This is a Job Specification for shipboard maintenance work aboard the USS Rushmore (LSD-47). The specification details the replacement of nonskid deck covering on the Forward 04 Level Weather Deck and associated preservation work, with an anticipated award date of 11/3/2027 and a period of performance from 1/25/2027 through 7/31/2027. The work encompasses approximately 930 square feet of nonskid deck covering replacement, 210 square feet of preservation work on deck surfaces (up to 11 inches above vertical surfaces), 30 square feet of deck plate replacement (including 5 square feet of pitted surface treatment), and 2 square feet of bulkhead plate replacement on the port side longitudinal bulkhead at 6 feet off centerline. Additional work includes removal and reinstallation of 2 vertical ladder clips and one watertight door assembly (Closure Number 04-19-2, 26 inches width by 66 inches height, left-hand configuration).
The specification requires contractors to submit Marine Chemist certificates, inspect and test countermeasure washdown nozzles and deck drains prior to and upon completion of work, remove and replace damaged structural components fabricated from ASTM A36 and ABS Grade A steel materials, perform welding in accordance with specification 009-12, conduct operational testing of the watertight door assembly through four complete cycles, and accomplish surface preparation and preservation work per specification 009-32 to SSPC-SP-11, SSPC-SP-3, and SSPC-SP-2 standards. Government-furnished materials include steel plates, welding electrodes, thermal and acoustic insulation blocks, adhesives, fasteners, hinge kits, and silicone compounds. All work must comply with referenced naval drawings and specifications including structural modification drawings, deck house installation drawings, door modification specifications, and insulation detail standards.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 38E9367103R_00_A01.pdf | ||
| N6264927Q0041.pdf | ||
| 38E9367202R_00_A01.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Youko.Mori.ja Text Box 1301426833
Shio/HULL NO. Ship/HULL NAME
JON:
ICN: Rev: Key Op:
LSD-47 USS RUSHMORE 38E84&1484 A01
TITLE:
Nonskid Deck Covering on FWD 04 Level Weather Deck; replace
1.1 Title: Nonskid Deck Covering on FWD 04 Level Weather Deck; replace
1. 2 Location of Work:
1.2.1 Weather Deck 04 Level, Frames 13-21
1.2.2 Modular RAM Equipment Room No. One (04-19-0-Q)
1.2.3 RAM Maintenance Enclosure No. One (04-14-0-Q)
1.2.4 RAM Equipment Storeroom (04-19-0-A)
1.2.5 Troop Living Space (Assault Craft Detachment) (04-21-0-L)
1.2.6 Passage (04-21-1-L)
1.2.7 Fan Room (04-21-3-Q)
1.2.8 Troop Living Space (03-14-0-L)
1.2.9 Troop Washroom and Water Closet (03-19-0-L)
1.2.10 Water Heater Room (03-19-1-Q)
1.2.11 Passage (03-19-3-L)
1.2.12 Passage (03-19-4-L)
1.2.13 Troop Shower and Drying Area (03-20-0-L)
1.2.14 Troop Living Space (03-21-0-L)
1.2.15 Passage (03-21-01-L)
1.3 Identification:
1.3.1 A Total of (930 SF) of Nonskid Deck Covering on FWD 04 Level Weather Deck Including Scuttle Panel, Located in 1.2.1
1.3.2 A Total of (210 SF) of Preservation on Deck Including Up to 11 Inch (Maximum Height) above Vertical Surface of Structure Member, Bulkhead, Foundation, Scuttle Panel, Deck Fitting, Deck Edge and Coaming, Located in 1.2.1
1.3.3 A Total of (30 SF) of Deck Plate to be Replaced, Located in 1.2.1
1.3.3.1 A Total of (5 SF) of Pitted Surface Located in 1.2.1
Shin/HULL NO. Shin/HULL NAME ICN: Rev: Key Op:
LSD-47 USS RUSHMORE JON: 38E9481494 A01
TITLE:
Nonskid Deck Covering on FWD 04 Level Wuther Deck; replace
1.3.4 A Total of (2 SF) of Bulkhead Plate to be Replaced, Port Side Longitudinal Bulkhead at 6 Feet off Center Line, Located in 1.2.1 and 1.2.2, See ENCLOSURE (A)
2. REl'ERBNCES:
1.3.4.1 Quantity (2 EA), Vertical Ladder Clip on Port Side
Longitudinal Bulkhead at 6 Feet off Center Line
1.3.4.2 Quantity (One AY), Watertight Door Assembly, Closure
Number: 04-19-2, Clear Opening Size: 26 Inch Width by 66 Inch Height, Left Hand
2627 'f.W\. 3/31/2(p 'f.\'.\ori
2 . 1 Standard Items ( FY~
2.2 139-6102529 Rev D, Unit 445 04 Deck FRS 13-21 C/L
2.3 155-7445969, Deck House Installation RAM Equipment Room No. One
2.4 167-7445989, Structural Door MODS 04 Level
2.5 571-7445942, MODS, RAS STA One and 2 INCID RAM MK-31 INSTL
2.6 612-7445948, RAM Rails 04 and 05 LVLS FWD
2.7 801-7445990, C & A MOD INCDT RAM INSTL
2.8 Sl604-860091 Rev K, Ladders, Vertical, Assemblies and Details
2.9 803-6397268 Rev B, Doors Watertight, Quick Acting Arrangement
2.10 635-6101904 Rev C, Insulation - Detail - Hull
2.11 635-6101907 Rev C, Insulation ARR Thermal and Acoustic 03 Level and Above
2.12 S9086-VH-STM-010/CH-635/Rev 3, Thermal, Fire and Acoustic Insulation
(V) "REPOR~"
3.1 Submit one legible copy of Marine Chemist certificate to SUPERVISOR including certified location.
3.2 Prior to commencement of any nonskid work, inspect each counter measure washdown nozzle and test each deck drain to ensure that each washdown nozzle and drain are not clogged and damaged.
Shi ULL NO. Shi ULL NAME ......;;;;..a=L---SD--... ---7-----i-'u'"'"'s;..&s---R...;;U.....;;S._H __ M;;...O ..... R_E __ ----i JON:
ICN:
38E91&7181
Rev: Key Op:
A01
TITLE:
Nonskid Deck Covering on FWD 04 Level Weather Deck; replace
(V) "REPORT"
3.2.1 Submit one legible copy of a report listing results of the requirement of 3.2 to SUPERVISOR.
3.2.2 Remove each damaged existing fastener, tap each existing thread hole, and install each new fastener of deck drain strainer where missing or damaged.
3.3 Remove each existing nonskid deck covering and coating listed in
1.3.1 and 1.3.2 for the visual inspection.
3.3.1 Visually inspect each existing deck plate located in 1.2.1 to determine each repair area listed in 1.3.3 through 1.3.4, using 2.2 through
2.7 for guidance.
(V) "REPORT"
3.3.1.1 Submit one legible copy of a report listing results
of the requirement of 3.3.1 to SUPERVISOR.
3.4 Remove each existing damaged section, template, fabricate and install each new deck and bulkhead plate listed in 1.3.3 and 1.3.4 determined by the visual inspection in 3.3.1 out of new 3/16 thick steel plate conforming to ASTM A36 and ABS Grade A, using 2.2 through 2.11 for guidance.
3.4.1 Remove each existing, template, fabricate and install each new vertical ladder clip listed in 1.3.4.1 out of new 1/4 inch thick steel plate conforming to ASTM A36, using 2.6 and 2.8 for guidance.
3.4.1.1 Remove each existing vertical ladder to facilitate
each repair work. Upon completion of each repair work, install it with each new fastener where missing or damaged.
3.4.2 Remove each existing watertight door assembly listed in
1.3.4.2 to facilitate each repair work of each bulkhead plate listed in 1.3.4.
Upon completion of each repair work, install it with each new gasket, part and fastener where missing or damaged, using 2.4 and 2.9 for guidance.
3.4.2.1 Adjust each dogging mechanism assembly for correct
operation.
3.4.3 Grind out and build up weld each pitted surface listed 1.3.3.1 determined by the visual inspection in 3.3.1.
3.4.4 Accomplish the requirements of 009-12 of 2.1, including Table 2, Column A, Lines One through 7 for welding.
3.4.5 Accomplish the requirements of 009-25 of 2.1 for a chalk test of each installed watertight door assembly listed in 1.3.4.2.
ShlDIHULL NO. ShlDIHULL NAME ICN: Rev: Key Op:
JON: LSD-47 USS RUSHMORE 38E8461494 A01
TITLE:
Nonskid Dack Covering on FWD 04 Leval Weather Dack; replace
3.4.6 Accomplish the requirements of 009-25 of 2.1 for a local air hose test or water hose test of each new welded section of watertight boundaries and each installed watertight door assembly. Allowable leakage:
None.
3.5 Accomplish the requirements of 009-32 of 2.1, including Table 2, Line 21, Columns A, B, C and E and Line One, Column G for each area listed in 1.3.1 and 1.3.2.
3.5.1 Power tool clean each narrow area to SSPC-SP-11 where blast nozzle cannot reach.
3.5.1.1 Power tool clean each narrow area to SSPC-SP-3 where
power tool in 3.5.1 cannot reach.
3.5.1.2 Hand tool clean each narrow area to SSPC-SP-2 where
power tool in 3.5.1.1 cannot reach.
3.5.2 Apply new marking on the nonskid surfaces using color topping, manufacturer's instructions.
3.6 Upon completion of the work, inspect each counter measure washdown nozzle and test each deck drain to ensure that each deck drain is not clogged.
(V) (G) "OPERATIONAL TEST"
3.7 Accomplish an operational test of each installed watertight door assembly listed in 1.3.4.2 by opening and closing through four complete cycles. Allowable binding and sticking: None. -8130
3.8 Accomplish the requirements of 009-32 of 2.1 for cleaning and preservation of each new and disturbed surface to match surrounding areas.
3.8.1 A brush or spray may be used as a paint application for acoustic insulation in 635-7.2.4 of 2.12 as applicable.
4. NOTES:
4.1 Initial Condition - FWD 04 level weather deck was damaged and needs repair and preservation.
4.2 SRF Tool Room will issue pressure gauges as required.
Ship/HULL NO. Ship/HULL NAME ICN: Rev: Key Op:
LSD-47 USS RUSHMORE JON: 38&9461491 A01
TITLE:
Nonskid Deck Covering on FWD 04 Level Weather Deck; replace
5. GOVERNMENT FURNISHED MATERIAL (GIM) :
5.1 Government Furnished Material as follows.
MATERIAL UST
M QTY
ITEM PC REF I STOCK !HAZ DOC RECD/ Para NO. NO. NO. C DESCRIPTION NUMBER w., NO. UNIT No.
001 M PLATE.METAL, 7.65#, 3/18"THK 9B 9515 002671176 N 2/PM 3.4
X 72'WIDTH X 10'LENGTH,
STEEL, ASTM A36, FOR DECK
PLATE
002 M SHEET,METAL, 7.65#, 3/18"THK 9B 9515 002388617 N 2/PM 3.4
X 48"WIDTH X 8'LENGTH,
STEEL, MIL-S-22898 GRADE A,
FOR BULKHEAD PLATE
003 M BAR.METAL, 1/4"THKX 9B 9510 001891558 N 12/FT 3.4
2'WIDTH, 12 FT CONTINUOUS
LENGTH STEEL ASTM A36
004 M ELECTRODE, VIIELDING, 9G 3439 SA4742863 N 3/CN 3.4
7018M, SMAW, 1/8"DIAX
14"LG, 10LB/CN, MIL-E-
22200/10 P/N:265014110
005 M ELECTRODE, V\IELDING, 9G 3439 SA4742881 N 2/CN 3.4
7018M, SMAW, 3/32"DIA X
14"LG, 10LBICN, MIL•E·
22200/10 P/N:255014102
006 M ROD.WELDING, MIL-E-23765-1, 9B 3439 009008737 -¥ 1/CO 3.4
TYPE: MIL-708-2, 1/16"DIA X
36"LG 5LB/CO
007 M INSULATION BLOCK, 9Q 5640 008096312 N 1/BX 3.4
THERMAL, 1"THK X 2W X 3'L,
MIL-DTL-32585, TYPE-1, FORM
1 FACING B 20EAJBX
008 M INSULATION BLOCK, 9Q 5640 008096315 N 1/BX 3.4
THERMAL, 2'7HK X 2W X 3'L,
MIL-DTL-32585, TYPE-1, FORM
1 FACING B. 10EAIBX
009 M SOUND CONTROLLING, 9Q 5640 007565866 N 1/BX 3.4
BOARD, 2"THK X 2W X 3'L,
MIL-DTL-32585, TYPE-2, FORM-
1 FACING-C 10EA/BX
010 M CAP,SNAP FASTENER, FOR 9B 5325 0073778-18 N 1/HD 3.4
3/16"DIA STUD, ALUMINUM
ALLOY
011 M TAPE,TEXTILE, FOR 9B 8315 002671632 N 3/RC 3.4
INSULATION, 'ZWX 50YD/RO,
MIL-C-20079H, TYPE-2, CLASS-
012 M ADHESIVE, MIL-DTL-3316D, 98 8040 002738708 y 1/GL 3.4
CLASS-1, GRADE-A, COLOR:
WHITE 1GUCN
013 M MATTING,FLOOR, 9Q 7220 010249040 N 1/RC 3.4
ELECTRICITY RESISTANT AND
FIRE RESISTANT, COLOR:
BLUE MARBLE, 1/8"THK, 36"W
X 75'L/RO, MIL-DTL-15562
TYPE-I
014 M ADHESIVE, FOR BONDING 98 8040 005824596 y 1/GL 3.4
RESILIENT DECK COVERINGS,
MIL-A-21016 1CN/GL
ShlDIHULL NO. ShlDIHULL NAME ICN: Rev: Key Op:
LSD-47 USS RUSHMORE JON: 38E8461484 A01
TITLE:
Nonskid Deck Covering on FWD 04 Level Weather Deck; replace
MATERIAL LIST
M QTY
ITEM PC REF I STOCK HAZ DOC REQD/ Para NO. NO. NO. C DESCRIPTION NUMBER MA1 NO. UNIT No.
015 C RUBBER STRIP, SOLID, 9B 5330 013717183 N 1/SL
SILICON RUBBER, A-A-59588B,
CLASS 3B, GRADE 30, 1/2"THK
X 1-1/4"WIDTH X 160'LENGTH
016 C MACHAL T HINGE KIT, 98 2040 SA2301253 N 2/KT
MACHALT 538 HINGE PARTS
KIT FOR WATERTIGHT LOW
HINGE TYPE DOOR, PIN: DC
KITMA-538A
017 C SILICONE COMPOUND, 98 6850 008807616 y 1/TU
W/CORROSION INHIBITOR,
SAE-AS8860, aozrru, USING
FOR GASKET
018 C SCREW.CAP, HEXAGON, 9B 5305 0145357 41 N 5/EA
HEAD, 318"-16UNC-2A, 3/4"LG,
CRES 316, NASM35307, PIN:
MS35307-358S316
019 C SCREW,CAP, HEXAGON HEAD, 9B 5305 015604449 N 5JEA
CRES 316, 3/8•·16UNC-2A X
1"LG, NASM35307, PIN:
MS35307-360S316
020 C NUT.PLAIN, HEXAGON HEAD, 9B 5310 013722868 N 5/EA
3/8"-16UNC-2B, CRES 316, MIL-
DTL-1222
021 C WASHER,LOCK, LOCK- 9B 5310 009847042 SX N 1/HD
SPRING, HELICAL, REGULAR
(MEDIUM) SERIES, NOMINAL
SIZE: 3/8", 0.683.OD X 0.388"1D,
NASM35338, PIN: MS35338-
141 CRES
022 C NUT.PLAIN, EXTENDED 9B 5310 016062582 KH N 10fE'I
WASHER, HEXAGON HEAD,
FLANGE NUT, 1/2"-13UNC-2B,
CRES PIN: 94758A033
Ship/HULL NO. Shlo/HULL NAME I ICN: ! Rev: Key Op:
LSD-47 USS RUSHMORE JON: I 38E8161191 ' A01 I
TITLE:
Nonskid Deck Covering on FWD 04 Level Weather Deck; replace