PT-3-Layout1.pdf
PDF 692 KB Posted
- Solicitation number
- 36C26226Q0417
About this file
This is a third-floor architectural floor plan for a healthcare facility. The plan depicts the layout of multiple rooms and spaces, including research laboratories (3C-26, 3C-27), offices (3C-27A, 3C-27B, 3C-27C, 3C-26A, 3C-26B, 3C-32, 3C-33), an endoscopy suite (3D-71), a restroom (3D-71A), a clean utility room (3A-61), a corridor (C3-73, C3-74), and a shaft (SH03-8). Room dimensions are provided in square footage, ranging from approximately 11.47 to 490.41 square feet. Three nurse stations are identified: one at 3D-22 (3 SE), one at 3D-75 (SSU), and another at 3D-22 (3 SE).
The floor plan includes mechanical and utility routing indicated by blue and red lines representing various building systems. Multiple reference callouts and annotations are marked throughout the plan with red boxes and labels. The document contains an authorizing authority table and a legend indicating compliance with building codes and design standards. The plan is designated as Sheet PPT-3 and includes directional orientation with a north arrow. This appears to be a construction or renovation document for a healthcare facility requiring detailed spatial planning and mechanical systems coordination.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| PT-1-Layout1.pdf | ||
| S02 CSS QnA 36C26226Q0417_4.docx | DOCX document | |
| PT-2-Layout1.pdf | ||
| 36C26226Q0417_4.docx | DOCX document | |
| PT-4-Layout1.pdf | ||
| 36C26226Q0417_3.docx | DOCX document | |
| S02 CSS QnA 36C26226Q0417_3.docx | DOCX document | |
| 36C26226Q0417_2.docx | DOCX document | |
| 36C26226Q0417_1.docx | DOCX document | |
| 36C26226Q0417.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
THIRD FLOOR
3C-27A
OFFICE
88.92
3C-33
OFFICE
106.71
SH03-8
SHAFT
11.47
C3-74
CORR
GS
368.32
3C-27C
LAB
305.48
3C-32
OFFICE
99.44
C3-73
3A-61
CLEAN UTIL
111G
84.68
3C-27B
OFFICE
3A-62
111G
63.19
3C-27
RSRCH LAB
206.04
3A-57
CHIEF OFF
146.78
3C-26
RSRCH LAB
490.41
3A-58
PHYS-OFF
119.69
387.92
3D-71
ENDOSCOPY
111G
237.94
3C-26A
OFFICE
92.96
3D-71A
RESTROOM
50.06
3C-26B
OFFICE
88.92
H
H
H
H
H
H
H
H
H
H
H
HH
H
H
H
H
H
H
H
H
3 SE
Nurses Station
Station: 3D-22
SSU
Nurses Station
Station: 3D-75
3 SE
Nurses Station
Station: 3D-22