36E77620R0011-003.pdf
PDF Posted
- Attached to
- C1DA--Replace Mechanical Systems, Building 1 Design - Fresno Federal contract opportunity
- Solicitation number
- 36E77620R0011
About this file
This document contains a presolicitation notice for architectural and engineering services for the replacement of mechanical systems at the VA Central California Health Care System in Fresno, California. The scope of work includes replacing two aging air handling units and upgrading systems supporting an inpatient pharmacy. Interested firms must submit Standard Form 330 responses by February 18, 2020 for evaluation. A minimum of three highest rated firms will be invited to interview. The anticipated award date for the engineering design contract is June 30, 2020, with a 395-day period of performance. The project value is $4.1 million. Responses are limited to 40 pages and must include licensing information, past project examples, staff qualifications, and capacity to complete the work on schedule. The solicitation number is 36E77620R0011.
36E77620R0011 Technical Question Tracking Sheet - Fresno Mech Syst.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36E77620R0011-002.docx | DOCX document | |
| 36E77620R0011-004.docx | DOCX document | |
| 36E77620R0011-000.docx | DOCX document | |
| 36E77620R0011-001.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TECHNICAL QUESTIONS
AND RESPONSE TRACKING SHEET
QUESTION RECEIPT
DATE
0BQUESTION ANSWERED
1BDATE 2BCONTRACTOR QUESTIONS 3BVA RESPONSES TO QUESTIONS
1/21/2020 5 FEB 2020 In Section 5-2 it states, “Provide Professional License numbers and/or proof of Licensure”. Will you accept a list of PE License numbers on the SF330 section E Resumes to meet this requirement. If not, will the print out from each state’s licensing website count in the 40-page limit.
Yes, a list of PE License numbers will be accepted. Provide evidence of current full force and effect by expiration date.
1/21/2020 5 FEB 2020 If a CPARS is not available for a project, will a PPQ form be allowed? If a PPQ is allowed, do you have a form you would like us to use, or can we use a previously submitted PPQ?
Yes, a PPQ form will be allowed. A PPQ form is being provided as an attachment. This form must be used for Past Performance if CPARS is not available.
1/21/2020 5 FEB 2020 What Requirements are required for the Low Voltage Designer? Will an RCDD be acceptable as a Professional License for this discipline?
Registered Communications Distribution Designer in coordination and under the oversight of a Professional Electrical Engineer is acceptable.
1/21/2020 5 FEB 2020 Can the HVAC Designer also be the Plumbing Designer?
Yes, the HVAC Designer may also be the Plumbing Designer. Mechanical Engineer licensure required.
2/10/2020 10 FEB 2020 Are CPARs required for all six (6) projects cited for Section F?
Yes, CPARs is required for all projects provided in Section F.
You may provide no more than six (6) relevant projects.
2/10/2020 10 FEB 2020 If CPARs are unavailable, are PPQs acceptable? See above. Yes, the VHA PCAC provided PPQ form will be allowed.
2/10/2020 10 FEB 2020 Will a PPQ template be provided or is it acceptable to use any existing VA template?
See above. VHA PCAC provided PPQ is acceptable.
Replace Mechanical Systems, Building 1 Design (Fresno)
36E77620R0011
PROJECT TITLE
SOLICITATION #
2/10/2020 11 FEB 2020 40 page limit excluding Part IIs, does this also exclude pages for CPARs or PPQs which can be lengthy?
The forty (40) pages are inclusive of CPARs or PPQs.
Please plan accordingly and provide the most relevant information.
2/10/2020 11 FEB 2020 Is the copy of the VetBiz profile also excluded from page count?
The following information is excluded from the forty (40) pages limit:
- Part II
- Cage Code*
- Dun & Bradstreet Number*
- Tax ID Number*
- Email Address & Phone Number of
Primary Point of Contact*
- Copy of VetBiz Registry*
*Important Note: The information required above (excluding Part II) may be provided in either the SF 330 or an accompanying document. If it is not provided in the SF 330, it must be provided in an accompanying document at the time of SF 330 submission. The accompanying document will not be included in the forty (40) page limit.
Part II must be provided in the SF 330 but will not count towards the page limit.
2/10/2020 11 FEB 2020 Are section dividers included in page count?
Usually seven sections for a 330.
Section dividers are not necessary as an SF 330 is broken into sections with clear headers separating the sections. If you should choose to include a whole page to separate the sections, they will be counted toward the forty (40) pages.
2/10/2020 11 FEB 2020 What are the sizes/capacities of the AHU to be replaced?
Boiler plate information regarding both AHU-9 and AHU-10 are not known. Size and unit capacity information will be forwarded once they are ascertained. As presently configured, AHU-9 currently serves the 3rd, 4th, and 5th floors of Building 1(Main Hospital). AHU-10 Currently serves the 6th and 7th floors of Building 1 (Main Hospital).
2/10/2020 11 FEB 2020 Who are the AHU manufacturers? Unkown. Not relevant. AHU’s are exisiting since 1949.
2/10/2020 11 FEB 2020 Are the hot water and chilled water supply already provided?
Yes to the indivual VAV’s.
2/10/2020 11 FEB 2020 Should the approach include testing the water supply to the units?
No.
2/10/2020 11 FEB 2020 Are there backup units to support hospital operation during demolition?
No.
2/10/2020 11 FEB 2020 Should we include allowance for temporary air conditioning during demolition?
Yes.
2/10/2020 11 FEB 2020 Will the VA do any related asbestos and lead testing and abatement?
Yes.
2/10/2020 11 FEB 2020 Will demolition impact existing operations (egress, noise, etc.)?
Yes.
2/10/2020 11 FEB 2020 Are there existing humidification systems? No.
2/10/2020 11 FEB 2020 Are the humidification systems built-in or external?
No.
2/11/2020 11 FEB 2020 How should PPQs be submitted if CPARS is not available?
Section 1 of the attached PPQ form will be completed by the contractor submitting the SF 330.
The contractor submitting the SF 330 will then send the PPQ (Section 1 completed) to the client they wish to provide past performance information.
The client will submit the completed and final PPQ to bailey.donato@va.gov by February 18, 2020 at 2:00 PM ET; the same submission due date and time of the SF 330. *PPQs submitted after this date and time will not be accepted or evaluated.
mailto:bailey.donato@va.gov mailto:bailey.donato@va.gov
The PPQ form provided is three (3) pages. These pages will count toward the forty (40) pages limit.
Please plan accordingly for the number of remaining pages you will have to submit with the SF 330 as the PPQs are submitted by the client to VHA PCAC directly.
2/11/2020 11 FEB 2020 If submissions are over 40 pages, will they be accepted?
SF 330s over forty (40) pages will still be accepted. However, all information included on any of the pages after page 40 will not be evaluated or considered.
Please be aware that all PPQ pages submitted to VHA PCAC from clients are counted toward the forty (40) pages limit.
| CONTRACTOR QUESTIONS |
| VA RESPONSES TO QUESTIONS |
| DATE |
| QUESTION ANSWERED |