36C26225Q1450.docx
DOCX document 20 KB Posted
- Attached to
- 6515--691-25-3-685-0211 Pentamix 3 Mixing Units
- Solicitation number
- 36C26225Q1450
About this file
This document is a Sources Sought Notice (RFI) issued by the Department of Veterans Affairs (VA) Network Contracting Office in Long Beach, California, seeking potential suppliers for a Pentamix 3 Mixing Unit for the VA Greater Los Angeles Healthcare System. The solicitation targets businesses within NAICS code 339112 with a size standard of 1,000 employees and requires a specific medical device with 12 detailed salient characteristics, including an automatic impression materials mixer that is portable (11x9x11 inches), capable of void-free putty dispensing, and compatible with specific dental impression materials.
Responses are due by September 3, 2025, at 4:00 PM PST and must be submitted via email to Emiljan.Golemi@va.gov. The RFI requests comprehensive information from potential vendors, including capabilities statements, business size status, manufacturing/distribution details, compliance with subcontracting limitations, Buy American Act conformance, lead times, FDA clearance, federal contract schedule information, and general pricing. The VA emphasizes that this is a market research exercise and not a formal solicitation, with responses to be used for future acquisition planning.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S05 RFI Pentamix 3 Mixing Unit.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice Sources Sought Notice
| SUBJECT* |
| 691-25-3-685-0211 Pentamix 3 Mixing Units |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 90815 |
| SOLICITATION NUMBER* |
| 36C26225Q1450 |
| RESPONSE DATE/TIME/ZONE |
| 09-03-2025 16:00 PACIFIC TIME, LOS ANGELES, USA |
| ARCHIVE |
| 30 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6515 |
| NAICS CODE* |
| 339112 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office 22 4811 Airport Plaza Drive Suite 600 Long Beach CA 90815
POINT OF CONTACT*
PLACE OF PERFORMANCE
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT/RFI IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY. THIS IS NOT A SOLICITATION.
THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).
DISCLAIMER
This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
SOURCES SOUGHT/RFI DESCRIPTION
This is NOT a solicitation announcement. This is a Sources Sought/RFI only. The purpose of this Sources Sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 339112 (size standard of 1,000 Employees). Responses to this RFI/Sources Sought Notice will be used by the Government to make appropriate acquisition decisions. After review of the responses to this RFI/Sources Sought Notice, further RFIs and/or a solicitation or other announcements may be published.
The Department of Veterans Affairs (VA), VISN 22 Long Beach Network Contracting Office is seeking sources capable of providing Pentamix 3 Mixing Unit for the VA Greater Los Angeles Healthcare System that can address the draft salient characteristics described below.
Brandname Information:
Manufacturer & Part Number(s): Henry Schein, Inc, 7770129 Type: Pentamix 3 Mixing Unit Equal to product name: Mixing Unit
Salient Characteristics:
1. Must have automatic impression materials mixer
2. Must have one button Operation
3. Must be portable/able to fit on small countertop: no greater than 11 X9X 11 in, no heavier than 9.9 kg
4. Must dispense void-free putty evenly (ISO type 0)
5. Must have extrusion force 6.500 N
6. Must have plunger forward speed max 45MM/MIN
7. Must have plunger, retraction manual, typically 3 seconds
8. Must have rate of dispensing greater than 150 ML/minute
9. Must be equipped with a sensor to determine in eligible cartridges
10. Must have automatic adjustment Of device parameters to rhealogical properties of impression material
11. Must be compatible with materials used within GLAVA dental clinics imprint 3 Heavy vinyl polysiloxane (VPS) impression material and Imprint 4 penta super quick vinyl polysiloxane (VPS)
12. Must be compatible with already owned VA products will allow for continuity of care for providers that go to multiple facility sites The list of draft characteristics is intended to be descriptive, not restrictive, of the supplies and/or services that are required.
If your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:
(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of draft salient characteristics described below. For instances where your company cannot meet the draft salient characteristic(s), please explain. For instances where your company can meet the draft salient characteristic(s), please show how your company meets/exceeds each requirement.
(2) Please review the list of draft salient characteristics and provide any additional feedback or suggestions. If none, please reply as N/A.
(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.
(4) Is your company considered small under the NAICS code identified in this RFI?
(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of draft salient characteristics?
(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).
(7) If you’re a small business and you are an authorized distributor/reseller for the items identified above, do you alter, assemble, or modify the items requested in any way? If you do, state how and what is altered, assembled, or modified.
(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR § 125.6?
(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?
(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?
(11) Please indicate whether your product conforms to the requirements of the Buy American Act? If you are unsure, please state the country of origin for each item.
(12) What is your lead time to deliver all items?
(13) Does your proposed equipment have FDA clearance (if needed)? Please specify what FDA clearance(s) have been obtained.
(14) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).
(15) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.
(16) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.
(17) Please provide your SAM.gov Unique Entity ID number.
Responses to this notice shall be submitted via email to Emiljan.Golemi@va.gov. Telephone responses will not be accepted. Responses must be received no later than Wednesday, September 3, 2025, by 4:00 PM PST.
All responses to this RFI/Sources Sought will be used for planning purposes only. Responses to this RFI/Sources Sought Notice are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued because of the information provided from this RFI, all interested parties must respond to the specific posting separately in accordance with the specifications of that announcement.
See attached document: S05 RFI Pentamix 3 Mixing Unit.
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
File details come from the government source that posted it. Updated .