This is a Sources Sought Notice issued by the Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 23 (Central Iowa Health Care System) seeking market research information on spirometers for potential future procurement. The solicitation number is 36C26326Q0918, with responses due by 4:00 PM Central Time on July 20, 2026. This notice explicitly states that no proposals are being requested, no pricing information is sought, and no contract will be awarded from this notice. Responses will be used solely for government market research and acquisition strategy development, including evaluation for potential set-asides for Veteran-Owned and other socioeconomic small business categories.

The requirement is for one compact, desktop Pulmonary Function Test (PFT) spirometer suitable for transportation by a PFT therapist via automobile, weighing between 10 and 25 pounds with dimensions between 20" H x 18.5" D x 12" W and 24" H x 20" D x 15" W. The equipment must provide spirometry testing (FEV1, FVC, SVC, MVV minimum), lung volume measurements (TLC, FRC, RV) without plethysmography, and DLCO single-breath diffusing capacity measurements. Technical specifications include a flow sensor with 0-18 L/s range and 2.5% accuracy, a multi-gas analyzer (CO2/CH4 or equivalent) with response time not exceeding one minute, and automated calibration/zeroing capabilities. The Buy American Act applies; vendors must indicate place of manufacture. The NAICS code is 339112 (Surgical and Medical Instrument Manufacturing) with an SBA small business size standard of 1,000 employees.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
Spirometers

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
52241
SOLICITATION NUMBER*
36C26326Q0918
RESPONSE DATE/TIME/ZONE
07-20-2026 4:00 PM CENTRAL TIME, CHICAGO, USA
ARCHIVE
30 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
SET-ASIDE
SBA
PRODUCT SERVICE CODE*
6515
NAICS CODE*
339112
CONTRACTING OFFICE ADDRESS
DEPARTMENT OF VETERANS AFFAIRS

NETWORK CONTRACTING OFFICE 23

1303 5TH STREET, SUITE 300

CORALVILLE IA 52241

POINT OF CONTACT*

Contracting Specialist Jennifer Watkins-Schoenig jennifer.watkins-schoenig@va.gov 319-688-3631

PLACE OF PERFORMANCE

ADDRESS

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

The Central Iowa Health Care System requires the purchase of one spirometer with the salient characteristics listed below.

This is a SOURCES SOUGHT NOTICE only looking for American manufactured equipment as listed below for market research purposes. No proposals are being requested or accepted with this notice. THIS IS NOT A SOLICITATION FOR PROPOSALS OR PRICING AND NO CONTRACT SHALL BE AWARDED FROM THIS NOTICE. This notice shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs.

The Buy American Act, FAR 52.225-1, applies. Interested vendors shall include the place of manufacture in their responses.

Responses to this notice will be treated only as information for the Government to consider as part of their market research efforts. The information provided will be used by the Government in developing its acquisition strategy regarding possible set aside for Veteran Owned and other socio-economic categories of small business. Interested parties are responsible for adequately marking proprietary, restricted or competition sensitive information contained in their response. The Government does not intend to pay for the information submitted in response to this notice and parties responding will not be entitled to payment for direct or indirect costs incurred in responding to this notice.

The North American Industry Classification System (NAICS) code for this requirement is 339112 Surgical and Medical Instrument Manufacturing with an SBA Small Business Size Standard of 1,000 employees.

The deadline for this information is 4:00 PM Central Time on Monday, July 20th 2026.

· Be a compact, desktop PFT suitable for loading & transportation by PFT Therapist via automobile. Weight range 10 lb. to 25 lb. and measuring between 20” H x 18.5” D x 12” W and 24″ H × 20″ D × 15″ W.

· Provide spirometry testing (FEV₁, FVC, SVC, MVV, at a minimum).

· Provide lung volume measurements (TLC, FRC, RV) without use of plethysmography box.

· Provide DLCO single-breath diffusing capacity measurements including DLCO, VA, and DLCO/VA.

· Use a flow sensor with 0–18 L/s range, ±2.5% accuracy or ±0.05 L/s.

· Include a multi-gas analyzer (CO₂/CH₄ or equivalent) with response time no greater than 1 minute.

· Automated calibration/zeroing, warm-up <10 minutes. Calibration done per American Thoracic Society 3 -Liter syringe. Operating temperature range 65 F to 75 F.

· Use an FDA-cleared bacterial/viral filter with ≥99.99% cross-contamination prevention.

· Operate on universal medical-grade power (100–240 VAC, 50–60 Hz).

· Include a touchscreen interface (screen measuring between 8-12″ HD).

· Provide data export in standard formats, generate user‑defined reports, and enable integration with electronic health record systems through HL7‑compliant interfaces standard formats, generate user‑defined reports, and enable integration with electronic health record systems through HL7‑compliant interfaces (PDF, CSV, JSON, etc.)

· Be compliant with ATS/ERS standards for spirometry, lung volumes, and DLCO.

· Hold applicable FDA clearance for clinical diagnostic use and comply with applicable IEC 60601 and NFPA 99 electrical safety requirements.

Required accessories included with the system:

· Carry Case

· DLCO Gas Regulators

· HL7 Configuration (1 device)

· 3-Liter Calibration Syringe Unit Requirements

· Certified for inpatient & outpatient hospital use

· Exterior surfaces compatible with VA-approved hospital-grade disinfectants (e.g., Super Sani-Cloth, PDI bleach wipes, or equivalent)

· 1 year manufacturer's warranty included in price (parts and labor); warranty period begins on date of Government acceptance

· Manufacturer technical support (telephone and/or remote diagnostic) included for the full warranty period

· Operates on standard hospital AC power (100–240 VAC) with a medical-grade power supply

· Delivery, installation, and on-site operator training by a qualified manufacturer representative or certified technician included in price

· Operations manuals & IFU Cleaning instruction provided by manufacturer

· Offerors must provide documentation demonstrating compliance with all listed standards