36C26119Q0998-002.xlsx

XLSX spreadsheet Posted

Attached to
Extend RFQ Close Date RFQ Close 09-18-2019
Solicitation number
36C26119Q0998
Issued by

About this file

36C26119Q0998 S02 36C26119Q0998 - Attachment A - Test Schedule and Estimated Volumes.xlsx

View the file

Other files

File Type Posted
36C26119Q0998-0002001.pdf PDF
36C26119Q0998-0002000.docx DOCX document
36C26119Q0998-0002001.pdf PDF
36C26119Q0998-0002000.docx DOCX document
36C26119Q0998-0001002.xlsx XLSX spreadsheet
36C26119Q0998-0001001.pdf PDF
36C26119Q0998-0001000.docx DOCX document
36C26119Q0998-0001001.pdf PDF
36C26119Q0998-0001002.xlsx XLSX spreadsheet
36C26119Q0998-0001000.docx DOCX document
36C26119Q0998-000.docx DOCX document
36C26119Q0998-001.pdf PDF
36C26119Q0998-000.docx DOCX document
36C26119Q0998-002.xlsx XLSX spreadsheet
36C26119Q0998-001.pdf PDF
Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Test Schedule

SUMMARYBPA PRICE BASED ON ESTIMATED ANNUAL KIT VOLUMES
Estimated Annual BPA Total$ - 0Catalog #Brand Name DescriptionEstimated Annual Kit TotalPriceInstrument/Analyzer Add OnService Add OnExtended Price
Estimated 5 Year BPA Total$ - 0FLM1-ASY-0124KIT, VERIFICATION FOR FOLLW UP INST
BCID - FLM1-ASY-01242$ - 0
FLM1-ASY-0130KIT, VERIFICATION FOR FOLLOW UP INST
GI - FLM1-ASY-01304$ - 0
FLM1-ASY-0145KIT VERIFICATION 2.0 ME - FLM1-ASY-
01452$ - 0
FLM1-ASY-0147RP2 START UP VERIFICATION KIT - FLM1-
ASY-01473$ - 0
FLM1-ASY-0150PNEUMONIA START-UP VERIFICATION KIT
- FLM1-ASY-01501$ - 0
RFIT-ASY-0116KIT GI PANEL IVD 30 TESTS - RFIT-ASY- 011688$ - 0
RFIT-ASY-0118KIT ME PANEL IVD 30 TESTS - RFIT-ASY- 01182$ - 0
RFIT-ASY-0126BCID PANEL, IVD, 30 TEST KIT - RFIT-ASY- 01269$ - 0
RFIT-ASY-0129RESPIRATORY PANEL 2-30 PACK KIT - RFIT-ASY-012917$ - 0
RFIT-ASY-0144PNEUMONIA PANEL, 30 TESTS - RFIT-ASY- 01441$ - 0
TOTAL$ - 0

The above part numbers and descriptions are the brand name descriptions. This is a BRAND NAME OR EQUAL requirement. If providing an EQUAL solution, please revise the part number and description, update the number of boxes required per year to match the output of the brand name product, and provide a detailed description of how your solution meets of exceeds the technical requirements as described within the attached SOW.

See Equipment & Service Tab for analyzer/equipment and service quantities per facility and VISN total.

Equipment & Service

QUANTITIES
VA NORCALVA PALO ALTOVA RENOVA SAN FRANCISCOTOTAL
Equipment DescriptionPart/Model Number
FA TORCH SYSTEM BASE BOX - HTFAASY-0001HTFA-ASY-000111114
FA TORCH MODULE BOX - HTFA-ASY-0003HTFA-ASY-0003242412
DUPLEX BOX - HTFA-ASY-0002HTFA-ASY-000201012
ServiceInput service quantities to provide full service for all of above equipment
BIOFIRE TORCH BASE MFG WARRANTY4706469
BIOFIRE TORCH MFG WARRANTY4706471
BIOFIRE TORCH BASE EXTENDED WARRANTY (4 YEARS)4706468
BIOFIRE TORCH EXTENDED WARRANTY (4 YEARS)4706470

The above part numbers and descriptions are the brand name descriptions. This is a BRAND NAME OR EQUAL requirement. If providing an EQUAL solution, please revise the part number and description and provide a detailed description of how your solution meets of exceeds the technical requirements as described within the attached SOW. If providing a brand name equal, please include a quote for 35 analyzers for VA Palo Alto.