36C26220Q0374-0001000.docx
DOCX document Posted
- Attached to
- J045--Water Treatment VA San Diego
- Solicitation number
- 36C26220Q0374
About this file
This combined synopsis/solicitation seeks proposals for water treatment supplies and services for the central plant at the Veterans Affairs San Diego Healthcare System. Key requirements include chemical treatment and testing for boilers, cooling towers, chilled water loops, and condensate systems to control scaling, corrosion, and biological growth. The contractor must provide all necessary chemicals and test kits delivered to the site, with bulk chemicals stored in on-site containers. The contractor will also perform monthly testing and inspections, quarterly Legionella testing of cooling towers, and annual inspections of boilers and related equipment. Offerors must have five years of relevant experience and an accredited laboratory. The base period of performance is one year with four optional one-year extensions. Proposals are due by March 30, 2020 and the contract will be set aside for Service-Disabled Veteran-Owned Small Businesses.
36C26220Q0374 0001 36C26220Q0374 0001_1.docx
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C26220Q0374-0001001.docx | DOCX document | |
| 36C26220Q0374-0001002.xlsx | XLSX spreadsheet | |
| 36C26220Q0374-016.docx | DOCX document | |
| 36C26220Q0374-017.docx | DOCX document | |
| 36C26220Q0374-015.docx | DOCX document | |
| 36C26220Q0374-018.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Contract Opportunity Amendment to a Previous Combined Solicitation
CLASSIFICATION CODE
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
BASE NOTICE TYPE
RESPONSE DATE (MM-DD-YYYY)
ARCHIVE
DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
SET-ASIDE
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION
See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
GENERAL INFORMATION
PLACE OF PERFORMANCE
* = Required Field Contract Opportunity Amendment to a Previous Combined Solicitation J045 Water Treatment VA San Diego 90815 36C26220Q0374 03-31-2020 N
SDVOSBC
238220 Department of Veterans Affairs Network Contracting Office 22 4811 Airport Plaza Drive Suite 600 Long Beach CA 90815 Peter Kim peter.kim33@va.gov
VA
San Diego Healthcare System 3350 La Jolla Village Drive San Diego, CA 92161
USA
5. PROJECT NUMBER (if applicable)
CODE
7. ADMINISTERED BY
2. AMENDMENT/MODIFICATION NUMBER
CODE
6. ISSUED BY
8. NAME AND ADDRESS OF CONTRACTOR
4. REQUISITION/PURCHASE REQ. NUMBER
3.
EFFECTIVE DATE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED
PAGE OF PAGES
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED
BPA NO.
1. CONTRACT ID CODE
FACILITY CODE
CODE
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
E. IMPORTAN
T:
is extended,
(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.
12. ACCO
UNTING AND APPROPRIATION DATA
(REV. 11/2016)
is required to sign this document and return ___________ copies to the issuing office.
is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO:
Specify authority) THE CHANGES SET FORTH IN ITEM 14
ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.
15C. DATE SIGNED
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
RESULT IN REJECTI
ON OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and th is amendment, and is received prior to the opening hour and date specified.
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER
Contractor
16C. DATE SIGNED
14. DESCRIPTION OF
AMENDMENT/MODIFICATION
16B. UNITED STATES OF AMERICA
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SI
GNER
16A. NAME AND TITLE OF CONTRACTING OFFICER
15B. CONTRACTOR/OFFEROR
STANDARD FORM 30
PREVIOUS EDITION NOT USABLE
Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, et c.)
(If required)
(SEE ITEM 11)
(SEE ITEM 13)
(X)
CHECK
ONE
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
11. THIS ITEM ONLY APPLIES TO
AMENDMENTS OF SOLICITATIONS
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
(Signature of person authorized to sign) (Signature of Contracting Officer) 03-24-2020 None 00262 Department of Veterans Affairs Network Contracting Office 22 4811 Airport Plaza Drive Suite 600 Long Beach CA 90815 00262 Department of Veterans Affairs Network Contracting Office 22 4811 Airport Plaza Drive Suite 600 Long Beach CA 90815 To all Offerors/Bidders
36C26220Q0374 02-26-2020
X X X
This amendment is issued to post the RFIs and VA responses, to update Enclosure 2 on which offers are to be submitted, and to update the SOW to add paragraph 2.F.9. "Based on the uncertainty of chemicals required, a review of chemicals used will be conducted after 6 months to determine if the contracted costs need to be modified, and if required will be modified based on the "chemicals" workbook submitted with the contractor's offer."
All other terms and conditions remain unchanged.
REQUESTS FOR INFORMATION
Project Name: VASD Water Treatment Solicitation Number: 36C26220Q0374
1. Please provide the exact tonnage of each chiller/tower at the facility.
VA RESPONSE.
Chiller 1 & 2 1200 tons Chiller 3 1500 tons Absorption chiller 500 tons
2. Please provide the Boiler sizes, and average steam production on a yearly basis.
VA RESPONSE. Boiler 1 & 2 - max 24000 lbs/hour 3.7-5.5 million pounds/year
3. Are there any special CA restrictions on discharge from the site? Limits concerning Boiler or Cooling Tower blowdown?
VA RESPONSE. No
4. Who is the incumbent water treatment company and how long have they had the contract?
VA RESPONSE. This is the first contract in over 10 years. Chemtreat has been used periodically
5. Are there currently corrosion coupons installed? We did not see any. Bid says to test corrosion coupons in condensate once per year. Should we include cost of coupon rack in our bid?
VA RESPONSE. Yes
6. Please give us the daily water meter readings for total cooling tower makeup (1 month for all four), and cooling tower blowdown (all four) VA RESPONSE. No data Available.
7. Please give us the daily water meter readings (1 month) for boiler make up (gallons) or steam produced (lbs./hr) VA RESPONSE. Feedwater make-up approximate range 3000-6000 gal/day
8. What is the Condensate Return % for the Waste Heat Recovery Boiler and the online Fire tube boiler?
VA RESPONSE. No data Available.
9. Do you currently have a boiler polymer dispersant? We only saw Amine, Caustic and Sulfite. Bid says boiler polymer dispersant and phosphate are required.
VA RESPONSE. No
10. Do you have a non-ox currently being fed? We did not see any non -ox onsite. Bid request a non-ox biocide. Should we include cost for tank, pump and install?
VA RESPONSE. No. Yes please include cost
11. How many cycles of concentration are you running on the cooling tower?
VA RESPONSE. Data not available
12. Is the cooling tower makeup city, soft or D.I Water?
VA RESPONSE. City water
13. Are there any leaks in the closed loop System? IF so, what is the leak rate?
VA RESPONSE. Approximately 30-40 gal/day
14. Bid says Amine must be fed to the boiler for proper mixing, but current injection point is to the DA? Who is responsible to create injection point to the boiler?
VA RESPONSE. The vendor
15. Currently, the chilled loop is on a nitrite based chemical, does the VA want to stay with a nitrite chemical on a chilled loop system?
VA RESPONSE. Yes unless the make-up quality and make-up rate dictates a different compound is more suitable.
Must also meet or exceed VA master spec section 23 25 00
2.2 CHEMICAL TREATMENT FOR CLOSED LOOP SYSTEMS
| A. | Inhibitor: Provide sodium nitrite/borate, molybdate-based inhibitor or other approved proprietary compound suitable for makeup quality and makeup rate and which will cause or enhance bacteria/corrosion problems or mechanical seal failure due to excessive total dissolved solids. Shot feed manually. Maintain inhibitor residual as determined by water treatment laboratory, taking into consideration residual and temperature effect on pump mechanical seals. |
| B. | pH Control: Inhibitor formulation shall include adequate buffer to maintain pH range of 8.0 to 10.5. |
| C. | Performance: Protect various wetted, coupled, materials of construction including ferrous, and red and yellow metals. Maintain system essentially free of scale, corrosion, and fouling. Corrosion rate of following metals shall not exceed specified mills per year penetration; ferrous, 0-2; brass, 0-1; copper, 0-1. Inhibitor shall be stable at equipment skin surface temperatures and bulk water temperatures of not less than 121 degrees C (250 degrees F) and 52 degrees C (125 degrees Fahrenheit) respectively. Heat capacity reduction shall not exceed that allowed by fouling factor 0.0005. |
| D. | Pot Feeder: Bypass type, complete with necessary shut off valves, drain and air release valves, and system connections, for introducing chemicals into system, cast iron or steel tank with funnel or large opening on top for easy chemical addition. Feeders shall be 18.9 L (five gallon) minimum capacity at 860 kPa (125 psig) minimum working pressure. |
16. Has there been any challenges that the VA has been experiencing for all the systems that we should be aware of? Boiler, cooling and loops.
VA RESPONSE. The VA is not aware of any current challenges.
File details come from the government source that posted it. Updated .