4-SIDA Fence Zone 2 replacement - Bid Specifications.docx
DOCX document 15 KB Posted
- Solicitation number
- ITB-2025-Fence SIDA Zone 2 replacement for Milwaukee County Mitchell International Airport
- Issued by
- Milwaukee County, Mattoon Village, Wisconsin
About this file
This document is a bid specification for a fence replacement project at Milwaukee County Mitchell International Airport in Wisconsin. The project involves furnishing and installing approximately 550 linear feet of SIDA (Secure Identified Designated Area) fence, which will be 10 feet high with an additional 3-wire barbed wire mounted on a 2-foot barbed wire arm. The specification includes 2 feet of below-grade chain link and backfill, with an exception for areas crossing asphalt or concrete that require a bottom tension bar. Line posts will be driven 60 inches deep, and terminal posts will be set in 12" x 60" concrete footings. The project also includes the removal and disposal of approximately 675 feet of existing SIDA fence, including two swing gates.
The bid specifications do not provide detailed pricing information, funding sources, or specific bidding dates. The technical requirements emphasize precise installation methods, including tension wire and bracing where needed, and specific installation techniques for different surface types. The project appears to be focused on security infrastructure improvement at the airport, with careful attention to fence construction details that meet security standards for a sensitive airport zone.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 5-Zone 2 Map.pdf | ||
| 6-Milwaukee County Terms and Conditions.pdf | ||
| 3-Fence specifications example.png | PNG image | |
| 2-Bid Prerequisite Requirements Fence GMIA.docx | DOCX document | |
| 1-Insurance Requirements Form.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SIDA Fence Zone 2 replacement specifications:
· Furnish and install approximately 550’ of SIDA Fence (to match existing)
· 10’ high with additional 3 wire barbed wire mounted on a 2’ barbed wire arm and 2’ of below grade chain link and back fill
· Exception to 2’ below grade mesh when crossing asphalt or concrete areas which requires a bottom tension bar
· Line posts driven 60” and terminal posts to be set in concrete footings (12” x 60”).
· Tension wire and bracing where required
· Removal and disposal of approximately 675’ of existing SIDA fence which includes to swing gates
· Footage removal and back filling.