36C26225Q0525.docx
DOCX document 20 KB Posted
- Attached to
- 6515--678-25-1-071-0015 Fluke Federal contract opportunity
- Solicitation number
- 36C26225Q0525
About this file
This is a Sources Sought/Request for Information (RFI) issued by the Department of Veterans Affairs VISN 22 Long Beach Network Contracting Office seeking information about potential suppliers of a Defibrillator Analyzer system for the VA Tucson Healthcare System. The notice has a response deadline of February 24, 2025, at 4:00 PM PST and falls under NAICS code 334515 with a size standard of 1,000 employees.
The required equipment includes a Fluke Electronics Corporation Defibrillator/Transcutaneous Pacer Analyzer (Model IMPULSE 7000DP) or equivalent, along with compatible 4mm multi-function electrodes and adapter cables. Key requirements include multiple loads for performance testing, portability, 10 independent ECG outputs providing 12 lead combinations, compatibility with various defibrillator models, long-lasting battery, and flexible heart-rate settings. Interested vendors must address 17 specific questions covering capabilities, business size status, manufacturing/distribution status, Buy American Act compliance, FDA clearances, federal contract vehicles, and pricing information. Responses should be emailed to Emiljan.Golemi@va.gov.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| S05 RFI 36C26225Q0525 - Defibrillator Analyzer.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice Sources Sought Notice
| SUBJECT* |
| 678-25-1-071-0015 Fluke |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 90815 |
| SOLICITATION NUMBER* |
| 36C26225Q0525 |
| RESPONSE DATE/TIME/ZONE |
| 02-24-2025 16:00 PACIFIC TIME, LOS ANGELES, USA |
| ARCHIVE |
| 30 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6515 |
| NAICS CODE* |
| 334515 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office 22 4811 Airport Plaza Drive Suite 600 Long Beach CA 90815
POINT OF CONTACT*
PLACE OF PERFORMANCE
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT/RFI IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY. THIS IS NOT A SOLICITATION.
THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).
DISCLAIMER
This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
SOURCES SOUGHT/RFI DESCRIPTION
This is NOT a solicitation announcement. This is a Sources Sought/RFI only. The purpose of this Sources Sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 334515 (size standard of 1,000 Employees). Responses to this RFI/Sources Sought Notice will be used by the Government to make appropriate acquisition decisions. After review of the responses to this RFI/Sources Sought Notice, further RFIs and/or a solicitation or other announcements may be published.
The Department of Veterans Affairs (VA), VISN 22 Long Beach Network Contracting Office is seeking sources capable of providing Defibrillator Analyzer for the VA Tucson Healthcare System and that can address the draft salient characteristics described below.
Brandname Information:
Manufacturer & Part Number(s): Fluke Electronics Corporation, 3065511 Type: I6/7 D/P ADPT109, ZOLL MEDICAL PD-2200 MULTIFUNCTION 4MM Equal to product name: Electrodes
Manufacturer & Part Number(s): Fluke Electronics Corporation, 3065461 Type: I6/7 D/P ADPT104, MED ERS/PHYSIO-CONTROL QUIK COMBO 4MM Equal to product name: Adapter Cables
Manufacturer & Part Number(s): Fluke Electronics Corporation, 2811919 Type: IMPULSE 7000DP, DEFIBRILLATOR/TRANSCUTANEOUS PACER ANALYZER Equal to product name: Defibrillator Analyzer
Salient Characteristics:
1. Defibrillator Analyzer
a. Must provide multiple loads for performance testing
b. Will be portable
c. Shall contain 10 independent ECG outputs that provide 12 lead combinations for standardized clinical signals
d. Must be compatible with a variety of defibrillator models
e. Will contain a long-lasting battery
f. Will contain flexible heart-rate settings to facilitate accuracy while testing
2. Multi-Function Electrodes
a. Must be a size of 4mm
b. Must be compatible with the chosen defibrillator analyzer
c. Will be connected to the defibrillator tester and the defibrillator to ensure the output of Jules is correct
3. Adapter Cables
a. Must be a size of 4mm
b. Must be compatible with the chosen defibrillator analyzer
c. Will be compatible with different defibrillator models, as each unit has different sized cable ports The list of draft characteristics is intended to be descriptive, not restrictive, of the supplies and/or services that are required.
If your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:
(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of draft salient characteristics described below. For instances where your company cannot meet the draft salient characteristic(s), please explain. For instances where your company can meet the draft salient characteristic(s), please show how your company meets/exceeds each requirement.
(2) Please review the list of draft salient characteristics and provide any additional feedback or suggestions. If none, please reply as N/A.
(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.
(4) Is your company considered small under the NAICS code identified in this RFI?
(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of draft salient characteristics?
(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).
(7) If you’re a small business and you are an authorized distributor/reseller for the items identified above, do you alter, assemble, or modify the items requested in any way? If you do, state how and what is altered, assembled, or modified.
(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR § 125.6?
(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?
(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?
(11) Please indicate whether your product conforms to the requirements of the Buy American Act? If you are unsure, please state the country of origin for each item.
(12) What is your lead time to deliver all items?
(13) Does your proposed equipment have FDA clearance (if needed)? Please specify what FDA clearance(s) have been obtained.
(14) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).
(15) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.
(16) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.
(17) Please provide your SAM.gov Unique Entity ID number.
Responses to this notice shall be submitted via email to Emiljan.Golemi@va.gov. Telephone responses will not be accepted. Responses must be received no later than Monday, February 24, 2025, by 4:00 PM PST.
All responses to this RFI/Sources Sought will be used for planning purposes only. Responses to this RFI/Sources Sought Notice are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued because of the information provided from this RFI, all interested parties must respond to the specific posting separately in accordance with the specifications of that announcement.
See attached document: S05 RFI 36C26225Q0525 - Defibrillator Analyzer.