36C26120R0007-000.docx

DOCX document Posted

Attached to
Install Anti-Ligature Door Alarms at Four VISN 21 Facilities
Solicitation number
36C26120R0007
Issued by

About this file

This sources sought notice from the Department of Veterans Affairs seeks information from contractors interested in installing anti-ligature door alarms at four VA facilities. The contractor will furnish, install, and interface a suicide deterrent and alarm system that detects attempts at suicide by supporting a ligature in a door assembly. The system must detect ligatures before pressure is applied, be addressable, self-monitoring, and capable of remote diagnostics. Installation locations include twenty-nine doors at the VA Northern California Health Care System, twelve doors at the VA Pacific Islands Health Care System, twenty doors at the VA Central California Health Care System, and fourteen doors at the VA Sierra Nevada Health Care System. The period of performance is 150 calendar days after notice to proceed. Interested contractors shall send their socio-economic category, DUNS number, maximum bonding capability for a single bid, and total maximum bonding capacity to megan.barr@va.gov by December 4, 2019 for consideration under the forthcoming solicitation.

36C26120R0007 36C26120R0007.docx

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Contract Opportunity Sources Sought Notice

CLASSIFICATION CODE

SUBJECT

CONTRACTING OFFICE'S

ZIP-CODE

SOLICITATION NUMBER

RESPONSE DATE (MM-DD-YYYY)

ARCHIVE

DAYS AFTER THE RESPONSE DATE

RECOVERY ACT FUNDS

SET-ASIDE

NAICS CODE

CONTRACTING OFFICE

ADDRESS

POINT OF CONTACT

(POC Information Automatically Filled from User Profile Unless Entered)

DESCRIPTION

See Attachment

AGENCY'S URL

URL DESCRIPTION

AGENCY CONTACT'S EMAIL

ADDRESS

EMAIL DESCRIPTION

ADDRESS

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

GENERAL INFORMATION

PLACE OF PERFORMANCE

* = Required Field Contract Opportunity Sources Sought Notice Z Install Anti-Ligature Door Alarms at Four VISN 21 Facilities 89502-2597 36C26120R0007 12-04-2019 N 238210 Department of Veterans Affairs VA Sierra Pacific Network (VISN 21) VA Sierra Nevada Health Care System 975 Kirman Avenue Reno NV 89502-2597 This is a sources sought notice for information and planning purposes and shall not be construed as an obligation on the part of the VA. The purpose of this sources sought is to identify qualified businesses, including Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), Small Disadvantaged Business (SDB), Woman-Owned Small Business (WOSB), Historically Underutilized Business Zone (HUBZone) Small Business, 8a Small Business and Small Business concerns that are interested in and are capable of performing the work described herein. Your responses to the sources sought will assist the Government in determining the appropriate acquisition method, including whether a set-aside is possible.

Department of Veterans Affairs, Network Contracting Office 21 will be issuing a Request for Proposal (RFP) to award a construction contract to a General Contractor who shall furnish, install, and interface a suicide deterrent and alarm system that detects attempts at suicide by supporting a ligature in a door assembly. The system will detect the presence of a ligature (such as a bed sheet, towel, etc.) before pressure is applied. Furthermore, the system shall be addressable, self-monitoring, and capable of remote diagnostics. The monitoring panel shall have an LCD display that will show the time and location of the event. Upon detection, a visual indicator shall be activated at the location of the event, as well as at a remote monitoring panel, typically located in the nurse’s station. In addition, an audible alarm shall also be activated in a predetermined hallway location, as well as at the remote monitoring panel in the Nurse’s Station. Once initiated, the alarm will remain active even if the ligature is removed and the alarm shall be manually reset using the keyed switch located near the door jamb. After being reset, the audible and visual indicators will be cleared. The system shall record and display at least 64 recent events in an electronic log, available for immediate review. All event messages are stored for a period of 1 year and are available for download. This system has the capability of recording events, including the date and time of each event, and shall be accessible for review as required. The system shall be installed in accordance with the manufacturer’s specifications of the door alarm. Installation will take place at the following locations:

· Twenty-nine doors at the VA Northern California Health Care System, 10535 Hospital Way, Mather, CA 95655

· Twelve doors at the VA Pacific Islands Health Care System, 459 Patterson Road 151, Honolulu, HI 96819

· Twenty doors at the VA Central California Health Care System, 2615 E Clinton Avenue, Fresno, CA 93703

· Fourteen doors VA Sierra Nevada Health Care System, 975 Kirman Avenue, Reno, NV 89502 The period of performance is 150 calendar days after issuance of the notice to proceed.

The NAICS code is 238210 and the corresponding size standard is $16.5 Million.

The disclosure of magnitude is between $500,000 and $1,000,000 Interested businesses shall send by email only, the following information: Socio-Economic Category, DUNS number, Maximum bonding capability for a single bid and total maximum bonding capacity. Information shall be sent to megan.barr@va.gov by close of business December 4, 2019.

File details come from the government source that posted it. Updated .