36C26226Q1440_1.docx
DOCX document 19 KB Posted
- Attached to
- 6640--691 CFX Opus 384 Real-Time PCR System
- Solicitation number
- 36C26226Q1440
About this file
This is a Request for Quotation (RFQ) for the purchase of laboratory equipment and accessories for real-time quantitative PCR (qPCR) applications. The Department of Veterans Affairs Veterans Health Administration, Veterans Integrated Service Network 22, located at the VA Greater Los Angeles System (11301 Wilshire Blvd, Los Angeles, CA 90073), is soliciting quotes for one CFX Opus 384 Real-Time PCR System and one T100 Thermal Cycler Thermal Cycler System. The equipment will be used to qualify and quantify specific colon cancer genes in patient tissue samples for Dr. Pisegna's Colorectal Cancer Clinical & Computational Collaborative funded research study.
The solicitation is issued under simplified acquisition procedures for commercial products in accordance with FAR subpart 12.202, with the associated NAICS code 339113 (small business size standard of 800 employees) and FSC/PSC code 6515. Key technical specifications for the CFX Opus 384 system include dimensions of 33 x 56 x 36 cm, weight of 22 kg, temperature range of 4-100°C with a maximum ramp rate of 2.5°C/second, thermal accuracy of ±0.2°C, and optical excitation via 5 filtered LEDs. This is not a set-aside procurement, and no separate written solicitation document will be issued. Interested vendors should submit quotations directly in response to this combined synopsis/solicitation notice.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Combined Synopsis/Solicitation Notice Combined Synopsis/Solicitation Notice
| SUBJECT* |
| 691 CFX Opus 384 Real-Time PCR System |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 90815 |
| SOLICITATION NUMBER* |
| 36C26226Q1440 |
| RESPONSE DATE/TIME/ZONE |
| 09-11-2026 10:00 AM PACIFIC TIME, LOS ANGELES, USA |
| ARCHIVE |
| 60 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6640 |
| NAICS CODE* |
| 334516 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office 22 4811 Airport Plaza Drive Suite 600 Long Beach CA 90815
POINT OF CONTACT*
Contracting Officer Jeanette Otwell jeanette.otwell@va.gov
PLACE OF PERFORMANCE
| ADDRESS |
| Department of Veterans Affairs |
VA Greater Los Angeles System
DELIVER TO: WLA B115 R319 JOSEPH PISEGNA
11301 Wilshire Blvd.
Los Angeles CA
| POSTAL CODE |
| 90073 |
| COUNTRY |
| US |
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
Description This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202, “Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services,” as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.
This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01.
This solicitation is NOT a set-aside.
The associated North American Industrial Classification System (NAICS) code for this procurement is 339113, with a small business size standard of 800 employees.
The FSC/PSC is 6515.
The VA Greater Los Angeles System 11301 Wilshire Blvd.
Los Angeles, CA 90073 is seeking CFX Opus 384 Real-Time PCR System.
All interested companies shall provide quotations for the following:
Supplies/Services
| Product Code |
| Product Name |
| Qty |
| 12011452 |
| CFX Opus 384 Real-Time PCR System |
| 1 |
| 1861096 |
| T100 Thermal Cycler Thermal cycler system |
| 1 |
1. Salient Characteristics:
We are requesting the following requirements for the purchase of a PCR system with accessories and software for real-time quantitative PCR (qPCR) application to qualify and quantify specific colon cancer genes in patient tissue samples in Dr. Pisegna’s Colorectal Cancer Clinical & Computational Collaborative funded research study.
· Dimensions (W x D x H): 33 x 56 x 36 cm (13 x 22 x 14 in.)
· Weight: 22 kg (48 lb)
· Temperature Range: 4–100°C
· Lid Heating Range: 30–110°C
· Maximum Ramp Rate: 2.5°C/sec
· Average Ramp Rate: 2.0°C/sec
· Thermal Accuracy: ±0.2°C
· Thermal Uniformity: ±0.3°C (max–min ≤ 0.6°C)
· Gradient Operational Range: 30–100°C; Programmable Span: 1–24°C
· Optical Excitation: 5 filtered LEDs
· Optical Detection: 5 filtered photodiodes
· Excitation/Emission Wavelength Range: 450–690 nm
· Scan Time (All Channels): <20 seconds; Single Channel: 8 seconds
· Dynamic Range: 10 orders of magnitude
· Sensitivity: Detects 1 copy of target sequence in human genomic DNA
· Multiplex Capability: Up to 4 targets per well
· Sample Capacity: 384 wells
· Sample Volume: 1–30 µl (5–30 µl recommended)
· System Type: Fixed 384-well, 4-color plus FRET, network-connected real-time PCR detection system
· User Interface: Adjustable touch screen, rotation 12–55°
· Communications: USB 2.0 or above, Ethernet, WiFi
· Operating System: Windows 10 IoT
· Electrical Approvals: IEC, CE
· Software Included: CFX Maestro Software 2.3 for Windows PC — includes plate setup, data collection, statistics, and graphing
· Wi-Fi Adapter Included: CFX Opus Wi-Fi Adapter (North America)
· Warranty: 1-year manufacturer's warranty; extended warranty options available
· Training: Field Application Scientist on-site training included with purchase
Delivery shall be provided no later than 30 days after receipt of order.
The full text of FAR provisions or clauses may be accessed electronically at https://www.acquisition.gov/browse/index/far.
Submission of your response shall be received not later than Monday, September 011, 2026, at 10:00 am PT Local Time.
Late submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).
| *= Required Field |
| Combined Synopsis/Solicitation Notice |
Combined Synopsis/Solicitation Notice
File details come from the government source that posted it. Updated .