S06 36C26223Q0909 0001.docx

DOCX document 48 KB Posted

Attached to
H944--BOILER MAINTENANCE & AQMD CERTIFICATION Federal contract opportunity
Solicitation number
36C26223Q0909
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 22

About this file

This solicitation requests quotes for boiler plant maintenance, safety device testing, calibration, and Air Quality Management District compliance services at two Department of Veterans Affairs medical centers in California. Products and services required include annual and semi-annual boiler safety device testing, maintenance, quarterly burner tuning and third-party testing, instrument calibration, emergency repairs, operator training, and propane vaporizer servicing. The base period of performance is July 2023 through June 2024 with the potential for four additional option years. Quotes are due by May 12, 2023 and must be submitted electronically to the specified contracting officer. Award will be determined by comparing quotes based on price and past performance. The solicitation is set aside exclusively for Service-Disabled Veteran-Owned Small Businesses.

View the file

Other files for this federal contract opportunity

Other files attached to H944--BOILER MAINTENANCE & AQMD CERTIFICATION, newest first.
File Type Posted
S06 36C26223Q0909 0002.docx DOCX document
36C26223Q0909.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

5. PROJECT NUMBER (if applicable)

CODE

7. ADMINISTERED BY

2. AMENDMENT/MODIFICATION NUMBER

CODE

6. ISSUED BY

8. NAME AND ADDRESS OF CONTRACTOR

4. REQUISITION/PURCHASE REQ. NUMBER

3. EFFECTIVE DATE

9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED

PAGE OF PAGES

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED

BPA NO.

1. CONTRACT ID CODE

FACILITY CODE

CODE

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers

E. IMPORTANT:

is extended,

(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.

12. ACCOUNTING AND APPROPRIATION DATA

(REV. 11/2016)

is required to sign this document and return ___________ copies to the issuing office.

is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.

15C. DATE SIGNED

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER

Contractor

16C. DATE SIGNED

14. DESCRIPTION OF AMENDMENT/MODIFICATION

16B. UNITED STATES OF AMERICA

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER

16A. NAME AND TITLE OF CONTRACTING OFFICER

15B. CONTRACTOR/OFFEROR

STANDARD FORM 30

PREVIOUS EDITION NOT USABLE

Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.)

(If required)

(SEE ITEM 11)

(SEE ITEM 13)

(X)

CHECK

ONE

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

(Signature of person authorized to sign) (Signature of Contracting Officer) 691-23-3-5091-0134 36C262 Department of Veterans Affairs NCO 22 - Network Contracting 335 East Germann Road, Ste 301 Gilbert AZ 85297-2919 36C262 Department of Veterans Affairs NCO 22 - Network Contracting 335 East Germann Road, Ste 301 Gilbert AZ 85297-2919 To all Offerors/Bidders

36C26223Q0909 05-02-2023

X X X 05/12/2023 at 14:00 PM MST See CONTINUATION Page X The purpose of this modification is to provide clarification to the Combined Synopsis/Solicitation 36C26223Q0909.

Please refer to the Questions/Responses page of this amendment for the questions and their responses.

No further questions will be accepted for this acquisition.

Helena A. Roba Branch Chief / Contracting Officer

CONTINUATION PAGE

Questions/Responses

1. Could you please provide details on the special requirements of this contract due to the AQMD?

Provide and conduct SCAQMD Certified Independent 3rd party Source Testing Company to perform SCAQMD rule 1146 quarterly periodic Source Testing on boilers 1, 2 and 3 on natural gas and propane in as found condition. Provide paper and digital reports for all test conducted. Note, the combustion readings must be taken at the test port located at the stack outlet with the portable analyzer.

Provide and conduct SCAQMD Certified Independent 3rd party Source Testing Company to perform SCAQMD rule 1146 Triannual Source Testing on boilers 1, 2 and 3 on natural gas at low, mid, and high firing rates. Provide paper and digital reports for all test conducted.

2. Elaborate on “perform annual boiler plant maintenance” as to what this is referring to and the expectations?

SACC ANNUAL BOILER MAINTENANCE:

· Conduct lock-out / tag-out on all boiler energy sources per VA shutdown schedule.

· Open boiler front and rear fireside doors. Remove all fireside gaskets and associated sealing insulation. Brush all fireside tubes free of deposits. Clean boiler front and rear tube sheets free of rust and debris. Clean boiler Morrison tube free of debris. Wash coat refractory surfaces as required. Provide all confined space equipment for inspecting and cleaning service.

· Disconnect, remove, and plug two (2) existing steam pressure relief valves.

· Conduct boiler hydrostatic test at 1.5 times the operating pressure with a pneumatic hydrostatic test pump and calibrated gauge. Inspect tube sheets for any water leakage at the seal welded and rolled boiler tube penetrations. Report test pressure and any leakage. Provide digital pictures of any leaks. Reinstall relief valves using new gaskets. Conduct hydrostatic test on economizer relief valve to verify proper operation.

· Drain waterside free of all water and debris. Open all man / hand-hole inspection / clean out plates and associated gaskets. Prepare all plates and associated rings for new gaskets. Inspect, clean, and lubricate all feed-water connections, strainers, and valves. Lubricate all steam and water valves.

· Tighten all steam valve and water packing glands.

· Remove all boiler water / steam column plugs, Warrick level probes and McDonald Miller float head for inspection and cleaning. Replace McDonald Miller level control wiper assembly. And Warrick level control probes with new stainless steel ¼” probes. Replace water column gauge glass and associated gaskets and connecting pipe crush washers. Replace liquid level float assembly gasket. Replace any plugged or defective piping nipples, fittings or valves found during the cleaning process. Flush out and remove all water side scale buildup from the belly of the boiler. Report amount of scale removed from the boiler. Retain scale sample for chemical testing contractor to analyze. Inspect and clean all boiler surface and bottom blow down connections. Remove and dispose of existing cast plugs. Replace all plugs removed with solid forged steel hex design.

· Open and remove any inspection plugs or access plates on the associated feed water economizers.

· Provide and schedule a Hartford qualified government boiler inspector to conduct VA require internal and external inspection on each of the three boilers.

· Have main boiler pressure gauge calibrated by a certified calibration lab.

· Close waterside and fireside using new gaskets after Boiler inspector’s internal inspections.

· Reinstall all water column floats, new probes and associated new plugs using new thread sealant, pipe tape and gaskets.

· Remove pilot assembly and associated ignition electrode. Clean and set electrode gap. Replace ignition electrode, associated cable and connector.

· Replace burner sealing gaskets if evidence of leak by is present.

· Conduct electronic leak test of all boiler’s natural gas / propane piping.

· Remove and clean Honeywell UV self- checking scanner lens and associated sight pipe.

· Calibrate all boiler pressure and temperature transmitters using certified calibration equipment. Provide calibration reports on all instruments calibrated.

· Inspect and clean associated boiler’s feed pump y-strainer and all other strainers in the boiler’s feed water supply piping.

· Tighten man/hand-hole gaskets and start boilers to normal operating pressure.

· Test the following boiler safety devices to verify proper operation after inspection: High water alarm, Low water alarm, Low water cut out, Auxiliary low water cut out, High steam pressure trip and Auxiliary high steam pressure trip. Conduct steam relief valve pop tests.

· Provide a paper and electronic report of inspection results, Boiler Inspectors Permit, instrumentation calibration reports combustion analysis reports and safety device operating status. Label all safety devices for current operating and trip set points.

· Clean up boiler area of all inspection / cleaning related debris.

DA and Condensate Tank

· Open, inspect, clean and test condensate tank and all associated level control controls and connecting pipes. Replace gauge glass and associated gauge glass isolation valves. Calibrate associated Honeywell level controller and valve I/P transducer. Conduct auto tune sequence on Honeywell UDC controller to update PID constants.

· Open, inspect, clean and test feed water DA tank and all associated level control controls and connecting pipes. Replace vacuum breaker. Replace gauge glass and associated gauge glass isolation valves. Calibrate associated Honeywell level controller and valve I/P transducer. Conduct auto tune sequence on Honeywell UDC controller to update PID constants.

· Open, inspect, clean and test bottom blow down tank and all associated controls, connecting pipes and cooling system.

· High water alarm.

· Auxiliary high water level alarm switch tests.

· Low water alarm switch tests.

· Auxiliary low water level alarm switch tests.

· Overflow valve switch tests.

· Safety valve following the DA PRV pop and accumulation tests.

· Calibrate DA Tank steam PRV inlet pressure transmitter and associated pressure gauge.

DANGEROUS AND TOXIC GAS SYSTEM TESTING:

· Inspect, calibrate, test, and label the following Dangerous and Toxic Gas Systems using supplied calibration gases and calibration equipment.

· Calibrate and test three (3) MSA propane dangerous gas sensors, transmitters and system audible/visual alarms.

· Calibrate and test four (4) MSA CO dangerous gas sensors, transmitters, and system audible/visual alarms.

· Calibrate and test three (3) MSA Methane dangerous gas sensors, transmitters, and system audible/visual alarms.

· Calibrate two (2) portable dangerous gas detectors.

· Provide and file dangerous and toxic gas system calibration and testing reports with steam plant supervisor.

· Provide and apply calibration and tested stickers for all instrument and systems tested.

LAACC ANNUAL BOILER MAINTENANCE:

· Conduct lock-out / tag-out on all boiler energy sources per VA shutdown schedule.

· Disconnect, remove, and plug 1 existing water pressure relief valve.

· Conduct boiler hydrostatic test at 1.5 times the operating pressure with a pneumatic hydrostatic test pump and calibrated gauge. Inspect firebox for any water leakage at tube sheet rolled boiler tube penetrations. Report test pressure and any leakage. Provide digital pictures of any leaks. Provide and install new how water pressure relief safety valve.

· Drain waterside free of all water.

· Open boiler front and rear waterside doors. Remove all waterside gaskets and associated seals. Brush all waterside tubes free of debris. Clean boiler waterside front and rear tube sheets free of rust and debris. Clean boiler firebox free of debris. Wash coat refractory surfaces as required. Provide all confined space equipment for inspecting and cleaning service. Remove all boiler water sensing column plugs, Warrick level probes and McDonald Miller float head for inspection and cleaning. Replace Warrick level control probes with new stainless steel ¼” probes. Replace liquid level float assembly gasket. Replace any plugged or defective piping nipples, fittings or valves found during the cleaning process. Flush out and remove all water side scale. Report amount of scale removed from the boiler. Retain scale sample for chemical testing contractor to analyze. Inspect and clean all boiler surface and bottom blow down connections. Remove and dispose of existing cast plugs. Replace all plugs removed with solid forged steel hex design.

· Inspect and clean firebox. Replace insulation as required.

· Provide and schedule a Hartford qualified government boiler inspector to conduct VA require internal and external inspection on each of the three boilers.

· Have main boiler pressure /temperature gauge calibrated by a certified calibration lab.

· Close waterside and fireside using new gaskets after Boiler inspector’s internal inspections.

· Reinstall all water column floats, new probes and associated new plugs using new thread sealant, pipe tape and gaskets.

· Remove pilot assembly and associated ignition electrode. Clean and set electrode gap. Replace ignition electrode, associated cable and connector.

· Replace burner sealing gaskets if evidence of leak by is present.

· Conduct electronic leak test of all boiler’s natural gas piping.

· Remove and clean Honeywell UV scanner lens and associated sight pipe.

· Calibrate all boiler pressure and temperature indicators using certified calibration equipment. Provide calibration reports on all instruments calibrated.

· Inspect and clean associated boiler’s makeup water system.

· Inspect barometric draft system for proper operation.

· Test the following boiler safety devices to verify proper operation after inspection: Low water cut out, Auxiliary low water cut out, High water temperature trip and Auxiliary high water temperature trips.

· Clean and lubricate burner combustion air blower damper assembly. Analyze and adjust burners on natural gas for SCAQMD permit conditions, efficiency, and safe operation throughout the burner operating range.

· Provide a paper and electronic report of inspection results, Boiler Inspectors Permit, instrumentation calibration reports combustion analysis reports and safety device operating status. Label all safety devices for current operating and trip set points.

· Clean up boiler area of all inspection / cleaning related debris.

· Place boiler online in automatic operation.

3. Could you please clarify “Conduct quarterly SCAQMD burner tuning and independent 3rd party testing?”

4. VHA 1810 states burner tuning is to be completed semi-annually so please verify you want it tuned quarterly?

· Yes. Question 3 and 4 are the same. The SCAQMD requires quarterly source testing, so it is best to do the tuning the same way to ensure we remain compliant.

5. Could you please define requirements on Perform annual propane vaporizer service?

Disconnect, remove, inspect, and replace as needed. (4) propane vaporizer regulating valve rubber hoses and calibrate (4) pressure gauges. Provide 3rd party Inspector to adjust and certify propane vaporizer pressure regulators for proper operation and specific gravity.

6. Could you please provide an equipment list for each site?

LIST OF EQUIPMENT:

Sepulveda Ambulatory Care Center (SACC):

Boiler #1– Superior Mohawk– Serial # 12965– Steam (Dual Fuel)
Boiler #2– Superior Mohawk– Serial # 12964– Steam (Dual Fuel)
Boiler #3– Superior Mohawk– Serial # 11963– Steam (Dual Fuel)
DA Tank– Wheeler Tank– Serial # 13202
Condensate Tank– Industrial Steam– Serial # 18238

Los Angeles Ambulatory Care Center (LAACC):

Boiler #1– Rite– National Board # 7968– Hot Water (Single Fuel)
Boiler #2– Rite– National Board # 7969– Hot Water (Single Fuel)
Boiler #3– Rite– National Board # 7967– Hot Water (Single Fuel)

7. Is National Boards Boiler Inspections to be included in this contract?

· This is what is meant by 3rd party inspector. A company like Hartford.

8. Will this solicitation have a signed LOS?

· No. This contract does not require an LOS as we are not requiring subcontractors for this requirement.

9. Can you provide a price sheet for your desired quote format?

· The Contract Line-Item Numbers (CLINs) are in section A.1 PRICE/COST SCHEDULE and reflect the sections that need to be priced.

A.1 PRICE/COST SCHEDULE

ITEM INFORMATION

ITEM NUMBER
DESCRIPTION OF SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant safety device testing, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

Contract Period: Base POP Begin: 07-01-2023 POP End: 06-30-2024 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying Equipment; Nuclear Reactors

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform semi-annual boiler plant safety device testing, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care

POP Begin: 07-01-2023 POP End: 06-30-2024 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant maintenance, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2023 POP End: 06-30-2024 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to conduct quarterly SCAQMD burner tuning and independent 3rd party testing, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2023 POP End: 06-30-2024 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant instrument calibrations, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2023 POP End: 06-30-2024 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual propane vaporizer service, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2023 POP End: 06-30-2024 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform emergency boiler plant repairs on a case-by-case basis, on any of the three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2023 POP End: 06-30-2024 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to conduct quarterly boiler and plant operator training, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2023 POP End: 06-30-2024 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant safety device testing, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2023 POP End: 06-30-2024 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform semi-annual boiler plant safety device testing, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2023 POP End: 06-30-2024 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant maintenance, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2023 POP End: 06-30-2024 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to conduct quarterly SCAQMD burner tuning, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2023 POP End: 06-30-2024 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant instrument calibrations, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2023 POP End: 06-30-2024 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform emergency boiler plant repairs on a case-by-case basis, on any of the three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care

POP Begin: 07-01-2023 POP End: 06-30-2024 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant safety device testing, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center Contract Period: Option 1 POP Begin: 07-01-2024 POP End: 06-30-2025 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform semi-annual boiler plant safety device testing, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2024 POP End: 06-30-2025 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant maintenance, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2024 POP End: 06-30-2025 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to conduct quarterly SCAQMD burner tuning and independent 3rd party testing, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2024 POP End: 06-30-2025 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant instrument calibrations, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2024 POP End: 06-30-2025 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual propane vaporizer service, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2024 POP End: 06-30-2025 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying Equipment; Nuclear Reactors

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform emergency boiler plant repairs on a case-by-case basis, on any of the three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2024 POP End: 06-30-2025 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to conduct quarterly boiler and plant operator training, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2024 POP End: 06-30-2025 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant safety device testing, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2024 POP End: 06-30-2025 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform semi-annual boiler plant safety device testing, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2024 POP End: 06-30-2025 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant maintenance, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2024 POP End: 06-30-2025 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to conduct quarterly SCAQMD burner tuning, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2024 POP End: 06-30-2025 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant instrument calibrations, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2024 POP End: 06-30-2025 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform emergency boiler plant repairs on a case-by-case basis, on any of the three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2024 POP End: 06-30-2025 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant safety device testing, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

Contract Period: Option 2 POP Begin: 07-01-2025 POP End: 06-30-2026 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform semi-annual boiler plant safety device testing, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care

POP Begin: 07-01-2025 POP End: 06-30-2026 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant maintenance, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2025 POP End: 06-30-2026 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to conduct quarterly SCAQMD burner tuning and independent 3rd party testing, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2025 POP End: 06-30-2026 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant instrument calibrations, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2025 POP End: 06-30-2026 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual propane vaporizer service, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2025 POP End: 06-30-2026 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform emergency boiler plant repairs on a case-by-case basis, on any of the three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2025 POP End: 06-30-2026 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to conduct quarterly boiler and plant operator training, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2025 POP End: 06-30-2026 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant safety device testing, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2025 POP End: 06-30-2026 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform semi-annual boiler plant safety device testing, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2025 POP End: 06-30-2026 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant maintenance, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2025 POP End: 06-30-2026 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to conduct quarterly SCAQMD burner tuning, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2025 POP End: 06-30-2026 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant instrument calibrations, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2025 POP End: 06-30-2026 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform emergency boiler plant repairs on a case-by-case basis, on any of the three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Contract Period: Option 2 POP Begin: 07-01-2025 POP End: 06-30-2026 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant safety device testing, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center Contract Period: Option 3 POP Begin: 07-01-2026 POP End: 06-30-2027 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform semi-annual boiler plant safety device testing, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2026 POP End: 06-30-2027 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant maintenance, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2026 POP End: 06-30-2027 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to conduct quarterly SCAQMD burner tuning and independent 3rd party testing, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2026 POP End: 06-30-2027 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant instrument calibrations, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2026 POP End: 06-30-2027 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual propane vaporizer service, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2026 POP End: 06-30-2027 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform emergency boiler plant repairs on a case-by-case basis, on any of the three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2026 POP End: 06-30-2027 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to conduct quarterly boiler and plant operator training, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2026 POP End: 06-30-2027 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant safety device testing, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2026 POP End: 06-30-2027 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying Equipment; Nuclear Reactors

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform semi-annual boiler plant safety device testing, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2026 POP End: 06-30-2027 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant maintenance, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2026 POP End: 06-30-2027 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to conduct quarterly SCAQMD burner tuning, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2026 POP End: 06-30-2027 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant instrument calibrations, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2026 POP End: 06-30-2027 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform emergency boiler plant repairs on a case-by-case basis, on any of the three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2026 POP End: 06-30-2027 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant safety device testing, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

Contract Period: Option 4 POP Begin: 07-01-2027 POP End: 06-30-2028 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform semi-annual boiler plant safety device testing, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Contract Period: Option 4 POP Begin: 07-01-2027 POP End: 06-30-2028 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant maintenance, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2027 POP End: 06-30-2028 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to conduct quarterly SCAQMD burner tuning and independent 3rd party testing, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2027 POP End: 06-30-2028 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant instrument calibrations, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2027 POP End: 06-30-2028 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual propane vaporizer service, on three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2027 POP End: 06-30-2028 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform emergency boiler plant repairs on a case-by-case basis, on any of the three (3) 400 hp, 16 mil BTU fire tube boilers, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2027 POP End: 06-30-2028 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to conduct quarterly boiler and plant operator training, at the Sepulveda Ambulatory Care Center (SACC).

POP Begin: 07-01-2027 POP End: 06-30-2028 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform annual boiler plant safety device testing, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers (RZ8.3-G-15/021151), at the Los Angeles Ambulatory Care Center (LAACC).

POP Begin: 07-01-2027 POP End: 06-30-2028 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and PRODUCT/SERVICE CODE: H944 - Other Quality Control, Testing, and Inspection - Furnace, Steam Plant, and Drying

1.00
YR
_____________
_____________

Provide all labor, materials, supplies, tools, equipment, parts, travel, ICRA Barriers, and qualified personnel to perform semi-annual boiler plant safety device testing, on three (3) Gordon-Piatt 1.750 mil BTU hot water boilers…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .