This is a Questions and Answers document for Hydro-Jetting Services solicitation 36C26226Q0924 issued by the Department of Veterans Affairs for the San Diego VA Medical Center. The document clarifies key scope parameters for the requested services, which include both hydro-jetting and CCTV video inspections of a sewer system (not septic tank) serving multiple building areas and systems.

The scope encompasses approximately 1,850 linear feet of hydro-jetting across nine distinct locations: B122 Dishwash Area (100 LF), B128 Main Kitchen (175 LF), Room 1374 floor drains and cleanouts (150 LF), Warehouse Area grease main and sewer mains (200 LF), Main Grease Trap inlet and outlet lines (100 LF), Exterior Storm Drains and building jet back (225 LF), Building #2 Cooling Tower Area (250 LF), Building #2 Cogen Indoor Floor Drains (125 LF), Building #2 Chiller Indoor Floor Drains (125 LF), and Basement Mezzanine Area (400 LF). The piping system includes multiple diameters: primarily 4-inch pipes with occasional 3-inch and 2-inch sections. The RFQ deadline is June 24, 2026, at 12 PM PST/MST, with questions due by June 17, 2026, at 12 AM PST/MST. All inquiries and submissions must be directed to Charity Cazee at the Network Contracting Office 7.

View the file

Other files for this federal contract opportunity

Other files attached to J045--HYDROJETTING WITH A CAMERA SERVICES, newest first.
File Type Posted
36C26226Q0924 0001.docx DOCX document
FMS Vendor File Update Request Form.pdf PDF
S02 - 36C26226Q0924 - Hydro-Jetting.pdf PDF
VA10091.pdf PDF
W-9 Form.pdf PDF
36C26226Q0924_1.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Hydro-Jetting Services 36C26226Q0924 Questions & Answers

· Is this sewer or Septic Tank? Sewer

· Is this just cleaning services or will you be needing CCTV video inspections? Both

· What size are the pipes: most drainpipes are 4” but occasionally there are (3”/2”) drainpipes. There are 4”, 3”, and 2” drainpipes.

· Approx how many linear feet will need to be hydro jetted?

Location / System
Estimated LF

B122 – Dishwash Area (3 cleanouts)

100 LF

B128 – Main Kitchen (2 cleanouts, 5 floor drains)
175 LF
Room 1374 – Floor drains & cleanouts allowance
150 LF
Warehouse Area – Grease Main & 2 Sewer Mains
200 LF
Main Grease Trap – Inlet & Outlet Lines
100 LF
Exterior Storm Drains (2) & Jet Back Under Building
225 LF
Building #2 – Cooling Tower Area (4 storm drains, 8 sinks)
250 LF
Building #2 – Cogen Indoor Floor Drains
125 LF
Building #2 – Chiller Indoor Floor Drains
125 LF
Basement Mezzanine Area
400 LF
TOTAL ESTIMATED HYDROJETTING
1,850 LF