This sources sought notice requests information for the potential acquisition of a PerkinElmer PinAAcle 500 Flame Atomic Absorption Spectrometer or equal. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 23 seeks this equipment to replace an outdated 15-year old model. Responses are due by September 20, 2023 at 10:00 AM Central Time.
The notice provides details on the salient characteristics and justification for the PinAAcle 500, including its robust and affordable design, corrosion resistance, compact footprint, intuitive touchscreen software, low maintenance costs, and compatibility with existing lamps and ventilation system. Acquisition of this model would allow for a smoother transition than other vendors' instruments due to similarities to the current equipment.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice Sources Sought Notice
| SUBJECT* |
| RFI Sources Sought Flame Atomic Absorption Spectrometer 36C26323Q1191 PinAAcle 500 Analyzer - Perkin Elmer (or EQUAL) |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 52241 |
| SOLICITATION NUMBER* |
| 36C26323Q1191 |
| RESPONSE DATE/TIME/ZONE |
| 09-20-2023 10:00 AM CENTRAL TIME, CHICAGO, USA |
| ARCHIVE |
| 14 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
| SET-ASIDE |
| SDVOSBC |
| PRODUCT SERVICE CODE* |
| 6640 |
| NAICS CODE* |
| 339112 |
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs
NETWORK 23 CONTRACTING OFFICE
1303 5th St, Suite 300 Coralville IA 52241
POINT OF CONTACT*
Contract Specialist Jennifer Buck
PLACE OF PERFORMANCE
| ADDRESS |
| 4101 Woolworth Avenue |
Omaha NE
| POSTAL CODE |
| 68105 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
| AGENCY CONTACT’S EMAIL ADDRESS |
| Jennifer.Buck2@va.gov |
EMAIL DESCRIPTION
DESCRIPTION
Salient characteristics Flame Atomic Absorption Spectrometer
Justification for acquisition of the Perkin Elmer for the PinAAcle 500.
Overview:
The Perkin-Elmer PinAAcle 500 is a 4-lamp position flame model is very similar to the 15-year-old Perkin-Elmer AAS that is currently used by the PI and his team. The new Perkin-Elmer PinAAcle 500 instrument is built to deliver an unparalleled level of performance at an affordable price and offers superior durability, longer life, and lower maintenance costs. Basically, it is a workhorse that offers flexibility, reliability, at a very affordable price.
Logistics and Details:
· Robust and affordable Flame AA with solid-state detection system
· Corrosion-resistant design
· Conformal-coated circuit boards to extend instrument life
· Compact footprint 26”wide x 25” high
· Intuitive color touchscreen with interchangeable mount
· Syngistix Touch Software to save and share methods and results
· Spectrometer Type – Atomic Absorption
· Peltier Detector – Standard
· Compatible with 21 CFR Part 11
· Excellent signal-to-noise ratio
· Low Maintenance cost
· Precision of less than0.3%
· Fully contained, maintenance-fee fiber optic technology
· Accurately measures the most difficult elements
· Upgradable on-board computer
· We recently upgraded the ventilation system in our laboratory in the DRCII building housing the device. This required extensive modification of the ventilation system designated for the AAS. The physical footprint of the PinAAcle is essentially identical to our current instrument so no further adjustments and cost would be required.
· The lamps that we already have (to measure zinc, cadmium, and manganese) are compatible with the new instrument so we would not need to purchase new lamps, which would not be possible if purchased through another vendor.
· Less maintenance will be required compared to our current instrument because the sample induction module can be removed compared to the old AAS that requires removal of 4 individual sections which is much more a complicated and time consuming.
· While many aspects of the new 500 are different, the software, operation and maintenance are similar to our outdated instrument thus allowing a smoother transition with very little training required.