36C26026Q0808.docx

DOCX document 20 KB Posted

Attached to
6640--VMU Rack Washer and Bedding Dispenser
Solicitation number
36C26026Q0808
Issued by

About this file

This is a Sources Sought Notice issued by the Department of Veterans Affairs (VA), Network Contracting Office 20, to identify potential vendors for equipment upgrades and acquisitions supporting the Veterinary Medical Unit at VA Puget Sound Health Care System in Seattle, Washington. The requirement includes upgrading an existing Tecniplast Rack Washer (Model RW900GP, Serial Number 901507) with manufacturer-specified parts and acquiring two Tecniplast UP&DOWN Stand Alone Bedding Dispensers to replace and supplement existing bedding distribution equipment. The notice indicates the intended contract will be firm-fixed price. Responses must be submitted by July 17, 2026, at 1:00 PM Mountain Time via email to Contracting Officer Nazanin Kreiner (nazanin.kreiner@va.gov). The solicitation number is 36C26026Q0808, with the place of performance at 1660 South Columbian Way, Seattle, WA 98108.

Respondents must provide company name, address, SAM UEI, business size, point of contact information, and indication of current federal contracts (GSA Federal Supply Schedule, NASA SEWP, or other). Vendors must be authorized resellers of the OEM and provide an authorization letter from Tecniplast. The parts list for the rack washer upgrade includes 35 specific OEM components covering valves, gaskets, sensors, pneumatic equipment, and tubes. The two bedding dispensers must operate on single-phase 115V/60Hz power and include automatic lifting systems, dual augers for material dispensing, ultrasonic trigger sensors, touchscreen interfaces, and dual filtration systems. Delivery notification must occur two weeks prior to shipment, with installation and training by manufacturer-approved technicians to be completed no later than two weeks after delivery. The NAICS code is 339999 with a 550-employee size standard. This Sources Sought Notice does not obligate the Government to award a contract or issue a subsequent solicitation.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
VMU Rack Washer and Bedding Dispenser

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
98661
SOLICITATION NUMBER*
36C26026Q0808
RESPONSE DATE/TIME/ZONE
07-17-2026 1PM MOUNTAIN TIME, DENVER, USA
ARCHIVE
30 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
6640
NAICS CODE*
339999
CONTRACTING OFFICE ADDRESS
Network Contracting Office 20

ATTN: V4CONT

1601 E. Fourth Plain Blvd Bldg.17, Suite B428 Vancouver WA 98661

POINT OF CONTACT*

Contracting Officer Nazanin Kreiner nazanin.kreiner@va.gov email responses only

PLACE OF PERFORMANCE

ADDRESS
Department of Veteran Affairs

Puget Sound Health Care Systems

Veterinary Medical Unit

1660 South Columbian Way

Seattle WA

POSTAL CODE
98108

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION
nazanin.kreiner@va.gov

DESCRIPTION

THIS IS A SOURCES SOUGHT NOTICE ONLY.

This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method.

The intended contract is a firm-fixed price.

The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide Upgrade of Tecniplast Rack Washer and Acquisition of 2 Tecniplast Bedding Dispensers as outlined below in support of the Veterans Health Administration, VA Puget Sound Health Care System, 1660 South Columbian Way, Seattle, WA 98108.

Potential candidates having the capabilities necessary to provide for this requirement at a fair and reasonable price are invited to respond to this Sources Sought Notice via e-mail to Nazanin Kreiner at Nazanin.kreiner@va.gov no later than July 17, 2026, 1PM, Mountain Time. No telephone inquiries will be accepted.

RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION: Company name, address, SAM UEI, and business size; point of contact name, phone number, and e-mail address; whether services are presently offered on a current GSA Federal Supply Schedule contract, NASA SEWP, or any other Federal contract. NAICS Code 33999 with size standard of 550 employees, is applicable to determine business size standard. Please indicate whether proposed system is manufactured in the United States. Any questions or concerns may also be directed via email to Nazanin Kreiner at Nazanin.kreiner@va.gov. Telephone inquiries will not be accepted. Vendors must be authorized re-sellers of the OEM and provide an authorization letter from the OEM.

Salient Characteristics For Upgrade of Tecniplast Rack Washer and Acquisition of 2 Tecniplast Bedding Dispensers in the Veterinary Medical Unit

Background The Veterinary Medical Unit at VA Puget Sound has a requirement for upgrades to and replacement of equipment used to clean and to fill rodent housing cages with fresh bedding. The requested equipment has been approved and supported by VA Office of Research and Development through the LAM (Laboratory Animal Major Equipment) grant mechanism.

The Tecniplast rack washer (Tecniplast Model RW900GP, SN 901507) was installed as new equipment in 2012, and is now 14 years old. This washer is key to our facility’s function, in use every day of the week to clean cages, cage lids and wire-bar tops, feeders, bottles, enrichment items/cage furniture, cage racks, buckets and food barrels, and carts. For this reason, we need to extend the functionality of the Tecniplast rack washer now in use. A curated list of parts was provided by the Tecniplast technician. The installation of these parts (upgrade) will be performed by our in-house R&D Lab Operations Manager.

Equipment that is used to fill the rodent housing cages (an older model Tecniplast Model 9BDS+, SN 321238) must be replaced. We need to acquire 2 stand-alone bedding dispensers (Tecniplast Model UP&DOWN Stand Alone Bedding Dispenser) to replace the poorly functioning existing bedding dispenser and to add a dispenser to a separate facility location where staff have been doing cage setup by hand. Onsite setup and training of bedding dispensers is performed by the vendor.

Salient Characteristics Curated Parts List for upgrade/ repair of Tecniplast rack washer (Tecniplast Model RW900GP, SN 901507) Must be OEM parts obtained from Tecniplast, USA Must be packaged per manufacturer requirement Must include shipping in total cost.

ItemDescriptionPart NumberQty
1BUTTERFLY VALVE OMAL 494 CLAMP BS 4825 2"1/2-63,5+ DA+1 PN.ACTP-C0004760-005
2BUTTERFLY VALVE OMAL 494 CLAMP BS 4825 2"1/2-63,5 + DA+1 PN.ACT_90°OP.ADJP-C000477Q-003
3BUTTERFLY VALVE OMAL 494 CLAMP BS 4825 2"1/2-63,5 + 2STAGE+1 PN.ACTP-C000478S-001
4SILICONE CLAMP GASKET 2"PRIKG1200033
5CLAMP GASKET 4" (101)PRIKG1400011
6BUTTERFLY VALVE OMAL 494 CLAMP BS 4825 1"1/2-38,1 + DA+1 PN.ACTP-C0004741-004
71"1/4” CLAMP GASKETPRIKGI1140210
82" CLAMPPRIKMI200031
9STANDARD CYLINDER DSBC-63-160-PPV-A D.50 STROKE 160 STD ISO 15551 DBLE ACTPPNCL0630L42
10PROXIMITY SENSOR SMT-8M-A-PS-24V-E-0,3-M8DPPNFM0000062
11PNEUMATIC VALVE SERIES Y DN20PPNVR0000261
12PTFE CLAMP GASKET 3/4"PRIKG1034014
13CLAMP 3/4" - 1" - 1" 1/4PRIKMI034011
14STEAM TRAP KLINGER DTF + CLAMPDSTD00340100X101
15GASKET FOR CLAMP CONNECTION 1/2"PRIKGI012012
161/2" CLAMPPRIKMI012011
17BUTTERFLY VALVE OMAL 494 CLAMP BS 4825 3"-76,1 + DA+1 PN.ACTP-C000486P-001
182"1/2 CLAMP CONNECTION GASKETPRIKG1212042
19PROXIMITY SENSOR IB040BM46VB3PCEIP0000312
20PRESSURE REDUCER MS4-LR-1/4-D5-ASPPNRD0000041
21SINGLE-EFFECT PNEUMATIC VALVEPPNELA000262
22DOUBLE-EFFECT PNEUMATIC VALVEPPNELA000272
23SINGLE-EFFECT PNEUMATIC VALVE 3 WAYSPPNELA000282
24ELBOW QUICK CONNECTION D6 G 1/4" + OR GASKETPPNRSGB30005
25QUICK CONNECTION D6 G 1/8" + OR GASKETPPNRSGB20005
26QUICK CONNECTION D6 G 1/4" + OR GA SKETPPNRSDB30004
27QUICK CONNECTION D6 G 1/8"PPNRSDB20004
28QUICK CONNECTION D.6 M5PPNRSDB10004
29FLOW REGULATOR D6 G 1/8" + OR GASKET (UNLOAD)PPNRSGB20R14
30FLOW REGULATOR D6 G 1/8" + OR GASKET (LOAD)PPNRSGB20R04
31RILSAN TUBE 6X4 BLUEPTFR06040B05
32RILSAN TUBE 6X4 REDPTFR06040R05
33M12 PLUG QUICKON 0,34MM2 PHOENIX: SACC-M12MS-4QO-0,34PCESP0000094
34PROCESS PUMP PB1011-F01-1002 W/BUILT-IN SOLENOID VALVE/EPDM CONN. MALE M8PPDP00000294
35QUICK CONNECTION SERTO D.8 - 1/8" cod. SO 21121-8-1/8PPNRSDC20018

UP&DOWN - Stand Alone Bedding Dispenser (quantity = 2) Power supply requirements: Single Phase 115V / 60Hz Must include features:

- Shipping, setup and training in total cost -Automatic electric driven lifting system:

> Recessed position for bedding refilling operations > Raised position for bedding dispensing operations

- #2 Separate bedding (or selected enrichments) processable

- #2 Minimum level sensors

- #2 Independent augers for accurate material dispensing

- Dispensing triggered by ultrasonic sensors

- #20 Different dosage volumes settable

- 3.5" Colored touchscreen operator interface

- Operator protection system inclusive of double filtration level (G4+F7)

- Automatic adjustable working height for operator ergonomics

- Light Bedding Kit inclusive of #2 stirrers with 24V motors

- Up&Down Additional lifting control pad

Overall dimensions in resting position (L x W x H): 51.6" x 33.1" x 39.4" h Max height in working mode: 76.8" Bedding loading height: 36” Include 2 Power Cables (16' 5")

Specific Tasks Delivery:

a.Notify COTR at least two weeks before shipment occurs for planning for delivery, installation and training
b.Package and ship all equipment and components to the manufacturer specifications
c.Delivery address:
Veterinary Medical Unit
Warehouse 90D
Bldg. 100
1660 South Columbian Way
Seattle, WA 98108

Installation and Training (for Bedding Dispensers):

d.must be provided by Manufacturer approved technicians
e.must be scheduled no later than 2 weeks after the scheduled delivery date.

Performance Monitoring The performance of the contractor will be supervised by the COR, or by a designee such as the Veterinary Medical Unit Supervisor. The COTR is responsible for certifying the inspection and acceptance of products provided.

Security Requirements This requirement is for parts and equipment only. The contractor employees shall not have access to VA sensitive or computer information and will not require routine access to VA Facilities. Background Investigation is not required.

Disclaimer and Important Notes: This Sources Sought Notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. The Government will treat any information received as proprietary and will not share such information with other companies. Any organization responding to this Sources Sought Notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this announcement. There is no solicitation available at this time.

*= Required Field
Sources Sought Notice

Sources Sought Notice

File details come from the government source that posted it. Updated .