This is a Job Specification document for a Navy ship maintenance project aboard the USS RUSHMORE (LSD-47). The specification details replacement of 490 square feet of chemical-resistant flooring in the ship's laundry (compartment 2-121-1-Q), a wet space area. The flooring system shall comply with MIL-PRF-32584, Type IV or V, and consist of cosmetic polymeric material in dark blue with white flake (American Safety Navy Blue #337 or equal), including underlayment/base coat and three drain rings. Work involves removing existing degraded deck covering down to bare substrate, surface preparation to SSPC-SP-3 using power tools with hand tool cleaning to SSPC-SP-2 for inaccessible areas, installation of slip-resistant self-adhesive treads, and preservation to match surrounding areas per specification 009-032.

The project references standard naval specifications S9086-VG-STM-010/CH-634 (Deck Coverings, General) and includes Government Furnished Material comprising lightweight nonslip deck covering (MIL-PRF-24667), strainer plates for 2-inch type-C deck drains, drain repair kits, and fasteners. The anticipated award date was November 27, 2026, with production completion targeted for March 15, 2027. The period of performance runs from January 25, 2027, through July 31, 2027. The project was prepared by N. Nagato and approved by S. Murakami and S. Morooka, with S. Jones identified as the Project Manager, S320.

View the file

Other files

File Type Posted
2.01 N6264927Q0040.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Youko.Mori.ja Text Box 1301426834

Ship/HULL NO. Ship/HULL NAME I ICN:

LSD-47 USS RUSHMORE JON: I 38E9365501

TITLE:

Chemical-Resistant Flooring in Laundry; replace

1. SCOPE:

1.1 Title: Chemical-Resistant Flooring in Laundry; replace

1.2 Location of Work:

1.2.1 Laundry (2-121-1-Q); Wet Space

1.3 Identification:

Rev: Key Op:

A01

1.3.1 A Total of (490 SF) of Chemical-Resistant Flooring (Cosmetic Polymeric) Including Underlayment/Base Coat, and Drain Ring (3 EA) to be Replaced for Replacing Deck Covering Down to Bare Substrate, Located in 1.2.1

2 . REFERENCES:

Specification: MIL-PRF-32584, Type IV or V Color: Dark Blue with White Flake

2.1

2.2

2 7 Y,/Jlt 1(,~f-•6 Y~h Standard Items (FY2-6-)

S9086-VG-STM-010/CH-634/Rev 4/ACN 1/RS, Deck Coverings, General

3 . REQUIREMENTS:

3.1 Accomplish the requirements of 009-026 of 2.1 including ATTACHMENT C, for replacement of each new chemical-resistant flooring (cosmetic polymeric) system listed in 1.3.1.

3.1.1 Accomplish the requirements of 009-032 of 2.1, including Table 3, Line 4, Column A, for each area, including 6 inches (Maximum Height) up of vertical surfaces.

3.1.1.1 Power tool clean each narrow area to SSPC-SP-3 where

power tool in 3.1.1 cannot reach.

3.1.1.2 Hand tool clean each narrow area to SSPC-SP-2 where

power tool in 3.1.1.1 cannot reach.

3.1.2 Install each new slip-resistant self-adhesive tread to match current location in accordance with 634-3.14 of 2.2.

3.2 Accomplish the requirements of 009-032 of 2.1 for cleaning and preservation of each new and disturbed surface to match surrounding areas.

4. NOTES:

4.1 Initial Condition - Each existing deck covering was degraded and requires replacement.

2/3

Revision

Ship/HULL NO. Ship/HULL NAME ICN: Rev: Key Op:

LSD-47 USS RUSHMORE

JON: 38E9365501 A01

TITLE:

Chemical-Resistant Flooring in Laundry; replace

4.2 The required dark blue of color coat is same as American Safety Navy Blue #337 or equal.

5 .• GOVERNMENT FURNISHED MATERIAL (GEM):

5.1 Government Furnished Material as follows.

MATERIAL LIST

MATERIAL LIST

QTY

Para

ITEM PC REF MIC STOCK HAZ DOC REQD/

No.

NO. NO. NO. DESCRIPTION NUMBER MAT NO. UNIT

DECK COVERING, LIGHTWEIGHT,

NONSLIP, MIL-PRF-24667 TY-XI

001 M COMP-PS, 6'W X 24"L X 0.08"T, 9Q 7220 002050389 N 10/EA 3.1

COARSE HEAVY DUTY GRIT,

BLACK COLOR

STRAINER PLATE, STRAINER FOR 2"

002 C TYPE-C, DECK DRAIN, 803-1385789, 9B 4510 SA4901991 N 2/EA -

MIL-B-16541 4-3/32" OD

003 C

KIT.DRAIN REPAIR PA, REPAIR KIT,

9B 4510 015467725 N 2/KT -2" IPS TYPE-C COPPER ALLOY

STRAINER PLATE, 2-1/2" IPS DECK

004 C DRAIN, 810-1385789 TYPE C, 5-3/32" 9B 4510 N 1/EA -

OD BRONZE

005 C

SCREW,1/, FASTENER, FLAT HEAD,

9B 5305 015453009 N 15/EA -1/4"UNC-2A-2"LG QQ-N-281

Revision