This is Amendment 0001 to Solicitation 36C26026Q0871, issued by NCO 20 Network Contracting Office on July 22, 2026, with a due date of August 3, 2026 at 15:00 PT. The amendment corrects salient characteristics for line item 0001 that contained typographical errors in two specifications. Offerors must acknowledge receipt of this amendment prior to the submission deadline by completing the required form items, acknowledging receipt on each offer copy, or submitting separate written or electronic communication referencing the solicitation and amendment numbers.

The solicitation covers six line items for medical imaging equipment and accessories: (0001) Pain Management C-Arm Imaging Table with carbon fiber construction, 56" metal-free imaging space, electronic lift tower with four motion options including electric height range 26"-43", Trendelenburg tilt +15°/-11°, 10" longitudinal travel, and ±15° lateral tilt, 500 lbs weight capacity, and emergency stop switch; (0002) Fluor Extender Polycarbonate measuring 30" L x 23.5" W x 0.25" thick with maximum 0.85 mm AL aluminum filtration equivalent; (0003) Arm Hammock attachable to any face rest platform; (0004) Carbon Fiber Arm Board measuring 6" x 23" with 180° range of motion and 2" removable pad; (0005) Upgrade 5" casters; and (0006) Multi-Function Foot Control offering electronic vertical height, Trendelenburg tilt, lateral tilt, and longitudinal travel positioning. All terms and conditions from the original solicitation remain in full force and effect except as modified by this amendment.

View the file

Other files for this federal contract opportunity

Other files attached to Radiographic Imaging Table - See Amendment 07/30/2026, newest first.
File Type Posted
S02 36C26026Q0871 Radiographic Imaging Table.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

5. PROJECT NUMBER (if applicable)

CODE 7. ADMINISTERED BY

2. AMENDMENT/MODIFICATION NUMBER

CODE

6. ISSUED BY

8. NAME AND ADDRESS OF CONTRACTOR

4. REQUISITION/PURCHASE REQ. NUMBER 3. EFFECTIVE DATE

9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED

PAGE OF PAGES

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED

BPA NO. 1. CONTRACT ID CODE

FACILITY CODE CODE

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers

E. IMPORTANT:

is extended,

(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.

12. ACCOUNTING AND APPROPRIATION DATA

(REV. 11/2016)

is required to sign this document and return ___________ copies to the issuing office. is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.

15C. DATE SIGNED

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER

Contractor

16C. DATE SIGNED

14. DESCRIPTION OF AMENDMENT/MODIFICATION

16B. UNITED STATES OF AMERICA

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER 16A. NAME AND TITLE OF CONTRACTING OFFICER

15B. CONTRACTOR/OFFEROR

STANDARD FORM 30 PREVIOUS EDITION NOT USABLE

Prescribed by GSA - FAR (48 CFR) 53.243

(Type or print) (Type or print)

(Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

(Number, street, county, State and ZIP Code)

(If other than Item 6)

(Specify type of modification and authority)

(such as changes in paying office, appropriation date, etc.)

(If required)

(SEE ITEM 11)

(SEE ITEM 13)

(X)

CHECK

ONE

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

(Signature of person authorized to sign) (Signature of Contracting Officer)

1 2

0001 07-30-2026

463-26-3-511-0052

36C260

NCO 20 Network Contracting Office

ATTN: V4CONT

1601 E. Fourth Plain Blvd Bldg.17, Suite B428 Vancouver WA 98661

36C260

NCO 20 Network Contracting Office

ATTN: V4CONT

1601 E. Fourth Plain Blvd Bldg.17, Suite B428 Vancouver WA 98661

To all Offerors/Bidders

36C26026Q0871

07-22-2026

X

X X

See CONTINUATION Page

463-3660160-511-820100-3131 SP80EP1A1

X 1

The purpose of this amendment is to correct salient characteristics for line item 0001. The CO was made aware that there was a mistype for two specifications for line item 0001. The correct values are noted in bold for line 0001 below.

The due date remains 08/03/2026 at 15:00 PT.

Please provide a signed copy of this amendment with your response.

Tracy Heath Contracting Officer

CONTINUATION PAGE

Salient Characteristics:

0001 Pain management C-Arm Imaging Table

• Carbon fiber tabletop dimensions: 22” W x 84” L

• 56” metal free imaging space

• Carbon fiber integrated headrest with radiolucent tabletop pad

• Integrated face rest with crescent face pad

• Multi-function hand control

• Electronic lift tower

• Offers 4 motion options to include:

o Electric Height Range 26”-43” o Electric Trendelenburg Tilt +15°/-11° o Electric Longitudinal travel 10” o Electric Lateral tilt ±15°

• Emergency stop switch to cut power from the table in an emergency

• Locking casters for mobile or permanent positioning

• Safety straps

• Weight capacity should hold up to 500lbs

0002 Fluor Extender Polycarbonate

• Made of polycarbonate material – a radiolucent material

• Compatible with all imaging tables

• Shape is conducive to a variety of table placement applications

• Dimensions: 30” L x 23.5” W x 0.25” thick

• Aluminum Filtration Equivalent: Maximum of .85 mm AL @ KBp. HVL of 3.6 mm

0003 Arm Hammock

• Should attach to any face rest platform

0004 Carbon Fiber Arm Board

• Fully radiolucent

• Requires no mounting or attachment hardware – slides under table top pad

• Compatible with any model Pain management C-Arm table

• Should come with 2” thick removable pad

• Arm board dimensions: 6”x23”

• 180° range of motion

0005 Upgrade 5” casters

0006 Multi-Function Foot Control

• Should offer vertical height, Trendelenburg Tilt, Lateral Tilt, and Longitudinal travel positioning with electronic ease.