4-251126 Wissahickon FC Window Repl BID SET 025 037.2.pdf
PDF 4 MB Posted
- Solicitation number
- Not on record
- Issued by
- Montgomery County, Allentown City, Pennsylvania
About this file
This is a bid set cover sheet and architectural drawing document for the Borough of Ambler, Pennsylvania, in connection with window replacement work at the Wissahickon Fire Company Station located at 245 Race Street, Ambler, PA 19002. The project involves the replacement and installation of windows at the fire station facility. Sealed bids for this contract (26-01) are being received online through the PennBid Program, with a bid submission deadline of 10:00 A.M. on February 27, 2026. All work must be completed in accordance with the Project Manual and Drawings, which are available at no cost through PennBid at https://pennbid.bonfirehub.com. The project is subject to Pennsylvania's Act 442 prevailing wage requirements and prevailing minimum wage rates issued by the Pennsylvania Department of Labor and Industry. Bidders may not withdraw their bids within sixty days after the bid opening date.
The document includes comprehensive architectural specifications, drawing lists, and general construction notes prepared by Phillips Associates Architects, with support from civil engineer Charles E. Shoemaker, Inc., and structural engineer GTA, Inc. The bid set is designated as CS1 and dated November 26, 2025. The Borough of Ambler reserves the right to reject any or all bids for any cause, to eliminate items from the contract, and to waive any informality in the bidding process. Contractors are required to verify all field dimensions, obtain all necessary permits prior to construction commencement, coordinate inspections with municipal authorities, and comply with applicable building codes including the 2018 International Building Code and 2009 ICC A117.1 accessibility standards.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1-AWWTP - 2026-2027 Chemical Bid.pdf | ||
| 3-2026-02.01 WFC Part 1.pdf | ||
| 2-2026-02.01 WFC Part 2.pdf | ||
| 1-2026-02.01 WFC Part 3.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WISSAHICKON FIRE COMPANY
87 East Butler Avenue Ambler, PA 19002 p:215.646.7878 www.pa-arch.com a r c h i t e c t s / i n t e r i o r s / p l a n n e r s phillips associates
Owner:
Abbreviations:
Contact Information: Drawing List:Project Information:
Symbol Key:
Disclaimer:
1. CONTRACTORS MUST CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS IN FIELD. ANY DISCREPANCIES SHALL BE REPORTED TO
THE ARCHITECT IMMEDIATELY.
2. PLANS, SPECIFICATIONS, REPORTS, DOCUMENTS, OR OTHER INFORMATION RECORDED ON OR TRANSMITTED AS ELECTRONIC MEDIA ARE SUBJECT TO UNDETECTABLE ALTERATION, EITHER INTENTIONAL OR UNINTENTIONAL, DUE TO, AMONG OTHER CAUSES, TRANSMISSION, CONVERSION, MEDIA DEGRADATION, SOFTWARE ERROR OR HUMAN ALTERATION. ALL SUCH DOCUMENTS ARE PROVIDED FOR INFORMATIONAL PURPOSES ONLY AND NOT AS AN END PRODUCT NOR AS A RECORD DOCUMENT. ANY RELIANCE THEREON IS DEEMED
TO BE UNREASONABLE AND UNENFORCEABLE.
3. ALL DRAWINGS, SPECIFICATIONS, AND RELATED DOCUMENTS ARE COPYRIGHT OF THE ARCHITECT AND MUST BE RETURNED UPON REQUEST. REPRODUCTION OF DRAWINGS, SPECIFICATIONS, AND RELATED DOCUMENTS IN PART OR WHOLE IS FORBIDDEN WITHOUT THE
ARCHITECTS WRITTEN PERMISSION.
4. THE EXISTING CONDITIONS INDICATED ON THESE PLANS ARE BASED ON VISUAL OBSERVATIONS ONLY. NO INVASIVE, DESTRUCTIVE OR ELECTRONIC MEANS HAVE BEEN UTILIZED TO DETERMINE CONDITIONS THAT ARE NOT VISIBLE TO THE NAKED EYE OR APPARENT IN THE EXERCISE OF DUE DILIGENCE. ANY THIRD PARTY USING OR RELYING UPON THESE PLANS AND THE INFORMATION INDICATED THEREON, DOES SO AT ITS OWN RISK.
SPEC.
SIM.
STL.
STD.
SQ.
STOR.
STEEL
STANDARD
SQUARE
SPECIFICATION
SIMILAR
STORAGE
THK.
TEL.
T.O.
SUSP.
W.
V.I.F.
VERT.
U.O.N.
TYP.
THICK
TELEPHONE
TOP OF
SUSPENDED
WEST
VERIFY IN FIELD
VERTICAL
UNLESS OTHERWISE NOTED
TYPICAL
G.B.
FT.
GC
GL.
G.A.
H.C.
GLASS
GAUGE
GRAB BAR
FEET
HOLLOW CORE
GENERAL CONTRACTOR
HT.
HVAC
JT.
LT.
MAX.
MECH.
MAXIMUM
LIGHT
MECHANICAL
HEIGHT
AND AIR CONDITIONING
HEATING, VENTILATION,
JOINT
HORIZONTALHORIZ.
WITH
WP
WC
W/O
W/
WD.
WEATHER PROOF
WITHOUT
WOOD
MTL.
MISC
MIN.
N.T.S.
N.I.C.
N.
MISCELLANEOUS
METAL
MINIMUM
NOT TO SCALE
NOT IN CONTRACT
NORTH
PLATE
OPPOSITE
PLASTIC LAMINATE
PLASTER
PAINTED
PLYWOOD
PL.
P. LAM
OPP.
PLAS.
PTD.
PLYWD.
MANUFACTURERMFR.
WATER CLOSET, WALL COVERING
REFRIGERATOR
RADIUS
QUARRY TILE
ROOM
REQUIRED
QT.
REF.
RAD.
RM.
REQ.
SOLID CORE
SOUTH
RAINWATER CONDUCTOR
SCHEDULE
STAINLESS STEEL
RWC
S.C.
S.
SCHED.
S/S
L
A.F.F.
ADJ.
C
AT
ABOVE FINISH FLOOR
ADJUSTABLE
POUND OR NUMBER
CENTERLINE
ARCH.
AL.
BLDG.
BM.
BLKG.
BOT.
ARCHITECTURAL
ALUMINUM
BOTTOM
BEAM
BLOCKING
BUILDING
CER.
CAB.
CLG.
CONC.
COL.
CLO.
CLKG.
CONCRETE
COLUMN
CLOSET
CAULKING
CEILING
CERAMIC
CABINET
CT
CPT
DBL.
CONT.
DR.
DN.
DIM.
DIA.
DOOR
DOWN
CERAMIC TILE
CONTINUOUS
CARPET
DIAMETER
DOUBLE
DIMENSION
EX
DWG.
DTL.
EXISTING
DRAWING
DETAIL
EQ.
F.O.
F.S.
F.O.F.
FL.
FIN.
EQUAL
FACE OF
FLOOR
FINISH
FRAME SIZE
FACE OF FINISH
DOWNSPOUTDS.
CENTERCTR.
EQUIP. EQUIPMENT
FIXT. FIXTURES
VINYLVYL.
MILLWORKMLWK.
ON CENTERO.C.
B.O. BOTTOM OF
CONTR. CONTRACTOR
GLAZ. GLAZING
ROUGH OPENINGRO.
COORD. COORDINATE
DL. DAMP LOCATIONS MT. MARBLE THRESHOLD
HANGING ROD & SHELF ABOVER/S
WR WATER RESISTANT
GFI GROUND FAULT PROTECTED
EL.
ELEC. ELECTRICAL
ELEVATION
PA
R eg is tra tio n:
R
A0
7X
PROJECT ADDRESS: 245 RACE STREET
AMBLER, PA 19002
TOWNSHIP: BOROUGH OF AMBLER
COUNTY: MONTGOMERY
CLIMATE ZONE: ZONE 4A
ZONING: DC - DOWNTOWN COMMERCIAL
BUILDING CODES: IBC 2018
2009 ICC A117.1
IEBC 2018
WFC WINDOW REPLACEMENT
REF: 025 037.2
245 Race Street, Ambler, PA 19002
BID SET CS1
26 NOVEMBER 2025
SST. SIMPSON STRONG TIE
PRESERVATIVE TREATEDP.T.
DW. DISH WASHER
ROOM ELEVATION
TAG
SECTION TAG
ELEVATION TAG
PLAN DETAIL TAG
DOOR NUMBER
WINDOW NUMBER
CEILING HEIGHT
REFERENCE NOTE TAG
REVISION NUMBER
ELEVATION MARKER
WALL TAG
FLOOR ELEVATION
(DEMO, GENERAL NOTES, ETC.)
COLUMN TAG
EXISTING DOOR
NEW DOOR
WISSAHICKON FIRE COMPANY
245 Race Street Ambler, PA 19002 CONTACT: Al Comly
TEL: 215.205.9670
CONTACT: Michael Conte
TEL: 267.718.0870
XX
XX
A21 A21
XX
CH XX'-XX"
112a
+0'-0" x Axx x Axx
X
AXXX
DESIGNATION SHOWN AS 30x68 REFERS TO 3'-0" x 6'-8" DOOR. (SIZES MAY VARY)
CJ CEILING JOIST
COJ CONTROL JOINT
FJ FLOOR JOIST
CS1 COVER SHEET
ARCHITECTURAL:
A1 DEMOLITION PLANS
A2 DEMOLITION ELEVATIONS
A3 DEMOLITION ELEVATIONS
A4 DEMOLITION SECTIONS
A10 BUILDING PLANS
A11 PROPOSED ELEVATIONS
A12 PROPOSED ELEVATIONS
A13 PROPOSED SECTIONS
A40 WINDOW SCHEDULE
A41 WINDOW DETAILS - STOREFRONT
A42 WINDOW DETAILS - CURTAINWALL
Civil Engineer:
CHARLES E. SHOEMAKER, INC.
110 Keystone Drive Montgomery, PA 18936 CONTACT: Chad Brensinger, P.E.
TEL: 215.887.2165
Architect:
PHILLIPS | ASSOCIATES ARCHITECTS
87 East Butler Avenue Ambler, PA 19002 CONTACT: John Smith
TEL: 215.646.7878
WWW.PA-ARCH.COM
Stuctural Engineer:
GTA, INC. CONSULTING ENGINEERS
P.O. Box 10 Pipersville, PA 18947 CONTACT: Gary Talbot, P.E.
TEL: 215.766.3982
General Notes:
1. PRIOR TO ANY DIGGING, CALL THE PENNSYLVANIA PA 1 CALL SYSTEM AT 811
2. THE ARCHITECT IS NOT RESPONSIBLE FOR THE CONTRACTOR(S) MEANS AND METHODS OF
CONSTRUCTION.
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD. DISCREPANCIES BETWEEN ACTUAL CONDITIONS & DRAWINGS &/OR SPECIFICATIONS SHALL BE REPORTED TO THE ARCHITECT IN WRITING FOR CLARIFICATION. WORK SHALL NOT PROCEED UNTIL SUCH CLARIFICATION HAS BEEN RECEIVED.
4. WRITTEN DIMENSIONS ON THE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS INDICATED
ON THESE DRAWINGS.
5. SHOULD LOCAL CODES AND/OR ORDINANCES DIFFER FROM THESE PLANS, A DETERMINATION SHALL BE MADE BY THE GENERAL CONTRACTOR AND/OR LOCAL BUILDING OFFICIAL AS TO WHICH IS THE MOST STRINGENT. THE MOST STRINGENT REQUIREMENTS SHALL RULE. SHOULD A CHANGE IN THESE PLANS BE NECESSARY OR DESIRED WHICH WILL ALTER THE DESIGN OR STRUCTURAL INTEGRITY OF THE STRUCTURE(S), CONSULT WITH A QUALIFIED STRUCTURAL ENGINEER OR ARCHITECT TO VERIFY THAT SUCH A CHANGE WILL NOT BE DETRIMENTAL TO THE STRUCTURAL INTEGRITY OF THE STRUCTURE(S)
PRIOR TO IMPLEMENTING THE CHANGE.
6. THE CONTRACTOR IS RESPONSIBLE FOR THE SAFETY OF THE JOB SITE AND STRUCTURE INCLUDING THE DESIGN, ERECTION AND MAINTENANCE OF ALL SHORING, BRACING AND SAFETY BARRIERS.
7. SHOULD UNFORESEEN CONDITIONS OR OTHER CAUSES NECESSITATE CONSTRUCTION DETAILS NOT IN ACCORDANCE WITH THESE PLANS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND SUBMIT
DETAILS SHOWING THE PROPOSED METHODS TO ACCOMPLISH THE REQUIRED RESULTS.
8. ALL MATERIALS SHALL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS.
9. CONTRACTOR(S) SHALL BE FULLY RESPONSIBLE FOR ALL MATERIALS DELIVERED TO THE SITE AND
WILL ASSUME OWNERSHIP OF SAME UNTIL THEY HAVE BEEN INSTALLED PROPERLY. FOR ITEMS
SUPPLIED BY THE OWNER, OWNER IS RESPONSIBLE TAKING DELIVERY AND FOR VERIFYING CONDITION
PRIOR TO HANDOFF TO CONTRACTOR.
10. FOR THE DURATION OF THE CONSTRUCTION PERIOD, THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ALL DAMAGES CAUSED BY HIS WORKERS OR SUBCONTRACTORS' WORKERS. THE
CONTRACTOR SHALL REPAIR AND/OR REPLACE ALL BROKEN PARTS, INCLUDING GLASS, AT NO
ADDITIONAL COST TO THE OWNER AND BACK-CHARGE THIS TO THE RESPONSIBLE PARTY OR PARTIES.
ALL OPENINGS DUE TO CONSTRUCTION IN EXTERIOR WALLS AND ROOFS OF THE EXISTING STRUCTURE SHALL BE CAREFULLY PROTECTED WITH TEMPORARY CLOSURES TO PREVENT THE ENTRANCE OF ANY WATER, SNOW, OR ICE INTO INTERIOR SPACES. ANY DAMAGE DUE TO WATER, SNOW, OR ICE SHALL BE
FULLY REPAIRED BY THE CONTRACTOR AT NO COST WHATSOEVER TO THE OWNER.
11. WORKMANSHIP SHALL CONFORM TO THE BEST TRADE PRACTICES. FINISHED SURFACES SHALL BE
PLUMB AND LEVEL, STRAIGHT AND FREE OF IMPERFECTIONS AND SET FIRMLY TO ACCURATE
MEASUREMENTS. FINISHED PRODUCT SHALL BE TOTALLY CLEAN AND FREE OF COVERING MATERIALS, LOOSE OR FOREIGN MATERIALS, ETC.
12. THE CONTRACTOR IS EXPECTED TO KEEP THE ENTIRE PREMISES FREE OF DEBRIS, DISCARDED
MATERIAL, ETC. UPON COMPLETION OF CONSTRUCTION, THE CONTRACTOR IS TO CLEAN THE
EXTERIOR OF THE STRUCTURE AND THE SITE REMOVING ALL STAINS, DEBRIS, ETC. RESULTING FROM CONSTRUCTION. THE CONTRACTOR SHALL ALSO CLEAN ALL INTERIOR AREAS OF THE STRUCTURE IN
THE AREAS OF NEW WORK. ALL GLASS, INSIDE AND OUT, SHALL BE COMPLETELY CLEANED
13. ALL PERMITS SHALL BE ACQUIRED BY THE CONTRACTOR PRIOR TO COMMENCEMENT OF DEMOLITION
AND CONSTRUCTION. CONTRACTOR IS TO CONFIRM REGISTRATION REQUIREMENTS WITH THE
MUNICIPALITY PRIOR TO CONSTRUCTION
14. CONTRACTOR TO BE RESPONSIBLE FOR SCHEDULING ALL INSPECTIONS - COORDINATE WITH THE
MUNICIPALITY FOR APPROVED INSPECTORS LISTS
15. CONTRACTOR SHALL INSPECT THE PREMISES AND VIEW THE EXISTING CONDITIONS TO VERIFY ALL CONDITIONS, SIZES, AND QUANTITIES. EXISTING CONDITIONS WHICH MIGHT PRECLUDE OR INTERFERE WITH THE PROPOSED WORK AS DRAWN OR SPECIFIED SHALL BE BROUGHT THE THE ATTENTION OF
THE OWNER FOR RESOLVING.
16. ALL WORK TO BE PLUMB, LEVEL AND SQUARE. COORDINATE AND ALIGN STRUCTURE, FLOOR
ELEVATIONS WITH EXISTING CONDITIONS WHERE REQUIRED
17. CONTRACTOR TO HAVE BUILDING LOCATION STAKED OUT COMPLIANT TO ALL ZONING REGULATIONS.
18. CONCEALED SURFACES OF DISSIMILAR MATERIALS TO HAVE APPLIED COATING OR BARRIER TO
PREVENT CORROSION EFFECT OF GALVANIC ACTION.
19. P+A DOES NOT GUARANTEE THE PERFORMANCE OF AND HAS NO RESPONSIBILITY FOR THE ACTS OR OMISSIONS OF ANY CONTRACTOR, SUBCONTRACTOR, SUPPLIER OR ANY OTHER ENTITY FURNISHING
MATERIALS OR PERFORMING ANY WORK ON THIS PROJECT
20. STANDARD COUNTERTOP HEIGHTS TO BE 34" (KITCHENETTE CABINETS, GENERAL WORK BENCHES, ETC.) AND 30" (BATHROOM VANITIES AND DESK TOPS) MEASURED FROM THE FINISHED FLOOR. VERIFY THESE STANDARD HEIGHTS WITH THE OWNER AND CABINET DRAWINGS, (IF APPLICABLE), BEFORE ORDERING CABINETS. GC TO COORDINATE WITH REQUIRED ACCESSIBILITY CODES, OWNER, AND CODE
OFFICIAL ON ALL REQUIRED APPLIANCES & EQUIPMENT TO ASSURE PROPER CLEARANCES.
21. IF DOOR SIZES ARE INDICATED ON PLANS, THESE INDICATE SIZE OF DOOR ONLY, NOT FRAME SIZE. IF
DOORS ARE NUMBERED, REFER TO DOOR SCHEDULE. CONTRACTOR TO VERIFY ALL DOOR SIZES,
ORIENTATION, OPERATION & HARDWARE (INCLUDING LOCKS) WITH OWNER PRIOR TO ORDERING.
22. STAIR REQUIREMENTS: (I.B.C. 2018 SECTION 1011)
MAX. RISER = 7" TREAD = 11" MIN. WIDTH: (1011.2)
- OCC. <50 &/OR SPRINKLERED = 36"
- OTHERWISE = 44"
MAX. RISER VARIATION = 3/8" MIN. HEADROOM CLEARANCE = 6'-8"
MAX. VERTICAL RISE = 12'-0"
MAX. RISER OPENING = SOLID (SEE EXCEPTIONS 1011.5.5.3)
23. HANDRAIL REQUIREMENTS: (I.B.C. 2018 SECTION 1014)
MAX. HEIGHT = 34 IN. MAX. HEIGHT = 38 IN.
MIN. CLEARANCE FROM WALL = 1 1/2" MIN. EDGE RADIUS = 0.01"
MIN. CIRCULAR GRIP SIZE = 1 1/4 IN. MAX. CIRCULAR GRIP SIZE = 2 IN. (SEE 1014.3 FOR
NON-CIRCULAR)
24. GUARDRAIL REQUIREMENTS: (I.B.C. 2018 SECTION 1015)
GUARDS ARE REQUIRED FOR OPEN-SIDED WALKING SURFACES, INCLUDING MEZZANINES,
EQUIPMENT PLATFORMS, AISLES, STAIRS, RAMPS, AND LANDINGS THAT ARE LOCATED
MORE THAN 30 INCHES MEASURED VERTICALLY ABOVE ADJACENT FLOOR OR GRADE AT ANY
POINT WITHIN 36" HORIZONTALLY TO THE EDGE OF THE OPEN SIDE.
HEIGHT = 42 IN. MAX. OPENING <4 IN. Ø(<4 3/8 IN. Ø FROM A HEIGHT OF 36" TO 42")
25. OBSERVATIONS PERFORMED BY P+A (WHEN ENGAGED FOR CONSTRUCTION OBSERVATIONS) SHALL NOT BE CONSIDERED A SUBSTITUTE FOR THE QUALITY CONTROL PROGRAMS AND PROCEDURES OF ANY CONTRACTOR, SUBCONTRACTOR, SUPPLIER OR ANY OTHER ENTITY FURNISHING MATERIALS OR
PERFORMING ANY WORK ON THIS PROJECT.
26. THE OWNER HAS NOT RETAINED PHILLIPS AND ASSOCIATES ARCHITECTS, LLC (P+A) TO PERFORM CONSTRUCTION OBSERVATION SERVICES. P+A DOES NOT GUARANTEE THE PERFORMANCE OF, AND SHALL HAVE NO RESPONSIBILITY FOR FURNISHING MATERIALS OR PERFORMING ANY WORK ON THE PROJECT. IF THE CLIENT DESIRES MORE EXTENSIVE PROJECT OBSERVATION THE CLIENT SHALL
REQUEST IN WRITING SUCH SERVICES BE PROVIDED BY P+A AS A SEPARATE AND ADDITIONAL
SERVICES.
Project Image:
Outline Specifications:
GENERAL
THIS IS A GENERAL UNDERSTANDING OF BUILDING MATERIALS AND/OR PROCEDURES TO BE USED IN THIS PROJECT AND ARE NOT FULL SPECIFICATIONS.
ALTERNATE METHODS AND/OR SUBSTITUTE MATERIALS SHOULD ONLY BE USED WITH THE FULL UNDERSTANDING AND APPROVAL OF THE PROJECT OWNER AND
ARCHITECT. DISREGARD REFERENCES TO ITEMS WHICH DO NOT OCCUR IN THIS PROJECT.
ALL WORK WAS DESIGNED TO AND SHALL CONFORM TO THE “2018 INTERNATIONAL BUILDING CODE.”
STRUCTURAL SECTIONS AND DETAILS SHALL BE CONSIDERED TYPICAL FOR SIMILAR CONDITIONS THAT DO NOT HAVE A SPECIFIC SECTION INDICATED, AND
SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER.
CONSTRUCTION SEQUENCES SHALL ALLOW FOR MATERIAL MOVEMENT DUE TO TEMPERATURE EFFECTS DURING THE CONSTRUCTION PERIOD PRIOR TO THE BUILDING BEING ENCLOSED AND THE ENVIRONMENT CONTROLLED. ANY FROST HEAVING OF FOUNDATIONS OR SLAB ON GRADE, CRACKING, ADJUSTMENTS, ETC. DUE TO THERMAL EFFECTS SHALL BE CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.
METALS
METAL CONNECTORS & FASTENERS SUCH AS NAILS, BOLTS, JOIST HANGERS, ETC. SHALL BE HOT DIPPED HEAVY GALVANIZED. ALL METAL EXPOSED TO WEATHER OR IN CONCEALED SPACES SHALL BE NON-FERROUS OR HEAVY GALVANIZED U.N.O. ALL METAL CONNECTORS IN CONTACT WITH PRESERVATIVE TREATED WOOD SHALL BE HOT DIPPED GALVANIZED WITH MINIMUM G185 COATING AND SHALL MEET OR EXCEED THE CORROSION PROTECTION OF SIMPSON
STRONG-TIE CO. ZMAX COATING, OR SHALL BE TYPE 304 OR 316 STAINLESS STEEL.
MATERIALS:
A) STRUCTURAL STEEL BEAMS SHALL CONFORM TO ASTM A992, GRADE 50. Fy = 50 KSI B) RECTANGULAR AND SQUARE TUBES SHALL BE ASTM A500, GRADE B, Fy = 46 KSI C) PLATES, ANGLES, AND CHANNELS SHALL CONFORM TO ASTM A36, Fy = 36 KSI D) ROUND PIPE COLUMNS SHALL CONFORM TO ASTM A500, GRADE B, Fy = 42 KSI E) STANDARD PIPES, STD, ASTM A53, GRACE B, Fy = 35 KSI
F) BOLTS AND WASHERS SHALL CONFORM TO ASTM A325
G) ANCHOR BOLTS SHALL BE GALVANIZED STEEL AND CONFORM TO ASTM A36, ASTM A307 OR ASTM F1554, GRADE 55
PROVIDE A MINIMUM OF (2)ROWS OF 3/4" DIA. BOLTS @2'-0" O.C. STAGGERED MAXIMUM TO CONNECT ALL PACKED OUT WOOD BLOCKING TO STEEL WEBS.
PROVIDE A MINIMUM OF (2)ROWS OF 5/8" DIA. BOLTS @2'-8" O.C. STAGGERED MAXIMUM TO CONNECT WOOD PLATE TO TOP OF STEEL FLANGE.
SHOP PAINTING: ALL STEEL WORK SHALL BE CLEANED & SHOP COATED W/ ONE COAT OF RUST INHIBITIVE PAINT. ALL FIELD WELDS SHALL BE GROUND SMOOTH & PRIMED W/ A RUST INHIBITIVE COAT OR HOT DIP GALVANIZED IN EXTERIOR WALLS ACCORDING TO ASTM A123.
WELDING: SHALL BE (E70XX) IN ACCORDANCE WITH THE AMERICAN WELDING SOCIETY (AWS) PUBLICATION D1.1 STRUCTURAL WELDING CODE USING THE METHODS & ELECTRODES AS RECOMMENDED BY THE MANUFACTURER OF THE BASE METAL ALLOYS BEING USED
STRUCTURAL STEEL: VERIFY ALL FIELD DIMENSIONS PRIOR TO ORDER. FABRICATE AND ERECT STRUCTURAL STEEL IN ACCORDANCE WITH AISC MANUAL OF STEEL CONSTRUCTION LATEST EDITION. PROVIDE DOUBLE NUTS FOR ALL COLUMN ANCHOR BOLTS TO ALLOW FOR ADJUSTMENT AND LEVELING. INSTALL 1" MIN NON-SHRINK GROUT UNDER BASE PLATE AFTER ERECTION. ALL ANCHOR BOLT LENGTHS ARE EMBEDMENT LENGTHS. ALL COLUMN TO BEAM AND BEAM TO BEAM CONNECTIONS TO BE MADE WITH ASTM A-325 HIGH STRENGTH BOLTS. OTHER CONNECTIONS MAY BE MADE WITH STANDARD MACHINE BOLTS. ALL BEAM
POCKETS TO HAVE 1/2" AIRSPACE ALL SIDES AND USE METAL LEVELING PLATES
STRUCTURAL STEEL CONNECTIONS: CONNECTIONS NOT SHOWN ON DRAWINGS SHALL BE DESIGNED BY THE STEEL FABRICATOR. ALL CONNECTIONS SHALL BE "FRAMED BEAM CONNECTIONS" DESIGNED IN ACCORDANCE WITH AISC, ASD, "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS."
SHOP AND FIELD CONNECTIONS FOR STRUCTURAL STEEL SHALL BE WELDED (E70XX) OR BOLTED (ASTM A325 OR ASTM 490). CONNECTION BETWEEN WIDE FLANGE BEAMS SHALL BE MADE WITH DOUBLE CLIP ANGLES, L3-1/2" x L3" X 5/16" MINIMUM.
COLD FORMED (LOAD BEARING) METAL FRAMING: ALL COLD FORMED METAL FRAMING (CFMF) STRUCTURAL MEMBERS SHALL BE DESIGNED, MANUFACTURED AND INSTALLED IN ACCORDANCE WITH THE LATEST AMERICAN IRON AND STEEL INSTITUTE (AISC) SPECIFICATIONS. ALL MEMBERS SHALL BE FORMED FROM CORROSION RESISTANT STEEL, CORRESPONDING TO THE REQUIREMENTS OF ASTM A653, WITH A MINIMUM YIELD STRENGTH OF 33 KSI FOR 43 MILS AND SMALLER AND 50 KSI FOR 54 MILS AND LARGER FOR STUDS/JOISTS AND 33 KSI FOR RUNNERS, ZINC COATED MEETING ASTM A924. ALL MULTIPLE STUD POSTS SHALL BE WELDED, (OFF-SITE) TOGETHER AT 4'-0" MAX. O.C. OR SELF-DRILLING, SELF-TAPPING SCREWS AT 4'-0” MAX. O.C. MAKE CONNECTIONS WITH SELF-DRILLING, SELF-TAPPING SCREWS SO THAT THE CONNECTIONS MEET OR EXCEED DESIGN LOADS. PROVIDE TEMPORARY BRACING FOR ALL GAGE METAL
STUD WORK WHICH IS TO REMAIN IN PLACE UNTIL WORK IS PERMANENTLY STABILIZED.
ROUGH CARPENTRY
ALL EXTERIOR LUMBER TO BE PRESERVATIVE TREATED. PRESERVATIVE TREATED WOOD SHALL BE LIMITED TO ACQ-C WITH MAXIMUM RETENTION LEVELS IN THE WOOD OF 0.40 PCF. WOOD SHALL NOT CONTAIN AMMONIA. ALL FASTENERS SHALL BE STAINLESS STEEL.
CONCEALED SPACES WITHIN WALL PARTITIONS, FLOOR OR DUCT OPENINGS IN SUCH CONSTRUCTION SHALL BE FIRESTOPPED. CONCEALED VERTICAL SPACES IN WALLS AND PARTITIONS SHALL BE FIRESTOPPED AT EACH FLOOR LEVEL AND AT THE CEILING OF THE UPPERMOST STORY SO THAT SUCH SPACES WILL NOT BE CONTINUOUS FOR MORE THAN ONE STORY, OR COMMUNICATE WITH CONCEALED HORIZONTAL SPACES IN THE FLOOR OR ROOF CONSTRUCTION.
ALL MEMBERS SHALL BE CLOSELY FITTED, ACCURATELY SET TO REQUIRED LINES & LEVELS & RIGIDLY SECURED IN PLACE WITH PROPER BEARING AND CORRECT SIZE AND TYPE OF FASTENING. NAILING SHALL BE IN ACCORDANCE WITH THE PENNSYLVANIA STATE BUILDING CODE.
BLOCKING: SHALL BE PROVIDED AS NECESSARY FOR APPLICATION OF SHEATHING, WALLBOARD AND OTHER MATERIALS OF BUILDING ITEMS, INSTALLATION OF
WALL / CEILING MOUNTED FIXTURES AND EQUIPMENT.
PROVIDE CLEARANCES BETWEEN FRAMING AND OTHER CONSTRUCTION THAT MAY BE SUBJECT TO DIFFERENTIAL MOVEMENT, NOISE TRANSFER & FIRE HAZARD.
ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY IN ANY FORM SHALL BE PRESERVATIVE TREATED IN ACCORDANCE WITH AWPA STANDARD U1, AS
APPLICABLE. BRUSH COAT ALL CUT ENDS WITH SAME TREATMENT.
FIRESTOPPING SHALL BE CONSTRUCTED TO CLOSE ALL CONCEALED DRAFT OPENINGS AND TO FORM EFFECTUAL FIRE BARRIERS AGAINST THE SPREAD OF FIRES BETWEEN STORIES OF EACH AND EVERY BUILDING AND IN ALL OPEN STRUCTURAL SPACES THEREIN.
DOORS & WINDOWS
WINDOWS AND EXTERIOR DOOR ASSEMBLIES SHALL RECEIVE BOTH HEAD FLASHING & SILL FLASHING AND/OR SILL PANS. CONTRACTOR SHALL USE FLASHING MATERIALS THAT ARE COMPATIBLE WITH ADJACENT BUILDING MATERIALS. NOTE: APPLYING BUYTLE TAPE(S) AROUND THE PERIMETER OF DOOR AND WINDOW ASSEMBLIES DOES NOT QUALIFY AS INSTALLING FLASHING(S). CONTRACTOR SHALL INSURE THAT WHEN INSTALLING FLASHING THAT ADJACENT MATERIALS ARE PROPERLY LAPPED WITH INSTALLED FLASHING MEMBERS. DOORS SHALL BE FURNISHED PRE-HUNG IN A FRAME OF WIDTH TO SUIT WALL THICKNESS.
EXTERIOR DOORS: PRE-HUNG IN EXTERIOR FRAME, REFER TO PLANS OR SCHEDULE FOR SIZES AND TYPES.
WINDOWS: INSULATED GLAZING & COLOR BY OWNER. REFER TO PLANS OR SCHEDULE FOR SIZES &/ OR TYPES & / OR MODEL NUMBERS. (MANUFACTURERS MUST BE APPROVED BY OWNER & ARCHITECT, ROUGH OPENINGS OF WINDOWS MUST BE VERIFIED BY CONTRACTOR PRIOR TO PURCHASING)
GLAZING: ALL WINDOWS AND DOORS W/ GLASS SHALL HAVE INSULATED GLASS WITH LOW-E, UNO. ALL DOORS AND WINDOWS MUST COMPLY TO IECC 2018 [TABLE C402.4 AND CAD2.4] FOR INSULATION VALUES. ALL GLAZING BELOW 18" AFF AND ALL GLAZING WITHIN THE ARC OF THE DOOR SWING IS TO BE TEMPERED.
ALL DOORS WITH GLAZING TO BE TEMPERED GLASS.
U FACTOR REQUIREMENTS (FOR CLIMATE ZONE 4):
- FIXED FENESTRATION: 0.38
- OPERABLE FENESTRATION: 0.45
- ENTRANCE DOORS: 0.77
FINISH CARPENTRY
BASEBOARD & CASING: S 4S CLEAR WHITE PINE CONFIRM SIZE, SHAPE & FINISH WITH OWNER.
TRIM: S 4S KILN DRIED, SELECT GRADE WOOD. CONFIRM SIZE, SHAPE & FINISH WITH OWNER
THERMAL AND MOISTURE PROTECTION
INSULATION: (IECC 2018 SECTION C402) SEE SECTIONS FOR R-VALUES. VERIFY VALUES WITH LOCAL CODE OFFICIALS FOAMED-IN-PLACE INSULATION: PROVIDE AIRTIGHT CLOSED-CELL SPRAY FOAM INSULATION WHERE INDICATED. FOLLOW ALL MANUF'S RECOMMENDATION FOR APPLICATION. CERTAIN APPLICATIONS REQUIRE THERMAL / IGNITION BARRIER. FOAM INSULATION REQUIRES A THERMAL / IGNITION BARRIER WHEN EXPOSED TO THE 'INTERIOR OF THE BUILDING'. PROVIDE APPROPRIATE BARRIER OR CONFIRM WITH SPECIFIC PRODUCT ON INCLUSION OF AN INTEGRATED THERMAL /
IGNITION BARRIER.
SEALANTS:
EXTERIOR VERTICAL: COLOR TO MATCH ADJACENT SURFACES. ONE-PART NON-ACID CURING SILICONE SEALANT: FOR USE BETWEEN CONCRETE, MASONRY, METAL, WOOD & IN EXTERIOR OVERHEAD JOINTS (BASIS OF DESIGN: TREMCO SPECTREM 1) EXTERIOR HORIZONTAL: COLOR TO MATCH ADJACENT SURFACES. COORD. ONE-PART POURABLE URETHANE SEALANT: FOR USE BETWEEN CONCRETE, MASONRY & METAL (BASIS OF DESIGN: TREMCO VULKEM 45 SSL)
INTERIOR: ACRYLIC LATEX SEALANT: FOR USE BETWEEN JOINTS OF FIELD PAINTED METAL, GYPSUM, PLASTER, CONCRETE & MASONRY
[BASIS OF DESIGN: TREMCO TREMFLEX 834]
FIRE STOPPING: FOAMED IN PLACE SEALANT: FOR USE IN FIRE-RATED ASSEMBLIES INVOLVING MULTIPLE PIPE & CONDUIT PENETRATIONS
[BASIS OF DESIGN: DAP FIREBLOCK FOAM POLYURETHANE]
ONE-PART FIRE STOP SEALANT: FOR USE IN FIRE-RATED ASSEMBLIES INVOLVING SINGLE PIPE & CONDUIT PENETRATIONS & NARROW JOINTS
[BASIS OF DESIGN: TREMCO TREMSTOP FYRE-SIL]
WEATHERSTRIPPING: ALL EXTERIOR DOORS & MECHANICAL ROOM DOORS SHALL RECEIVE WEATHER STRIPPING
FINISHES
VERIFY ALL COLORS & FINISHES OF ALL FINISH ITEMS: FLOOR COVERINGS, PAINT, FIXTURES, PLATES & SIDING W/ OWNER GYPSUM WALLBOARD (GWB): UNITED STATES GYPSUM (USG) OR APPROVED EQUAL. 1/2" GYPSUM WALLBOARD AT ALL INTERIOR SURFACES UNLESS NOTED OTHERWISE / USE MOLD RESISTANT TYPE AT SHOWERS, TUBS, SINKS, AND ANY OTHER WET LOCATIONS. TAPE ALL JOINTS AND FINISH SMOOTH (LEVEL 4 FINISH).
NOTE: WHERE TILE IS TO BE INSTALLED AT TUBS AND SHOWERS, INSTALL FIBERGLASS MAT WATER RESISTANT GYPSUM BACKING PANEL (GEORGIA
PACIFIC-DENSGUARD TILE BACKER OR EQUAL)
PAINT: SURFACES TO BE PAINTED OR STAINED SHOULD BE PROPERLY CLEANED AND PREPARED TO RECEIVE FINISH. ALL EXTERIOR PAINT AND STAINS SHOULD BE ALLOWED 48 HOURS TO DRY BETWEEN COATS; INTERIOR FINISHED SHOULD BE ALLOWED 24 HOURS BETWEEN COATS TO DRY (BASIS OF DESIGN:
FINNERAN & HALEY)
EXTERIOR: WOOD: (1) COAT ACRYLIC PRIMER, PORTER OR APPROVED EQUAL PLUS (2) COATS ACRYLIC LATEX SEMI-GLOSS
METAL: (1) COAT CEMENT OIL PRIMER (RUST INHIBITIVE) PLUS (2) COATS ALKYD ENAMEL, EGGSHELL
MASONRY: (1) COAT ACRYLIC BONDING PRIMER PLUS (2) COATS ACRYLIC LATEX FLAT SHEEN
INTERIOR: GWB: (1) COAT ACRYLIC PRIMER PLUS (2) COATS FLAT LATEX WALL PAINT
METAL: (1) COAT OIL BASED PRIMER OR WHITE LACQUER UNDERCOATER PLUS (2) COATS ENAMEL SEMI-GLOSS
WOOD: (1) COAT ACRYLIC PRIMER PLUS (2) COATS ALKYD ENAMEL, EGGSHELL
MENS
BATHROOM
WOMENS
BATHROOM
CL
KITCHENLAUNDRY
RADIO
ROOM
HALL
HOSE
TOWER
CHIEF'S
OFFICE
MEETING
ROOM
COMPRESSOR
ROOM
APPARATUS
BAY
CL
STORAGE
D N
DN
U P
D N
D N
D N
D N
D N
WINDOW
ABV
A3
A30
A3
A2
A2
A4
A4
A4
COLUMN TO
REMAIN
COLUMN TO
REMAIN
A3
03 02
03 02
03 03 03
WINDOW
ABV
KITCHENETTE
CLUB
ROOM
STORAGE STORAGESTORAGE
U P
UP
STORAGE
U P
A3
A2
A2
A4
A4
A4
COLUMN TO
REMAIN
A2
HOSE
TOWER
A2
HOSE
TOWER
A3
A2
A3
A2
HOSE
TOWER
DEMOLITION GENERAL NOTES
DEMOLITION LEGEND
ITEMS TO BE DEMOLISHED
DEMOLITION KEY NOTES
PROJECT
NORTH
EXISTING TO REMAIN
1. DO NOT SCALE DRAWINGS.
2. ENSURE AREA OF DEMOLITION IS ENTIRELY ON THE SUBJECT
PROPERTY. MAINTAIN ALLEYS & EASEMENTS SHARED BY
NEIGHBORING PROPERTIES.
3. PROTECT ADJACENT PROPERTIES FROM DAMAGE & DEMOLITION
DEBRIS; PROTECT PEDESTRIANS, VEHICLES, AND THE PUBLIC
RIGHT OF WAY FROM DAMAGE & DEMOLITION DEBRIS.
4. ENSURE ALL GAS, WATER, ELECTRIC AND ALL UTILITIES
SUPPLYING THE SITE HAVE BEEN PROPERLY DISCONNECTED OR
SHUT OFF PRIOR TO COMMENCEMENT DEMOLITION.
5. CUTTING AND REMOVAL INDICATED ON THE DRAWINGS ARE
GENERAL INDICATIONS ONLY AND MAY NOT SHOW FULL EXTENT
OF THE WORK TO BE REMOVED. FIELD VERIFY THE COMPLETE
EXTENT OF DEMOLITION WORK INVOLVED.
6. BEFORE BEGINNING ANY CUTTING OR DEMOLITION WORK,
CONTRACTOR SHALL CAREFULLY SURVEY CONDITIONS AND
DETERMINE THE EXTENT OF THE WORK TO BE DONE.
7. COORDINATE WITH ARCHITECT & STRUCTURAL ENGINEER PRIOR
TO REMOVING ANY EXISTING STRUCTURAL MEMBERS.
8. PROVIDE AND MAINTAIN BRACING AND SHORING TO PROTECT
THE STRUCTURAL INTEGRITY OF THE EXISTING STRUCTURE TO
REMAIN.
9. PRIOR TO DEMOLITION, COORDINATE WITH OWNER ON ALL ITEMS
TO BE REMOVED AND STORED FOR LATER USE.
10.REMOVALS SHALL BE PERFORMED WITHOUT DAMAGE TO
ADJACENT RETAINED WORK, HOWEVER WHERE SUCH WORK IS
DAMAGED, THE CONTRACTOR SHALL PATCH, REPAIR OR
OTHERWISE RESTORE DAMAGED ITEMS TO THEIR ORIGINAL
CONDITION, TO THE SATISFACTION OF THE OWNER, AT NO
ADDITIONAL COST TO THE OWNER.
11.REMOVE DOORS, WINDOWS, AND EQUIPMENT AS INDICATED ON
FLOOR PLANS. REMOVE ALL DEBRIS FROM BUILDING AND LEAVE
CLEAN.
12.WIRING, SWITCHES AND OUTLETS SHALL BE REMOVED AS
NECESSARY TO COMPLETE WORK INDICATED. WHERE WIRING IS
TO BE REMOVED, IT SHALL BE REMOVED BACK TO THE THE
NEAREST OUTLET OR JUNCTION BOX TO REMAIN IN SERVICE.
13.WHERE EXISTING ELECTRICAL WORK IS AFFECTED BY
DEMOLITION OR NEW CONSTRUCTION, RELOCATE AS
REQUIRED. COORDINATE WITH NEW ELECTRICAL WORK.
14.WHERE MECHANICAL AND ELECTRICAL EQUIPMENT HAS BEEN
REMOVED, REMOVE EXISTING HANGERS FOR EACH EQUIPMENT.
15. VERIFY WITH OWNER ON EXTENT OF FLOOR FINISH REMOVAL
AND/OR REFINISHING.
16.REMOVE CEILING FINISHES AS REQUIRED IN AREAS OF WORK.
PATCH AS REQUIRED UPON COMPLETION.
+0'-0" INDICATES HEIGHT OF
EXISTING SURFACE
EXISTING RADIATOR, COVER & ALL ASSOCIATED
MOUNTING HARDWARE & PLUMBING TO BE REMOVED.
USE CAUTION TO PRESERVE ADJACENT FINISHES &
TRIM.
REMOVE EXISTING WINDOW SHADES AND STORE FOR
RE-INSTALLTION ON NEW WORK.
REMOVE EXISTING WINDOW, FRAME, SILL AND DOOR
(WHERE PRESENT). INCLUDING, BUT NOT LIMITED TO,
SHIMS, SEALANT AND BLOCKING BACK TO ROUGH
OPENING FOR NEW WINDOW SYSTEM.
N
REMOVE CANOPY STRUCTURE INCLUDING INTERNAL
SUPPORT BEAMS.
REMOVE WINDOW ABOVE EXIT DOOR. CONSULT WITH
ARCHITECT IF DEMO NEEDS TO INCLUDE REMOVAL OF
GABLE ROOF OVER DOOR.
REMOVE EXTERIOR LIGHT FIXTURE AND VIDEO CAMERA
ALL MOUNTING HARDWARE & SAVE FOR
RE-INSTALLATION ON NEW WORK.
D
EM
O
LI
TI
O
N
FL
O O
R P
LA
N
S
A1
SCALE:1 GROUND FLOOR DEMO PLAN
1/8" = 1'-0"
E as t
Bu tle r A ve nu e
A m bl er
PA
p
:2
.6
.7 w w .p a-ar ch .c om ph ill ip s a ss oc ia te s a r c h i t e c t s i n t e r i o r s p l a n n e r s
N
O V
B
ID
S
ET
PA Registration: RA015197X
W
IS
SA
H
IC
K
O N
F
IR
E C
O M
PA
N
Y W
IN
D
O W
R
EP
LA
C
EM
EN
T
SCALE:2 FIRST FLOOR DEMO PLAN
1/8" = 1'-0"
SCALE:3 TOWER DEMO PLANS
1/8" = 1'-0"
LOW
MID
TOP
AutoCAD SHX Text
GG
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REV.#
AutoCAD SHX Text
PROJECT NO:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text REV. Date
AutoCAD SHX Text REV. Notes
AutoCAD SHX Text Plans, specifications, reports, documents, or other information recorded on or transmitted as electronic media are subject to undetectable alteration, either intentional or unintentional, due to, among other causes, transmission, conversion, media degradation, software error or human alteration. all such documents are provided for informational purposes only and not as an end product nor as a record document. any reliance thereon is deemed to be unreasonable and unenforceable. All drawings, specifications, and related documents are copyright of the architect and must be returned upon request. reproduction of drawings, specifications, and related documents in part or whole is forbidden without the architects written permission. Do not scale drawings
AutoCAD SHX Text
245 RACE STREET
AutoCAD SHX Text
AMBLER, PA 19002
AutoCAD SHX Text 025 037.2
AutoCAD SHX Text 26.11.25
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text
APARATUS BAY
+9'-4"
(EX)(EX) (EX) (EX)
GROUND FLOOR
+0'-0"
FIRST FLOOR
+9'-11"
030303
GROUND FLOOR
+0'-0"
FIRST FLOOR
+9'-11"
(EX)
(EX)(EX)
APARATUS BAY
+9'-4"
03 03 03
DEMOLITION GENERAL NOTES
DEMOLITION LEGEND
ITEMS TO BE DEMOLISHED
DEMOLITION KEY NOTES
1. DO NOT SCALE DRAWINGS.
2. ENSURE AREA OF DEMOLITION IS ENTIRELY ON THE SUBJECT
PROPERTY. MAINTAIN ALLEYS & EASEMENTS SHARED BY
NEIGHBORING PROPERTIES.
3. PROTECT ADJACENT PROPERTIES FROM DAMAGE & DEMOLITION
DEBRIS; PROTECT PEDESTRIANS, VEHICLES, AND THE PUBLIC
RIGHT OF WAY FROM DAMAGE & DEMOLITION DEBRIS.
4. ENSURE ALL GAS, WATER, ELECTRIC AND ALL UTILITIES
SUPPLYING THE SITE HAVE BEEN PROPERLY DISCONNECTED OR
SHUT OFF PRIOR TO COMMENCEMENT DEMOLITION.
5. CUTTING AND REMOVAL INDICATED ON THE DRAWINGS ARE
GENERAL INDICATIONS ONLY AND MAY NOT SHOW FULL EXTENT
OF THE WORK TO BE REMOVED. FIELD VERIFY THE COMPLETE
EXTENT OF DEMOLITION WORK INVOLVED.
6. BEFORE BEGINNING ANY CUTTING OR DEMOLITION WORK,
CONTRACTOR SHALL CAREFULLY SURVEY CONDITIONS AND
DETERMINE THE EXTENT OF THE WORK TO BE DONE.
7. COORDINATE WITH ARCHITECT & STRUCTURAL ENGINEER PRIOR
TO REMOVING ANY EXISTING STRUCTURAL MEMBERS.
8. PROVIDE AND MAINTAIN BRACING AND SHORING TO PROTECT
THE STRUCTURAL INTEGRITY OF THE EXISTING STRUCTURE TO
REMAIN.
9. PRIOR TO DEMOLITION, COORDINATE WITH OWNER ON ALL ITEMS
TO BE REMOVED AND STORED FOR LATER USE.
10.REMOVALS SHALL BE PERFORMED WITHOUT DAMAGE TO
ADJACENT RETAINED WORK, HOWEVER WHERE SUCH WORK IS
DAMAGED, THE CONTRACTOR SHALL PATCH, REPAIR OR
OTHERWISE RESTORE DAMAGED ITEMS TO THEIR ORIGINAL
CONDITION, TO THE SATISFACTION OF THE OWNER, AT NO
ADDITIONAL COST TO THE OWNER.
11.REMOVE DOORS, WINDOWS, AND EQUIPMENT AS INDICATED ON
FLOOR PLANS. REMOVE ALL DEBRIS FROM BUILDING AND LEAVE
CLEAN.
12.WIRING, SWITCHES AND OUTLETS SHALL BE REMOVED AS
NECESSARY TO COMPLETE WORK INDICATED. WHERE WIRING IS
TO BE REMOVED, IT SHALL BE REMOVED BACK TO THE THE
NEAREST OUTLET OR JUNCTION BOX TO REMAIN IN SERVICE.
13.WHERE EXISTING ELECTRICAL WORK IS AFFECTED BY
DEMOLITION OR NEW CONSTRUCTION, RELOCATE AS
REQUIRED. COORDINATE WITH NEW ELECTRICAL WORK.
14.WHERE MECHANICAL AND ELECTRICAL EQUIPMENT HAS BEEN
REMOVED, REMOVE EXISTING HANGERS FOR EACH EQUIPMENT.
15. VERIFY WITH OWNER ON EXTENT OF FLOOR FINISH REMOVAL
AND/OR REFINISHING.
16.REMOVE CEILING FINISHES AS REQUIRED IN AREAS OF WORK.
PATCH AS REQUIRED UPON COMPLETION.
EXISTING RADIATOR, COVER & ALL ASSOCIATED
MOUNTING HARDWARE & PLUMBING TO BE REMOVED.
USE CAUTION TO PRESERVE ADJACENT FINISHES &
TRIM.
REMOVE EXISTING WINDOW SHADES AND STORE FOR
RE-INSTALLTION ON NEW WORK.
REMOVE EXISTING WINDOW, FRAME, SILL AND DOOR
(WHERE PRESENT). INCLUDING, BUT NOT LIMITED TO,
SHIMS, SEALANT AND BLOCKING BACK TO ROUGH
OPENING FOR NEW WINDOW SYSTEM.
REMOVE CANOPY STRUCTURE INCLUDING INTERNAL
SUPPORT BEAMS.
REMOVE WINDOW ABOVE EXIT DOOR. CONSULT WITH
ARCHITECT IF DEMO NEEDS TO INCLUDE REMOVAL OF
GABLE ROOF OVER DOOR.
REMOVE EXTERIOR LIGHT FIXTURE AND VIDEO CAMERA
ALL MOUNTING HARDWARE & SAVE FOR
RE-INSTALLATION ON NEW WORK.
D
EM
O
LI
TI
O
N E
LE
V
A
TI
O N
S
A2
E as t
Bu tle r A ve bl er
PA
.6
.7 w .p a-ar ch .c om ph ill ip s a ss oc ia te s a r c h i t e c t s i n t e r i o r s p l a n n e r s
N
O V
B
ID
S
ET
PA Registration: RA015197X
W
IS
SA
H
IC
K
O N
F
IR
E C
O M
PA
N
Y W
IN
D
O W
R
EP
LA
C
EM
EN
T
SCALE:1 SOUTH ELEVATION - DEMO
1/8" = 1'-0"
SCALE:2 NORTH ELEVATION - DEMO
1/8" = 1'-0"
AutoCAD SHX Text
GG
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REV.#
AutoCAD SHX Text
PROJECT NO:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text REV. Date
AutoCAD SHX Text REV. Notes
AutoCAD SHX Text Plans, specifications, reports, documents, or other information recorded on or transmitted as electronic media are subject to undetectable alteration, either intentional or unintentional, due to, among other causes, transmission, conversion, media degradation, software error or human alteration. all such documents are provided for informational purposes only and not as an end product nor as a record document. any reliance thereon is deemed to be unreasonable and unenforceable. All drawings, specifications, and related documents are copyright of the architect and must be returned upon request. reproduction of drawings, specifications, and related documents in part or whole is forbidden without the architects written permission. Do not scale drawings
AutoCAD SHX Text
245 RACE STREET
AutoCAD SHX Text
AMBLER, PA 19002
AutoCAD SHX Text 025 037.2
AutoCAD SHX Text 26.11.25
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
APARATUS BAY
+9'-4"
(EX)
05030303
GROUND FLOOR
+0'-0"
FIRST FLOOR
+9'-11"
A3
(EX)
03 03
APARATUS BAY
+9'-4"
DEMOLITION GENERAL NOTES
DEMOLITION LEGEND
ITEMS TO BE DEMOLISHED
DEMOLITION KEY NOTES
1. DO NOT SCALE DRAWINGS.
2. ENSURE AREA OF DEMOLITION IS ENTIRELY ON THE SUBJECT
PROPERTY. MAINTAIN ALLEYS & EASEMENTS SHARED BY
NEIGHBORING PROPERTIES.
3. PROTECT ADJACENT PROPERTIES FROM DAMAGE & DEMOLITION
DEBRIS; PROTECT PEDESTRIANS, VEHICLES, AND THE PUBLIC
RIGHT OF WAY FROM DAMAGE & DEMOLITION DEBRIS.
4. ENSURE ALL GAS, WATER, ELECTRIC AND ALL UTILITIES
SUPPLYING THE SITE HAVE BEEN PROPERLY DISCONNECTED OR
SHUT OFF PRIOR TO COMMENCEMENT DEMOLITION.
5. CUTTING AND REMOVAL INDICATED ON THE DRAWINGS ARE
GENERAL INDICATIONS ONLY AND MAY NOT SHOW FULL EXTENT
OF THE WORK TO BE REMOVED. FIELD VERIFY THE COMPLETE
EXTENT OF DEMOLITION WORK INVOLVED.
6. BEFORE BEGINNING ANY CUTTING OR DEMOLITION WORK,
CONTRACTOR SHALL CAREFULLY SURVEY CONDITIONS AND
DETERMINE THE EXTENT OF THE WORK TO BE DONE.
7. COORDINATE WITH ARCHITECT & STRUCTURAL ENGINEER PRIOR
TO REMOVING ANY EXISTING STRUCTURAL MEMBERS.
8. PROVIDE AND MAINTAIN BRACING AND SHORING TO PROTECT
THE STRUCTURAL INTEGRITY OF THE EXISTING STRUCTURE TO
REMAIN.
9. PRIOR TO DEMOLITION, COORDINATE WITH OWNER ON ALL ITEMS
TO BE REMOVED AND STORED FOR LATER USE.
10.REMOVALS SHALL BE PERFORMED WITHOUT DAMAGE TO
ADJACENT RETAINED WORK, HOWEVER WHERE SUCH WORK IS
DAMAGED, THE CONTRACTOR SHALL PATCH, REPAIR OR
OTHERWISE RESTORE DAMAGED ITEMS TO THEIR ORIGINAL
CONDITION, TO THE SATISFACTION OF THE OWNER, AT NO
ADDITIONAL COST TO THE OWNER.
11.REMOVE DOORS, WINDOWS, AND EQUIPMENT AS INDICATED ON
FLOOR PLANS. REMOVE ALL DEBRIS FROM BUILDING AND LEAVE
CLEAN.
12.WIRING, SWITCHES AND OUTLETS SHALL BE REMOVED AS
NECESSARY TO COMPLETE WORK INDICATED. WHERE WIRING IS
TO BE REMOVED, IT SHALL BE REMOVED BACK TO THE THE
NEAREST OUTLET OR JUNCTION BOX TO REMAIN IN SERVICE.
13.WHERE EXISTING ELECTRICAL WORK IS AFFECTED BY
DEMOLITION OR NEW CONSTRUCTION, RELOCATE AS
REQUIRED. COORDINATE WITH NEW ELECTRICAL WORK.
14.WHERE MECHANICAL AND ELECTRICAL EQUIPMENT HAS BEEN
REMOVED, REMOVE EXISTING HANGERS FOR EACH EQUIPMENT.
15. VERIFY WITH OWNER ON EXTENT OF FLOOR FINISH REMOVAL
AND/OR REFINISHING.
16.REMOVE CEILING FINISHES AS REQUIRED IN AREAS OF WORK.
PATCH AS REQUIRED UPON COMPLETION.
EXISTING RADIATOR, COVER & ALL ASSOCIATED
MOUNTING HARDWARE & PLUMBING TO BE REMOVED.
USE CAUTION TO PRESERVE ADJACENT FINISHES &
TRIM.
REMOVE EXISTING WINDOW SHADES AND STORE FOR
RE-INSTALLTION ON NEW WORK.
REMOVE EXISTING WINDOW, FRAME, SILL AND DOOR
(WHERE PRESENT). INCLUDING, BUT NOT LIMITED TO,
SHIMS, SEALANT AND BLOCKING BACK TO ROUGH
OPENING FOR NEW WINDOW SYSTEM.
REMOVE CANOPY STRUCTURE INCLUDING INTERNAL
SUPPORT BEAMS.
REMOVE WINDOW ABOVE EXIT DOOR. CONSULT WITH
ARCHITECT IF DEMO NEEDS TO INCLUDE REMOVAL OF
GABLE ROOF OVER DOOR.
REMOVE EXTERIOR LIGHT FIXTURE AND VIDEO CAMERA
ALL MOUNTING HARDWARE & SAVE FOR
RE-INSTALLATION ON NEW WORK.
D
EM
O
LI
TI
O
N E
LE
V
A
TI
O N
S
A3
E as t
Bu tle r A ve bl er
PA
.6
.7 w .p a-ar ch .c om ph ill ip s a ss oc ia te s a r c h i t e c t s i n t e r i o r s p l a n n e r s
N
O V
B
ID
S
ET
PA Registration: RA015197X
W
IS
SA
H
IC
K
O N
F
IR
E C
O M
PA
N
Y W
IN
D
O W
R
EP
LA
C
EM
EN
T
SCALE:1 EAST ELEVATION - DEMO
1/8" = 1'-0" SCALE:2 WEST ELEVATION - DEMO
1/8" = 1'-0"
SCALE:3 PARTIAL EAST ELEVATION - DEMO
1/8" = 1'-0"
AutoCAD SHX Text
GG
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REV.#
AutoCAD SHX Text
PROJECT NO:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text REV. Date
AutoCAD SHX Text REV. Notes
AutoCAD SHX Text Plans, specifications, reports, documents, or other information recorded on or transmitted as electronic media are subject to undetectable alteration, either intentional or unintentional, due to, among other causes, transmission, conversion, media degradation, software error or human alteration. all such documents are provided for informational purposes only and not as an end product nor as a record document. any reliance thereon is deemed to be unreasonable and unenforceable. All drawings, specifications, and related documents are copyright of the architect and must be returned upon request. reproduction of drawings, specifications, and related documents in part or whole is forbidden without the architects written permission. Do not scale drawings
AutoCAD SHX Text
245 RACE STREET
AutoCAD SHX Text
AMBLER, PA 19002
AutoCAD SHX Text 025 037.2
AutoCAD SHX Text 26.11.25
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
GROUND FLOOR
+0'-0"
FIRST FLOOR
+9'-11"
REMOVE EXIST.
CURTAINWALL SYSTEM IN
ITS ENTIRETY INCLUDING
ANY AND ALL FASTENING
CLIPS.
EXISTING INTERIOR
FINISHES, WOOD TRIM,
ETC. TO REMAIN AND BE
MODIFIED TO SUIT NEW
WORK
EXISTING INTERIOR
FINISHES, WOOD TRIM,
ETC. TO REMAIN AND BE
MODIFIED TO SUIT NEW
WORK
EXIST. ACT CLG. TO
REMAIN - CAREFULLY
REMOVE PORTIONS AS
NEEDED TO INSTALL
CURTAINWALL AND
REPLACE WHEN
FINISHED
EXISTING MTL. GRATE
LANDING TO REMAIN
EXISTING CONC.
STAIRS TO
REMAIN
REMOVE DOOR PANELS,
FRAME AND ALL
RELATED HARDWARE
BACK TO MASONRY
OPNG, PREPARE FOR
NEW WORK
REMOVE TRANSOM AND
FRAME IN ITS ENTIRETY
REMOVE ENTIRE CANOPY AND
ALL ASSOCIATED STRUCTURE
AND ACCESSORIES
EXIST. RADIATOR TO
BE REMOVED
SALVAGE WINDOW
TREATMENT FOR
REUSE
GROUND FLOOR
+0'-0"
FIRST FLOOR
+9'-11"
EXIST. RADIATOR TO
BE REMOVED
EXISTING INTERIOR
FINISHES, WOOD TRIM,
ETC. TO REMAIN AND BE
MODIFIED TO SUIT NEW
WORK
EXIST. ACT CLG. TO
REMAIN - CAREFULLY
REMOVE PORTIONS AS
NEEDED TO INSTALL
CURTAINWALL AND
REPLACE WHEN
FINISHED
EXISTING GRADE
EXIST. BRICK VENEER
REMOVE EXIST.
CURTAINWALL SYSTEM IN
ITS ENTIRETY INCLUDING
ANY AND ALL FASTENING
CLIPS.
SALVAGE WINDOW
TREATMENT FOR
REUSE
GROUND FLOOR
+0'-0"
FIRST FLOOR
+9'-11"
REMOVE EXIST.
CURTAINWALL SYSTEM IN
ITS ENTIRETY INCLUDING
ANY AND ALL FASTENING
CLIPS.
EXISTING INTERIOR
FINISHES, WOOD TRIM,
ETC. TO REMAIN AND BE
MODIFIED TO SUIT NEW
WORK
EXISTING INTERIOR
FINISHES, WOOD TRIM,
ETC. TO REMAIN AND BE
MODIFIED TO SUIT NEW
WORK
EXIST. ACT CLG. TO
REMAIN - CAREFULLY
REMOVE PORTIONS AS
NEEDED TO INSTALL
CURTAINWALL AND
REPLACE WHEN
FINISHED
EXISTING GRADE
EXIST. BRICK VENEER
EXIST. RADIATOR TO
BE REMOVED
SALVAGE WINDOW
TREATMENT FOR
REUSE
SALVAGE WINDOW
TREATMENT FOR
REUSE
W A
LL
S
EC
TI
O N
S D
EM
O
A4
E as t
Bu tle r A ve bl er
PA
.6
.7 w .p a-ar ch .c om ph ill ip s a ss oc ia te s a r c h i t e c t s i n t e r i o r s p l a n n e r s
N
O V
B
ID
S
ET
PA Registration: RA015197X
W
IS
SA
H
IC
K
O N
F
IR
E C
O M
PA
N
Y W
IN
D
O W
R
EP
LA
C
EM
EN
T
SCALE:1 DEMO SECTION THRU WINDOW
3/4" = 1'-0" SCALE:2 DEMO SECTION THRU CANOPY
3/4" = 1'-0" SCALE:3 DEMO SECTION THRU WALL
3/4" = 1'-0"
AutoCAD SHX Text
JBS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REV.#
AutoCAD SHX Text
PROJECT NO:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text REV. Date
AutoCAD SHX Text REV. Notes
AutoCAD SHX Text Plans, specifications, reports, documents, or other information recorded on or transmitted as electronic media are subject to undetectable alteration, either intentional or unintentional, due to, among other causes, transmission, conversion, media degradation, software error or human alteration. all such documents are provided for informational purposes only and not as an end product nor as a record document. any reliance thereon is deemed to be unreasonable and unenforceable. All drawings, specifications, and related documents are copyright of the architect and must be returned upon request. reproduction of drawings, specifications, and related documents in part or whole is forbidden without the architects written permission. Do not scale drawings
AutoCAD SHX Text
245 RACE STREET
AutoCAD SHX Text
AMBLER, PA 19002
AutoCAD SHX Text 025 037.2
AutoCAD SHX Text 26.11.25
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
MENS
BATHROOM
WOMENS
BATHROOM
CL
KITCHENLAUNDRY
RADIO
ROOM
HALL
HOSE
TOWER
CHIEF'S
OFFICE
MEETING
ROOM
COMPRESSOR
ROOM
APPARATUS
BAY
CL
STORAGE
DN
U P
D N
D N
D N
D N
D N
01 02 03
06 05 04
ABV
ABV
A12
A13
A12
A11
A11
A13
A13
4'-1" +/- V.I.F.
4'-1" +/- V.I.F.
4'-1" +/- V.I.F.
4'-1" +/- V.I.F.
4'-1" +/- V.I.F.
5'-0" +/- V.I.F.
5'-0" +/- V.I.F.
5'-0" +/- V.I.F.
'-1
2"
V.
I.F
3' -5
V.
I.F
3'
-5
V.
I.F
3' -5
V.
I.F
3'
-5
V.
I.F
4' -0
V.
I.F
KITCHENETTE
CLUB
ROOM
STORAGE STORAGESTORAGE
U P
UP
STORAGE
U P
A12
A11
A11
A
A13
A13
A13
'-1
2"
V.
I.F
A11
HOSE
TOWER
2'-9" +/- V.I.F.
A11
HOSE
TOWER
2'-9" +/- V.I.F.
A3
A2
A3
A2
HOSE
TOWER
2'-9" +/- V.I.F.
2' -9
V.
I.F
2'-9" +/- V.I.F.
2' -9
V.
I.F
WINDOW TAG
DOOR TAG
GENERAL NOTES
PLAN LEGEND
1. DO NOT SCALE DRAWINGS.
2. DIMENSIONS ARE TO FACE OF FRAMING OR FACE OF
BLOCK UNLESS NOTED OTHERWISE.
3. DOOR SIZES INDICATE SIZE OF DOOR ONLY NOT FRAME
SIZE. DOOR R.O. EITHER CENTERED IN SPACE OR 4 1/2" OFF
CORNER.
4. SEE EXTERIOR ELEVATIONS FOR ADDITIONAL WINDOW
AND/OR OPENING INFORMATION.
5. WHERE EXISTING CONSTRUCTION IS TO REMAIN AND IS
ALTERED. PROVIDE FINISHES TO MATCH EXISTING.
6. REMOVE PROJECTIONS, HANGERS, BOLTS, FASTENERS,
NAILS, HOOKS, LEDGERS, FURRING, BLOCKING, FROM ALL
EXISTING SURFACES. FILL GAPS AND PREPARE SURFACES
TO RECEIVE WORK AND FINISHES.
7. PROTECT, PATCH, AND REPAIR ALL ADJACENT SURFACES
WHICH ARE IMPACTED BY THE DEMOLITION, THE WORK, OR
REMOVAL OF ACCESSORIES TO THEIR ORIGINAL FORM AND
FINISH (UNLESS NOTED OTHERWISE)
8. REMOVE AND REINSTALL ALL EXISTING WALL MOUNTED
ITEMS TO REMAIN.
9. CONTRACTOR SHALL BE RESPONSIBLE FOR DAILY
CLEANUP OF ALL CONSTRUCTION DEBRIS. CONTRACTOR
TO PROVIDE DUMPSTERS ON SITE THROUGHOUT THE
PROJECT. DO NOT USE OWNER'S DISPOSAL RECEPTACLES
DUMPSTERS. COORDINATE LOCATION WITH OWNER AT
PROJECT KICKOFF MEETING.
10. V.I.F. (VERIFY IN FIELD BY CONTRACTOR) ALL ON SITE
DIMENSIONS AND EXISTING CONSTRUCTION DETAILS. NEW
WINDOW ELEVATIONS TO MATCH EXISTING.
11.CAREFULLY REMOVE ANY MEP ITEMS THAT ARE INSTALLED
IN THE EXISTING WINDOW SYSTEM. TEMPORARILY SECURE
AND REINSTALL IN NEW WINDOW SYSTEM IN THE SAME
EXISTING LOCATION.
EXISTING WALL CONSTRUCTION
PROJECT
NORTH
N
W
IN
D O
W L
O C
A
TI
O N
PL
A
N S
A10
SCALE:1 GROUND FLOOR PLAN
1/8" = 1'-0"
E as t
Bu tle r A ve bl er
PA
.6
.7 w .p a-ar ch .c om ph ill ip s a ss oc ia te s a r c h i t e c t s i n t e r i o r s p l a n n e r s
N
O V
B
ID
S
ET
PA Registration: RA015197X
W
IS
SA
H
IC
K
O N
F
IR
E C
O M
PA
N
Y W
IN
D
O W
R
EP
LA
C
EM
EN
T
SCALE:2 FIRST FLOOR PLAN
1/8" = 1'-0"
SCALE:3 TOWER PLANS
1/8" = 1'-0"
LOW
MID
TOP
AutoCAD SHX Text
GG
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REV.#
AutoCAD SHX Text
PROJECT NO:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text REV. Date
AutoCAD SHX Text REV. Notes
AutoCAD SHX Text Plans, specifications, reports, documents, or other information recorded on or transmitted as electronic media are subject to undetectable alteration, either intentional or unintentional, due to, among other causes, transmission, conversion, media degradation, software error or human alteration. all such documents are provided for informational purposes only and not as an end product nor as a record document. any reliance thereon is deemed to be unreasonable and unenforceable. All drawings, specifications, and related documents are copyright of the architect and must be returned upon request. reproduction of drawings, specifications, and related documents in part or whole is forbidden without the architects written permission. Do not scale drawings
AutoCAD SHX Text
245 RACE STREET
AutoCAD SHX Text
AMBLER, PA 19002
AutoCAD SHX Text 025 037.2
AutoCAD SHX Text 26.11.25
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
030201
(EX)(EX) (EX) (EX)APARATUS BAY
+9'-4"
GROUND FLOOR
+0'-0"
FIRST FLOOR
+9'-11"
NEW ALUMINUM
STOREFRONT SYSTEM
(TYP.)
EXISTING GABLE ROOF
OVER SIDE ENTRY DOOR
04 05 06
08 09
(EX)(EX)
GROUND FLOOR
+0'-0"
FIRST FLOOR
+9'-11" APARATUS BAY
+9'-4"
REPLACE WINDOWS WITH
INSULATED PANELS IN
NEW STOREFRONT
FRAMES
EXIST. STUCCO
WINDOW TAG
DOOR TAG
DRAWING KEY
B U
IL
D
IN
G
E
LE
V A
TI
O
N S
A11
E as t
Bu tle r A ve bl er
PA
.6
.7 w .p a-ar ch .c om ph ill ip s a ss oc ia te s a r c h i t e c t s i n t e r i o r s p l a n n e r s
N
O V
B
ID
S
ET
PA Registration: RA015197X
W
IS
SA
H
IC
K
O N
F
IR
E C
O M
PA
N
Y W
IN
D
O W
R
EP
LA
C
EM
EN
T
SCALE:1 SOUTH ELEVATION
1/8" = 1'-0"
SCALE:2 NORTH ELEVATION
1/8" = 1'-0"
AutoCAD SHX Text
GG
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REV.#
AutoCAD SHX Text
PROJECT NO:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text REV. Date
AutoCAD SHX Text REV. Notes
AutoCAD SHX Text Plans, specifications, reports, documents, or other information recorded on or transmitted as electronic media are subject to undetectable alteration, either intentional or unintentional, due to, among other causes, transmission, conversion, media degradation, software error or human alteration. all such documents are provided for informational purposes only and not as an end product nor as a record document. any reliance thereon is deemed to be unreasonable and unenforceable. All drawings, specifications, and related documents are copyright of the architect and must be returned upon request. reproduction of drawings, specifications, and related documents in part or whole is forbidden without the architects written permission. Do not scale drawings
AutoCAD SHX Text
245 RACE STREET
AutoCAD SHX Text
AMBLER, PA 19002
AutoCAD SHX Text 025 037.2
AutoCAD SHX Text 26.11.25
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
10 11 12 13
(EX)
APARATUS BAY
+9'-4"
EXISTING GABLE ROOF
OVER SIDE ENTRY DOOR
21 22 23
A13
(EX)
GROUND FLOOR
+0'-0"
FIRST FLOOR
+9'-11"
A12
A13
A13
A42
A42
A42
RE-INSTALL FLOODLIGHT
ON NEW SPANDREL PANEL
RE-INSTALL FLOODLIGHT
ON NEW SPANDREL PANEL
RE-INSTALL SECURITY
CAMERA ON NEW SPANDREL
PANEL
TEMPORARY ALUMINUM
COVER PANEL WHERE
FUTURE ENTRANCE
CANOPY CONNECTION IS
TO BE MADE
EXISTING MOTION
SENSOR
EXISTING MOTION
SENSOR
NEW ALUMINUM
CURTAINWALL SYSTEM
APARATUS BAY
+9'-4"
WINDOW TAG
DOOR TAG
DRAWING KEY
B U
IL
D
IN
G
E
LE
V A
TI
O
N S
A12
E as t
Bu tle r A ve bl er
PA
.6
.7 w .p a-ar ch .c om ph ill ip s a ss oc ia te s a r c h i t e c t s i n t e r i o r s p l a n n e r s
N
O V
B
ID
S
ET
PA Registration: RA015197X
W
IS
SA
H
IC
K
O N
F
IR
E C
O M
PA
N
Y W
IN
D
O W
R
EP
LA
C
EM
EN
T
SCALE:1 EAST ELEVATION
1/8" = 1'-0" SCALE:2 WEST ELEVATION
1/8" = 1'-0"
SCALE:3 PARTIAL EAST ELEVATION
1/8" = 1'-0"
AutoCAD SHX Text
GG
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REV.#
AutoCAD SHX Text
PROJECT NO:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text REV. Date
AutoCAD SHX Text REV. Notes
AutoCAD SHX Text Plans, specifications, reports, documents, or other information recorded on or transmitted as electronic media are subject to undetectable alteration, either intentional or unintentional, due to, among other causes, transmission, conversion, media degradation, software error or human alteration. all such documents are provided for informational purposes only and not as an end product nor as a record document. any reliance thereon is deemed to be unreasonable and unenforceable. All drawings, specifications, and related documents are copyright of the architect and must be returned upon request. reproduction of drawings, specifications, and related documents in part or whole is forbidden without the architects written permission. Do not scale drawings
AutoCAD SHX Text
245 RACE STREET
AutoCAD SHX Text
AMBLER, PA 19002
AutoCAD SHX Text 025 037.2
AutoCAD SHX Text 26.11.25
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
GROUND FLOOR
+0'-0"
FIRST FLOOR
+9'-11"
8' -1
1 4"
R O
U G
H O
PE
N
IN
G
'-4
1 4"
R O
U G
H O
PE
N
IN
G
1' -7
1 4"10 A42
A42
A42
A42
A42
EXISTING MTL.
GRATE LANDING
TO REMAIN
EXISTING CONC.
STAIRS TO
REMAIN
CURTAINWALL
SYSTEM
DOOR
SEMI-RIGID MINERAL WOOL
FIRESTOPPING / THERMAL
INSUL. BOARD
FIRE SEALANT OVER
SEMI-RIGID MINERAL WOOL
FIRE SAFING INSUL. BOARD
FIRE SEALANT OVER
SEMI-RIGID MINERAL WOOL
FIRE SAFING INSUL. BOARD
PATCH WALL AT REMOVED
RADIATOR W/ MATERIALS
MATCHING EXISTING
ADJACENT MATERIALS.
PROVIDE SMOOTH,
UNNOTICEABLE TRANSITION
SEMI-RIGID MINERAL WOOL
FIRESTOPPING / THERMAL
INSUL. BOARD
FIRE SEALANT OVER
SEMI-RIGID MINERAL WOOL
FIRE SAFING INSUL. BOARD
GROUND FLOOR
+0'-0"
FIRST FLOOR
+9'-11"
5' -0
1 4"
'-0 1 2"
M
AS
O N
R Y
/ R O
U G
H O
PE
N
IN
G
A42
A42
A42
A42
A42
SIM
CURTAINWALL
SYSTEM
EXISTING GRADE
EXIST. BRICK VENEER
FIRE SEALANT OVER
SEMI-RIGID MINERAL WOOL
FIRE SAFING INSUL. BOARD
PATCH WALL AT REMOVED
RADIATOR W/ MATERIALS
MATCHING EXISTING
ADJACENT MATERIALS.
PROVIDE SMOOTH,
UNNOTICEABLE TRANSITION
SEMI-RIGID MINERAL WOOL
FIRESTOPPING / THERMAL
INSUL. BOARD
SEMI-RIGID MINERAL WOOL
FIRESTOPPING / THERMAL
INSUL. BOARD
FIRE SEALANT OVER
SEMI-RIGID MINERAL WOOL
FIRE SAFING INSUL. BOARD
FIRE SEALANT OVER
SEMI-RIGID MINERAL WOOL
FIRE SAFING INSUL. BOARD
GROUND FLOOR
+0'-0"
FIRST FLOOR
+9'-11"
7' -1
4"
'-2
1 2"
M
AS
O N
R Y
/ R O
U G
H O
PE
N
IN
G
A42
A42
A42
A42
EXISTING GRADE
EXIST. BRICK VENEER
CURTAINWALL
SYSTEM
SEMI-RIGID MINERAL WOOL
FIRESTOPPING / THERMAL
INSUL. BOARD
FIRE SEALANT OVER
SEMI-RIGID MINERAL WOOL
FIRE SAFING INSUL. BOARD
FIRE SEALANT OVER
SEMI-RIGID MINERAL WOOL
FIRE SAFING INSUL. BOARD
PATCH WALL AT REMOVED
RADIATOR W/ MATERIALS
MATCHING EXISTING
ADJACENT MATERIALS.
PROVIDE SMOOTH,
UNNOTICEABLE TRANSITION
SEMI-RIGID MINERAL WOOL
FIRESTOPPING / THERMAL
INSUL. BOARD
PR
O
PO
SE
D W
A
LL
S
EC
TI
O
N S
A13
E as t
Bu tle r A ve bl er
PA
.6
.7 w .p a-ar ch .c om ph ill ip s a ss oc ia te s a r c h i t e c t s i n t e r i o r s p l a n n e r s
N
O V
B
ID
S
ET
PA Registration: RA015197X
W
IS
SA
H
IC
K
O N
F
IR
E C
O M
PA
N
Y W
IN
D
O W
R
EP
LA
C
EM
EN
T
SCALE:1 PROPOSED SECTION THRU WINDOW
3/4" = 1'-0" SCALE:2 PROPOSED SECTION THRU CAPPED OPENING
3/4" = 1'-0" SCALE:3 PROPOSED SECTION THRU WALL
3/4" = 1'-0"
AutoCAD SHX Text
JBS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REV.#
AutoCAD SHX Text
PROJECT NO:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text REV. Date
AutoCAD SHX Text REV. Notes
AutoCAD SHX Text Plans, specifications, reports, documents, or other information recorded on or transmitted as electronic media are subject to undetectable alteration, either intentional or unintentional, due to, among other causes, transmission, conversion, media degradation, software error or human alteration. all such documents are provided for informational purposes only and not as an end product nor as a record document. any reliance thereon is deemed to be unreasonable and unenforceable. All drawings, specifications, and related documents are copyright of the architect and must be returned upon request. reproduction of drawings, specifications, and related documents in part or whole is forbidden without the architects written permission. Do not scale drawings
AutoCAD SHX Text
245 RACE STREET
AutoCAD SHX Text
AMBLER, PA 19002
AutoCAD SHX Text 025 037.2
AutoCAD SHX Text 26.11.25
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
I
J
K
G H
C
B
D E F
ROUGH
OPENING (RO)
NO.
EXTERIOR WINDOW SCHEDULE
LOCATION
TYPE MAT'L FINISH
EXTERIOR COMMENTS
X
NOTES:
1. ALL ROUGH OPENING DIMENSIONS TO BE VERIFIED
IN FIELD
2. ---
FINISHES AND ABBREVIATIONS
AL ALUMINUM
WIDTH HEIGHT
GL-1 CLEAR INSULATED
FF FACTORY FINISH
GLAZING TYPES
WINDOW
SHADE
GLAZING
FIRST FLOOR
WINDOW TYPES
NOTES: 1. ALL GLAZING TO BE GLAZING GL-1 UNLESS NOTED OTHERWISE
2. SHADED PANELS INDICATE INSULATED SPANDREL PANEL, GLAZING TYPE GL-3
CLUB ROOM
LOCATION
AL AL1 3/4"7'-0"
DOOR FRAME
THICKWIDTH
DOOR LEAF
3'-0"
DOOR SCHEDULE
NO.
TYPE HEIGHT MATERIAL FINISHMATERIAL
COMMENTS
01 A PRE-FIN. * SEE EXTERIOR ELEV. / STOREFRONT SYSTEM
FINISH
HDWR
PRE-FIN
INT. /
EXT.
EXT
TYPE
AA
X
NOTES:
1. --
2. ---
FINISHES AND ABBREVIATIONS
AL ALUMINUM
GL GLASS
GS GALVANIZED STEEL
HM HOLLOW METAL
GLAZ
T = TEMPERED…
This is the start of the file's text. The full file is on GovTribe.