AutoCAD SHX Text

DN

AutoCAD SHX Text B8

AutoCAD SHX Text B7

AutoCAD SHX Text B1B

AutoCAD SHX Text B2

AutoCAD SHX Text B5

AutoCAD SHX Text B4B

AutoCAD SHX Text B3A

AutoCAD SHX Text B4A

AutoCAD SHX Text B4D

AutoCAD SHX Text B3B

AutoCAD SHX Text B3G

AutoCAD SHX Text B8

AutoCAD SHX Text B6

AutoCAD SHX Text B3E

AutoCAD SHX Text B3D

AutoCAD SHX Text B3C

AutoCAD SHX Text B3F

AutoCAD SHX Text B4C

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

VENDING

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

STOR.

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

CARE IN THE

AutoCAD SHX Text

COMMUNITY

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

TOILET

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

LOCKER

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

FEMALE

AutoCAD SHX Text

LOCKER

AutoCAD SHX Text

AREA

AutoCAD SHX Text B4

AutoCAD SHX Text B3H

AutoCAD SHX Text B3I

AutoCAD SHX Text

HAC

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text T

AutoCAD SHX Text

NOTES

AutoCAD SHX Text

1. New mini split outdoor condenser. Drill through and

AutoCAD SHX Text 1.

AutoCAD SHX Text and repair sandstone as needed for refrigerant

AutoCAD SHX Text Unit shall be Mitsubishi Multi-Split Hyper-

AutoCAD SHX Text

2. New wall mounted cassette evaporator.

AutoCAD SHX Text 5.

AutoCAD SHX Text

3. New wireless thermostat.

AutoCAD SHX Text 3.

AutoCAD SHX Text T

AutoCAD SHX Text 2.

AutoCAD SHX Text

BASEMENT FLOOR BLDG. #2

AutoCAD SHX Text N

AutoCAD SHX Text 1/8" = 1'

AutoCAD SHX Text Heat OB/ST MXZ-8C48NAHZ or approved equal.

AutoCAD SHX Text Mitsubishi MSZ-GL06NA-U1 or approved equal.

AutoCAD SHX Text T

AutoCAD SHX Text

4. New wall mounted cassette evaporator.

AutoCAD SHX Text Mitsubishi MSZ-GL09NA-U1 or approved equal.

AutoCAD SHX Text 4.

AutoCAD SHX Text

5. New wall mounted cassette evaporator.

AutoCAD SHX Text Mitsubishi MSZ-GL12NA-U1 or approved equal.

AutoCAD SHX Text piping. H2i hyper-heating outdoor condenser for

AutoCAD SHX Text multi-zone heating and cooling system. 48,000 BTU, AutoCAD SHX Text R-410A Refrigerant, minimum outdoor temperature

AutoCAD SHX Text for cooling 23 degrees F. 208/230V, single phase, AutoCAD SHX Text 42A, ETL listed.

AutoCAD SHX Text R-410A refrigerant type, wireless remote control, AutoCAD SHX Text 9,000 BTU, minimum air flow 145 CFM, maximum air flow

AutoCAD SHX Text

399 CFM.

AutoCAD SHX Text R-410A refrigerant type, wireless remote control, AutoCAD SHX Text 6000 BTU, minimum air flow 145 CFM, maximum air flow

AutoCAD SHX Text

399 CFM..

AutoCAD SHX Text 12,000 BTU, minimum air flow 145 CFM, maximum air flow

AutoCAD SHX Text

399 CFM.

Sheets and Views