VANCHCS Viable Sample Maps.pdf
PDF 185 KB Posted
- Attached to
- H266--Pharmaceutical Compounding Room/Hood Testing - VANCHCS Federal contract opportunity
- Solicitation number
- 36C26124Q0390
About this file
This document appears to be a set of viable sample maps related to a federal contract opportunity for pharmaceutical compounding room/hood testing at the VA Northern California Health Care System (VANCHCS). The maps show the layout and sample locations for various cleanroom spaces, including an ISO 7 clean area, ISO 8 compounding area, and biological safety cabinets (BSCs). The related federal contract opportunity, Solicitation Number 36C26124Q0390, is for this pharmaceutical compounding room/hood testing work at VANCHCS. The solicitation is being issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 21. The document does not provide additional details on the required products or services, response dates, pricing, or other contract specifics. It appears to be solely a set of facility maps and diagrams.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C26124Q0390 0003_1.docx | DOCX document | |
| QUESTIONS AND ANSWERS.pdf | ||
| Gowning and Garbing procedure VANCHCS.pdf | ||
| 36C26124Q0390 0002_1.docx | DOCX document | |
| Past Performance Survey.docx | DOCX document | |
| 36C26124Q0390 0001_1.docx | DOCX document | |
| RFQ 36C26124Q0390 - Pharmacy Hood Testing.pdf | ||
| 36C26124Q0390_1.docx | DOCX document | |
| 2015-5631_Rev.20_SACRAMENTO_12_26_2023.pdf | ||
| 2015-5653_Rev.19_SAN JOAQUIN_12_26_2023.pdf | ||
| 2015-5623_Rev.22_ALAMEDA_CONTRA COSTA_12_26_2023.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LAFW
BSC 1 BSC 2
Table
Pass-through (HEPA Filtered)
Pass-through (HEPA filtered)
Table
Table
Shelf Shelf Shelf
Shelf Fridge
Frid ge
Frid ge
Non-HD Buffer
ISO 8
Ante
C-SCA
Shelf
Table
Mather Compounding Trailer
PC
B en ch
Frid ge
S Viable Surface Sample Location
A Viable Air Sample Location
S1 A1 S2
S3
S4
S5
S6
S7
S8
A2 A3
A4
A5
A6
A7
A8 A9
S9
MAP IS NOT TO SCALE
BSC
Shelf
Table
Table
Shelf Shelf
ISO 7
Ante
HD-
Buffer
Non-
HD
Buffer
PC
Bench
Shelf
Mather Bldg. 700 5th floor
S Viable Surface Sample Location
A Viable Air Sample Location
S 1
A 1
S 2
A 2
S 3 S 4 S 5 S 6
S 7
S 8 A 3 A 4 A 5 A 6
A 7
Sh elf
LAFW
Table
Mather BLDG. 700 – 3rd Floor
- SCA
SCA
SCA
Tab le
S Viable Surface Sample Location
A Viable Air Sample Location
S 1 A 1
A 2
S 2
Pass-through
S 3
Shelf
4 ft
Pass-through Not HEPA filtered
Fridge
Shelf
Shelf Shelf
C-SCA
Mather BLDG. 647 – C - SCA
Cart
Bootie Butler
Shelf
Shelf Cart
C art
Table
Laptop
S Viable Surface Sample Location
A Viable Air Sample Location
S 1
S 2
S 3
S 4
A 1
A 2A 3
Martinez BLDG. 20 - SCA
4 ft Table
BenchShelf
Pass-through
Not HEPA filtered
Table SCA
S Viable Surface Sample Location
A Viable Air Sample Location
S 1 A 1 S 2
S 3
A 2
Table
BSC
Table Table
Shelf
Table
Fridge
Shelf
ISO 7
Ante
Non-
HD
Buffer
HD-
Buffer
Bench
PC
Martinez BLDG. 19
Pass-through (not HEPA filtered)
S Viable Surface Sample Location
A Viable Air Sample Location
S 1
S 3 S 2
S 4
S 5 S 6
S 7 S 8
A 1
A 2
A 3
A 4 A 5
A 8
A 6
A 7
S 9
HEPA filtered Pass through
HEPA filtered Pass through
HEPA filtered Pass through
HD Buffer Room
ISO 7
Non-HD Buffer Room
ISO 7
Ante Room
ISO 7
HD Storage Room
LAFW
BSC
Viable Samples TBD – Compounding Space will be certified as part of the new contract (September 2024)
Stockton IV Suite
| Slide 1 |
| Slide 2 |
| Slide 3 |
| Slide 4 |
| Slide 5 |
| Slide 6 |
| Slide 7 |
File details come from the government source that posted it. Updated .