36C77621R0037_2.docx

DOCX document 17 KB Posted

Attached to
C1DA--612-910 Construct Hematology Oncology and Infusion Center (Minor) Design - Mather VAMC
Solicitation number
36C77621R0037
Issued by

About this file

This document is a modification to a previous notice for a federal contract opportunity. The modification provides additional details for a contract to design a Hematology Oncology and Infusion Center at the Mather Veterans Affairs Medical Center in Sacramento, California. The contracting office is seeking Standard Form 330 qualification packages from interested firms by May 20, 2021 at 2:00 PM Eastern Time for NAICS code 541330. The contract will require experience designing healthcare facilities including at least one project compliant with USP800/797 standards and two oncology/infusion centers. The selected firm should demonstrate the ability to complete 50% of the work using a Service-Disabled Veteran-Owned Small Business and have experience working with VA design guides and specifications.

View the file

Other files

File Type Posted
SF330 Request 36C77621R0037.pdf PDF
SOW Attachment 1 - AE Spec 01 32 16.01.pdf PDF
SOW AE 612-910 Design Mather - Final 2-4-21.pdf PDF
PPQ Mather - Due 5-20-2021.docx DOCX document
SOW Attachment 2 - AE Submission Design Guide.pdf PDF
36C77621R0037.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Contract Opportunity Modification to a Previous Notice

PRODUCT SERVICE CODE

SUBJECT

CONTRACTING OFFICE'S

ZIP-CODE

SOLICITATION NUMBER

BASE NOTICE TYPE

RESPONSE DATE/TIME/ZONE

ARCHIVE

DAYS AFTER THE RESPONSE DATE

RECOVERY ACT FUNDS

SET-ASIDE

NAICS CODE

CONTRACTING OFFICE

ADDRESS

POINT OF CONTACT

(POC Information Automatically Filled from User Profile Unless Entered)

DESCRIPTION

See Attachment

AGENCY'S URL

URL DESCRIPTION

AGENCY CONTACT'S EMAIL

ADDRESS

EMAIL DESCRIPTION

ADDRESS

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

GENERAL INFORMATION

PLACE OF PERFORMANCE

* = Required Field Contract Opportunity Modification to a Previous Notice

C1DA

612-910 Construct Hematology Oncology and Infusion Center (Minor) Design - Mather VAMC 44131 36C77621R0037 05-20-2021

2PM

EASTERN TIME, NEW YORK, USA

N

SDVOSBC

541330 Department of Veterans Affairs Program Contracting Activity Central 6150 Oak Tree Blvd, Suite 300 Independence OH 44131 Contract Specialist Jason Phillip jason.phillip@va.gov VA Northern California Health Care System Sacramento VAMC Mather Campus 10535 Hospital Way Mather

CA

95655-4200

USA

http://www.va.gov/1 Department of Veterans Affairs Homepage1 jason.phillip@va.gov Contract Specialist Q - Do you intend to solicit the commissioning as a separate contract? Or will the commissioning need to be supplied by the prime contractor?

A - Commissioning will be included as part of the prime contractors SOW to require a 3rd party commissioning agent and contracted through the contractor.

We will use the AE and designer of record to peer review and be a member of the commissioning team during CPS.

Q - The solicitation under the “Project Information” identifies the procurement required under NAICS 541310 Architectural Services. Due to the nature of the technical requirements of this project including USP 800/797, the inclusion of the engineering services and the mulit-disciplinary qualifications (8 of the 12 requested positions are non-architectural) identified under Section 5.1. Professional Qualifications we kindly ask for reconsideration of the procurement to be under NAICS Code 541330 and size standard of $16,500,000.

A – The NAICS code for this project is being changed to 541330

Q – Please clarify the following:

0. 1. Offeror shall include at least two examples of USP800/797 design experience – we have completed 4 designs but the first one is still be commissioned. Can we provide letters from the CORs stating they are very happy with the design and CPS support?

0. VA Response: We have reviewed your request and provided updated criteria for Factor 2. See the updated criteria below. Also, a PPQ can be provided in lieu of the CPARS.

0. 2. The A/E shall have completed at least two different oncology/infusion centers – we have some that were included in masterplans but were never built. Would these count?

1. VA Response: It is the discretion of the AE to provide the projects that they have determined to best represent the VA’s evaluation factor criteria.

Factor 1 Revised:

1. Professional Qualifications necessary for satisfactory performance of required service. The design firm and A-E on staff representing the project or signing drawings in each discipline must be licensed to practice in any one of the United States of America, with the exception of the Structural Engineer who must be licensed in CA. Provide Professional License numbers and/or proof of Licensure. The A-E staff representing the project must also have a minimum of five years of experience. The evaluation shall consider the specific experience and qualifications (i.e., education, training, registration, certifications, overall relevant experience, and longevity with the firm as full time employees) of personnel assigned to key positions proposed for assignment to the project, and their record of working together as a team when evaluating the firms professional qualifications. Resumes are limited to one page each.

Key staff members to include are: Project Manager(s), Quality Assurance, Architects, Civil Engineers, Structural Engineers, Electrical Engineers, Mechanical Engineers, Environmental Engineers, Fire Protection Engineers, Environmental Engineers, Interior Designers, Certified Independent Third-Party (CITP) consultant and any other pertinent positions related to the scope of work. The lead key personnel in each discipline must be a registered professional but does not have to be registered in the particular state where the project is located, with the exception of the Structural Engineer who must be registered in CA.

Offer must include the following statement of SDVOSB compliance when submitting the personnel proposed to perform the work under this requirement: “I [signatory authority]___________________, [company] __________________ certify that the team proposed to perform under this requirements demonstrates the capability of 50% SDVOSB performance in compliance of 48 CFR 852.219-10.”

The information provided in sections C through E of SF 330 will be used to evaluate this evaluation factor. Do not include this information in section H, unless it is pertinent to support the information listed in the other sections.

Factor 2 Revised:

1. Specialized Experience and Technical Competence in the type of work required: Specialized experience and technical competence in the design, construction, and construction period services provided for Hematology /Oncology Infusion Centers. Provide specialized experience examples in healthcare planning and delivery. Any provided past performance information on projects should include relevant work with Hospitals, Civil, Architectural, Mechanical, Structural, Electrical, and physical security upgrades/installation. Include no more than six (6) Government and/or private projects that demonstrate relevant experience with project that are similar in size, scope and complexity, and experience with specialized building types requiring physical security measures. The A/E shall have completed at least one USP800/797 project and shall have completed at least two (2) different oncology / infusion centers and have the capacity and experience to design this type of healthcare facility. The evaluation will consider the management approach, coordination of disciplines and subcontractors, quality control procedures, prior experience of the prime firm and any key subcontractors working together on relevant projects and familiarity with VA Design Guides/Manuals, Master Specifications and other applicable standards. A higher rating may be considered for the firms that have more experience with USP800/797 and oncology/infusion center projects. Note that completed is considered 100% design completion and substantially completed in construction.

The information provided in sections F and G of SF 330 will be used to rate this evaluation factor. Do not include this information in section H, unless it is pertinent to support the information listed in the other sections.

End of Document

File details come from the government source that posted it. Updated .