410lb Dryer Salient Characteristics_updated.pdf

PDF 202 KB Posted

Attached to
Industrial Dryer Equipment - ADG 410
Solicitation number
FA500026R0051
Issued by

About this file

This is a Product Specifications Memorandum from the U.S. Air Force 673d Air Base Wing at Joint Base Elmendorf-Richardson, Alaska, dated 30 June 2026, establishing baseline requirements for the replacement of a 410-pound gas dryer (American Dryer Corporation Model ADG410DD).

The memorandum specifies that the replacement dryer must be functionally equivalent or superior to the existing unit and fully compatible with existing facility utility connection points without requiring government-funded infrastructure modifications. Electrical specifications require 208-220V, 100-amp circuit breaker, 50-60 Hz, 3 wires, and 3-phase power. Performance and capacity requirements include 1,400,000 btu/hr heat input, 400-475 lbs maximum load, minimum 140 cubic feet tumbler volume, 9,200 cfm airflow, and a minimum of 6 programmable cycles. Physical and installation requirements mandate rear exhaust (24-28 inches), dimensions fitting within 8'6"w x 6'6"d x 10'h space, double tilt capabilities (forward and backward), and a 1-inch female pipe thread S.A.F.E. System water connection with 40-100 PSI pressure range. The contractor bears full responsibility for installation, utility connections (gas, air, electrical), all necessary modifications to existing utilities, removal of the old unit using appropriate lifting equipment, and relocation of the existing dryer to a designated staging area. Technical acceptability determinations are provided exclusively by Susan Meyer, GS-09, Assistant Laundry Manager, with points of contact Brenda Brown (brenda.brown.9@us.af.mil, 907-854-2429) and Susan Meyer (susan.meyer.1@us.af.mil, 907-384-1903).

View the file

Other files

File Type Posted
AD_410_Brochure_American Dryer Corp.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEPARTMENT OF THE AIR FORCE

673D AIR BASE WING

JOINT BASE ELMENDORF-RICHARDSON ALASKA

30 June 2026

MEMORANDUM FOR: 673d CONS/LGCC

FROM: 673 FSS/FSV

SUBJECT: Product Specifications for 410lb Gas Dryer

1. General requirement: 673 FSS/FSVA is replacing one, 410lb Gas Dryer; American Dryer

Corporation, Model number ADG410DD.

2. The specifications listed below describe the baseline for the required equipment. Any new machine must satisfy all these characteristics as a minimum requirement. The purpose is to acquire a replacement that is functionally equivalent or superior to the unit currently in place. The proposed equipment must be fully compatible with, and capable of connecting directly to, the facility’s existing utility connection points (including electrical, gas, water, air, and ventilation exhaust) without requiring government-funded modifications to the building's infrastructure.

Electrical Specifications:

• Voltage: 208 to 220V

• Circuit Breaker: 100 AMPs

• Hertz: 50-60 Hz

• Wires: 3

• Phase: 3

Performance and Capacity:

• Heat Input: 1,400,000 btu/hr

• Max Load: 400 - 475 lbs

• Tumbler Volume: At least 140 cu ft

• Airflow: 9,200 cfrn

• Programmable Cycles: Minimum of 6

Physical and Installation Requirements:

• Exhaust: Rear exhaust, 24"-28"

• Dimensions: Must fit within the space of the current machine (8’6”w x 6’6”d x 10’h).

• Installation: The contractor is responsible for installation, including any necessary modifications to existing utilities.

• Removal of Old Unit: Requires a forklift capable of lifting 5,000 – 15,000 lbs to remove the old machine.

• S.A.F.E. System Water Connection: 1" F.P.T. The dryer must be provided with water at a pressure of 40 PSI minimum and 100 PSI maximum.

• Double Tilt: The dryer must have both forward and backward tilt capabilities.

• Complete Installation: The service includes the full installation of the new dryer.

b. Utility Connections and Modifications: The contractor must connect the new unit to the existing utilities (gas, air, electrical). If any modifications are needed to make the connections work, the contractor is responsible for providing all necessary materials and labor from qualified technicians.

c. Relocation of Existing Equipment: The contractor is required to move the old dryer to a specified staging area within the facility.

3. POC’s: Brenda Brown; brenda.brown.9@us.af.mil-(907)854-2429, Susan Meyer;

susan.meyer.1@us.af.mil-(907)384-1903.

4. Technical acceptability may only be provided by the undersigned or designated representative.

Susan Meyer, GS-09 Assistant Laundry Manager mailto:brenda.brown.9@us.af.mil mailto:susan.meyer.1@us.af.mil-(907)384-1903

2026-06-30T12:08:23-0800
MEYER.SUSAN.ANNE.1138391228