About this file

This is a Sources Sought Notice issued by the Department of Veterans Affairs Network Contracting Office for the Sioux Falls VA Medical Center Research Department. The solicitation number is 36C26326Q0381, with responses due by February 27, 2026 at 11:00 AM Central Time. This is a market research announcement seeking information from vendors capable of providing Noldus EthoVision and UtraVox XT equipment and related services; no contract awards will be made from this announcement.

The Sioux Falls Health Care System requires a comprehensive animal behavioral research system for biosafety level 2 laboratory work, including: one UtraVox XT system with four microphones and Windows 11 Pro operating system on Dell Precision workstations, two deep learning desktop workstations, two mouse-sized light dark chambers, four mouse phenotypers, four mouse-sized fear conditioning setups, two software licenses with specified modules, onsite integration and installation training, delivery and freight, and a three-year NoldusCare maintenance warranty. The equipment must be delivered and installed by July 2026 (tentative) to a ground-level research building at 2501 West 22nd Street, Sioux Falls, South Dakota 57105, with installation scheduled during standard business hours (8:00 AM to 4:30 PM, Monday through Friday). Respondents must submit capability information and answers to seven questions addressing socio-economic status, manufacturer status or authorized distributor authorization, country of origin certification, availability on existing government contracts, small business requirements compliance, subcontracting plans, and estimated delivery lead times to Michael Wicht at michael.wicht@va.gov. The Product Service Code is 5836 and NAICS Code is 334516.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
Noldus EthoVision and UtraVox XT for Sioux Falls VA Research Dept.

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
68102
SOLICITATION NUMBER*
36C26326Q0381
RESPONSE DATE/TIME/ZONE
02-27-2026 11:00 CENTRAL TIME, CHICAGO, USA
ARCHIVE
30 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
5836
NAICS CODE*
334516
CONTRACTING OFFICE ADDRESS
DEPARTMENT OF VETERANS AFFAIRS

NETWORK CONTRACTING OFFICE 23

111 SOUTH 18TH PLAZA, SUITE C125

Omaha NE 68102

POINT OF CONTACT*

Contract Specialist Michael Wicht michael.wicht@va.gov 402 996-3630

PLACE OF PERFORMANCE

ADDRESS
Sioux Falls VA Medical Center

Sioux Falls SD

POSTAL CODE
57105
COUNTRY
USA

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS Michael.wicht@va.gov

EMAIL DESCRIPTION Contracting Specialist Email Address

DESCRIPTION

The Sioux Falls Health Care System requires Noldus EthoVision and UtraVox XT and accessories with the Salient Characteristics listed below.

This is a sources-sought looking for businesses to provide the supplies listed below for market research purposes. No awards for a contract will be made from this announcement.

If you are a vendor that can provide the requested information above and required supplies described below with competitive pricing, send your information (to include your organization's Unique Entity Identifier number) with a description of proof of capability to: Michael.Wicht@va.gov on or before February 27, 2026. Only emailed responses will be considered.

Additionally, please provide answers as appropriate to the following questions in the table below with your response to this sources-sought. Failure to respond to the following questions may affect the acquisition strategy.

1.
Identify your organization's socio-economic category.
2.
Identify if your organization is the manufacturer of the requested supplies. If you are not the manufacturer, identify the manufacturer of the supplies that you will provide, their socio-economic category and a letter showing that your organization is an authorized distributor for the requested supplies.
3.
Fill out the certificate under FAR Provision 52.225-2(b), identifying the item and its country of origin. ( https://www.acquisition.gov/far/part-52#FAR_52_225_2__d3401e52). If the product is a US domestic end product, write in USA for the item's country of origin.
4.
State whether any of the requested supplies may be ordered against a government contract awarded to your organization (e.g Federal Supply Schedule (FSS), General Services Administration (GSA), etc.).
5.
Address whether your organization meets the requirements of 13 CFR 121.406 (b)(1)(i), (b)(1)(ii) and (b)(1)(iii) (https://www.ecfr.gov/current/title-13/chapter-I/part-121/subpart-A/subject-group-ECFR0fca5207262de47/section-121.406#p-121.406(b)).
6.
State if subcontracting is contemplated for this requirement and what percentage of the requirement will be subcontracted and for what tasks.
7.
Provide estimated shipping and delivery information for the requested supplies (e.g. Expected lead time on delivery).

*If applicable, VAAR 852.219-76 VA Notice of Limitations on Subcontracting—Certificate of Compliance for Supplies and Products, will apply to the potential solicitation if set-aside for Veteran Owned Small-Businesses. * *If applicable, VAAR 852.212-71 Gray Market Items, will apply to the potential solicitation.* *If applicable, FAR 52.219-14 Limitations on Subcontracting, will apply to the potential solicitation if set-aside for Small-Businesses. * Identify whether any foreign end products, as defined in FAR Provision 52.225-2, would be provided to meet this requirement ( https://www.acquisition.gov/far/part-52#FAR_52_225_2__d3401e52).

Sioux Falls Health Care System 2501 W 22nd Street Sioux Falls, SD 57105 Project: SF Research Activation - Ethovision

STATEMENT OF WORK - Functional/Performance/Specification (Brand Name or Equal)

1.0 General Scope

This requirement includes research into animal behavioral equipment and warranty services as required for biosafety level (BSL) 2 labs. Sioux Falls VA Health Care System requires the following Brand Name or Equal items: The contractor shall provide all materials, equipment, assembly instructions, and delivery to Sioux Falls VA.

2.0 Performance Requirements

The contractor shall provide and be responsible for the technical assistance, development, and generation for final specifications.

Installation and delivery to the Research building, a one level building located on the Sioux Falls VA Health Care System campus at 2501 West 22nd Street, Sioux Falls, SD 57105. Ground level unloading is required. Installation window to be arranged during the activation timeframe with a tentative installation date of July 2026. VA will provide a schedule update at the time of award. At least ten-day notice prior to installation is required.

Duty hours will be 8am to 430pm, Monday thru Friday excluding holidays. The Government recognized US holidays are: New Year’s Day, Martin Luther King, Jr. Day, Presidents Day, Memorial Day, Juneteenth, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving Day and Christmas Day. If the holiday falls on Sunday, it is observed on Monday.

3.0 PRODUCT (Functional/Performance/Specification (Brand Name or Equal)) This requirement includes meeting Brand Source or equivalent to the Noldus UtraVox XT System. The system includes UltraVox XT with 4 microphones, 2x deep learning workstations, 2x mouse-sized light dark chambers, 4s mouse phenotypers, 4x mouse-sized fear conditioning setups, 3 year NoldusCare maintenance plan, and onsite installation and training. The system will allow staff to track and analyze movement, activity and behavior of mice. The equipment would be used to study stress-induced disorders such as PTSD and addiction. System is an all-in-one system that allows researchers to conduct the following animal behavior applications: learning and memory; fear, anxiety, and stress; long term behavior observations, social tests, brain imaging and optogenetics, zoology and ethology, gait analysis, and ultrasonic vocalizations.

Sioux Falls VA Health Care System requires the following:

A. QTY 1: Software License EV160-01298-AANEIAAA and adding Social Interaction Module

B. QTY 1: Software License EV160-05746-AAFEIAAA and adding Multiple Arena & Social Interaction Module

C. QTY 1: UltraVox XT system with 4 microphones

· Operating system must be Windows 11 Pro (64-bit) 23H2 or 24H2

· Desktop requirements must be Dell Precision 3680 or higher; Laptop: Dell 3591 Mobile

· Laptop must provide USB 3.0 hub and support D-link 4-port DUB-1340, bit rate 5 Gpbs

· Memory must be at least 16GB of Internal memory (RAM)

· Hard drive must be at least 500GB Solid State drive (for data collection)

· Hard disk must be at least 1 TB free space (to store experiments)

· Microphones must provide 4 Pettersson M500-384

· Maximum recording duration must be at least 90 min D. QTY 2: Desktop Workstations compatible with Deep Learning E. QTY 2: Mouse-Sized Light Dark Chambers - 17.5cm x 40cm dark chamber; 25cm x 40 cm light chamber; 5cm door F. QTY 4: Mouse PhenoTypers G. QTY 4: Mouse-Sized Fear Conditioning Setups H. QTY 1: Onsite Integration, Installation, and Training I. QTY 1: Estimated Delivery Fee – Freight J. QTY 1: Warrantee: NoldusCare 3 years

7.0 SERVICES

Service required includes delivery of the research equipment to the research building at Sioux Falls VA Medical Center 2501 W 22nd St Sioux Falls SD, 57105, 90-120 days after award, in coordination with the COR prior to delivery.

Warranty Information – 3 Year Warranty or Manufacturer’s Warranty – Whichever is greater.

*= Required Field
Sources Sought Notice

Sources Sought Notice

File details come from the government source that posted it. Updated .