FedBizOpps Presolicitation Notice
CLASSIFICATION CODE
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
RESPONSE DATE (MM-DD-YYYY)
ARCHIVE
DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
SET-ASIDE
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION
See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
GENERAL INFORMATION
PLACE OF PERFORMANCE
* = Required Field FedBizOpps Presolicitation Notice Rev. March 2010 J Steris Sterilizer Maintenance - NWI Base Year: 02/01/2019 to 01/31/2020 +4 57105 36C26319Q0199 01-04-2019 N 811219 Department of Veterans Affairs
NETWORK 23 CONTRACTING OFFICE
2501 W. 22nd St.
Sioux Falls SD 57105 Curt R LaRose Contract Specialist
605.336.3230 x7573 Curt.LaRose@va.gov Curt.LaRose@va.gov
STERILIZER MAINTENANCE SERVICES
This is a sources sought notice only and it is not a solicitation announcement. The purpose of this sources sought notice is to gain knowledge of qualified potential contractors and their socio-economic size classification in accordance with NAICS code 811219 Other Electronic and Precision Equipment Repair and Maintenance. Responses will be used by the Government to make appropriate acquisition decisions. After a review of the responses to this sources sought notice, a solicitation announcement may be posted. A response to this sources sought notice is not an adequate reply to a potentially forthcoming solicitation.
The Nebraska Western-Iowa (NWI) VA Health Care System located in Omaha, Nebraska is seeking qualified potential contractors to provide Sterilizer Maintenance Services. Refer to the attached document titled “Sterilizer Service NWI VA Health Care System” for additional details and information.
To respond to this sources sought notice, please complete the attached form titled “Response Form to Sources Sought Notice” and email the information requested to Curt LaRose, Contracting Specialist, at curt.larose@va.gov. The closing date and time of this sources sought notice is December 21, 2018 at 8:00 AM Central Time.
This is not a solicitation and in no way obligates the Government to award any contract. Additionally, a response to this sources sought notice is not a request to be added to a prospective bidders list or to receive a copy of any forthcoming solicitation.
Sources Sought Information and Capabilities for Sterilizer Maintenance Services VANWIHCS
Please fully complete each section of the form below.
Company Name: _____________________________________________________________ Company Address: ___________________________________________________________ DUNS Number: _____________________________________________________________ Point of Contact: ____________________________________________________________ Phone Number: _____________________________________________________________ Email Address: _____________________________________________________________
Socio-economic Classification in Accordance with NAICS Code 811219 Other Electronic and Precision Equipment Repair and Maintenance (check all that apply) ☐ Small Business ☐ Service Disabled Veteran Owned Small Business (SDVOSB) ☐ Verified SDVOSB by www.vip.vetbiz.gov ☐ Veteran Owned Small Business (VOSB) ☐ Verified VOSB by www.vip.vetbiz.gov ☐ Small Disadvantage Business ☐ Women-owned Small Business ☐ Economically Disadvantaged Small Business ☐ HUBZone ☐ 8(a) Certified ☐ Other: _________________________________________________
Detailed Information:
1. Please describe your company’s ability to meet the requirements as listed in the Statement of Work.
2. What percentage of the contracted services can your company complete as the prime contractor? ______________%
3. What percentage of the contracted services would your company subcontract? ______________%
4. Please attach your Company’s Capability Statement for Sterilizer Maintenance Services.
DESCRIPTION/SPECIFICATIONS/WORK STATEMENT
636-19-2-2301-0067
1. Scope of Work:
1.1. The contractor will furnish all labor, transportation, parts, test equipment, tools, and expertise necessary to implement a Full Service agreement on the STERIS equipment listed in para 2.1 below. Equipment is located at the Omaha VA Medical Center and the Grand Island VA Medical Center. Service agreement must include any regular scheduled maintenance inspections to include parts replacement as described in the original manufacturer’s service manual for the model listed. Base Coverage period from 1 Feb 2019-31 Jan 2020, 8am-5pm for SPD/Infection Prevention equipment and 8am-8pm for Surgical/OR equipment. The contractor shall quote for multi-year coverage.
1.2. Work includes, but is not limited to, periodically performing preventive maintenance, thoroughly inspecting and testing the STERIS equipment, making adjustments to, effecting repairs and replacing parts and keeping existing system software current with manufacturer’s recommendations. The vendor shall perform calibration of all sterilizers as required in the OEM service manual for each unit, but not less than 1 year. Coverage should be equal or better than that offered by the commercially available “Comprehensive (Platinum)” with calibration option service plan offered by STERIS. This contract is effective for 1 year upon date of award plus 4 one-year options that may be exercised by the VA.
1.3. The medical equipment covered by this contract does not contain electronic patient health information (EPHI).
1.4. Normal service requirements under this contract consist of scheduled preventive maintenance inspections, adjustments and repairs, as specified herein, along with scheduled contractor maintenance in response to service calls made by VA Omaha and Grand Island Biomedical Engineering Department to the contractor due to a partial or complete system or subsystem failure which requires the contractor to respond within a specified time frame to make needed repairs/adjustments to the system.
2. Equipment:
2.1. The equipment to be serviced/maintained includes:
| Description |
| Model |
| Serial# |
| location |
| STERILIZING UNITS: GASEOUS PLASMA, AMSCO V-PRO MAX |
| AMSCO V-PRO MAX |
| 33311210 |
| 4374-1-OM |
| STERILIZING UNITS: GASEOUS PLASMA, AMSCO V-PRO MAX |
| AMSCO V-PRO MAX |
| 31791312 |
| SE1-001-GI |
| STERILIZING UNITS: GASEOUS PLASMA, AMSCO V-PRO MAX |
| AMSCO V-PRO MAX |
| 30581302 |
| 4374-1-OM |
| STERIS WASHER/DISINFECTOR W/STEAM HEAT |
| RELIANCE GENFORE |
| 33311210 |
| 4370-1-OM |
| WASHERS: LAB/SURGICAL INSTRUMENT: ULTRASONIC |
| INNOWAVE PCF |
| 08178478312 |
| 4370-1-OM |
3. Definitions/Acronyms:
3.1. NWIHCS - Nebraska Western Iowa Health Care System. Consists of 3 main campuses: Omaha 4101 Woolworth Ave, Omaha NE 68105 (ph 402.995.3040); Grand Island 2201 N Broadwell Ave, Grand Island NE 68803 (308-382-3660 ext 2491); and Lincoln 600 South 70th, Lincoln NE 68510 (ph 402.489.3802 ext 6437)
3.2. CO – Contracting Officer.
3.3. COR – Contracting Officer’s Representative.
3.4. IAW – In Accordance With
3.5. PM – Preventive Maintenance Inspection. Services which are periodic in nature and are required to maintain the equipment in such condition that it may be operated in accordance with its intended design and functional capacity with minimal incidence of malfunction or inoperative conditions.
3.6. FSE – Field Service Engineer. A person who is authorized by the contractor
3.7. FSR – Field Service Report. A documentation of the services rendered for each incidence of work performance under the terms and conditions of the contract.
3.8. Acceptance Signature – Signature of VA Omaha employee who indicates FSE demonstrated service conclusion/status and user has accepted work as complete/pending as stated in ESR.
3.9. Authorization Signature – COR’s signature; indicates COR accepts work status as stated in ESR.
3.10. OSHA – Occupational Safety and Health Administration.
3.11. First Look / CO-OP – type of service contract coverage were the VA BESS attempts to solve minor problems or makes easily completed repairs with parts provided by the vendor. May also include the VA BESS accomplishing scheduled maintenance (PM) instead of the vendor performing it. This type of coverage normally results in a cost savings to the government.
3.12. BESS — Biomedical Equipment Support Specialist. VA employee responsible vendor coordination of maintenance for VA owned medical equipment.
4. Conformance Standards:
4.1. Contract service shall ensure that the equipment/system functions in conformance with the latest published edition of NFPA-99, OSHA, manufacturer’s Network Equipment/System upgrades/updates shall be installed in strict accordance with manufacturer’s specifications and must operate within manufacturer’s specifications and must operate within manufacturer’s specified parameters.
5. Hours of Coverage:
5.1. The contractor will respond by phone at no additional charge, within the normal business hours (8:00 AM to 8:00 PM for Surgical (OR) equipment and 8:AM-5:00 PM for Infection Prevention (SPD) equipment (CST) M-F).
5.2. All scheduled service/repairs shall be performed during these normal hours of coverage unless one of the following conditions exist:
5.2.1 The contractor wishes to perform such maintenance at a time that is outside of the normal hours of coverage, at no additional cost to the Government, and the contractor submits a request to the COR prior to the proposed start of the maintenance and the request is approved by the COR before work is begun.
5.2.1.1 The COR directs that the scheduled maintenance be performed at a time that is outside the normal hours of coverage and the additional cost is recommended by the COR and authorized by the CO.
5.3. Scheduled maintenance shall be performed in accordance at the manufacturer’s recommended intervals and should be scheduled/completed during the month the VA requests. Changes in this periodicity will occur only when approval is granted by the COR and CO.
5.4. Scheduling for unscheduled maintenance requirements outside of normal hours shall be coordinated with and require the approval of the COR.
5.6. Federal holidays observed by VA Omaha are:
| New Years Day | Labor Day | ||
| Martin Luther King Day | Columbus Day | ||
| President’s Day | Veteran’s Day | ||
| Memorial Day | Thanksgiving Day | ||
| Independence Day | Christmas Day |
and any other day specifically designated by the President of the United States.
6. Unscheduled Maintenance:
6.1. Contractor shall maintain the equipment in accordance with original equipment manufacturer’s specifications.
6.2. The contractor shall provide repair service, which may consist of calibration, cleaning, oiling, adjusting, replacing parts, and installing parts.
6.3. All parts will be covered in this agreement.
6.4. The Contracting Officer, COR and designated Alternate have the authority to approve/request a service call from the contractor.
6.5. Response time:
6.5.1. Contractor’s FSE shall respond by phone during normal business hours within (4) hours and be on-site within 48 hours of initial contact by the VA.
6.5.2. If the problem cannot be corrected by phone or by remote diagnostics the contractor will dispatch a technician to arrive not later than the next business day after the call is placed.
7. Scheduled Maintenance:
7.1. Contractor shall perform PM service to ensure that equipment listed in the schedule performs in accordance with the manufacturers recommendations as published in the Manufacturer’s Maintenance Manuals for the system.
7.2. Contractor shall provide and utilize procedures and checklists with worksheet originals indicating work performed and actual values obtained (as applicable) provided to the COR at the completion of the PM.
7.3. PM services shall include, but need not be limited to, the following:
7.3.1. Cleaning of equipment to include filters, gearing, and other parts.
7.3.2. Reviewing operating system software diagnostics to ensure that the system is operating as specified by the manufacturer’s specifications.
7.3.3. Calibrating and lubricating the equipment.
7.3.4. Performing remedial maintenance of non-emergent nature.
7.3.5. Performing electrical safety inspection IAW NFPA 99.
8. Parts:
8.1 The Contractor will provide all replacement parts needed to keep the system in operating condition as originally designed by the manufacturer.
8.2 Parts may be repaired or replaced, as the contractor deems appropriate. No used parts will be used to repair this equipment.
9. Service Manuals:
9.1. VA will not provide service manuals of service diagnostic software to the contractor. The contractor shall obtain, have on file, and make available to its FSEs all operational and technical documentation, (such as: operational and service manuals, schematics, and parts list), which are necessary the meet the performance requirements of this contract.
9.2. The location and listing of the service data manuals, by name, and/or the manuals themselves shall be provided to the Contracting Officer upon request.
10. Documentation/Reports:
10.1. Documentation shall include detailed descriptions of the scheduled and unscheduled maintenance procedures performed, including replaced parts and prices required to maintain the equipment in accordance with manufacturer specifications.
10.2. Any additional charges claimed will be approved by the CO via the COR before service is completed.
11. Reporting Requirements:
11.1. Upon arrival at VA Omaha the contractor shall be required to log in with Biomed in room B556 in Omaha, and room C09 in Grand Island. This log in is mandatory as well as wearing the contractor badge issued upon log in. Contractor’s FSE(s) shall wear visible identification at all times while on the premises of the VA. Identification shall include, as a minimum, the employee’s name, position, and the contractor’s trade name. In addition, the contractor shall submit fingerprints through the VA police for issuance of a VA identification badge that shall be worn at all time while working at a VA facility.
11.2. When service is completed, the FSE shall document services rendered on a legible ESR(s) and submit to the BESS who set-up the service. The ESR can be submitted when logging out with Biomed, via an internet web site or e-mail. ESRs should be submitted not later than 5 business days after service is complete. Preferred method of delivery is via email to NWIHCSBiomedicalStaff@va.gov
11.3. In those cases when the Biomed office is closed, contractor personnel will log in and/or out via the VA police and after hours service shall be prearranged with the BESS.
12. Services Beyond the Contract Scope:
12.1. Contractor shall immediately, but not later than 24 consecutive hours after discovery, notify the CO and COR, (in writing), of the existence of the development of any defects in, or repairs required to, the scheduled equipment which the contractor considers he/she is not responsible for under the terms of the contract.
12.2. Contactor shall furnish the COR with a written estimate of the cost to make necessary repairs.
13. Condition of Equipment:
13.1. The contractor accepts responsibility for the equipment described in “as is” condition.
13.2. Failure to inspect the equipment prior to contract award shall not relieve the contractor from performance of the requirements of this contract.
14. Test Equipment:
14.1. Test equipment calibration shall be traceable to National Institutes of Standard Technology standards. Service report shall list test equipment used for calibration, to include serial number, model number, manufacturer date calibrated and date calibration due. Test equipment out of calibration shall not be used.
15. Identification, Parking, Smoking, and VA Regulations:
15.1. Contractor’s FSE(s) shall wear visible identification at all times while on the premises of the VA. Identification shall include, as a minimum, the employee’s name, position, and the contractor’s trade name.
15.2. It is the responsibility of the contractor to park in the appropriate designated parking areas. Information on parking is available from VA Police Service. VA will not invalidate or make reimbursement for parking violations of the contractor under any conditions.
15.3. Smoking is prohibited inside all VA buildings.
15.4. Possession of weapons is prohibited. Enclosed containers, including tool kits, shall be subject to search.
15.5. Violations of VA regulations may result in citation answerable in the United States (Federal) District Court, not a local district, state or municipal court.
16. Contractor Qualifications:
16.2. “Fully qualified” is based upon training and on experience in the field. For training, the FSE(s) has successfully completed a formalized training program for the equipment identified in this solicitation as required by the Original Equipment Manufacturer (OEM) and equal to what the manufacturer provides their own field service personnel.
16.3. Contractor must provide, upon request, evidence of appropriate training of any FSE(s) providing services under terms of the contract. Subcontracting of any ensuing award of this solicitation will not be allowed without written permission of the Contracting Officer.
16.4. Contractor must have access to all OEM proprietary information due to the critical nature of these services. Examples of this information would be software updates and factory service bulletins that describe updates/modifications needed to make the equipment under this contract safe for use.
17. Quality Assurance Surveillance Plan
| Performance Objective |
| SOW Para |
| Performance Threshold |
| Unscheduled Maintenance |
| 6.1 |
| No more than ONE 1 COR write-up per quarter. Repeat complaints/ discrepancies for the same area/ facility will result in an unacceptable rating for the month. |
| Scheduled Maintenance |
| 7.1 |
No more than 1 COR write-up per quarter. Repeat complaints/ discrepancies for the same area/ facility will result in an unacceptable rating for the month.
Reporting Requirements
| 11.2 |
| No more than 1 COR write-up per quarter. Repeat complaints/ discrepancies for the same area/ facility will result in an unacceptable rating for the month. |
| Test Equipment |
| 14.1 |
| No more than 1 COR write-up per quarter. Repeat complaints/ discrepancies for the same area/ facility will result in an unacceptable rating for the month. |
Page 1 of