Clovis Temp-Sewer Service Dtl-S1.pdf
PDF 2 MB Posted
- Solicitation number
- 36C77622B0059
About this file
This document is an engineering drawing for a temporary sewer service connection to support construction activities at the VA Central California Health Care System in Clovis, California. The drawing specifies the use of schedule 40 PVC pipe and fittings to connect a temporary building's plumbing to the existing sewer main on site. Notes require insulated piping above ground, capping the utility when removed, and including a 4x4 wye cap as a cleanout. The related federal contract opportunity is a solicitation from the Department of Veterans Affairs Technology Acquisition Center Austin for minor construction services to expand parking at the Clovis VAMC under solicitation number 36C77622B0059 as part of project number 570-221.
View the file
Other files
Show 40 more
Latest 50 of 56 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
tel: 570.654.2473 fax: 570.654.6880 www.reillyengineering.com
49 South Main Street Suite 200 Pittston, PA 18640 tel: 570.654.2473 fax: 570.654.6880 www.reillyengineering.com
49 South Main Street Suite 200 Pittston, PA 18640
SEWER SERVICE CONNECTION
Z:
\1
.0 0-
N
EI
C
LO
VI
S
VA
\0
D es ig n\ _C
AD
\0
4- D ra w in gs
\C on st r\R
FI
\C lo vi s Te m p-
W at er S er vi ce D tl.
dw g, 0/
/2
5:
:5
PM
AutoCAD SHX Text NOTES: 1. APPROVED PIPE MATERIALS P.V.C. - A.S.T.M. D3034-T3PSIG SDR-35 2. SELECT PRE-MANUFACTURED ELBOW ANGLE TO MATCH FIELD CONDITIONS. 3. INSULATED PIPE ABOVE GROUND (1" CLOSED CELL) 4. CUT AND CAP UTILITY WHEN REMOVED. 5. PROVIDE 4X4 WYE CAP AS CLEANOUT.
AutoCAD SHX Text
TEMPORARY BUILDING
AutoCAD SHX Text
CONNECT TO BUILDING PLUMBING
AutoCAD SHX Text Date:
AutoCAD SHX Text Scale:
AutoCAD SHX Text Project No.
AutoCAD SHX Text Sheet No.
AutoCAD SHX Text
NTS
AutoCAD SHX Text 10-11-2022
AutoCAD SHX Text 570-221
AutoCAD SHX Text
SK-S1
AutoCAD SHX Text VA CENTRAL CALIFORNIA HEALTH CARE SYSTEM EXPAND MEDICAL CENTER AND PARKING THROUGH LAND PURCHASE 2251 HERDON AVE., CLOVIS CA 93611
AutoCAD SHX Text
2X4 PRESSURE TREATED LUMBER SUPPORT OR EQUAL
AutoCAD SHX Text
3/4" BRACKET (TYP)
AutoCAD SHX Text
SEWER WYE FITTING
AutoCAD SHX Text
SEWER MAIN
AutoCAD SHX Text
AutoCAD SHX Text
4" PVC
AutoCAD SHX Text
NOTE 3
AutoCAD SHX Text
NOTE 5
AutoCAD SHX Text
NOTE 4
jdurkin Line