40325 Drawings .pdf
PDF 6 MB Posted
- Attached to
- Indian Lake Road Concrete Work- Tiger Bay
- Solicitation number
- ITB-09674
- Issued by
- Polk County, Florida
About this file
This document contains drawings and specifications for the Indian Lake Road Concrete Work project in Volusia County, Florida. The work involves repairing an existing limerock roadway by constructing a 350-foot long by 22-foot wide by 8-inch-thick reinforced concrete surface to protect Indian Lake Road from erosion during wet periods. The project is managed by the St. Johns River Water Management District. The drawings provide details on the roadway section, concrete specifications, erosion and sediment control requirements, and other construction details. This is a bid set of drawings, indicating this is a contract opportunity for contractors to submit bids to perform the construction work.
The drawings indicate that the existing conditions will need to be verified by the bidding contractor, and that all necessary permits and inspections will be the responsibility of the contractor. The contractor will also be responsible for any damage caused to existing facilities during the work. Erosion and sediment control measures must be implemented, and disturbed areas restored with grass. Testing and quality control requirements for the concrete work are also specified.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 40325 Addendum 1 .pdf | ||
| IFB-40325 Tiger Bay_ FINAL.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT
LOCATION
DRAWING FILENAME:
SHEET:
DATE:
P.E. NUMBER:
CERTIFICATION:
u:
\P ro je ct s\
C
AD
D \N
C B\ tig er b ay o ve rfl ow ro ad w ay m ai nt en an ce
\0 pr od uc tio n dr aw in gs \C iv il\
C O
VE
R
S H
EE
T.
dw g
VICINITY MAP
ST. JOHNS RIVER WATER MANAGEMENT DISTRICT
NORTHERN COASTAL BASIN
INDIAN LAKE ROAD CONCRETE WORK
VOLUSIA COUNTY, FLORIDA
CAITLYN O. DRANE
85256
06/26/24 C1
COVER SHEET.dwg
A
F
CI
X
O
EM
ULF
O
G
POLK
OKEECHOBEE
INDIAN RIVER
OSCEOLA
BR
EV
AR
D
O
SC
EO
LA
VOLUSIA
SEMINOLE
ORANGE
LAKE N
BAKER
FL
AG
LE
RALACHUA
PUTNAM
MARION O
T
CI
E C
CLAY
BRADFORD
DUVAL
ST
. J
O H
N S
LT
A
A N
NASSAU
PROJECT
LOCATION
NAVD 1988
ALL ELEVATIONS DEPICTED HEREIN REFERENCE
NAVD 1988 UNLESS OTHERWISE NOTED.
NO. REVISION BY APPROVEDDATE DATE
ENGINEER'S NOTES:
1. THESE DRAWINGS ARE PREPARED FOR THE SOLE AND EXCLUSIVE USE OF
THE ST. JOHNS RIVER WATER MANAGEMENT DISTRICT AND SHALL NOT
BE RELIED UPON BY ANY OTHER ENTITY OR INDIVIDUAL.
2. REPRODUCTIONS OF THESE DRAWINGS ARE "NOT VALID WITHOUT THE
SIGNATURE AND THE ORIGINAL SEAL OF A FLORIDA LICENSED
ENGINEER."
3. THIS DOCUMENT INCLUDES MATERIALS THAT ARE EXEMPT FROM
DISCLOSURE UNDER SECTION 119.071(3)(B), FLORIDA STATUTES, WHICH
APPLIES TO, AMONG OTHERS, BUILDING PLANS, BLUEPRINTS, SCHEMATIC
DRAWINGS, AND DIAGRAMS THAT DEPICT THE INTERNAL LAYOUT AND
STRUCTURAL ELEMENTS OF A BUILDING, WATER TREATMENT FACILITY, OR
OTHER STRUCTURE OWNED OR OPERATED BY THE DISTRICT. PURSUANT TO
SECTION 119.071(3)(B)4, PLEASE HELP THE DISTRICT MAINTAIN THE EXEMPT
STATUS OF THIS DOCUMENT BY NOT MAKING IT AVAILABLE TO THE PUBLIC.
NOT TO SCALE
LOCATION MAP
FOR BID PURPOSES ONLY
NOT FOR CONSTRUCTION
DRAWING INDEX
SHEET NUMBER SHEET TITLE
C1 COVER SHEET
C2 NOTES AND DETAILS
C3 NOT USED
C4 PLAN & PROFILE STA. 0+00 TO 4+60
C5 PLAN & PROFILE STA. 4+50 TO 7+45
PROJECT INFORMATION
1. NAME OF PROJECT: INDIAN LAKE ROAD MAINTENANCE AND REPAIRS
2. PROJECT DESCRIPTION: REPAIR AND MAINTENANCE OF INDIAN LAKE ROAD
DUE TO EROSION
3. SECTION/TOWNSHIP/RANGE: 25/15/31
4. PARCEL NUMBER: 512500000010
5. PROJECT ADDRESS: 850 INDIAN LAKE RD, DAYTONA BEACH, FL 32124
CONTACT INFORMATION
1. PROPERTY OWNER: ST JOHNS RIVER WATER MANAGEMENT DISTRICT
PO BOX 1429
PALATKA, FL 32178-1429
386-329-4500
2. ENGINEER: ST JOHNS RIVER WATER MANAGEMENT DISTRICT
PO BOX 1429
PALATKA, FL 32178-1429
386-329-4500
CONTACT: CAITLYN DRANE, PE
3. SURVEYOR: ST JOHNS RIVER WATER MANAGEMENT DISTRICT
PO BOX 1429
PALATKA, FL 32178-1429
386-329-4500
CONTACT: RICHARD GUILFOYLE, PSM
00 100005000
SCALE: 1" = 5000'
BID SET C.O.D. 06/26/24 C.O.D. 06/26/241
#4 @ 36"
TIE BAR
C ROAD
SLOPE VARIES
L
11'11'
3' CLEAR (TYP.)
T/CONC. EL. T/CONC. EL.
STABILIZED SUBGRADE SEE
SUBGRADE PREPARATION
NOTES.
#4 @ 36"
TRANSVERSE
REBAR
#4 @ 15" LONGITUDINAL REBAR
CONSTRUCTION JOINT
12" 12"
JOINT SEAL (SEE S2/4)
CONCRETE
SCALE: N.T.S.
PAVEMENT SECTION
22'
2.00%
SLOPE
VARIES
SLOPE
VARIES
12" SUB-GRADE COMPACTED
TO 98% DENSITY BASED ON
AASHTO T-180 MODIFIED
PROCTOR TEST WITH MINIMUM
LBR 40 (BY OTHERS)
MATCH
EXIST.
GRADE
PROPOSED
8" CONCRETE
(4,000 PSI)
EXIST.
GRADE
CONCRETE
SCALE: N.T.S.
ROADWAY SECTION
u:
\P ro je ct s\
C
AD
D \N
C B\ tig er b ay o ve rfl ow ro ad w ay m ai nt en an ce
\0 pr od uc tio n dr aw in gs \In di an
L ak e R oa d
M &R
.d w g
DRAWN:
SCALE:
DATE:
DESIGNER:
REVIEWER:
SECTION CHIEF:REVISIONNO. BY DATE APPROVED DATE DATE:
P.E. NUMBER:
CERTIFICATION: FILE NAME:
SHEET:
PROJECT NO.:
Indian Lake Road M&R.dwg
ST. JOHNS RIVER
WATER MANAGEMENT DISTRICT
P.O. BOX 1429 PALATKA, FLORIDA
NORTHERN COASTAL BASIN
INDIAN LAKE ROAD CONCRETE WORK
VOLUSIA COUNTY, FLORIDA J.C.H. 06/26/24 A.P.W
N/A C.O.D. W.R.C.
NOTES AND DETAILS
CAITLYN O. DRANE
85256
C2
BID SET C.O.D. 06/26/24 C.O.D. 06/26/241
GENERAL NOTES
1. THE CONTRACTOR SHALL BE RESPONSIBLE TO FAMILIARIZE HIMSELF WITH THE NATURE AND EXTENT OF THE CONTRACT DOCUMENTS, SCOPE OF WORK, LOCAL CONDITIONS, ALL FEDERAL, STATE, AND LOCAL LAWS, RULES AND REGULATIONS THAT MAY AFFECT THE WORK. THE CONTRACTOR SHALL PROVIDE A GANTT CHART SCHEDULE FOR ALL THE PROPOSED WORK PRIOR TO THE
START OF CONSTRUCTION.
2. THE EXISTING CONDITIONS REPRESENTED IN THESE DRAWINGS ARE BELIEVED TO BE ACCURATE ACCORDING TO THE INFORMATION AVAILABLE TO THE DISTRICT. HOWEVER, IT IS THE SOLE RESPONSIBILITY OF THE BIDDER (CONTRACTOR) TO VERIFY ALL EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES TO THE DISTRICT PRIOR TO SUBMITTAL OF THE BID.
3. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY DAMAGE TO EXISTING FACILITIES, ABOVE OR BELOW GROUND, THAT MAY OCCUR AS A RESULT OF THE WORK PERFORMED, BY THE CONTRACTOR OR SUB-CONTRACTORS, AS CALLED FOR IN THESE
CONTRACT DOCUMENTS.
4. THE CONTRACTOR SHALL PROTECT ALL EXISTING STRUCTURES, LEVEES, ROADS, UTILITIES, AND OTHER IMPROVEMENTS FROM DAMAGE WHETHER OR NOT SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR PROTECTION METHODS, COORDINATION WITH OWNERS AND REPAIRS TO UTILITIES AND OTHER SITE IMPROVEMENTS DAMAGED DURING CONSTRUCTION. ADDITIONALLY, THE WORK WILL BE CONSIDERED COMPLETE ONLY AFTER ALL RUBBISH AND UNUSED MATERIAL DUE TO OR CONNECTED WITH THE WORK HAS BEEN REMOVED AND THE PREMISES LEFT IN A CONDITION SATISFACTORY TO THE
DISTRICT.
5. ALL PROPERTY DISTURBED OR DAMAGED DURING THE WORK SHALL BE RESTORED TO ITS FORMER CONDITION OR BETTER
CONDITION AT NO ADDITIONAL EXPENSE TO THE DISTRICT.
6. IT IS THE CONTRACTOR'S RESPONSIBILITY TO BECOME FAMILIAR WITH THE PERMIT AND INSPECTION REQUIREMENTS SPECIFIED BY THE VARIOUS GOVERNMENTAL AGENCIES AND THE ENGINEER. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION AND SCHEDULE INSPECTIONS ACCORDING TO AGENCY INSTRUCTION/REQUIREMENTS.
7. THE CONTRACTOR SHALL CONDUCT ALL CONSTRUCTION OPERATIONS IN A MANNER WHICH DOES NOT CAUSE VIOLATIONS OF STATE WATER QUALITY STANDARDS. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES (SILT FENCE, TURBIDITY BARRIER, ETC.) AS REQUIRED FOR COMPLIANCE WITH FEDERAL, STATE, AND LOCAL LAWS, RULES, AND
REGULATIONS.
8. CONTRACTORS BID AND SCHEDULE SHALL INCLUDE DOWNTIME AS A RESULT OF NORMAL SEASONAL RAINFALL CONDITIONS, AND
ONLY TIME EXTENSIONS WILL BE CONSIDERED AS A RESULT OF EXTREME WEATHER EVENTS.
9. THE CONTRACTOR SHALL NOTIFY THE DISTRICT PROJECT MANAGER A MINIMUM OF 48 HOURS PRIOR TO THE START OF
CONSTRUCTION.
10. CONSTRUCTION INSPECTION WILL BE PERFORMED BY THE DISTRICT. THE CONTRACTOR SHALL NOTIFY THE DISTRICT AT LEAST 48
HOURS PRIOR TO THE REQUIRED TIME OF INSPECTION FOR EACH AND EVERY PHASE OF WORK.
11. THE CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF CONTRACT DOCUMENTS INCLUDING DRAWINGS AND SPECIFICATIONS AT THE JOB SITE CLEARLY MARKED TO REFLECT ALL AS-BUILT CONDITIONS. UPON COMPLETION OF THE PROJECT, THE CONTRACTOR
SHALL SUBMIT THESE ANNOTATED DRAWINGS AND SPECIFICATIONS TO THE DISTRICT.
12. TRAFFIC CONTROL / ROADWAY CLOSURE WILL BE COMPLETED BY OTHERS.
CONCRETE NOTES:
1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE FLORIDA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, LATEST EDITION, UNLESS OTHERWISE NOTED. PERTINENT FDOT MATERIAL
SPECIFICATION SECTIONS INCLUDE THE FOLLOWING:
SECTION 346 - PORTLAND CEMENT CONCRETE
SECTION 350 - CEMENT CONCRETE PAVEMENT
SECTION 415 - REINFORCING STEEL
SECTION 925 - CURING MATERIALS FOR CONCRETE
2. ALL CONCRETE SHALL ATTAIN A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 4,000 PSI. PORTLAND CEMENT SHALL BE TYPE II IN ACCORDANCE WITH ASTM C-150. CONCRETE SHALL BE AIR ENTRAINED WITH TOTAL AIR AS PERCENT BY VOLUME OF CONCRETE EQUAL TO 4%. THE AIR ENTRAINING ADMIXTURE SHALL BE MICRO AIR, AS MANUFACTURED BY MASTER BUILDERS, OR EQUAL, CONFORMING TO ASTM C-260. THE AGGREGATES SHALL CONFORM TO ASTM C-33 AND SHALL HAVE A 3/4-INCH MAXIMUM SIZE.
3. REINFORCING STEEL SHALL BE GRADE 60 DEFORMED BILLET STEEL BARS CONFORMING TO ASTM A-615.
4. THE MINIMUM CLEAR CONCRETE COVER FOR REINFORCEMENT SHALL BE 3 INCHES EXCEPT WHERE CAST AGAINST EARTH THE
MINIMUM CLEAR COVER SHALL BE 3.5 INCHES.
5. REINFORCEMENT SPLICES WHERE THE LENGTHS ARE NOT INDICATED SHALL BE AS FOLLOWS:
BAR SIZE SPLICE LENGTH (IN)
#4 24
6. THE CONTROL JOINTS SHALL BE EXTENDED AS IS CURRENTLY CONSTRUCTED.
7. TESTING:
TESTING LABORATORY: CONTRACTOR SHALL RETAIN AN INDEPENDENT TESTING LABORATORY TO FUNCTION AS ITS REPRESENTATIVE IN THE SAMPLING AND TESTING OF CONCRETE FURNISHED. THE LABORATORY'S INSPECTORS SHALL HAVE FREE ACCESS TO ALL POINTS
WHERE CONCRETE MATERIALS ARE STORED, PROPORTIONED, MIXED, OR PLACED.
TESTING FREQUENCY: FOR EACH 100 CY OF POURED CONCRETE THE LABORATORY SHALL TAKE A SAMPLE FROM A BATCH OF ITS SELECTION AS THE CONCRETE IS BEING PLACED. NO WATER SHALL BE ADDED, OR OTHER CHANGE MADE IN ANY BATCH AFTER IT HAS BEEN SAMPLED. IN ADDITION TO OTHER TESTS, THE LABORATORY WILL MAKE A SET OF THREE (3) STANDARD COMPRESSION CYLINDERS FROM EACH SAMPLE, ONE (1) OF WHICH WILL BE TESTED AT SEVEN (7) DAYS AND TWO (2) TESTS AT TWENTY-EIGHT (28)
DAYS. CONTRACTOR WILL BE FURNISHED WITH A REPORT OF EACH TEST MADE.
COMPRESSION STRENGTH OF A SAMPLE SHALL BE DETERMINED BY THE AVERAGE OF THE TWO (2) CYLINDERS TESTED AT TWENTY-EIGHT (28) DAYS. COMPLIANCE WITH THE STRENGTH REQUIREMENTS OF THESE SPECIFICATIONS SHALL BE VERIFIED IF THE STRENGTH TEST RESULT DOES NOT FALL BELOW THE SPECIFIED STRENGTH BY MORE THAN FIVE HUNDRED (500) PSI. CONCRETE WHICH FAILS TO MEET STRENGTH REQUIREMENTS MAY BE FURTHER TESTED AS PROVIDED IN ACI 318 AT THE EXPENSE OF CONTRACTOR OR
SHALL BE REMOVED AS DETERMINED BY DISTRICT'S PROJECT MANAGER.
EROSION AND SEDIMENT CONTROL (BY OTHERS):
1. THE CONTRACTOR IS RESPONSIBLE FOR REMOVING SILT FROM SITE IF NOT REUSABLE ON-SITE AND ASSURING PLAN
ALIGNMENT AND GRADE IN ALL WORK AT COMPLETION OF CONSTRUCTION.
2. ON-SITE PROTECTION IN ADDITION TO THE ABOVE MUST BE PROVIDED THAT WILL NOT PERMIT SILT TO LEAVE THE
PROJECT CONFINES DUE TO UNSEEN CONDITIONS OR ACCIDENTS.
3. THE FILTER BARRIER SHALL BE ENTRENCHED AND BACKFILLED. A TRENCH SHALL BE EXCAVATED TO A MINIMUM DEPTH OF 8 INCHES. THE EXCAVATED SOIL SHALL BE BACKFILLED AND COMPACTED AGAINST THE FILTER BARRIER.
4. SILT FENCES AND FILTER BARRIERS SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY
DURING PROLONGED RAINFALL. ANY REQUIRED REPAIRS SHALL BE MADE IMMEDIATELY.
5. SHOULD THE FABRIC ON A SILT FENCE OR FILTER BARRIER DECOMPOSE OR BECOME INEFFECTIVE PRIOR TO THE END OF THE EXPECTED USABLE LIFE AND THE BARRIER STILL BE NECESSARY, THE FABRIC SHALL BE REPLACED IMMEDIATELY.
6. ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE SILT FENCE OR FILTER BARRIER IS NO LONGER REQUIRED
SHALL BE DRESSED TO CONFORM WITH THE EXISTING GRADE, PREPARED AND GRASSED.
7. THE CONTRACTOR IS RESPONSIBLE FOR FOLLOWING THE BEST EROSION AND SEDIMENT CONTROL PRACTICES AS OUTLINED IN THE PLANS, SPECIFICATIONS, PERMITS, AND ST. JOHNS RIVER WATER MANAGEMENT DISTRICT CRITERIA.
8. FOR ADDITIONAL INFORMATION ON SEDIMENT AND EROSION CONTROL REFER TO STATE OF FLORIDA EROSION AND
SEDIMENT CONTROL DESIGNER AND REVIEWER MANUAL (LATEST EDITION).
9. ALL DISTURBED AREAS SHALL BE GRASSED, FERTILIZED, WATERED AND MAINTAINED UNTIL A PERMANENT VEGETATIVE COVER IS ESTABLISHED. GRASSING SHALL CONFORM TO THE REQUIREMENTS OF SECTIONS 570 AND 981 THRU 983 OF THE FDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION (LATEST EDITIONS). NOTE THAT OTHER
GRASSING ALTERNATIVES MAY BE USED WITH PRIOR DISTRICT APPROVAL.
FOR BID PURPOSES ONLY
NOT FOR CONSTRUCTION
Elevation
0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+504+60
2.48% 0.16%
-3.67%
-3.76% -1.00% 0.00% -0.00% 0.00%
0+07.19
1+
2+
3+
4+
0+
1+
2+
3+
4+
12" SUB-GRADE COMPACTED
TO 98% DENSITY BASED ON
AASHTO T-180 MODIFIED
PROCTOR TEST WITH MINIMUM
LBR 40
(BY OTHERS)
CONTRACTOR TO REGRADE
PORTION OF EXIST. LIMEROCK
ROAD.
PROPOSED 8" LIMEROCK (MIN.)
LBR 40
(BY OTHERS)
MATCH EXIST.
GRADE AT
BRIDGE
PROPOSED
GRADE
CONTRACTOR TO REGRADE
PORTION OF EXIST. LIMEROCK
ROAD.
PROPOSED 8" LIMEROCK (MIN.)
LBR 40
(BY OTHERS)
CENTERLINE
PROPOSED
8" CONCRETE
(4,000 PSI)
32.16
31.75
31.89
31.92
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOWEOWEOWEOWEOWEOWEOWEOWEOWEOWEOW
18" OAK
24" OAK
24" TWIN OAK
EXIST.
WOODEN
BRIDGE
UGE
UGE
UGE
UGE UGE UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
WM
WM
WM
WM WM WM
WM
WM
WM
WM
WM
WM
WM
WM
UGT
UGT
UGT
UGT UGT UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
OHW
OHW
OHW
OHW
OHW
OHW
OHW
OHW
OHW
OHW
OHW
35.75
22'
0+00
1+00 2+00 3+00
4+00
5+00
35.72
35.7035.04
34.9534.52
34.61 32.60
32.98
32.49
EXIST. 6-FT HIGH
CHAIN LINK FENCE
ACCESS BARRIER
WITH HAZARD
WARNING SIGNAGE
EXIST.
WOOD
RETAINING
WALL
35.79
35.77
35.79
33.81
33.91
34.00 32.25
32.03
31.81 31.56
31.78
32.00
32.00
31.78
31.56
32.00
31.78
31.56
32.00
31.78
31.56
32.00
31.78
31.56 31.56
31.78
32.0032.00
31.78
31.56
31.50
31.56 31.56
31.56 31.78
31.7831.78
32.00 32.00 32.00
31.50
16'18'20'
REGRADE PORTION OF EXIST.
LIMEROCK ROAD. ADD
LIMEROCK AS NEEDED. (BY
OTHERS)
MATCH EXIST. GRADE AT
EXIST. LIMEROCK ROAD
(BY OTHERS)
31.31 31.31
31.50 31.50
31.31
31.31
31.06 31.06
16'
22'
ALIGNMENT=CENTERLINE PROFILE
STATION=2+51.78
OFFSET=0.00
NORTHING=1756475.72
EASTING=606944.81
ALIGNMENT=CENTERLINE PROFILE
STATION=3+35.36
OFFSET=0.00
NORTHING=1756448.04
EASTING=607023.66
ALIGNMENT=CENTERLINE PROFILE
STATION=4+35.47
OFFSET=0.00
NORTHING=1756401.43
EASTING=607112.26
ALIGNMENT=CENTERLINE PROFILE
STATION=5+34.70
OFFSET=0.00
NORTHING=1756346.99
EASTING=607195.22
ALIGNMENT=CENTERLINE PROFILE
STATION=6+35.30
OFFSET=0.00
NORTHING=1756285.71
EASTING=607275.00
EXIST.
GUARD
RAIL
EXIST.
GUARD
RAIL
+/- 45-FT
UTILITY EASEMENT
APPROX. LOCATION
OF EXIST.
APPROX. LOCATION
OF RIGHT-OF-WAY
GRADE AND SOD 5-FT BAND ON
EACH SIDE OF THE CONCRETE
ROADWAY TO ENSURE
POSITIVE DRAINAGE ACROSS
THE ROADWAY BETWEEN STA.
2+51.78 AND STA. 6+01.75. (BY
OTHERS)
UTILITY POLE
(TYP.)
REGRADE EXIST. LIMEROCK
ROAD AND ADD LIMROCK AS
NEEDED. (BY OTHERS)
EXIST. 6-FT HIGH
CHAIN LINK FENCE
ACCESS BARRIER
WITH HAZARD
WARNING SIGNAGE
CONSTRUCT 8"
REINFORCED
CONCRETE ROADWAY
FOR BID PURPOSES ONLY
NOT FOR CONSTRUCTION
GRAPHIC SCALE
u:
\P ro je ct s\
C
AD
D \N
C B\ tig er b ay o ve rfl ow ro ad w ay m ai nt en an ce
\0 pr od uc tio n dr aw in gs \In di an
L ak e R oa d
M &R
.d w g
DRAWN:
SCALE:
DATE:
DESIGNER:
REVIEWER:
SECTION CHIEF:REVISIONNO. BY DATE APPROVED DATE DATE:
P.E. NUMBER:
CERTIFICATION: FILE NAME:
SHEET:
PROJECT NO.:
Indian Lake Road M&R.dwg
ST. JOHNS RIVER
WATER MANAGEMENT DISTRICT
P.O. BOX 1429 PALATKA, FLORIDA
NORTHERN COASTAL BASIN
INDIAN LAKE ROAD CONCRETE WORK
VOLUSIA COUNTY, FLORIDA J.C.H. 06/26/24 A.P.W
1:20 C.O.D. W.R.C.
PLAN AND PROFILE STA. 0+00 TO 4+60
CAITLYN O. DRANE
85256
06/26/24 C4
BID SET C.O.D. 06/26/24 C.O.D. 06/26/241
SCALE: 1" = 20'
20 40
4+50 5+00 5+50 6+00 6+50 7+00 7+45
12" SUB-GRADE COMPACTED
TO 98% DENSITY BASED ON
AASHTO T-180 MODIFIED
PROCTOR TEST WITH MINIMUM
LBR 40
(BY OTHERS)
CONTRACTOR TO REGRADE
PORTION OF EXIST. LIMEROCK
ROAD.
PROPOSED 8" LIMEROCK (MIN.)
LBR 40
(BY OTHERS)
PROPOSED
8" CONCRETE
(4,000 PSI)
EXISTING GRADEPROPOSED
GRADE
MATCH EXIST. GRADE AT
EXIST. LIMEROCK ROAD
(BY OTHERS)
CENTERLINE
PROFILE
5+ 00 6+
7+
-0.00% 0.00% 1.00% 1.02% -0.64%
32.96
32.56 32.16
EOWEOWEOWEOWEOWEOWEOWEOWEOWEOWEOWEOWEOWEOWEOWEOWEOWEOWEOWEOWEOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
EOW
SILT FENCE
(TYP.) REFER
TO SHEET C2
FOR SILT FENCE
DETAIL
(BY OTHERS)
UGE
UGE UGE UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
WM WM WM
WM
WM
WM
WM
WM
WM
WM
UGT UGT UGT
UGT
UGT
UGT
UGT
UGT
UGT
UGT
OHW
OHW
OHW
OHW
OHW
OHW
OHW
OHW
OHW
OHW
OHW
OHW
UTILITY POLE
(TYP.)
+/- 45-FT
UTILITY EASEMENT
APPROX. LOCATION
OF EXIST. WATER
MAIN
APPROX. LOCATION
OF EXIST.
UNDERGROUND
ELECTRIC
APPROX. LOCATION
OF EXIST.
UNDERGROUND
TELEPHONE LINE
APPROX. LOCATION
OF RIGHT-OF-WAY
3+00
4+00 5+00
6+00
7+00
7+45
32.00
31.78
31.56
32.00
31.78
31.56
32.00
31.78
31.56
32.00
31.78
31.56 31.56
31.78
32.0032.00
31.78 31.56
31.50
31.56 31.56
31.56
31.78 31.78
31.78
32.00
32.00 32.00
31.50
32.00
32.50
32.28
32.06
31.56 31.86
32.41
32.62
32.83
32.02
32.20
32.38
REGRADE PORTION OF EXIST. LIMEROCK
ROAD. ADD LIMEROCK AS NECESSARY. (BY
OTHERS)
MATCH EXIST.
GRADE AT
EXIST. LIMEROCK
ROAD (BY OTHERS)
31.31
31.31
31.5031.50
31.3131.31
31.06 31.06
GRADE AND SOD 5-FT BAND ON
EACH SIDE OF THE CONCRETE
ROADWAY TO ENSURE
POSITIVE DRAINAGE ACROSS
THE ROADWAY BETWEEN STA.
2+51.78 AND STA. 6+01.75. (BY
OTHERS)
UTILITY POLE
NORTHING=1756475.72
EASTING=606944.81 ALIGNMENT=CENTERLINE PROFILE
STATION=3+35.36
OFFSET=0.00
NORTHING=1756448.04
EASTING=607023.66
ALIGNMENT=CENTERLINE PROFILE
STATION=4+35.47
OFFSET=0.00
NORTHING=1756401.43
EASTING=607112.26
ALIGNMENT=CENTERLINE PROFILE
STATION=5+34.70
OFFSET=0.00
NORTHING=1756346.99
EASTING=607195.22
ALIGNMENT=CENTERLINE PROFILE
STATION=6+01.75
OFFSET=0.00
NORTHING=1756306.16
EASTING=607248.41
ALIGNMENT=CENTERLINE PROFILE
STATION=6+35.30
OFFSET=0.00
NORTHING=1756285.71
EASTING=607275.00 ALIGNMENT=CENTERLINE PROFILE
STATION=7+01.77
OFFSET=0.00L
NORTHING=1756236.67
EASTING=607319.89
CONSTRUCT 8"
REINFORCED
CONCRETE ROADWAY
CONSTRUCT 8"
REINFORCED
CONCRETE ROADWAY
FOR BID PURPOSES ONLY
NOT FOR CONSTRUCTION
GRAPHIC SCALE
SCALE: 1" = 20'
20 40 u:
\P ro je ct s\
C
AD
D \N
C B\ tig er b ay o ve rfl ow ro ad w ay m ai nt en an ce
\0 pr od uc tio n dr aw in gs \In di an
L ak e R oa d
M &R
.d w g
DRAWN:
SCALE:
DATE:
DESIGNER:
REVIEWER:
SECTION CHIEF:REVISIONNO. BY DATE APPROVED DATE DATE:
P.E. NUMBER:
CERTIFICATION: FILE NAME:
SHEET:
PROJECT NO.:
Indian Lake Road M&R.dwg
ST. JOHNS RIVER
WATER MANAGEMENT DISTRICT
P.O. BOX 1429 PALATKA, FLORIDA
NORTHERN COASTAL BASIN
INDIAN LAKE ROAD CONCRETE WORK
VOLUSIA COUNTY, FLORIDA J.C.H. 06/14/24 A.P.W
1:20 C.O.D. W.R.C.
PLAN & PROFILE STA. 4+50 TO 7+45
CAITLYN O. DRANE
85256
06/14/24 C5
BID SET C.O.D. 06/14/24 C.O.D. 06/14/241
File details come from the government source that posted it. Updated .