This document is Addendum 03, dated October 23, 2026, issued by Holly & Smith Architects, APAC for the Maritime Aquatics Facility project at Delgado Community College in New Orleans, Louisiana. The addendum modifies the original bid documents for Project No. 25037 and must be acknowledged by all bidders on their bid forms. The addendum provides three key clarifications and modifications: (1) decorative metal fences and gates specifications, with sizing details referenced in the door schedule on sheet A301 and specification section 323119, with colors to be selected by the Architect during the submittal process and installation shown on drawing 18 of sheets A711 and A301; (2) an addition of 100 linear feet of 1-inch propane line to connect to Delgado's propane tank, with exact location to be determined at a future date, as referenced in Sheet M101, Note 6; and (3) replacement of the original Sheet A101 dated July 2, 2026 with a revised version dated October 23, 2026, which includes a new drawing 20 depicting a light pole foundation detail. The revised site plan shows the facility layout including the training pool, pool deck, pool equipment area, existing buildings and easements, and light pole foundations with specific setbacks and elevation details relative to Saturn Boulevard.

No pricing information, set-asides, incumbent contractors, funding sources, or bond requirements are detailed in this addendum document. The addendum serves solely as a modification to the contract documents and does not establish contract pricing, payment terms, or special bidding provisions. Bidders are required to incorporate all clarifications and modifications into their bid submissions and cost estimates.

View the file

Other files

File Type Posted
40006-R0031602-2.pdf PDF
40006-R0031602-1.pdf PDF
40006-R0031602.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HOLLY & SMITH ARCHITECTS, APAC 208 NORTH CATE ST. / HAMMOND, LA 70401

2302 MAGAZINE ST. / NEW ORLEANS, LA 70130

HOLLYANDSMITH.COM 100 E. VERMILION ST. , SUITE 406 / LAFAYETTE, LA 70501

MARITIME AQUATICS FACILITY

DELGADO COMMUNITY COLLEGE

Addendum 03

H/S Project: 25037

Date: 10.23.2026

This Addendum forms a part of the Contract Documents and modifies the original specifications and drawings issued for bidding to the extent noted hereinafter. All other provisions of the Bid Documents shall remain unchanged.

Careful note of this Addendum will be taken by all parties of interest so that proper allowances are made in all computations, estimates and contracts and so that all trades affected are fully advised in the performance of the work that will be required of them. Acknowledge receipt of this Addendum on the Bid Form.

Clarifications

1.01 Decorative Metal Fences and Gates: See door schedule on sheet A301 for gates’ sizing. See specification section 323119 – Decorative Metal Fences and Gates for fence’s post, rail, & picket sizing and gate’s frame, diagonal bracing, & post sizing. See mentioned spec section for fence and gate materials and finishes. Fence and gate colors to be selected by Architect through the submittal process. The fencing will be installed as shown in drawing 18 on sheet A711 and the gates will be installed on the slab as shown in drawing 18 on sheet A301.

1.02 Propane Line: Refer to Sheet M101, Note 6. Include 100 additional linear feet of 1 ½” propane line to connect to Delgado’s propane tank(s). Exact location is to be decided at a future date.

Modifications to the Drawings

Sheet A101

1.03 Refer to Sheet A101. Delete original bid document sheet dated 07/02/2026 in its entirety and inset the revised Sheet A101, enclosed herein as part of this Addendum dated 10/23/26.

Clarification: Added drawing 20 which is a light pole foundation detail.

END OF ADDENDUM

FR

O

M P

RO

PE

RT

Y

LI

NE

SE

TB

AC

K

0"

SETBACK

20' - 0"

SE

TB

AC

K

EX

IS

TI

N

G B

U

IL

D

IN

G

EXISTING BUILDING

EX

IS

TI

NG

D

RA

IN

AG

E

EA

SE

M

EN

T

EX

IS

TI

NG

E

AS

EM

EN

T

0"

'-0

100'-0"

LAYOUT POINT FOR THE E/W AXIS

35'-0" FROM ADJACENT BUILDING

8'- 0" ± -0' - 6" , V.I.F.

ALIGN3212 0231

FINISH SLAB ELEVATION 0'-0" = 0.84 NAVD 88

SA

TU

RN

B

LV

D

12'-4"

0' - 0" -0' - 1 1/2"

0' - 0"

-0' - 1 1/2"

-0' - 1 1/2"

0' - 0"

0' - 0"

0' - 0" -0' - 1 1/2" 0' - 0"

0' - 0"

13'-3"

TY

P

5'- 0"

13'-3"73'-6"

TRAINING POOL POOL DECKPOOL EQUIP.

-0' - 1 1/4"

-0' - 1 1/4"

-0' - 1 1/4"

26012601

2601 2601

REQ'D RIP RAP, SEE CIVIL REQ'D RIP RAP, SEE CIVIL

POOL, TRAINING PLATFORM,

TOILET ROOMS, & EQUIPMENT

SLAB ARE SYMMETRICAL ABOUT

THIS CENTERLINE.

LA

YO

UT

P

O

IN

T

FO

R

TH

E N/

S

AX

IS

4'-

0"

THIS WALL SHALL BE PARALLEL TO THE

WEST WALL OF THE EXISTING BUILDING.

C L

-0' - 1 3/8"

-0' - 1 3/8"

-0' - 1 3/8"

-0' - 1 3/8"

-0' - 1 1/4"

GRAPHIC LEGEND

EXISTING GRASS

(NEW GRASS IN AREAS REGRADED, SEE CIVIL)

EXISTING ROCK BOULDER BED

EXISTING SIDEWALK

EXISTING GRAVEL

CONCRETE

EXISTING DIRT

KOOLDECK

CL LIGHT POLE

ALIGNALIGN

9" 9"

FOR ADJACENT

CONDITION, SEE

SITE PLAN

FOR ADJACENT

CONDITION,

SEE SITE PLAN

SCHEDULED LIGHT STANDARD

BASE PLATE AND ANCHOR BOLTS

(SEE MANUF. REQUIREMENTS)

CONCRETE

SPREAD FOOTING

2'-0" 2'-0"

#4 @ 12" O.C.

EACH WAY MIN.

�4 '-0

1'-

0"

PROJECT NO.

DATE

This drawing, as an instrument of service, is and shall remain the property of the Architect and shall not be reproduced, published, or used in any way without the permission of the Architect.

© Holly & Smith Architects, APAC

PROJECT MANAGER

PHASE

QUALITY CONTROL

DESCRIPTION DATENO.

1"

0" 1"½"

½"

The graphic scale at the bottom left corner of this drawing must measure 1"x1" otherwise all listed scales are null and void.

HOLLY & SMITH

ARCHITECTS

HAMMOND

T 9 8 5 . 3 4 5 . 5 2 1 0 www.hollyandsmith.com

NEW ORLEANS

T 5 0 4 . 5 8 5 . 1 3 1 5

LAFAYETTE

T 3 3 7 . 2 7 9 . 2 0 1 0

Au to de sk

D oc s:

//D el ga do C om m un ity

C ol le ge

M ar iti m e Aq ua tic s/

7-

D M

A.

rv t

/2 3/

1:

:3

AM

A101

SITE

H/S #: 25037

07/02/2026

RS

BD

BID

DOCUMENTS

O

LD

G

E N

TI

LL

Y R

O A

D N

E W

O

RL

E A

N S, L A

M A

RI

TI

M E

A Q

U A

TI

C

S

FA

C

IL

IT

Y

D E

LG

A

D O

C O

M M

U N

IT

Y

C O

LL

E

G E

KEYNOTE LEGEND

0001 PROPERTY LINE

0212 EXISTING FENCE TO REMAIN

0231 EXISTING CONCRETE SIDEWALK, V.I.F.

2601 LIGHT FIXTURE; RE: ELECTRICAL

3212 CAST-IN-PLACE CONCRETE SIDEWALK, REFER TO CIVIL

N

PLAN

NORTH

1/8" = 1'-0"16 SITE PLAN

3/4" = 1'-0"20 LIGHT POLE FOUNDATION

3 ADDENDUM 03 10/23/26

File details come from the government source that posted it. Updated .