PRODUCT DESCIPTION STATEMENT OF WORK

SPS Cameras

Cat6 Cabling

· 8- Cat6 cables from the PT/OT OI&T Closet to the SPS Area o 1- Cable in the Elevator Lobby o 1- Cable in the Clean Hallway

· 1- Cable in the Decontamination Hallway (Clean Area)

· 1- Cable in the Clean Equipment Storage Room by the entrance door (Clean Area) o 1- Cable in the Clean Equipment Storage Room by the emergency exit door (Clean Area) o 1- Cable in the Sterile Storage Room (Clean Area) o 1- Cable in the Preparation Room (Clean Area) o 1- Cable in the Clean HAC Decontamination Room

· Each location includes blue Berktek Lanmark6 plenum cable, blue Cat6 Panduit jacks, Panduit single port surface mount boxes and a 5’ blue Cat6 Panduit patch cord at the camera end

· Cables will be tested and labeled according to VA specifications upon completion

· Cables to be ran in a new and/or existing J-Hook path above the ceiling

· Cables in the “Clean Area” will be installed after normal business hours and will require overtime rates

· Cabling installation will require a new 2” EMT Conduit sleeve between the OI&T closet and the SPS Area

Cameras and Camera Installation

· 8- Panasonic WV-S4150 Cameras to be provided, installed and configured in the following locations:

· 1- Camera in the Elevator Lobby o 1- Camera in the Clean Hallway

· 1- Camera in the Decontamination Hallway (Clean Area)

· 1- Camera in the Clean Equipment Storage Room by the entrance door (Clean Area) o 1- Camera in the Clean Equipment Storage Room by the emergency exit door (Clean Area) o 1- Camera in the Sterile Storage Room (Clean Area) o 1- Camera in the Preparation Room (Clean Area) o 1- Camera in the Clean HAC Decontamination Room

· Cameras in the “Clean Area” will be installed after normal business hours and will require overtime rates

· Camera placement and installation be consulted with the VA Police prior to installation

· Camera initial programming will be completed with supplied IP Addresses, Administrator login and passwords supplied by VA Police

· Camera installation worksheet supplied by VA Police for each camera will be satisfactorily completed after installation

· Permits & Fees

· Concrete Coring & Patching

· Drywall Painting & Patching