39443 Addendum 1.pdf
PDF 538 KB Posted
- Solicitation number
- ITB-08455
- Issued by
- St. Johns County, Florida
About this file
The document is an Addendum to an Invitation for Bid (IFB) issued by the St. Johns River Water Management District for the Pressure Cleaning and Painting of Water Control Structures. The IFB covers the pressure cleaning, painting, and miscellaneous repairs to several water control structure buildings in Brevard County, Florida to maintain their appearance and structural integrity. The Addendum provides clarifications and changes, including the required paint specification, to the original IFB. The bid due date remains 2:00 p.m. on Friday, May 3, 2024. A non-mandatory pre-bid meeting was held on April 11, 2024.
The attached paint specification details the Loxon XP Waterproofing Masonry Coating-Flat to be used for the project. Key requirements include a two-coat application, wet mil thickness of 14.5-18.5 mils per coat, and a total dry film thickness of 13-16.8 mils with no more than 10 pinholes per square foot to achieve the necessary waterproofing performance. Respondents must acknowledge receipt of this Addendum on the Bid Form.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| IFB 39443 Pressure Cleaning final.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Page | 1
DATE: April 16, 2024
TO: Prospective Respondents
FROM: Amy Lucey, Procurement Specialist
SUBJECT: Addendum #1 to Invitation for Bid, # 39443, Pressure Cleaning and Painting of Water
Control Structures
The following clarifications/changes are provided for your information. Please make all appropriate changes to your bid documents.
Q1: I was on the pre bid meeting for this job and it was said the kind paint for the steel doors.
it was said that it would be put into an addendum.
A1: Please see attached Manufacturer’s Paint Specification.
Attachments:
Luxon Waterproofing Masonry Coating-Flat Pre-bid meeting sign in Sheet Pre-bid meeting recording
NOTE: The Bid Due Date remains 2:00 p.m. Friday, May 3, 2024 Please acknowledge receipt of this Addendum on the Bid Form provided in the proposal package.
If you have any questions, please e-mail me at alucey@sjrwmd.com.
mailto:alucey@sjrwmd.com
115.10
Loxon® XP Waterproofing Masonry Coating-Flat LX11-50 Series
CHARACTERISTICS
Loxon XP is an exterior, high build coating that provides excellent flexibility, durability and weather resistance. This product will protect against wind-driven rain when used on concrete, CMU, stucco and shotcrete-gunite. It is highly alkali and efflorescence resistant. This may be applied to a surface with a pH of 6 to 13.
Apply directly to fresh concrete (at least 7 days old).
Shotcrete/gunite surfaces may be painted after 3 days.
Can be applied over high pH (up to 13) substrates, no primer required.
Can be applied down to 35°F.
Color: Most Colors 1 coat system, brush, roller, or spray applied, coverage per coat:
Wet mils: 14.5-18.5 Dry mils: 6.5-8.4 Coverage sq.ft. per gallon 85-110 Can be applied up to 40 mils wet.
Coverage will vary with the substrate and the texture.
Coverage on porous & rough stucco 80 square feet per gallon.
Drying Schedule @ 50% RH: temperature and humidity dependent.
@35-45°F @ 45°F+ Touch: 6 hrs 4 hrs Recoat: 24-48 hrs 24 hrs
Drying time is temperature, humidity, and film thickness dependent.
Finish: 0-10 units @ 85° Tinting with CCE only:
Base oz.per Strength gallon Extra White 0-6 SherColor Deep Base 4-12 SherColor Ultradeep 10-12 SherColor Light Yellow 0-12 SherColor
Extra White LX11W0051 (may vary by color)
V.O.C. (less exempt solvents):
less than 50 grams per litre;0.42 lbs. per gallon
As per 40 CFR 59.406 Volume Solids: 45 ± 2% Weight Solids: 61 ± 2% Weight per Gallon: 11.46 lb Flash Point: N.A.
Vehicle Type: Proprietary Acrylic Shelf Life: 36 months,unopened
Mildew Resistant:
This coating contains agents which inhibit the growth of mildew on the surface of this coating film. Passes
ASTM D3273/D3274
COMPLIANCE
As of 2/4/2022, Complies with:
OTC Yes OTC Phase II Yes S.C.A.Q.M.D Yes CARB Yes CARB SCM 2007 Yes CARB SCM 2020 Yes Canada Yes LEED® v4 & v4.1 Emissions N.A.
LEED® v4 & v4.1 V.O.C. Yes EPD-NSF® Certified No MIR-Manufacturer Inventory No MPI ® Yes SWRI®- Wall Coating Yes
APPLICATION
Temperature:
minimum 35°F The following is a guide. Changes in pressures and tip sizes may be needed for proper spray characteristics.
Always purge spray equipment before use with listed reducer. Any reduction must be compatible with the existing environmental and application conditions.
Reducer: Do not reduce Airless Spray:
Pressure 2300 p.s.i.
Tip .021 inch Brush Use a nylon/polyester brush Roller Cover Use a ½ to 1½ inch nap synthetic roller cover.
The substrate and its condition will determine the application procedure. Considerations to minimize pinholes:
• 2 coat application with overnight drying between coats
• Spray application with backrolling
• Power rolling Spray and backroll on porous & rough stucco to achieve required film build and a pin-hole free surface.
When the air temperature is at 35°F, substrates may be colder. Prior to painting, check to be sure the air, surface, and material temperatures are above 35°F and at least 5°F above the dew point. Avoid using if rain or snow is expected within 2-3 hours.
Do not apply at air or surface temperatures below 35°F or when air or surface temperatures may drop below 35°F within 48 hours.
Do not reduce.
APPLICATION TIPS
For proper waterproofing performance and to resist alkalies, 2 coats of the coating MUST be applied between 14.5 -18.5 mils wet per coat.
A total dry film thickness of 13 - 16.8 mils of topcoat and a surface with 10 or less pinholes per square foot is required for a waterproofing system.
For extremely porous block a coat of Loxon Block Surfacer may be required to achieve a pinhole free surface.
For rehabilitating existing concrete water tanks, additional products may be used.
RECOMMENDED SYSTEMS
Concrete, Stucco, Concrete Block, CMU, Split-face Block, and other Cementitious surfaces 1 coat Loxon Acrylic Block Surfacer
(if needed) or Loxon Conditioner (if needed)
1-2 coats Loxon XP
Previously Coated in good condition:
After power washing, apply 1 coat of Loxon XP over the surface.
Incidental Wood:
1 coat Exterior Latex Wood Primer 1- 2 coats Loxon XP
Incidental Metal:
(steel, galvanized, or aluminum):
1 coat Pro Industrial Pro-Cryl Primer 1-2 coats Loxon XP Waterproofing System:
• Two coats of topcoat
• 6.5 to 8.4 mils d.f.t. per coat
• 13 to 16.8 mils total dry film thickness
• 10 or less pinholes per square foot
2/2022 www.sherwin-williams.com continued on back http://www.sherwin-williams.com/
Loxon® XP Waterproofing Masonry Coating-Flat
SURFACE PREPARATION
WARNING! Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper containment and cleanup. For more information, call the National Lead Information Center at 1- 800-424-LEAD (in US) or contact your local health authority.
Remove all surface contamination by washing with an appropriate cleaner, rinse thoroughly and allow to dry. Scrape and sand peeled or checked paint to a sound surface. Sand glossy surfaces dull. Seal stains from water, smoke, ink, pencil, grease, etc. with the appropriate primer-sealer.
Recognize that any surface preparation short of total removal of the old coating may compromise the service length of the system.
Concrete, CMU, Stucco:
On tilt-up and poured-in-place concrete, commercial detergents and sandblasting may be necessary to remove sealers, release compounds, and to provide an anchor pattern.
Concrete and mortar must be cured at least 7 days at 75°F. Fill bugholes, air pockets, cracks, and other voids with an elastomeric patch or sealant. Rough surfaces can be filled to provide
SURFACE PREPARATION
Mildew:
Prior to attempting to remove mildew, it is always recommended to test any cleaner on a small, inconspicuous area prior to use. Bleach and bleaching type cleaners may damage or discolor existing paint films. Bleach alternative cleaning solutions may be advised.
Mildew may be removed before painting by washing with a solution of 1 part liquid bleach and 3 parts water. Apply the solution and scrub the mildewed area. Allow the solution to remain on the surface for 10 minutes. Rinse thoroughly with water and allow the surface to dry before painting. Wear protective eyewear, waterproof gloves, and protective clothing. Quickly wash off any of the mixture that comes in contact with your skin. Do not add detergents or ammonia to the bleach-water solution.
PHYSICAL PROPERTIES
Do not paint on wet surfaces.
LX11W0051
Wind-Driven Rain Test : Pass Method: ASTM D6904 7 day cure 2 coats Loxon XP @ 8.1 mils d.f.t. per coat Water Vapor Permeance:
(perms) 18.03 grains/h-ft²-in Hg.
Method: ASTM D1653 7 day cure @ 73°F & 50%
RH: Method B, Condition A-Wet cup 2 coats Loxon XP @ 8.1 mils d.f.t. per coat Elongation : 312% Method: ASTM D412, 7 day cure @ 72°F
CAUTIONS
For exterior use only.
Protect from freezing.
Non-photochemically reactive.
Not for use on horizontal surfaces (floors, roofs, decks, etc.) where water will collect.
Not for use below grade. Will not withstand hydrostatic pressure.
Before using, carefully read CAUTIONS on label.
ZINC. Use only with adequate ventilation. To avoid overexposure, open windows and doors or use other means to ensure fresh air entry during application and drying. If you experience eye watering, headaches, or dizziness, increase fresh air, or wear respiratory protection (NIOSH approved) or leave the area. Avoid contact with eyes and skin. Wash hands after using.
Keep container closed when not in use. Do not transfer contents to other containers for storage. FIRST AID:
In case of eye contact, flush thoroughly with large amounts of water. Get medical attention if irritation persists. If swallowed, call Poison Control Center, hospital emergency room, or physician immediately.
WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. DO NOT TAKE
INTERNALLY. KEEP OUT OF THE REACH OF
CHILDREN.
HOTW 2/4/2022 LX11W0051 27 00
FRC, SP
CLEANUP INFORMATION
Clean spills, spatters, hands and tools immediately after use with soap and warm a smooth surface. 2 coats & 50% RH 20 inch per minute
Loxon XP @ 8.1 mils d.f.t. per coat water. After cleaning, flush spray equipment Incidental Metal:
Wash to remove any oil, grease, or other surface contamination. All corrosion must be removed with sandpaper, wire brush, or other abrading method. Primer required.
Incidental Wood:
Sand any exposed wood to a fresh surface.
Patch all holes and imperfections with a wood filler or putty and sand smooth. All patched areas must be primed. Primer required.
Sealing and Patching—After cleaning the surface thoroughly, prime the concrete surface with Loxon XP, apply an elastomeric patch or sealant if needed, allow to dry, then topcoat.
To improve the performance, consider:
• Use caution when preparing the substrate to create a uniform surface.
• Cracks, crevices, and through-wall openings must be patched with an elastomeric patch or sealant.
• Fill voids and openings around window and doors with an elastomeric patch or sealant.
• Stripe coat all inside and outside corners and edges with 1 coat of Loxon XP coating.
Tensile Strength : 295 p.s.i.
Method: ASTM D412, 7 day cure @ 72°F
& 50% RH 20 inch per minute 2 coats Loxon XP @ 8.1 mils d.f.t. per coat Flexibility:
Method: ASTM D522, 9 mils d.f.t.,1 day cure Result: Pass 1/8 inch Alkali Resistance:
Method: ASTM D1308, 7 day cure,
11.25 mils d.f.t.
Result: Pass Chloride Ion Permeability:
Result: 243 coulombs Result: “Very Low” Permeability Class CO2 Diffusion (anti-carbonation):
Method: ASTM F2476 Result: 344 meters equivalent air thickness >50 meters to pass
8.0 g/m²/24 hrs
Crack Bridging: Class A5 Pass Method: EN 1062-7 Method A Result: up to 2.5 mm @-10°C Efflorescence:
Method: ASTM D7072-19
1 coat, 1 day cure, 7.2 d.f.t.
Result: Pass
Adhesion:
Method: ASTM D4541
2 coats, 7 day cure, 7.2 d.f.t. per coat Result: 375 average p.s.i.
with a compliant cleanup solvent to prevent rusting of the equipment. Follow manufacturer’s safety recommendations when using solvents.
The information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin-Williams Company. Such information and recommendations set forth herein are subject to change and pertain to the product offered at the time of publication. Consult your Sherwin-Williams representative or visit www.paintdocs.com to obtain the most current version of the PDS and/or an SDS.
http://www.paintdocs.com/
ST. JOHNS RIVER WATER MANAGEMENT DISTRICT
SIGN-IN SHEET FOR ATTENDEES
IFB # 39443 NON-MANDATORY PRE-BID MEETING
10:00 am, Thursday, April 11, 2024
Pressure Cleaning & Painting of Water Control Structures
Attendee (Print Legibly):
Address:
City /State/Zip:
p
Bid Documents Picked up today:
QYes or Q No
Address:
City /State/Zip:-.:> YallY\. ~~
Bid Documents Picked up today: Email :
0Yes or o~
5f{(WMIJ Address:
City /State/Zip: f ~lwi Bid DocumentsJ.'}tked up to ay:
0 Yes or W No
Attendee (Print Legibly):
~ Lq_r~ Firm Name:
CJ Geo LJtp Address:
g-g.g )<.J City /State/Zip:
ft:l. I W\ <, Email:
7<f"l'(0 Bid Documents Picked up today: Email :
0 Yes or 0 No
~1;; - e~ 5, oo4r
Phone:
2 , _ q7~- l&f 17
Phone:
1'12-ftoJ·-5L/o I s.·1 . os, R~vised l )7 1 ); ; -· ~ Page J
Business Card Provided D Or fill in contact information
Business Card Provided D Or fill in contact information
Business Card Provided
Or fill in contact information
Business Card Provided
Or fill in contact information
' ST. JOH NS RIVER WATER MANAGEMENT DISTRICT
IFB # 39443 NON-MANDATORY PRE-BID MEETING
10:00 am, Thursday, April 11 , 2024
Pressure Cleaning & Painting of Water Control Structures
Attendee (P rint Legibly): Phone: Business Card Provided
Or fill in contact in formation
City /State/Zip:
Bid Documents Picked up today: Email:
QYes or Q o
Attendee (Print Legibly): I Phone: I Business Card Provided D Or fill in contact informati on
Firm FT~< R~v-~ Address:
City /State/Zip:
Bid Documents Picked up today:
Q Yes or Q No I Email :
Attendee (Print Legib ly):
l~i~ k.oS I Phone: I Business Card Provided LJ .___
..1. r~e.. Or fill in contact information
Firm ame:
Address:
City /State/Zip:
Bid Documents Picked up today:
0 Yes or 0 No I Email :
Attendee (Print Legibly): Phone: Business Card Provided
Or fill in contact information
City /State/Zi p:
Bid Documents Picked up today: Email:
0 Yes or Q No
8, 11 05; r--~;ised .:n .5; 5 l · .: Page 2
' ST. JOHNS RIVE R WATER MANAGEMENT DISTRICT
IFB # 39443 NON-MANDATORY PRE-BID MEETING
10:00 am, Thursday, April 11, 2024
Pressure C leaning & Painting of Water Control Structures
Attendee (Print Legibly): I Phone:
'fY1r .,.J 6-rS P ..Ph..
Firm am~ 0 -s- ~ r 0" Address:
City /State/Zip:
Bid Documents Picked up today:
QYes or 0 No I Emai l:
Attendee (Print Legibly) : I Phone:
~LYU
Firm N{;= )h, O / esx_}e Address:
City /State/Zip:
Bid Documents Picked up today:
0Yesor QNo I Email:
Phone:
City /State/Zip:
Bid Documents Picked up today: Emai l:
0 Yes or 0 No
Attendee~i~ Ji~ I Phone:
Firm a~ ~-r~ 6-iY\.~s ~ ~ rvUJV'V-\ Address :
City /State/Zip:
Bid Documents Picked up today:
0 Yes or 0 No I Email :
8.'l 'O~; "'\~ ,-;s~d l /Z. :i; :i.· ' Page 3
I Business Card Provided D Or fill in contact info rmation
I Business Card Provided D Or fill in contact information
Business Card Provided D Or fill in contact information
I Business Card Provided LJ
' ST. JOHNS RIVER WATER MA NAGEMENT DISTRICT
IFB # 39443 NON-MANDATORY PRE-BID MEETING
10:00 am, Thursday, April 11 , 2024
Pressure Cleaning & Painting of Water Control Structures
Attendee (Print Legibly): Phone:
Firm ame:'A.
Address:
City /State/Zip:
Bid Documents Picked up today: Email:
QYes or Q o
Attendee (Print Legibly): Phone:
Address:
City /State/Zip:
Bid Documents Picked up today: Email :
0 Yes or 0 No
Attendee (Print Legibly): I Phone:
F irm Nad h'i Gfo~J Address:
City /State/Zip :
Bid Documents Picked up today:
0 Yes or 0 No I Email :
Attendee (Print Legibly): Phone:
Address:
City /State/Zip :
Bid Documents Picked up today: Email:
0 Yes or 0 No
Business Card Provided D Or fill in contact information
Business Card Provided
Or fill in contact information
I Business Card Provided D Or fill in contact informati on
Business Card Provided D
ST. JOHNS RIVER WATER MANAGEMENT DISTRICT
SIGN-IN SHEET FO R ATTEN DEES
lFB # 39443 NON-MANDATORY PRE-BID MEETING 10:00 am, T hu rsday, April 11, 2024
Pressure Cleaning & Painting of Water Control Structures
Attendee (Print Legibly): Phone:
~-vi~ Firm Name:
Address:
City /State/Z ip:
Bid Documents Picked up today: Email :
QYes or 0 No
Attendee (Print Legibly): Phone:
Address:
City /State/Zip :
Bid Documents Picked up today: Email :
0 Yes or 0 No
Attendee (Print Legibly): I Phone:
Firm Name:
Address:
City /State/Zip :
Bid Documents Picked up today:
0 Yes or 0 No I Email :
Attendee (Print Legibly): I Phone:
Firm ame:
Address:
City /State/Zip:
Bid Documents Picked up today:
0 Yes or 0 o I Email :
8. I 05; Re""'''"J u 5; 5 . . 5 Page 5
Business Card Provided D Or fill in contact info rmation
Business Card Provided D Or fill in contact info rmation
I Business Card Provided D Or fill in contact information
I Business Card Provided D Or fill in contact in formation
| Spec Masonry Coating Waterproofing Product Data.pdf |
| 115.10 |
| LX11-50 Series |
| CHARACTERISTICS |
| 1 coat system, brush, roller, or spray applied, coverage per coat: |
| Drying Schedule @ 50% RH: temperature and humidity dependent. |
| Tinting with CCE only: |
| Extra White LX11W0051 |
| V.O.C. (less exempt solvents): |
| COMPLIANCE |
| OTC Phase II Yes |
| CARB SCM 2007 Yes |
| APPLICATION |
| Temperature: |
| Airless Spray: |
| APPLICATION TIPS |
| RECOMMENDED SYSTEMS |
| Concrete, Stucco, Concrete Block, CMU, Split-face Block, and other Cementitious surfaces |
| Previously Coated in good condition: |
| Incidental Wood: |
| Incidental Metal: |
| Waterproofing System: |
| Waterproofing Masonry Coating-Flat |
| SURFACE PREPARATION |
| Concrete, CMU, Stucco: |
| SURFACE PREPARATION |
| Mildew: |
| PHYSICAL PROPERTIES |
| Wind-Driven Rain Test : Pass |
| CAUTIONS |
| CLEANUP INFORMATION |
| Incidental Metal: |
| Incidental Wood: |
| Flexibility: |
| Alkali Resistance: |
| Chloride Ion Permeability: |
| Efflorescence: |
| Adhesion: |
File details come from the government source that posted it. Updated .