER FLAP SHALL BE POSITIONED SO THAT IT DIVERTS WATER OVER THE
TOP SEAM OF THE WINDOW AND SO THAT IT DOES NOT INTERFERE WITH
OPERATION OR REMOVAL OF THE WINDOW AND/OR WINDOW FLAP."
PARAGRAPH 3.5.1.2 WINDOW SECTION (TEMPERATE)
ADD THE FOLLOWING: "POTENTIAL WATER ENTRY ALONG THE TOP SEAM OF
EACH WINDOW SHALL BE DIVERTED BY A RAIN DIVERTER FLAP OR EQUIVALENT
FEATURE. A RAIN DIVERTER FLAP IS A STRIP OF FABRIC, IDENTICAL TO THE
FABRIC USED FOR THE EXTERIOR OF THE TENT, APPROXIMATELY 4 INCHES IN
HEIGHT, EXTENDING ACROSS THE TOP EDGE OF THE WINDOW OPENINGS AND AT
LEAST 2 INCHES ON EITHER SIDE OF THE WINDOW FLAP. THE RAIN DIVERTER
FLAP SHALL BE ATTACHED TO THE TENT BODY ALONG THE TOP EDGE BY USE OF
THERMAL, ULTRASONIC, OR RF WELDING TO PREVENT LEAKAGE. THE RAIN
DIVERTER FLAP SHALL BE POSITIONED SO THAT IT DIVERTS WATER OVER THE
TOP SEAM OF THE WINDOW AND SO THAT IT DOES NOT INTERFERE WITH
OPERATION OR REMOVAL OF THE WINDOW AND/OR WINDOW FLAP."
PARAGRAPH 3.5.1.3 WINDOW SECTION (DESERT/TROPICAL)
ADD THE FOLLOWING: "POTENTIAL WATER ENTRY ALONG THE TOP SEAM OF
EACH WINDOW SHALL BE DIVERTED BY A RAIN DIVERTER FLAP OR EQUIVALENT
FEATURE. A RAIN DIVERTER FLAP IS A STRIP OF FABRIC, IDENTICAL TO THE
FABRIC USED FOR THE EXTERIOR OF THE TENT, APPROXIMATELY 4 INCHES IN
HEIGHT, EXTENDING ACROSS THE TOP EDGE OF THE WINDOW OPENINGS AND AT
LEAST 2 INCHES ON EITHER SIDE OF THE WINDOW FLAP. THE RAIN DIVERTER
FLAP SHALL BE ATTACHED TO THE TENT BODY ALONG THE TOP EDGE BY USE OF
THERMAL, ULTRASONIC, OR RF WELDING TO PREVENT LEAKAGE. THE RAIN
DIVERTER FLAP SHALL BE POSITIONED SO THAT IT DIVERTS WATER OVER THE
TOP SEAM OF THE WINDOW AND SO THAT IT DOES NOT INTERFERE WITH
OPERATION OR REMOVAL OF THE WINDOW AND/OR WINDOW FLAP."
PARAGRAPH 3.5.1.4 DOOR SECTION (TEMPERATE)
ADD THE FOLLOWING: "POTENTIAL WATER ENTRY ALONG THE TOP SEAM OF
EACH WINDOW SHALL BE DIVERTED BY A RAIN DIVERTER FLAP OR EQUIVALENT
FEATURE. A RAIN DIVERTER FLAP IS A STRIP OF FABRIC, IDENTICAL TO THE
FABRIC USED FOR THE EXTERIOR OF THE TENT, APPROXIMATELY 4 INCHES IN
HEIGHT, EXTENDING ACROSS THE TOP EDGE OF THE WINDOW OPENINGS AND AT
LEAST 2 INCHES ON EITHER SIDE OF THE WINDOW FLAP. THE RAIN DIVERTER
FLAP SHALL BE ATTACHED TO THE TENT BODY ALONG THE TOP EDGE BY USE OF
THERMAL, ULTRASONIC, OR RF WELDING TO PREVENT LEAKAGE. THE RAIN
DIVERTER FLAP SHALL BE POSITIONED SO THAT IT DIVERTS WATER OVER THE
TOP SEAM OF THE WINDOW AND SO THAT IT DOES NOT INTERFERE WITH
OPERATION OR REMOVAL OF THE WINDOW AND/OR WINDOW FLAP."
PARAGRAPH 3.5.1.5 DOOR SECTION (DESERT/TROPICAL)
ADD THE FOLLOWING: "POTENTIAL WATER ENTRY ALONG THE TOP SEAM OF
EACH WINDOW SHALL BE DIVERTED BY A RAIN DIVERTER FLAP OR EQUIVALENT
FEATURE. A RAIN DIVERTER FLAP IS A STRIP OF FABRIC, IDENTICAL TO THE
FABRIC USED FOR THE EXTERIOR OF THE TENT, APPROXIMATELY 4 INCHES IN
HEIGHT, EXTENDING ACROSS THE TOP EDGE OF THE WINDOW OPENINGS AND AT
LEAST 2 INCHES ON EITHER SIDE OF THE WINDOW FLAP. THE RAIN DIVERTER
FLAP SHALL BE ATTACHED TO THE TENT BODY ALONG THE TOP EDGE BY USE OF
THERMAL, ULTRASONIC, OR RF WELDING TO PREVENT LEAKAGE. THE RAIN
DIVERTER FLAP SHALL BE POSITIONED SO THAT IT DIVERTS WATER OVER THE
TOP SEAM OF THE WINDOW AND SO THAT IT DOES NOT INTERFERE WITH
OPERATION OR REMOVAL OF THE WINDOW AND/OR WINDOW FLAP."
PARAGRAPH 3.5.1.7 INTERMEDIATE LINER (TEMPERATE)
ADD THE FOLLOWING: "THE CLEAR, FLEXIBLE WINDOW SHALL BE IN
ACCORDANCE WITH 5-4-9755, SHEET 12. (SEE ALSO CHANGES TO ICD 5-4-9755,
SHEET 37)"
PARAGRAPH 3.5.1.8 INTERMEDIATE LINER (DESERT/TROPICAL)
ADD THE FOLLOWING: "THE CLEAR, FLEXIBLE WINDOW SHALL BE IN
ACCORDANCE WITH 5-4-9755, SHEET 12. (SEE ALSO CHANGES TO ICD 5-4-9755,
SHEET 38)"
PARAGRAPH 3.5.1.9 END SECTION LINER (TEMPERATE AND DESERT/TROPICAL)
ADD THE FOLLOWING: "THE CLEAR, FLEXIBLE WINDOWS USED IN THE SIDE
WALLS OF THE LINER SHALL BE IN ACCORDANCE WITH 5-4-9755, SHEET 12. (SEE
ALSO CHANGES TO ICD 5-4-9755, SHEET 34 AND SHEET 35)"
PARAGRAPH 3.5.1.17 FLOOR 8’, INSULATED
IN THE SECOND TO LAST SENTENCE, DELETE “, AND THE R FACTOR SHALL BE 6.5
OR MORE”
PARAGRAPH 3.5.2.7 FABRIC WEIGHT
ON LINE 3, DELETE "4.0 OZ/SQ. YD." AND SUBSTITUTE "7.0 OZ/SQ. YD."
PARAGRAPH 3.5.1.22 VESTIBULE FLOOR, INSULATED
IN THE SECOND TO LAST SENTENCE, DELETE “, AND THE R FACTOR SHALL BE 6.5
OR MORE”
PARAGRAPH 3.7.3 IDENTIFICATION AND MARKING
ADD THE FOLLOWING:
TENTAGE LABELS FOR INDIVIDUAL COMPONENTS SHALL CONTAIN THE
FOLLOWING INFORMATION, IN ADDITION TO ANY INFORMATION SPECIFIED ON
THE COMPONENT'S INTERFACE CONTROL DRAWING:
"COMPONENT: [INSERT COMPONENT NOMENCLATURE]
COMPONENT NSN: [INSERT COMPONENT NSN]
CONTRACT #: [INSERT CONTRACT NUMBER]
[INSERT CONTRACTOR'S NAME, INCLUDING TRADEMARK OR CORPORATE LOGO
IF DESIRED]
CAGE CODE: [INSERT CODE]
QUANITY: [INSERT UNIT OF ISSUE QUANITY]
MANUFACTURE DATE: [INSERT DATE]
LOT NUMBER: [INSERT LOT NUMBER]"
THE IDENTIFICATION LABELS THAT SHALL BE PERMANENTLY ATTACHED TO THE
TENT FABRIC END SECTIONS AND STORAGE COVERS. THE LABEL SHALL BE A
MINIMUM OF 7 INCHES WIDE AND 7 INCHES HIGH WHITE FABRIC. THE LABEL
SHALL BE PRINTED IN A PERMANENT MARKING MEDIUM WITH THE FOLLOWING
NOMENCLATURE:
"COMPONENT: [INSERT COMPONENT NOMENCLATURE]
COMPONENT NSN: [INSERT COMPONENT NSN]
CONTRACT #: [INSERT CONTRACT NUMBER]
[INSERT CONTRACTOR'S NAME, INCLUDING TRADEMARK OR CORPORATE LOGO
IF DESIRED]
CAGE CODE: [INSERT CODE]
QUANITY: [INSERT UNIT OF ISSUE QUANITY]
MANUFACTURE DATE: [INSERT DATE]
LOT NUMBER: [INSERT LOT NUMBER]"
THE ATTACHMENT METHOD FOR LABELS AS FOLLOWS: “THE LABELS SHALL BE
PLACED CENTERED SEWN AND TO A SEPARATE PANEL OF BODY MATERIAL. THE
PANEL SHALL BE DIMENSIONED LARGER THAN THE LABELS TO ALLOW THE
EDGES OF THE PANEL TO BE THERMALLY SEALED TO THE TENT SECTION.
ADDITIONALLY IN PREFERENCE, ANY LABEL MY BE SECURED INO AN EXISTING
SEAM ALONG THE TOP EDGE IN LIEU OF STITCHING AROUND THE ENTIRE
PERMETER.
PARAGRAPH 4.5.2.11 LINER INSPECTION.
DELETE THE PARAGRAPH IN ITS ENTIRETY AND REPLACE WITH THE FOLLOWING:
"4.5.2.11 LINER INSPECTION. VISUALLY CONFIRM THAT THE LINER
CONFIGURATION AND INTERFACE DESIGN ARE ACCORDING TO ITS ICD. PERFORM
A TEAR STRENGTH TEST ON THE LINER ACCORDING TO ASTM-D2261. ONE
MAXIMUM PEAK LOAD SHALL BE RECORDED. THE MACHINE SHALL TEAR A
MINIMUM DISTANCE OF 3 INCHES. THE FORCE NECESSARY TO TEAR THE CLOTH
SHALL BE OBSERVED BY MEANS OF AN AUTOGRAPHIC RECORDING DEVICE. IN
CASE OF FAILURE BY YARN PULLOUT, RATHER THAN YARN BREAKAGE,
SPECIMENS SHALL BE CUT 8 BY 11 INCHES. PERFORM THE FOLLOWING FIELD
CLEANING TEST PROCEDURE ON THE LINER FABRIC:
1. DILUTE STANDARD HOUSEHOLD CHLORINE BLEACH (5.25 PERCENT SODIUM
HYPOCHLORITE ACTIVE INGREDIENT) BY MIXING 1 CUP OF BLEACH PER 1 GALLON
OF CLEAN WATER.
2. BRUSH OR SPRAY AFFECTED AREA WITH THE DILUTE BLEACH SOLUTION.
PREFERABLY, THE CLEANING IS DONE WHILE THE TENT IS ERECTED.
3. BRUSH THE AREA WELL TO REMOVE THE MILDEW AND/OR MOLD. LET STAND
UNTIL MILDEW AND/OR MOLD IS VISUALLY REMOVED.
4. RINSE THE BLEACHED AREA THOROUGHLY WITH WATER.
5. LET DRY COMPLETELY BEFORE FOLDING AND STORING.
ALL THE MATERIALS ARE AVAILABLE THROUGH GSA.
PRECAUTIONS FOR SAFE HANDLING AND USE OF BLEACH: BLEACH IS A
CORROSIVE MATERIAL THAT CAN CAUSE SKIN, EYE AND NOSE IRRITATION. AVOID
EYE/SKIN CONTACT AND INHALATION OF VAPOR MIST. THE FOLLOWING
PRECAUTIONS SHOULD BE TAKEN WHEN HANDLING: USE GLOVES, APRON,
GOGGLES OR SAFETY GLASSES. MANY COLORED FABRICS (GARMENTS) ARE
DAMAGED OR DISCOLORED BY BLEACH, INCLUDING THE BATTLEDRESS
UNIFORM. PLEASE USE APPOPRIATE PROTECTIVE CLOTHING WHEN HANDLING.
FOLLOW MANUFACTURER'S RECOMMENDED SAFETY PRECAUTIONS.
INSPECT THE LINER MATERIAL FOR ANY COLOR CHANGE, FADING, OR
DETERIORATION. NON-COMPLIANCE WITH THE ICD, ANY COLOR CHANGE OR
DETERIORATION FROM CLEANING, OR TEAR STRENGTH OF LESS THAN 17 POUNDS
SHALL BE RECORDED AS A FAILURE."
PARAGRAPH 4.5.2.12 PLENUM INSPECTION.
IN THE THIRD SENTENCE, DELETE THE PHRASE ENCLOSED IN PARENTHESES AND
REPLACE WITH THE FOLLOWING:
"(ACCORDING TO STEP 1 OF THE FIELD CLEANING TEST PROCEDURE IN
PARAGRAPH 4.5.2.11)"
ADD THE FOLLOWING PARAGRAPH:
"4.5.2.14 PARTITION AND MODESTY CURTAIN INSPECTION.
VISUALLY CONFIRM THAT THE PARTITION AND MODESTY CURTAIN
CONFIGURATION AND INTERFACE DESIGN ARE ACCORDING TO THEIR
RESPECTIVE ICD. PERFORM A TEAR STRENGTH TEST ON THE FABRIC ACCORDING
TO ASTM-D2261. ONE MAXIMUM PEAK LOAD SHALL BE RECORDED. THE
MACHINE SHALL TEAR A MINIMUM DISTANCE OF 3 INCHES. THE FORCE
NECESSARY TO TEAR THE CLOTH SHALL BE OBSERVED BY MEANS OF AN
AUTOGRAPHIC RECORDING DEVICE. IN CASE OF FAILURE BY YARN PULLOUT,
RATHER THAN YARN BREAKAGE, SPECIMENS SHALL BE CUT 8 BY 11 INCHES.
PERFORM THE FOLLOWING FIELD CLEANING TEST PROCEDURE ON THE FABRIC:
1. DILUTE STANDARD HOUSEHOLD CHLORINE BLEACH (5.25 PERCENT SODIUM
HYPOCHLORITE ACTIVE INGREDIENT) BY MIXING 1 CUP OF BLEACH PER 1 GALLON
OF CLEAN WATER.
2. BRUSH OR SPRAY AFFECTED AREA WITH THE DILUTE BLEACH SOLUTION.
PREFERABLY, THE CLEANING IS DONE WHILE THE TENT IS ERECTED.
3. BRUSH THE AREA WELL TO REMOVE THE MILDEW AND/OR MOLD. LET STAND
UNTIL MILDEW AND/OR MOLD IS VISUALLY REMOVED.
4. RINSE THE BLEACHED AREA THOROUGHLY WITH WATER.
5. LET DRY COMPLETELY BEFORE FOLDING AND STORING.
ALL THE MATERIALS ARE AVAILABLE THROUGH GSA.
PRECAUTIONS FOR SAFE HANDLING AND USE OF BLEACH: BLEACH IS A
CORROSIVE MATERIAL THAT CAN CAUSE SKIN, EYE AND NOSE IRRITATION. AVOID
EYE/SKIN CONTACT AND INHALATION OF VAPOR MIST. THE FOLLOWING
PRECAUTIONS SHOULD BE TAKEN WHEN HANDLING: USE GLOVES, APRON,
GOGGLES OR SAFETY GLASSES. MANY COLORED FABRICS (GARMENTS) ARE
DAMAGED OR DISCOLORED BY BLEACH, INCLUDING THE BATTLEDRESS
UNIFORM. PLEASE USE APPOPRIATE PROTECTIVE CLOTHING WHEN HANDLING.
FOLLOW MANUFACTURER'S RECOMMENDED SAFETY PRECAUTIONS.
INSPECT THE FABRIC FOR ANY COLOR CHANGE, FADING, OR DETERIORATION.
NON-COMPLIANCE WITH THE ICD, ANY COLOR CHANGE OR DETERIORATION FROM
CLEANING, OR TEAR STRENGTH OF LESS THAN 17 POUNDS SHALL BE RECORDED
AS A FAILURE."
DRAWINGS - CARTOONS - PATTERNS
INTERIM CHANGES TO 5-4-9755 ARE AS FOLLOWS:
GENERAL NOTES FOR 5-4-9755:
5-4-9755 DATED 20 SEPT 2005, WITH THE FOLLOWING CHANGES:
WHEREVER PRACTICAL, TENTAGE LABELS INDICATED ON THESE DRAWINGS
SHALL BE SEWN INTO AN EXISTING ADJACENT SEAM, PROVIDED THAT THE
VISIBILITY OF THE LABELS ON THE ERECTED TENT IS NOT OBSCURED.
5-4-9755 SHEET 1 - NO CHANGES
5-4-9755 SHEET 2 - NO CHANGES
5-4-9755 SHEET 3 - NO CHANGES
5-4-9755 SHEET 4 - NO CHANGES
5-4-9755 SHEET 5 - IN ZONE D8, DELETE "GOTHIC" AND REPLACE WITH "ARIAL".
TWO (2) "US" MARKINGS ARE ACCEPTABLE FOR EACH 16' FLY, IN LIEU OF THE
FOUR (4) MARKINGS SHOWN. THE TWO MARKINGS SHALL APPEAR ON OPPOSITE
SIDES OF THE RIDGE LINE ON THE ERECTED TENT, AND SHALL BE CENTERED
HORIZONTALLY AT THE CENTER LINE OF THE FLY.
TIE TAPES FOR THE STOVEPIPE FLAP SHALL BE INCORPORATED BOTH ON THE
OUTSIDE OF THE STOVEPIPE FLAP, AND ON THE OUTSIDE OF THE STOVEPIPE
ADAPTER PANEL (UNDER THE STOVEPIPE FLAP), SO THAT THE FLAP MAY BE
ROLLED UP AND SECURED WHEN STOVEPIPE IS PRESENT.
5-4-9755 SHEET 6 - IN ZONE E8, DELETE "GOTHIC" AND REPLACE WITH "ARIAL".
TIE TAPES FOR THE STOVEPIPE FLAP SHALL BE INCORPORATED BOTH ON THE
OUTSIDE OF THE STOVEPIPE FLAP, AND ON THE OUTSIDE OF THE STOVEPIPE
ADAPTER PANEL (UNDER THE STOVEPIPE FLAP), SO THAT THE FLAP MAY BE
ROLLED UP AND SECURED WHEN A STOVEPIPE IS PRESENT.
5-4-9755 SHEET 7 - MARK IN PERMANENT BLACK INK, WITH 1" HIGH ARIAL FONT
LETTERS, THE FOLLOWING INSTRUCTION:
"CLOSE SLIDE FASTENERS AND SNAPHOOKS BEFORE ERECTING"
THIS NOTATION SHALL BE CENTERED HORIZONTALLY ON THE OUTSIDE OF DOOR,
APPROXIMATELY 6" FROM LOWER EDGE OF DOOR. SEE DRAWING 5-4-9755
SHEET 13 FOR REFERENCE.
TIE TAPES FOR THE WINDOW FLAPS SHALL BE INCORPORATED BOTH ON THE
OUTSIDE OF THE WINDOW FLAP, AND ON THE OUTSIDE TOP EDGE OF THE
WINDOW SCREEN, SO THAT THE WINDOW FLAP MAY BE ROLLED UP REGARDLESS
OF WHETHER A REMOVABLE PLASTIC WINDOW PANE IS PRESENT.
5-4-9755 SHEET 8 - IN ZONE D6, DELETE "27" AND REPLACE WITH "28".
THE SIDE OF THE ADAPTER CONTAINING THE 14 #2 GROMMETS SHALL
INCORPORATE A 2" WIDE LOOP FASTENER TAPE ALONG THE INTERIOR EDGE IN
ORDER TO FACILITATE INTERFACE WITH THE DOUBLE-BUMP DOOR ASSEMBLY.
THE 2" WIDE LOOP FASTENER TAPE SHALL EXTEND APPROXIMATELY FROM THE
GROUND LINE TO THE 2" SLIT SHOWN IN VIEW G.
5-4-9755 SHEET 9 - IN SECTION A-A, ZONE C6, DELETE "36"L" AND REPLACE WITH
"18"L". OMIT THE TIE TAPE SHOWN ON THE INSIDE OF THE WINDOW PANE. IN
ZONE D7, RELOCATE THE FASTENER TAPE (LOOP) TO THE INSIDE OF THE WINDOW
PANE. IN ZONE B7, RELOCATE THE FASTENER TAPE (LOOP) TO THE INSIDE OF
THE WINDOW PANE, AND RELOCATE THE FASTENER TAPE (HOOK) TO THE
OUTSIDE OF THE WINDOW PANE.
IN SECTION B-B, ZONE A5, RELOCATE THE FASTENER TAPE (LOOP) TO THE INSIDE
OF THE WINDOW PANE, AND RELOCATE THE FASTENER TAPE (HOOK) TO THE
OUTSIDE OF THE WINDOW PANE.
5-4-9755 SHEET 10 - TIE TAPES FOR THE WINDOW FLAPS SHALL BE
INCORPORATED BOTH ON THE OUTSIDE OF THE WINDOW FLAP, AND ON THE
OUTSIDE TOP EDGE OF THE WINDOW SCREEN, SO THAT THE WINDOW FLAP MAY
BE ROLLED UP REGARDLESS OF WHETHER A REMOVABLE PLASTIC WINDOW PANE
IS PRESENT.
TIE TAPES FOR THE STOVEPIPE FLAP SHALL BE INCORPORATED BOTH ON THE
OUTSIDE OF THE STOVEPIPE FLAP, AND ON THE OUTSIDE OF THE STOVEPIPE
ADAPTER PANEL (UNDER THE STOVEPIPE FLAP), SO THAT THE FLAP MAY BE
ROLLED UP AND SECURED WHEN STOVEPIPE IS PRESENT.
5-4-9755 SHEET 11 - TIE TAPES FOR THE WINDOW FLAPS SHALL BE
INCORPORATED BOTH ON THE OUTSIDE OF THE WINDOW FLAP, AND ON THE
OUTSIDE TOP EDGE OF THE WINDOW SCREEN, SO THAT THE WINDOW FLAP MAY
BE ROLLED UP REGARDLESS OF WHETHER A REMOVABLE PLASTIC WINDOW PANE
IS PRESENT.
5-4-9755 SHEET 12 - DELETE THE BROKEN LINES THAT EXTEND FROM ZONE B6
THROUGH C6 AND FROM ZONE B2 THROUGH C2, AND REPLACE WITH SOLID
LINES. IN THE MAIN VIEW, THE LENGTH OF THE TIE TAPES SHALL BE 20". IN
SECTION A-A, ZONE C7, RELOCATE THE FASTENER TAPE (LOOP) TO THE INSIDE OF
THE WINDOW PANE. IN ZONE B7, RELOCATE THE FASTENER TAPE (LOOP) TO THE
INSIDE OF THE WINDOW PANE, AND RELOCATE THE FASTENER TAPE (HOOK) TO
THE OUTSIDE OF THE WINDOW PANE. IN SECTION B-B, ZONE A7, ADD FASTENER
TAPE (HOOK) TO THE OUTSIDE OF THE WINDOW PANE.
5-4-9755 SHEET 13 - NO CHANGES
5-4-9755 SHEET 14 - NO CHANGES
5-4-9755 SHEET 15 - THE SIDE OF THE ADAPTER CONTAINING THE 14 #2
GROMMETS SHALL INCORPORATE A 2" WIDE LOOP FASTENER TAPE ALONG THE
INTERIOR EDGE IN ORDER TO FACILITATE INTERFACE WITH THE DOUBLE-BUMP
DOOR ASSEMBLY. THE 2" WIDE LOOP FASTENER TAPE SHALL EXTEND
APPROXIMATELY FROM THE GROUND LINE TO THE 2" SLIT SHOWN IN VIEW D.
5-4-9755 SHEET 16 - THE VESTIBULE SHALL INCORPORATE TWO 2" WIDE LOOP
FASTENER TAPES ALONG THE INTERIOR EDGES OF THE GROMMET LINES (ZONES
G6-G7, AND C2-C3-C4) IN ORDER TO FACILITATE INTERFACE WITH THE DOUBLE-
BUMP DOOR ASSEMBLY. THE 2" WIDE LOOP FASTENER TAPES SHALL EXTEND
APPROXIMATELY FROM THE GROUND LINE TO THE #4 GROMMETS AT THE EAVE
OF THE VESTIBULE (ZONES C4 AND G5).
5-4-9755 SHEET 17 - NO CHANGES
5-4-9755 SHEET 18 - NO CHANGES
5-4-9755 SHEET 19 - NO CHANGES
5-4-9755 SHEET 20 - NO CHANGES
5-4-9755 SHEET 21 - NO CHANGES
5-4-9755 SHEET 22 - NO CHANGES
5-4-9755 SHEET 23 - NO CHANGES
5-4-9755 SHEET 24 - NO CHANGES
5-4-9755 SHEET 25 - NO CHANGES
5-4-9755 SHEET 26 - NO CHANGES
5-4-9755 SHEET 27 - NO CHANGES
5-4-9755 SHEET 28 - NO CHANGES
5-4-9755 SHEET 29 - NO CHANGES
5-4-9755 SHEET 30 - NO CHANGES
5-4-9755 SHEET 31 - NO CHANGES
5-4-9755 SHEET 32 - NO CHANGES
5-4-9755 SHEET 33 - IN ZONE F7, DELETE "25 1/2" AND REPLACE WITH "24". IN
ZONE E6, DELETE "32" AND REPLACE WITH "28". ADD THE FOLLOWING NOTE:
"THE END WALL LINER SHALL BE FITTED WITH TWO REMOVABLE WINDOW
ASSEMBLIES IN ACCORDANCE WITH 5-4-9755 SHEET 36."
5-4-9755 SHEET 34 - IN ZONE B7, DELETE "8'-- 1 1/2" " AND REPLACE WITH "8'-- 2
1/2" "
IN ZONE B7, DELETE "48 3/4" " AND REPLACE WITH "49 1/4" "
IN ZONE B5, DELETE "8'-1 1/2" " AND REPLACE WITH "8'-2 1/2" "
IN ZONE B5, DELETE "16-12" " AND REPLACE WITH "11" "
IN ZONE B5, DELETE "4'-9" OPENING " AND REPLACE WITH "5'-8" OPENING "
IN ZONE B5, DELETE "28-1/2" " AND REPLACE WITH "34" "
IN ZONE D5, DELETE "28-1/2" " AND REPLACE WITH "34" "
IN ZONE B3, DELETE "4'-11" " AND REPLACE WITH "6' "
ELIMINATE THE 4 STRAPS ALONG THE EDGE OF THE LINER IN ZONES H7, G7 AND
F7, AND WHERE THE SAME 4 STRAPS APPEAR ON THE OUTSIDE VIEW AT H4, G4
AND F4.
IN ZONE B6, DELETE "29X" AND REPLACE WITH "25X"
IN ZONE F8, CHANGE THE DIMENSION OF THE SLIT INDICATED AT THE RIDGE
LINE OF THE PANEL FROM 1" TO 2". THIS SLIT SHOULD EXTEND TO THE EDGE OF
THE FABRIC PANEL TO FACILITATE INTERFACE WITH THE ADJOINING PANEL.
5-4-9755 SHEET 35 - IN ZONE B7, DELETE "8'-- 1 1/2" " AND REPLACE WITH "8'-- 2
1/2" "
IN ZONE B7, DELETE "48 3/4" " AND REPLACE WITH "49 1/4" "
IN ZONE B5, DELETE "8'-1 1/2" " AND REPLACE WITH "8'-2 1/2" "
IN ZONE B4, DELETE "16-12" " AND REPLACE WITH "11" "
IN ZONE B5, DELETE "4'-9" OPENING " AND REPLACE WITH "5'-8" OPENING "
IN ZONE B5, DELETE "28-1/2" " AND REPLACE WITH "34" "
IN ZONE D4, DELETE "28-1/2" " AND REPLACE WITH "34" "
IN ZONE B3, DELETE "4'-11" " AND REPLACE WITH "6' "
ELIMINATE THE 4 STRAPS ALONG THE EDGE OF THE LINER IN ZONES H7, G7 AND
F7, AND WHERE THE SAME 4 STRAPS APPEAR ON THE OUTSIDE VIEW AT H4, G4
AND F4.
IN ZONE B6, DELETE "29X" AND REPLACE WITH "25X"
IN ZONE F8, CHANGE THE DIMENSION OF THE SLIT INDICATED AT THE RIDGE
LINE OF THE PANEL FROM 1" TO 2". THIS SLIT SHOULD EXTEND TO THE EDGE OF
THE FABRIC PANEL TO FACILITATE INTERFACE WITH THE ADJOINING PANEL.
5-4-9755 SHEET 36 - NO CHANGES
5-4-9755 SHEET 37 - IN ZONE B7, DELETE "8'-- 1 1/2" " AND REPLACE WITH "8'-- 3
1/2" "
IN ZONE B7, DELETE "48 3/4" AND REPLACE WITH "49 3/4"
IN ZONE B6, DELETE "38X" AND REPLACE WITH "30X"
IN ZONE B5, DELETE "8'-- 1 1/2" "AND REPLACE WITH "8'-- 3 1/2" "
IN ZONE B5, DELETE "16-12" " AND REPLACE WITH "11" "
IN ZONE B5, DELETE "4'-9" OPENING " AND REPLACE WITH "5'-8" OPENING "
IN ZONE B5, DELETE "28-1/2" " AND REPLACE WITH "34" "
IN ZONE D5, DELETE "28-1/2" " AND REPLACE WITH "34" "
IN ZONE B3, DELETE "4'-11" " AND REPLACE WITH "6' "
ELIMINATE THE 4 STRAPS ALONG THE EDGE OF THE LINER, IN ZONES H7, G7, AND
F7, AND WHERE THE SAME STRAPS APPEAR ON THE OUTSIDE VIEW IN H4, G4,
AND F4.
ELIMINATE THE 4 STRAPS ALONG THE EDGE OF THE LINER IN ZONES C6, D6, AND
E6, AND WHERE THE SAME STRAPS APPEAR ON THE OUTSIDE VIEW IN C5, D5,
AND E5. THE STRAP AT THE RIDGE LINE IN E6 SHALL REMAIN.
IN ZONE E6, CHANGE THE DIMENSION OF THE SLIT INDICATED AT THE RIDGE
LINE OF THE PANEL FROM 1" TO 2". THIS SLIT SHOULD EXTEND TO THE EDGE OF
THE FABRIC PANEL TO FACILITATE INTERFACE WITH THE ADJOINING PANEL.
5-4-9755 SHEET 38 - IN ZONE B7, DELETE "8'-- 1 1/2" " AND REPLACE WITH "8'-- 3
1/2" "
IN ZONE B7, DELETE "48 3/4" AND REPLACE WITH "49 3/4"
IN ZONE B6, DELETE "38X" AND REPLACE WITH "30X"
IN ZONE B5, DELETE "8'-- 1 1/2" "AND REPLACE WITH "8'-- 3 1/2" "
IN ZONE B4, DELETE "16-12" " AND REPLACE WITH "11" "
IN ZONE B5, DELETE "4'-9" OPENING " AND REPLACE WITH "5'-8" OPENING "
IN ZONE B5, DELETE "28-1/2" " AND REPLACE WITH "34" "
IN ZONE D4, DELETE "28-1/2" " AND REPLACE WITH "34" "
IN ZONE B3, DELETE "4'-11" " AND REPLACE WITH "6' "
ELIMINATE THE 4 STRAPS ALONG THE EDGE OF THE LINER, IN ZONES H7, G7, AND
F7, AND WHERE THE SAME STRAPS APPEAR ON THE OUTSIDE VIEW IN H4, G4,
AND F4.
ELIMINATE THE 4 STRAPS ALONG THE EDGE OF THE LINER IN ZONES C6, D6, AND
E6, AND WHERE THE SAME STRAPS APPEAR ON THE OUTSIDE VIEW IN C5, D5,
AND E5. THE STRAP AT THE RIDGE LINE IN E6 SHALL REMAIN.
IN ZONE E6, CHANGE THE DIMENSION OF THE SLIT INDICATED AT THE RIDGE
LINE OF THE PANEL FROM 1" TO 2". THIS SLIT SHOULD EXTEND TO THE EDGE OF
THE FABRIC PANEL TO FACILITATE INTERFACE WITH THE ADJOINING PANEL.
5-4-9755 SHEET 39 - THIS DRAWING IS CURRENTLY INACTIVE AND SHALL NOT BE
USED.
5-4-9755 SHEET 40 - THIS DRAWING IS CURRENTLY INACTIVE AND SHALL NOT BE
5-4-9755 SHEET 41 - THIS DRAWING IS CURRENTLY INACTIVE AND SHALL NOT BE
5-4-9755 SHEET 42 - THIS DRAWING IS CURRENTLY INACTIVE AND SHALL NOT BE
USED.
5-4-9755 SHEET 43 - THIS DRAWING IS CURRENTLY INACTIVE AND SHALL NOT BE
USED.
5-4-9755 SHEET 44 - THIS DRAWING IS CURRENTLY INACTIVE AND SHALL NOT BE
USED.
PLENUM ASSEMBLIES SHALL BE IN ACCORDANCE WITH THE FOLLOWING
DRAWINGS:
5-4-3614 REV F, DATED 2/10/00
5-4-3615 REV E, DATED 7/6/87
5-4-3616 REV C, DATED 3/23/99
5-4-3618 REV C, DATED 3/18/85
5-4-3619 REV E, DATED 7/6/87
5-4-3620 REV D, DATED 2/10/00
5-4-7970 DATED 8/14/98
5-4-7971 DATED 8/14/98
5-4-7972 DATED 8/14/98
5-4-7973 DATED 8/14/98
5-4-7974 DATED 8/14/98
5-4-7975 DATED 8/14/98
5-4-7976 DATED 8/14/98
5-4-7977 DATED 8/14/98
5-4-7978 DATED 8/14/98
5-4-7979 DATED 8/14/98
5-4-7980 DATED 8/14/98
5-4-7981 DATED 8/14/98
5-4-7982 DATED 8/14/98
5-4-7983 DATED 8/14/98
5-4-7984 DATED 8/14/98
PARTS LISTS:
PL5-4-3616 REV C, DATED 3/23/99
PL5-4-7970 DATED 8/14/98
5-4-9755 SHEET 45 - IN ZONE H3, DELETE "HOOK" AND REPLACE WITH "LOOP"
IN ZONE D2, DELETE "LOOP" AND REPLACE WITH "HOOK"
IN ZONE D3, DELETE "HOOK" AND REPLACE WITH "LOOP"
IN ZONE A2, DELETE "LOOP" AND REPLACE WITH "HOOK"
5-4-9755 SHEET 46 - NO CHANGES
5-4-9755 SHEET 47 - NO CHANGES
5-4-9755 SHEET 48 - IN ZONE G4, DELETE "HOOK" AND REPLACE WITH "LOOP"
IN ZONE F3, DELETE "HOOK" AND REPLACE WITH "LOOP"
IN ZONE C2, DELETE "LOOP" AND REPLACE WITH "HOOK"
5-4-9755 SHEET 49 - NO CHANGES
5-4-9755 SHEET 50 - NO CHANGES
5-4-9755 SHEET 51 - NO CHANGES
5-4-9755 SHEET 52 - IN ZONE H7, DELETE "GOTHIC" AND REPLACE WITH "ARIAL".
ADD THE FOLLOWING SENTENCE UNDER THE NOTES:
"NOMENCLATURES AND ANY OTHER MARKINGS SHALL BE SPECIFIED IN THE
CONTRACT OR PURCHASE ORDER."
5-4-9755 SHEET 53 - IN ZONE C5, DELETE "GOTHIC" AND REPLACE WITH "ARIAL".
ADD THE FOLLOWING NOTE:
"NOMENCLATURES AND ANY OTHER MARKINGS SHALL BE SPECIFIED IN THE
CONTRACT OR PURCHASE ORDER."
IN ZONE E6, DELETE "BOTH SIDES". ADD THE FOLLOWING NOTE: "THE LETTERS
"US" SHALL BE MARKED ON THE OUTSIDE OF THE COVER; THE CONTENTS SHALL
BE MARKED ON BOTH THE OUTSIDE AND THE INSIDE OF THE COVER. SEE 5-4-
3347 FOR GUIDANCE."
5-4-9755 SHEET 54 - IN ZONE B6, DELETE "GOTHIC" AND REPLACE WITH "ARIAL".
IN ZONE B2, DELETE 4" AND REPLACE WITH 6". THE TENTAGE LABEL SHALL BE
RELOCATED TO THE BOTTOM (CLOSED END) OF THE CONTAINER.
5-4-9755 SHEET 55 - IN ZONE B6, DELETE "GOTHIC" AND REPLACE WITH "ARIAL".
5-4-1 TENT, PIN, WOOD; REV. 16, 02/02/82
5-4-791 REV. F TENT, PIN, METAL 11/30/87
5-4-3358 ERECTION INSTRUCTIONS SH. 1 REV B, 4/2/85; SH. 2 REV
C, 9/5/85\
5-4-8489 TENT, EXTENDABLE, MODULAR, PERSONNEL (TEMPER) ASSEMBLY
COMPONENTS
SHEET 1, REV. C, 3/21/03
SHEET 2, REV. C, 3/21/03
SHEET 3, REV. C, 3/21/03
8-1-10 REV N SHIELD, STOVEPIPE, TENT, NONMETALIC 12/20/83
IMPORTANT NOTE:
ACCOMPANING DOCUMENTS INCLUDED IN THIS TECHNICAL DATA PACKAGE
LABELED “HISTORICAL TECHNICAL DATA FOR REFERENCES PURPOSES ONLY’”
MAY BE USED TO IDENTIFY THE TYPE, QUALITY, AND QUALITY OF MATERIALS AND
METHODS OF CONSTRUCTION THAT HAVE BEEN HISTORICALLY ACCEPTABLE IN
THE MANUFACTURE OF TEMPER TENT SYSTEMS AND COMPONENTS. THE
HISTORICAL DOCUMENTS ARE NOT TO BE USED FOR INSPECTION OR LOT
RELEASE PURPOSES UNLESS SPECIFICALLY APPROVED BY THE DLA TROOP
SUPPORT CONTRACTING OFFICER THROUGH MODIFICATION TO THE CONTRACT.
CONTRACTOR'S TECHNICAL DATA PACKAGE:
GOVERNMENT DRAWING 5-4-9755 IDENTIFIES COMPONENT INTERFACE CONTROL
REQUIREMENTS NECESSARY FOR INTEGRATION AND FACILITATION OF THE
DEVELOPED ITEM. 5-4-9755 DOES NOT IDENTIFY ALL NECESSARY DETAILED
MATERIAL REQUIREMENTS OR METHODS OF CONSTRUCTION. THE CONTRACTOR
SHALL DEVELOP AND DOCUMENT A TECHNICAL DATA PACKAGE (TDP) THAT
ENCOMPASSES THE REQUIREMENTS OF 5-4-9755 AND MIL-PRF-44271C. THE
CONTRACTOR'S TDP SHALL IDENTIFY, AT MINIMUM, ALL MATERIALS (INCLUDING
SPECIFICATIONS), METHODS OF CONSTRUCTION, VISUAL AND DIMENSIONAL
CHARACTERISTICS PERTINENT TO THE MATERIEL BEING PROCURED BY THE
GOVERNMENT.
THE CONTRACTOR SHALL DEVELOP AND DOCUMENT THEIR OWN DETAILED PARTS
LIST AND METHOD OF CONSTRUCTION ENGINEERING DRAWINGS. A COPY OF THE
TECHNICAL PACKAGE SHALL BE PRESENTED TO THE DLA TROOP SUPPORT
CONTRACTING OFFICER ALONG WITH THE PRODUCT DEMONSTRATION MODEL OR
FIRST ARTICLE. ANY PDM OR FIRST ARTICLE SUBMISSION LACKING A
COMPLETE DOCUMENTED TECHNICAL DATA PACKAGE SHALL BE CONSIDERED
AN INCOMPLETE SUBMISSION AND WILL NOT BE ACCEPTED.
THE SPECIFICATIONS OF THE COMPONENTS AND SOURCES OF COMPONENT
MATERIALS SHALL BE IDENTIFIED, INCLUDING APPLICABLE SPECIFICATIONS, AND
SHALL NOT BE CHANGED THROUGHOUT THE LIFE OF THE CONTRACT WITHOUT
REQUEST AND APPROVAL BY THE DLA TROOP SUPPORT CONTRACTING OFFICER
THROUGH MODIFICATION TO THE CONTRACT.
THE FIRST ARTICLE (FA) SHALL BE A PACKAGED AND PRESERVED COMPLETE END
ITEM. THE UNIT SHALL BE ERECTED IN ACCORDANCE WITH TM 10-8340-224-13.
DLA TROOP SUPPORT MAY ELECT TO PERFORM PHYSICAL TESTING SPECIFIED IN
SECTION 4.0 VERIFICATION OF MIL-PRF-44271C AS PART OF THE FA TESTING.
DPSCM4155.3 REQUIREMENTS SHALL BE MAINTAINED FOR COMPONENT
CERTIFICATION AND CERTIFICATE OF COMPLIANCE. FABRICS REQUIRED TO BE
SOURCE SAMPLED SHALL INCLUDE ALL APPLICABLE CHARTERISTICS AND TEST
METHODS EQUAL TO THE COMPONENT SPECIFICATIONS IDENTIFIED IN THE
“HISTORICAL TECHNICAL DATA FOR REFERENCES PURPOSES ONLY” COMPONENT.
ALL FABRIC LOT RELEASE TESTING PROCEDURES ARE APPLICABLE.
SOURCES OF COMPONENT MATERIALS SHALL BE IDENTIFIED, INCLUDING
APPLICABLE SPECIFICATIONS, AND SHALL NOT BE CHANGED THROUGHOUT THE
LIFE OF THE CONTRACT WITHOUT REQUEST AND APPROVAL BY THE DSCP
CONTRACTING OFFICER THROUGH MODIFICATION TO THE CONTRACT.
ADDITIONAL QUALITY ASSURANCE REQUIREMENTS
FABRIC TEST REPORTS AND COMPONENT CERTIFICATIONS IN ACCORDANCE WITH
DPSCM-4155.3 IS REQUIRED WITH THE FIRST ARTICLE AND ALL CONTRACT
COMPONENT LOTS.
A PROCESS ORIENTED QUALITY PLAN IS REQUIRED FOR THIS CONTRACT: NO
SPECIFIC OR CERTIFIED GOVERNMENT, ANSI, ASTM OR ISO QUALITY ASSURANCE
PLAN IS REQUIRED BUT SUCH PLANS MAY BE FOUND TO BE ACCEPTABLE FOR
CONTROL REQUIREMENTS.
A DETAILED QUALITY ASSURANCE PLAN SHALL INCLUDE AT MINIMUM THE
FOLLOWING ELEMENTS:
A) IN-PROCESS INSPECTION FOR ALL INTEROPERABLE MEASUREMENTS IS
REQUIRED.
A PLAN IS REQUIRED FOR ALL PROCESSES, RESULTING IN PARTS THAT POSSESS
INTEROPERABLE DIMENSIONS, I.E. ANY COMPONENT LENGTH, WIDTH OR
LOCATION THAT WILL INTERFACE WITH ANOTHER COMPONENT DURING
ASSEMBLY OR OPERATION BY THE END USER. REPRESENTATIVE EXAMPLES OF
INTEROPERABILITY ARE: THE DIMENSION OF THE EAVE LINE GROMMET TO THE
GROUND LINE, OR RIDGE LINE GROMMET TO THE EAVE LINE GROMMET THAT
WILL INTEROPERATE WITH THE TENT FRAME, OR THE LOCATION OF THE BECKET
LACES WHICH INTEROPERATING WITH THE LACING GROMMETS.
ANY INSPECTION METHOD MUST TAKE INTO ACCOUNT THE FOLLOWING THREE
UNSPECIFIED VARIABLES:
TAKE-UP, BUILD-UP OF TOLERANCES AND OPPOSING TOLERANCES
1. TAKE-UP. TAKE-UP FROM JOINING SEAMS CAUSES DISTORTIONS IN THE
GEOMETRY OF THE END ITEM COMPONENT.
RATIONAL: ALL SPECIFIED INDIVIDUAL0 DIMENSIONS CAN BE WITHIN
TOLERANCE, I.E. PERIMETER EDGE MEASUREMENTS, HOWEVER, WITH THE
COMPILATION OF EXCESS TAKE-UP FROM SEAMING AND THE ATTACHMENT OF
COMPONENT PARTS, THE CUSTOMER WOULD RECEIVE A COMPONENT INCAPABLE
OF CORRECTLY FITTING, AS DESIGNED, OVER THE TENT FRAME. EVERY STITCH
CREATES IT'S OWN SMALL PUCKER WITH THOUSANDS OF STITCHES FROM
JOINING SEAMS, ATTACHING WINDOWS, VENTS, FLAPS, ADAPTERS ECT. THE
UNMEASURED CENTER OF THE PANEL PULLS THE PERIMETER INWARD.
METHOD: ACCEPTABLE METHODS FOR DETERMINING THIS CONDITION MUST
INCLUDE THE MEASUREMENT OF ALL THE INTEROPERABLE POINTS
SIMULTANEOUSLY. IF A GAUGE OR JIG DEVICE IS USED THE APPARATUS MUST
ACCOUNT FOR ALL APPLICABLE TOLERANCES. A GOVERNMENT QUALITY
ASSURANCE SPECIALIST SHALL VERIFY THE APPARATUS FOR ACCURACY AGAINST
THE APPROVED PDM BY THE DIRECTION OF THE CONTRACTING OFFICER. 100
PERCENT IN-PROCESS INSPECTION IS REQUIRED. THE END ITEM LOT SAMPLE
UNITS SHALL BE INSPECTED WITH THIS GAUGE.
2. BUILD-UP OF TOLERANCES. AREAS REQUIRED FOR IN-PROCESS INSPECTIONS
SHALL ALSO INCLUDE PROCESSES THAT THAT CAN BE AFFECTED BY A BUILD-UP
OF TOLERANCES. AN EXAMPLE IS BECKET AND GROMMET INTEROPERABLE
LOCATIONS.
RATIONAL: IF A MAXIMUM TOLERANCE IS USED BETWEEN EVERY GROMMET
SPACE AND A MINIMUM TOLERANCE IS USED FOR THE EAVE TO RIDGE GROMMET
OR EAVE-LINE GROMMET TO GROUND-LINE GROMMET, THE SPACING OF THE
LAST GROMMET TO THE EAVE-LINE GROMMET WOULD NOT BE UNIFORM. THIS
MAY BE FURTHER COMPLICATED IF THE NEXT TENT SECTION IS ON THE
MAXIMUM SIDE OF THE TOLERANCES.
3. OPPOSING TOLERANCES. OPPOSING TOLERANCES SHALL ALSO BE
EXAMINED. IN-PROCESS INSPECTIONS TO CONTROL THIS CONDITION ARE
REQUIRED.
RATIONALE: FOR EXAMPLE, IF A MINIMUM TOLERANCE IS TAKEN BETWEEN THE
EAVE TO RIDGE AND A MAXIMUM FOR THE LENGTH OF THE WEATHER SEAL FLAP
PLUS, A MAXIMUM FOR THE PLACEMENT TO ATTACH THE FLAP FROM THE RIDGE
LINE, THE FLAP WILL COVER THE EAVE GROMMET. FLAPS FOR THE STOVEPIPE,
WINDOW OR VENTS MANUFACTURED TO THE MINIMUM AND OPENINGS MADE TO
THE MAXIMUM WILL ALSO RESULT IN POOR WORKMANSHIP.
B) RISK CLASSIFICATION ASSESSMENT
QUALITY ASSURANCE PLANS SHALL ACCOUNT AND ASSESS THE PROCESS RISK
FOR EACH PROCESS. CONSIDERATION FOR CLASSIFYING RISKS OF A PROCESS
INCLUDES THE PROCESSES SOPHISTICATION, PROCESS STABILITY, AND
PROCESSES PRODUCING INTEROPERABILITY COMPONENTS.
CONTROL OF PRODUCT QUALITY IS DEPENDENT ON IDENTIFYING THE FOLLOWING
CLASSIFICATIONS:
LOW RISK: PROCESSES YIELDING PRODUCTS WITH SMALL IMPACT ON THE
FUNCTIONALITY OF THE END ITEM. CONFIDENCE IS ESTABLISHED FOR THESE
IDENTIFIED PROCESSES BY QUALITY DATA COLLECTION FOR PERIODIC
VERIFICATION AGAINST THE CONTRACTOR’S SPECIFICATIONS
MODERATE RISK: USE THIS CLASSIFICATION WHEN A PROCESS YIELDING
PRODUCTS THAT CANNOT BE CLASSIFIER AS LOW OR HIGH RISK OR CONTAINS
HIDDEN OPERATIONS. CONSIGNORS PRODUCT VERIFICATION AND DATA
COLLECTION SHALL BE PERFORMED UNTIL THE PROCESS CAN BE PROVED TO BE
IN CONTROL.
HIGH RISK: USE WHEN THE PROCESS PERFORMANCE IS CRITICAL TO THE
PERFORMANCE, OR THE PROCESS YIELDS COMPONENTS THAT MUST
INTEROPERATE. SOPHISTICATED PROCESSES SUCH AS HEAT SEALED SEAMS
THAT CAN RESULT IN CATASTROPHIC END ITEM FAILURE WHERE
ENVIRONMENTAL CONDITIONS AFFECT THE PROCESS OUTPUT SHALL BE
CONSIDERED HIGH RISK. INTENSIFIED PRODUCT AUDITS SHALL BE USED TO
VERIFY THE CONTROL OF THE PROCESS.
RECLASSIFICATION TO A LOWER RISK CATEGORY OF ANY PROCESS IS PERMITTED
AFTER THE IN-PLANT GOVERNMENT QUALITY REPRESENTATIVE HAS PROOFED
THE PROCESS AND AGREES THAT THE PROCESS IS IN CONTROL AND
CONFIDENCE IN THE PROCESS IS ESTABLISHED. RECLASSIFICATION TO A
HIGHER RISK CATEGORY IS REQUIRED WHEN A GOVERNMENT PRODUCT AUDIT
IDENTIFIES THAT A PROCESS IS PRODUCING A RUNNING NONCONFORMANCE OR
DEPARTURE.
C) DEFECT CLASSIFICATION AND QUALITY AUDIT CRITERIA
A. THE CONTRACTORS PROPOSED QUALITY ASSURANCE PLAN MUST INCLUDE A
DETAILED LIST OF END ITEM VISUAL DEFECTS, PACKAGING NONCONFORMITIES
AND LOT ACCEPTANCE CRITERIA INCLUDING ANY ACCEPTABLE QUALITY LEVELS.
RECOMMENDED DEFECTS WITH RELATION TO SEVERITY ARE LISTED BUT NOT
LIMITED TO THE FOLLOWING:
1. MAJOR DEFECTS: ANY HOLE, CUT, TEAR; COLOR NOT AS SPECIFIED; OPEN
SEAMS; LOOSE THREAD TENSION RESULTING IN LOOSE SEAMS; ANY MATERIAL
DEFECTS, DISTORTED PARTS OR POOR WORKMANSHIP; ANY COMPONENT PART
OMITTED; LABEL MISSING, INCORRECT, OR ILLEGIBLE; MEASUREMENT NOT AS
SPECIFIED
2. MINOR DEFECTS ANY PART SHADED: ANY SPOT OR STAIN (OUTSIDE); RAW
EDGES (ON NON-COATED WOVEN CLOTHS); THREAD ENDS NOT REMOVED, BAR
CODE OMITTED OR NOT READABLE BY SCANNER; BAR CODE NOT VISIBLE ON
FOLDED, PACKAGED ITEM; BARCODE CAUSES DAMAGE TO THE ITEM; ANY ITEMS
NOT PACKAGED IN ACCORDANCE WITH THE CONTRACT OR CONTRACTORS
SPECIFICATIONS.
B. RESPONSIBILITY FOR INSPECTION. THE CONTRACTOR IS RESPONSIBLE FOR
THE PERFORMANCE OF ALL INSPECTION, EXAMINATION, AND TEST
REQUIREMENTS SPECIFIED HEREIN AND IN THE SITED SPECIFICATIONS. THE
GOVERNMENT RESERVES THE RIGHT TO PERFORM ANY OF THE INSPECTIONS,
EXAMINATIONS AND TESTS AS DEEMED NECESSARY TO ENSURE SUPPLIES AND
SERVICES CONFORM TO PRESCRIBED REQUIREMENTS.
-D) TESTING
LOT INSPECTION IN ACCORDANCE WITH THE "AMERICAN NATIONAL STANDARDS
INSTITUTE (ANSI) ANSI/ASQC Z1.4 SAMPLING PROCEDURES AND TABLES FOR
INSPECTION BY ATTRIBUTES IS REQUIRED. LOT SIZES SHALL BE EXPRESSED IN
UNITS OF COMPLETELY FABRICATED TENTS. A CONTRACTOR DEVELOPED TABLE
OF DEFECTS ALONG WITH A SAMPLING PLAN WITH ACCEPTABLE QUALITY LEVELS
FOR:
1. END ITEM VISUAL EXAMINATION
2. END ITEM DIMENSIONAL AND INTEROPERABLE
3. END ITEM TESTING
4. PACKAGING
THE CONTRACTOR SHALL CERTIFY AND MAINTAIN SUBSTANTIATING EVIDENCE
THAT THE PRODUCT PRESENTED TO THE GOVERNMENT FOR ACCEPTANCE ARE
TENTS WHICH FULLY MEET AND COMPLY WITH THE GOVERNMENT'S
PERFORMANCE SPECIFICATION REQUIREMENTS, THE PRODUCERS
SPECIFICATIONS AND DRAWINGS, STANDARDS, AND QUALITY ASSURANCE
PRACTICES AND THAT WHICH CONFORM TO THE QUALITY STANDARDS AGREED
TO AT THE TIME OF CONTRACT AWARD. END ITEMS SHALL BE EXAMINED AS
CONTRACTUALLY SPECIFIED FOR ALL DEFECTS AND IN ACCORDANCE WITH THE
ACCEPTABLE QUALITY LEVEL AND DEFECT CRITERIA IN THIS CONTRACTS
APPROVED QUALITY ASSURANCE PLAN.
RESPONSIBILITY OF INSPECTION. THE CONTRACTOR IS RESPONSIBLE FOR THE
PERFORMANCE OF ALL INSPECTION, EXAMINATION, AND TEST REQUIREMENTS
SPECIFIED HEREIN AND IN THE SITED SPECIFICATIONS AND CONTRACT. THE
GOVERNMENT RESERVES THE RIGHT TO PERFORM ANY OF THE INSPECTIONS,
EXAMINATIONS AND TESTS AS DEEMED NECESSARY TO ENSURE SUPPLIES AND
SERVICES CONFORM TO PRESCRIBED REQUIREMENTS
APPLICABLE DOCUMENTS:
THE FOLLOWING LIST OF DOCUMENTS IS APPLICABLE TO THIS PROCUREMENT:
DEPARTMENT OF DEFENSE INDEX OF SPECIFICATIONS AND STANDARDS. PART
I AND II, JULY 2000 AND SUPPLEMENT, MARCH 2000.
SPECIFICATIONS
FEDERAL
A-A-55634A COMMERICAL ITEM DESCRIPTION, ZIPPERS
(FASTENERS, SLIDE INTERLOCKING) DATED 23 MARCH,
MILITARY
MIL-C-43256D NOT 1 MILITARY SPECIFICATION CORD, FIBROUS, POLYESTER,
SOLID BRAID DATED 16 JUNE, 1997 IS INACTIVE FOR NEW
DESIGN AND IS NO LONGER USED EXCEPT FOR
REPLACEMENT PURPOSES.
MIL-R-24049B MILITARY SPECIFICATION ROPE, POLYPROPYLENE DATED 14
JUNE, 1991.
MIL-DTL-32072 THREAD, POLYESTER DATED 08 JAN 2002 SUPERSEDING
V-T-285F JANUARY 03, 1991
MIL-DTL-32075 DATED 17 OCTOBER 2000
LABEL: FOR CLOTHING, EQUIPAGE, AND TENTAGE,
(GENERAL USE) SUPERSEDING DDD-L-20 DATED
MARCH 30, 1990.
MIL-DTL-53039C DATED 19 FEBRUARY 2009
COATING, ALIPHATIC POLYURETHANE, SINGLE
COMPONENT,
CHEMICAL AGENT RESISTANT
MIL-PRF-20696F CLOTH, WATERPROOF, WEATHER RESISTANT, DATED
2 SEPT 1997.
UNITED STATES INDUSTRIAL FABRICS INSTITUTE (USIFI) CLOTH
SPECIFICATIONS USIFI-PRF-44103 AND USIFI-PRF-20696 SHALL BE USED IN
PREFERENCE TO MIL-PRF-44103D AND MIL-PRF-20696F
USIFI - UNITED STATES INDUSTRIAL FABRICS INSTITUTE, A DIVISION OF IFAI
1801 COUNTY ROAD B WEST
ROSEVILLE, MN 55113
http://www.usifi.com
INTERIM CHANGES TO MIL-PRF-20696F:
PAGE 4, PARAGRAPH 3.7, TABLE I REQUIREMENTS: DELETE ALL REQUIREMENTS
FOR WEIGHT AND SUBSTITUTE THE FOLLOWING UNDER THE APPROPRIATE
COLUMN:
TYPE I
CLASS 1 2 3
"WEIGHT OZ/YD2 (MAX) 9.0 10.0 11.5
TYPE II & IV III
CLASS 1 2 3 5
17.0 19.0 19.0 13.0"
UNDER REQUIREMENTS FOR FLAME RESISTANCE (MAX), AFTER FLAME AND CHAR
LENGTH, DELETE "10" AND "3.5" FROM THE TYPE II & IV CLASS 1 COLUMN AND
INSERT UNDER TYPE I CLASS 3 COLUMN. UNDER REQUIREMENTS FOR FLAME
RESISTANCE (MAX), AFTER FLAME AND CHAR LENGTH, DELETE "10" AND "3.5"
FROM TYPE III CLASS V COLUMN AND INSERT UNDER TYPE II & IV, CLASS 3
COLUMN.
PAGE 5, AFTER PARAGRAPH 3.8 ADD THE FOLLOWING: "3.9 LENGTH AND PUT-UP.
UNLESS OTHERWISE SPECIFIED (SEE 6.2), THE CLOTH SHALL BE FURNISHED IN
ROLLS CONTAINING 50 TO 65 YARDS. NO ROLL SHALL CONTAIN MORE THAN
THREE PIECES AND NO SINGLE PIECE SHALL BE LESS THAN 10 YARDS IN
LENGTH."
PAGE 5, PARAGRAPH 4.3.2.1 YARD BY YARD EXAMINATION: AT THE END OF
PARAGRAPH, ADD THE FOLLOWING: "THE NUMBER OF ROLLS FROM WHICH THE
SAMPLE YARDAGE IS TO BE SELECTED SHALL BE IN ACCORDANCE WITH THE
FOLLOWING TABLE:
LOT SIZE (YARDS) SAMPLE SIZE (ROLLS)
UP TO 1200 INCLUSIVE 1/ 3
1201 UP TO AND INCLUDING 3200 5
3201 UP TO AND INCLUDING 10,000 8
10,001 UP TO AND INCLUDING 35,000 13
35,001 UP TO AND INCLUDING 150,000 20
150,001 AND OVER 32
1/ IF A LOT CONTAINS FEWER THAN THREE ROLLS, EACH ROLL IN THE LOT SHALL
BE EXAMINED."
THE INSPECTION LEVEL SHALL BE II AND THE ACCEPTABLE QUALITY LEVEL (AQL),
EXPRESSED IN TERMS OF DEFECTS PER HUNDRED UNITS, SHALL BE 2.5 FOR
MAJOR DEFECTS AND 6.5 FOR TOTAL (MAJOR AND MINOR COMBINED) DEFECTS.
MIL-DTL-43002E SHIELD, STOVEPIPE, TENT, NONMETALLIC
14 SEPTEMBER, 2000
MIL-PRF-44103D CLOTH, FIRE, WATER AND WEATHER RESISTANT, DATED
19 NOVEMBER, 1996.
UNITED STATES INDUSTRIAL FABRICS INSTITUTE (USIFI) CLOTH
SPECIFICATIONS USIFI-PRF-44103 AND USIFI-PRF-20696 SHALL BE USED IN
PREFERENCE TO MIL-PRF-44103D AND MIL-PRF-20696F.
USIFI - UNITED STATES INDUSTRIAL FABRICS INSTITUTE, A DIVISION OF IFAI
1801 COUNTY ROAD B WEST
ROSEVILLE, MN 55113
http://www.usifi.com
MIL-DTL-44258B ELECTRICAL DISTRIBUTION ASSEMBLIES FOR
TENT, EXTENDABLE, MODULAR, PERSONNEL (TEMPER)
NOTICE 2, 21 JANUARY, 2009.
MIL-DTL-44285A DOORS, DOUBLE BUMP THROUGH, 9 MARCH, 2000
MIL-C-53004B MILITARY SPECIFICATION CAMOUFLAGE SCREENING
SYSTEMS, MODULAR, LIGHTWEIGHT, SYNTHETIC,
WOODLAND, DESERT AND SNOW 18 JULY, 1997.
MIL-DTL-53039C COATING, ALIPHATIC POLYURETHANE, SINGLE
COMPONENT, CHEMICAL AGENT RESISTANT, DATED
19 FEBRUARY, 2009
MIL-PRF-44259E LIGHT SET, PORTABLE, FLUORESCENT, 29 JUNE, 2009
DPSCM-4155.3 QUALITY SYSTEMS REQUIREMENTS DATED NOVEMBER
03, 1997
MIL-I-45208A INSPECTION SYSTEMS REQUIREMENTS,
DATED 12/16/63; AM. 1, 7/24/81
NOTE: MIL-I-45208 HAS BEEN CANCELED: USE THE INTERNATIONAL
STANDARDS ISO 9002 OR ANSI/ASQC Q9002 IN PREFERANCE TO THE MIL-I-
45208
HIGHER LEVEL INSPECTION SYSTEM: THE INSPECTION SYSTEM(S) MUST BE
SUBMITTED WITH YOUR BID PROPOSAL FOR EVALUATION AND APPROVAL BY
DLA TOOP SUPPORT CONTRACTING OFFICER. INSPECTION SYSTEM(S)
COMPLIANT/BUT ARE NOT LIMITED TO THE INTERNATIONAL STANDARDS ISO
9002 OR ANSI/ANQC Q9002
MIL-L-1709E LINE, TENT, 10 AUGUST, 1989
"INTERIM CHANGES TO MIL-L-1709E:
THE USE OF MANILA LINES HAS BEEN DISCONTINUED. LINES IN TYPES SPECIFIED
SHALL BE FABRICATED FROM ROPE, POLYPROPYLENE, COLOR BLACK, IN
ACCORDANCE WITH MIL-R-24049B, DATED 14 JUNE 1991, OR BRAIDED
POLYESTER CORD, COLOR BLACK, IN ACCORDANCE WITH MIL-C-43256D, DATED 2
JULY 1991. THE ALTERNATE LINES SHALL BE OF THE SAME DIAMETER AS THE
SPECIFIED MANILA LINES. MINIMUM BREAKING STRENGTH OF THE ALTERNATE
LINES SHALL BE EQUAL TO OR GREATER THAN THE SPECIFIED MANILA LINES.
POLYESTER LINES MAY BE KNOTTED TO THE SAME DIMENSION AS THE SPECIFIED
SPLICE. THE KNOT SHALL HAVE THE SAME FUNCTION AS THE REPLACED SPLICE
AND SHALL NOT INTERFERE WITH OPERATION OF THE TENT SYSTEM. ALL LINES
SHALL INTEROPERATE WITH THE TENT SLIP OR GROMMET EQUALLY AS THE
REPLACED MANILA LINE."
MIL-P-501P MILITARY SPECIFICATION PIN, TENT, METAL, DATED 01
MARCH 1991
MIL-P-2383H NOT 1 MILITARY SPECIFICATION PINS, TENT, WOOD, DATED 11
ARRIL 1994
MIL-S-1734J SLIPS, TENT LINE, 30 JANUARY, 2002 SUPERSEDING
MIL-S-1734H DATED 06 DECEMBER, 1984.
NOTE: THE BELOW CHANGES TO THE MIL-S-1734H NEED TO BE COMPLIED
WITH IN CONJUCTION WITH THE MIL-S-1734J, SLIPS, TENT LINE, 30 JANUARY,
2002.
MIL-S-1734H SLIPS, TENT LINE
INTERIM SPECIFICATION CHANGES TO
MIL-S-1734H:
PARA. 1.2, AFTER TYPE II, DELETE “CASTING” AND SUBSTITUTE “INJECTION
MOLDED”.
PARA. 2.1, UNDER “SPECIFICATION, FEDERAL”, DELETE “QQ-M-38, QQ-M-55, QQ-
M-56” AND TITLES; UNDER “STANDARDS”, ADD “FED-STD-595-COLORS”.
PARA. 2.2, UNDER “ASTM”, DELETE “B94 AND TITLE”; SUBSTITUTE “D4066-NYLON
INJECTION MOLDED AND EXTRUSION MATERIALS (PA).”
PARA. 3.2.1.3, DELETE IN ITS ENTIRETY.
PARA. 3.2.4, DELETE AND SUBSTITUTE: “3.2.4 ENAMEL. ENAMEL SHALL CONFORM
TO COMPOSITION G OR L OF TT-E-529 CAMOUFLAGE GREEN COLOR NO. 34094 OF
FED-STD-595.”
PARA. 3.3.2, DELETE AND SUBSTITUTE: “3.3.2 TYPE II. THE TYPE II TENT LINE SLIP
SHALL BE FABRICATED OF NYLON 6 WITH 30 PERCENT GLASS, CONFORMING TO
ASTM D 4066. MATERIAL SHALL CONTAIN AN ULTRAVIOLENT STABILIZER. CLEAN
UNBURNED MATERIAL IN THE FORM OF RUNNERS, OR FROM OTHER MOLDING OR
FINISHING OPERATIONS MAY BE GROUND AND MIXED WITH VIRGIN MATERIAL.
WHEN REGROUND MATERIAL IS MIXED WITH VIRGIN MATERIAL, IT SHALL NOT
EXCEED A LEVEL OF 20 PERCENT BY WEIGHT OF THE BLENDED MIXTURE. THE
SURFACE OF THE MOLDING SHALL BE FREE OF DIRT, DUST OF FOREIGN MATTER
INCLUSION. CAMOUFLAGE GREEN COLOR NO. 34094 OF FED-STD-595 SHALL BE
INCLUDED IN THE PLASTIC COMPOUND. NO FURTHER COLOR TREATMENT
REQUIRED.
PARA. 3.4.1, LINE 1 AND LINE 3, AFTER “OF THE” ADD, “TYPE I”.
MIL-STD-105E SAMPLING PROCEDURES AND TABLES FOR
INSPECTION BY ATTRIBUTES, 06 FEBRUARY, 2008
SUPERSEDING NOTICE 2 DATED 26 MARCH, 2001
MIL-STD-105E, DATED 10 MAY, 1989, IS HEREBY CANCELED. FUCTURE
ACQUISTIONS MAY REFER TO: MIL-STD-1916, “DOD PERFERRED METHODES FOR
ACCEPTANCE OF PRODUCT” , OR ANSI/ASQ Z1.4 SAMPLING PROCEDURES AND
TABLES FOR INSPECTION BY ATTRIBUTES
APPLICATION FOR COPIES SHOULD BE OBTAINED FROM:
AMERICAN SOCIETY FOR QUALITY CONTROL
600 NORTH PLANKINTON AVENUE,
MILWAUKEE, WI 53203
MIL-STD-129P DEPARTMENT OF DEFENSE STANDARD PRACTICE
MILITARY MARKING FOR SHIPMENT AND STORAGE
WITH CHANGE 4 DATED 19 SEPTEMBER, 2007
SUPERSEDING MIL-STD-129P WITH CHANGE 3 DATED
29 OCTOBER, 2004
MIL-STD-129P INTERIM CHANGES:
OMISSION OF MARKINGS ON EXTERIOR SHIPPING CONTAINERS OF ITEMS
IN THE DEFENSE LOGISTICS AGENCY TROOP SUPPORT, CLOTHING AND TEXTILE
(C&T) DIRECTORATE:
THE NOMENCLATURE AND MANUFACTURER'S NAME (WHEN THE NAME IDENTIFIES
THE MATERIAL) SHALL BE OMITTED FROM ALL EXTERIOR SHIPPING CONTAINERS
OF DLA TROOP SUPPORT C&T ITEMS, REGARDLESS OF MODE OF SHIPMENT.
IF THE MANUFACTURER'S NAME DOES NOT IDENTIFY THE MATERIAL AS BEING
CLOTHING, IT MAY REMAIN. NSNS SHALL BE SHOWN ON ALL SHIPPING
CONTAINERS OF C&T ITEMS, THE PACKING LIST SHALL BE PLACED INSIDE THE
LAST CONTAINER TO BE LOADED FOR EACH SHIP- MENT. THE WORDS "PACKING
LIST HERE" SHALL BE STENCILED, NOT
HAND LETTERED, ON THE CONTAINER.
MIL-HDBK-129 DEPARTMENT OF DEFENSE HANDBOOK MILITARY
MARKING NOTICE 1 DATED 15 DECEMBER, 2002.
MIL-HDBK-129, DATED 15 MAY 1997, IS HEREBY CANCELED. FUCTURE
ACQUISTIONS SHOULD REFER TO MIL-STD-129, MILITARY MARKING FOR
SHIPMENT AND STORAGE, STANDARD PRACTICE.
MIL-STD-130N DEPARTMENT OF DEFENSE IDENTIFICATION MARKING
OF U.S. MILITARY PROPERTY, DATED DECEMBER 2007
SUPERSEDING MIL-STD-130M WITH CHANGE 1, DATED
15 JUNE, 2007
MIL-STD-1472F DEPARTMENT OF DEFENSE DESIGN CRITERIA
STANDARD HUMAN ENGINEERING DATED 23 AUGUST
1999 CHANGE NOTICE 1, DATED 05 DECEMBER 2003
MIL-STD-810G DEPARTMENT OF DEFENSE TEST METHOD STANDARD
ENVIRONMENTAL ENGINEERING CONSIDERATIONS
AND LABORATORY TESTS DATED 31 OCTOBER, 2008
SUPERSEDING MIL-STD-810F DATED 01 JANUARY, 2000
MIL-STD-1366E DEPARTMENT OF DEFENSE INTERFACE STANDARD FOR
TRANSPORTABILITY CRITERIA, DATED 31 OCTOBER,
2006 SUPERSEDING MIL-STD-1366D DATED 18
DECEMBER, 1998
MIL-STD-1916 DEPARTMENT OF DEFENSE TEST METHOD STANDARD
DOD PREFERRED METHODS FOR ACCEPTANCE OF
PRODUCT DATED 01 APRIL, 1996
MIL-STD-2073-1E, STANDARD PRACTICE FOR MILITARY PACKAGING DATED
23 MAY, 2008
MIL-STD-731A MILITARY STANDARD QUALITY OF WOOD MEMBERS
FOR CONTAINERS AND PALLETS, DATED 03 MAY2002
SUPERSEDING NOTICE 2, DATED 05 AUG 1995
MIL-STD-731A DATED 04 OCTOBER, 1990 IS HEREBY CANCELLED AND
SUPERSEDED BY ASTM D6199 ENTIRELY.
MIL-STD-147E DEPARTMENT OF DEFENSE PALLETIZED UNIT LOADS
DATED 16 MAY, 2008 SUPERSEDING MIL-STD-147D
DATED 10 DECEMBER 1988
STANDARDS
FEDERAL
V-T-285F NOTICE 1 FEDERAL SPECIFICATION THREAD, POLYESTER, 03/APRIL,
V-T-285F FEDERAL SPECIFICATION THREAD, POLYESTER, 1/3/91 IS
HEREBY CANCELED AND REPLACED BY MIL-DTL-32072
THREAD, POLYESTER DATED 08 JAN 2002
INTERIM CHANGES TO V-T-285F:
PAGE 3, PARA. 2.2, AFTER LINE 8, ADD:
"AMERICAN ASSOCIATION OF TEXTILE CHEMISTS AND COLORISTS (AATCC)
AATCC 20 - FIBER ANALYSIS: QUALITATIV (APPLICATIONS FOR COPIES
SHOULD BE ADDRESSED TO AMERICAN ASSOCIATION OF TEXTILE
CHEMISTS AND COLORISTS (AATCC), P.O. BOX 12215, TRIANGLE PARK, NC
27709-2215)"
PAGE 12, PARA 4.2.3 - TABLE X, END ITEM TESTS, UNDER TEST METHOD
COLUMN, LINES 1 AND 2, DELETE "1600" AND SUBSTITUTE "AATCC 20".
PAGE 10, PARAGRAPH 4.2.1.1 THREAD ON HOLDER EXAMINATION LINE 7,
DELETE "1.5" AND "4.0" AND SUBSTITUTE "1.0" AND "2.5".
PAGE 11, PARAGRAPH 4.2.1.2 THREAD AS UNWOUND EXAMINATION, LINE 8,
DELETE "1.5" AND "4.0" AND SUBSTITUTE "1.0" AND "2.5".
PAGE 12, PARAGRAPH 4.2.3 END ITEM TESTING, LINE 8, DELETE "6.5" AND
SUBSTITUTE "4.0". APPROVED FINISHES FOR TY I CL 1 SUBCLASS B NON-
WICKING THREAD OF V-T-285; NW-1-AMERICAN THREAD CO. 90 PARK AVE,
NY, NY
10016; 33Q-COATS & CLARK INC, 430 PARK AVE, NY, NY 10022; ZS-
AMERICAN & EFIRD THREAD MILLS, MT. HOLLY, NC 28120; CBF-THREADS
INC, GASTONIA NC, 28053; WRE-THE LINEN THREAD CO, 12 MUNROE ST.,
WINSTED, CT 06098; 929-GUDEBROD BROS. SILK CO, 12 S. 12TH ST, PHILA.
PA 19107; AW-8-PREMIER THREAD CO, 345 THAMES ST, BRISTOL, RI 02809;
EINW-EDDINGTON THREAD MFG, CO. STREET ROADS, EDDINGTON, PA
19020; ST4-1-STD THREAD CONVERTING CO, PAWTUCKET, RI 02862; CE-T4-
JOHN C. MEYER THREAD CO. 62 FREMONT ST. WORCHESTER, MA 01603;
RTC-P-ROBINSON THREAD CO. INC. 19 MCKEON RD, WORCHESTER, MA
01610;AWSL-HOLLAND THREAD CO.INC. 423 MAIN ST., STROUDSBURG, PA
18360; ARCO-A.H. RICE CO. PITTSFIELD, MA 01201;SCB-SYNTHETIC
THREAD CO. 825 TWELFTH AVE, BETHLEHEM, PA 18018;
ASEW-HEMINWAY & BARTLETT MFG CO.WATERTOWN, CT, 06795
L-S-125B SCREENING, NONMETALLIC INSECT, 2/3/72
FED-STD-191A TEXTILE TEST METHODS, 7/29/78
CH NOT 1, 3/19/85; CH NOT 2,
8/15/85; CH NOT 3, 1/15/86;
CH NOT 4, 3/31/87; CH NOT 5,
12/28/89; CH NOT 6, 6/21/90
CHANGE NOTICE 7, DATED 8/9/2000:
FED-STD-191A NOTICE 1, DATED 21 JUNE 1990 IS
HEREBY INACTIVE FOR NEW DESIGN.
ADDITIONAL INFORMATION FOR FED-STD-191:
FED-STD-191A NOTICE 7, DATED AUGUST 9, 2000 IS HEREBY INACTIVE FOR NEW
DESIGN. WHEN NOT USING FED-STD-191, SEE INTERIM CHANGES TO END ITEM
SPECIFICATION FOR REPLACEMENT ASTM.
INTERIM CHANGES TO FED-STD-191A:
TEST METHOD 5202, PARA. 5.3, DELETE FIRST SENTENCE AND SUBSTITUTE: "THE
SPECIMEN SHALL BE CLAMPED FIRMLY, WITH ONE END FLUSH WITH THE OUTER
EDGE OF THE VISE, SUCH THAT ONE INCH OF SPECIMEN LIES WITHIN THE CLAMP
AND ONE INCH OF THE SPECIMEN EXTENDS BEYOND THE CENTER OF ROTATION
(FACE OF THE VISE), AND WITH THE LONG EDGE PARALLEL TO THE FACE OF THE
DIAL PLATE".
TEST METHOD 5309.1 ABRASION RESISTANT OF TEXTILE WEBBING. PAGE 1, PARA
4.1.2,LINE 4: DELETE "B-97" AND SUBSTITUTE "B-91".
THE FOLLOWING METHODS ARE IDENTIFIED AS SPECIFYING OZONE DEPLETING
SUBSTANCES: 1100, 1200, 1240, 1400, 1410, 1500, 1510,1520,1530, 1540, AND
1550. PARA 5.1 OF THESE TEST METHODS REQUIRE THE USE OF 1,1,1-
TRICHLOROETHANE, ALCOHOL OR ETHER. 1,1,1-TRICHLORETHANE IS AN OZONE
DEPLETING SUBSTANCE (METHYL CHLOROFORM) AND IS THEREFORE
PROHIBITED. THE USE OF EITHER ALCOHOL OR ETHER IS REQUIRED WHEN
THESE METHODS ARE IN BASIC OR ANY REFERENCED DOCUMENT.
METHOD 5202, STIFFNESS OF CLOTH, DIRECTIONAL; CANTILEVER BENDING
METHOD. PAGE 2, PARA. 5.3 DELETE FIRST SENTENCE AND SUBSTITUTE WITH
THE FOLLOWING: "THE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .