Attachment A - Salient Characteristics.docx

DOCX document 18 KB Posted

Attached to
6640--Refrigerated Lab Centrifuge
Solicitation number
36C26226Q1389
Issued by

About this file

This is an Attachment A document outlining the salient characteristics for a Refrigerated Lab Centrifuge procurement by the Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 22 (VISN 22) for the VA Greater Los Angeles Healthcare System.

This document serves as a specification attachment to a Request for Information (RFI) and sources sought notice (Solicitation Number 36C26226Q1389), issued solely for information and planning purposes to identify qualified potential sources. The procurement seeks a refrigerated lab centrifuge that meets minimum salient characteristics specified in this attachment. Responses to this RFI are encouraged and permitted under FAR 15.201(e); however, responses are not considered offers and cannot form binding contracts. The government intends to use submitted information to inform future acquisition decisions and may publish a formal solicitation announcement following review of responses. The NAICS code applicable to this procurement is 334516 with a size standard of 1,000 employees. Interested sources must demonstrate their capability to provide supplies meeting the specified salient characteristics, with the understanding that the identified information is descriptive rather than restrictive and indicates the quality level required for satisfactory performance.

View the file

Other files

File Type Posted
RFI - 36C26226Q1389 - Refrigerated Lab Centrifuge.docx DOCX document
36C26226Q1389.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT A – SALIENT CHARACTERISTICS

REFRIGERATED LAB CENTRIFUGE

SALIENT CHARACTERISTICS:

Capacity and Performance Minimum Requirements

· 4: High capacity: holds up to 4 × 500 mL or 16 microplates per run

· Broad compatibility: accommodates swing-bucket, fixed-angle, and plate rotors.

· Must be able to accommodate centrifusion of tubes

· Must be able to reach spin speeds of 3,000 rpm and above Safety and Ergonomics

· Automatic rotor recognition: identifies attached rotors to restrict speeds past safe limits.

· Imbalance detection: stops the motor automatically if loads are uneven.

· QuickLock options: uses aerosol-tight caps and lids designed for one-hand use.

Build and Operation

· Quiet operation: engineered to keep noise low and improve the work environment.

· Must be refrigerated: for specimen that require low temperature centrifusion

· An operational temperature range of 0 °C to +30 °C

· ECO shut-off feature that activates after 8 hours of non-use to reduce ambient energy consumption.

· Maintenance-free motor: built with a brushless design for long-term reliability.

· Minimum Need Custom programs: stores up to 35 user-defined routine programs Brake Specs

· Centrifuge minimum profile specifications of (5/5) programmable acceleration ramps and minimum 5 programmable braking ramps