View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQUEST QUOTE

Return to top

Established ScreenTape technology guarantees superior ease-of-use of the system

Constant costs per sample for up to 16 samples per run

Wide range of RNA and DNA ScreenTape applications available including assays for genomic and cell-free DNA

Results are obtained quickly; in as little as 1 to 2 minutes per sample, or less than 20 minutes for 16 samples

Easily switch between DNA and RNA ScreenTape assays for excellent application flexibility

Integrity standards for RNA (RNA integrity number equivalent, RIN ) and genomic DNA (DNA Integrity Number, DIN) available

Compact footprint saves precious bench space in the laboratory

Seamless upgrade to 4200 TapeStation possible by complete assay compatibility

4150 TapeStation System The new Agilent 4150 TapeStation system complements the Agilent automated electrophoresis platforms with a new, compact, low-throughput instrument. Building on the success of the proven ScreenTape technology, it allows a quick, easy and reliable analysis of nucleic acids for up to 16 samples per run. This affordable, entry-level system is the ideal solution for the quality control (QC) of RNA and DNA samples in next-generation sequencing (NGS), microarray and qPCR workflows.

PRODUCT DETAILS RELATED PRODUCTS

TapeStation Instruments

Description

G2992AA 4150 TapeStation System QTY

Part Number

1 - 1 of 1 results

Features e

Specifications

Depth 510 mm

Dimensions (WxDxH) 254 mm x 510 mm x 415 mm

Height 415 mm

Line Frequency 50-60 Hz

Line Voltage 100-240 VAC

Number of Samples per Run Any number between 1-16

Power Consumption 50 VA

See All Return to top

Quality Control of Magnis SureSelect XT HS Workflow with Agilent Automated Electrophoresis Solutions The Agilent 4150 TapeStation system performs reliable sample quality control (QC) through various steps of the SureSelect XT HS target enrichment and nextgeneration sequencing (NGS) library preparation workflow on the Agilent Magnis NGS Prep system. The workflow includes QC steps for the incoming samples, intermediate products during library preparation, and final libraries.

Application Notes / English / 12 Feb 2020 / 1.16 MB / PDF

Monitoring Library Preparation for Next-Generation Sequencing in Systems Biology Omics Analysis Evaluation of the Agilent 4150 TapeStation system with ScreenTape assay to monitor exome and transcriptome library preparation for systems biology omics analysis.

Application Notes / English / 03 Jul 2019 / 1.15 MB / PDF

Retrospective Quality Analysis of DNA Samples from the Heidelberg CardioBiobank This Application Note demonstrates the use of the Agilent 4150 TapeStation system as a quality control (QC) tool to analyze DNA samples stored at the Heidelberg CardioBiobank (HCB).

Application Notes / English / 15 Apr 2019 / 972.77 KB / PDF

Applications for DNA, RNA and Protein Analysis. Agilent 2100 Bioanalyzer System and Agilent 4200 TapeStation System.

This compendium highlights key applications using the Agilent 2100 Bioanalyzer and 4200 TapeStation systems. From next generation sequencing, genomic DNA, RNA, genome editing to protein analyses, this compilation of applications will help you accelerate discovery and support your research.

Application Notes / English / 01 Feb 2018 / 3.61 MB / PDF

Agilent 4150 TapeStation System, Site Preparation Checklist Get you started and to assure a successful and timely installation with the 4150 TapeStation System.

Please refer to this specification or set of requirements.

Weight 17.8 kg

Width 254 mm

Literature

Application Notes

Brochures

Catalogs

Data Sheets

Posters

Technical Overviews

Support

Site Preparation Checklists

0 part selected. Clear All

COMPARE

http://www.agilent.com/search?filter=AND(SpSearch:Library,p_product_id:PRDT_297322_en_GLOBAL) https://www.agilent.com/cs/library/applications/application-quality-control-magnis-sureselect-5994-1741en-agilent.pdf https://www.agilent.com/cs/library/applications/application-alacris-monitoring-library-prep-omics-4150-tapestation-5994-0946en-agilent.pdf https://www.agilent.com/cs/library/applications/application-dna-quality-heidelberg-cardiobiobank-4150-tapestation-5994-0811en-agilent.pdf https://www.agilent.com/cs/library/applications/5991-8974EN_Bioanalyzer-TapeStation_appcompendium.pdf https://www.agilent.com/cs/library/sitepreparationchecklists/G2992AA_4150TS_%20SitePrep_Checklist_Apr19.pdf

Return to top

Site Preparation Checklists / English / 09 Apr 2019 / 416.84 KB / PDF

Get a new perspective on your sample QC 00:02:14

4200 TapeStation System

DNA and RNA sample quality control with flexible throughput (1-96) at a constant cost per sample.

Category: TapeStation Systems

TapeStation Software

Superior instrument control, data acquisition and analysis with the 4150 and the 4200 TapeStation systems.

Category: TapeStation Systems

Magnis NGS Prep System

Your lab's automated solution for NGS library preparation

Category: Hybridization-based Next Generation Sequencing (NGS)

Product Details

Features

Specifications

Literature

Support

Videos

Related Products

User Manuals

Videos

Related Products

0 part selected. Clear All

COMPARE

https://www.agilent.com/en/video/4150-tapestation https://www.agilent.com/en/product/automated-electrophoresis/tapestation-systems/tapestation-instruments/4200-tapestation-system-228263 https://www.agilent.com/en/product/tapestation-automated-electrophoresis/tapestation-software/tapestation-software-379381 https://www.agilent.com/en/product/hybridization-based-next-generation-sequencing-(ngs)/ngs-automation-platforms/magnis-ngs-prep-system-291083 https://www.agilent.com/en/product/automated-electrophoresis/tapestation-systems/tapestation-instruments/4200-tapestation-system-228263 https://www.agilent.com/en/product/tapestation-automated-electrophoresis/tapestation-software/tapestation-software-379381 https://www.agilent.com/en/product/hybridization-based-next-generation-sequencing-(ngs)/ngs-automation-platforms/magnis-ngs-prep-system-291083

File details come from the government source that posted it. Updated .