This document is a Presolicitation Notice for a boiler emission compliance project at the VA Portland HCS Vancouver Campus. The solicitation (36C26025Q0716) is set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSBC) and requires a comprehensive boiler emission testing service for three boilers in Building 3, with a response deadline of August 15, 2025, at 12:00 PM Pacific Time. The project involves performing multiple EPA-specified tests, including Volumetric Flow Rate, O2, CO2, NOx, CO, and Water Vapor tests, along with TC Calibration, to maintain the Southwest Clean Air Agency (SWCAA) permit 19-3332.

The contract will be executed by the Department of Veterans Affairs Veterans Health Administration, located at the VA Medical Center in Portland, Oregon. The boilers serve critical infrastructure functions, providing steam for laundry operations, sterile processing, heating hot water, and hot water distribution to five buildings. The testing is mandated every five years to ensure compliance with environmental regulations, specifically 40 CFR 60, and will be conducted by a qualified contractor with expertise in environmental testing and emissions analysis.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Presolicitation Notice Presolicitation Notice

SUBJECT*
Vancouver Boiler Emission Compliance

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
98661
SOLICITATION NUMBER*
36C26025Q0716
RESPONSE DATE/TIME/ZONE
08-15-2025 12:00 PACIFIC TIME, LOS ANGELES, USA
ARCHIVE
10 DAYS AFTER THE RESPONSE DATE
SET-ASIDE
SDVOSBC
PRODUCT SERVICE CODE*
H245
NAICS CODE*
541380
PLACE OF PERFORMANCE
VA Medical Ctr-Portland - Portland campus

3710 SW US Veterans Hospital Rd., Portland, OR 97239-2964

CONTACT INFORMATION

CONTRACTING OFFICE ADDRESS
Network Contracting Office 20

ATTN: V4CONT

1601 E. Fourth Plain Blvd Bldg.17, Suite B428 Vancouver WA 98661

POINT OF CONTACT*

Contract Specialist Meredith Valentine meredith.valentine@va.gov

DESCRIPTION

Statement of Work Boiler Emission Compliance, VA Portland HCS Vancouver Campus

· Perform a boiler emission test on 3 boilers in Building 3, VA Portland HCS Vancouver Campus

· Test to determine compliance with permit 19-3332 issued by Southwest Clean Air Agency (SWCAA) and 40 CFR 60.

· Perform three runs of Volumetric Flow Rate test per Environmental Protection Agency (EPA) M1 and M2.

· Perform three runs of O2, CO2, NOx, and CO test per EPA M3A, 7E and 10

· Perform three runs of Water Vapor test per EPA M4

· Perform TC Calibration per EPA ALT-011

This test is required every 5 years by SWCAA to maintain the permit for operation on the Vancouver boilers. The Vancouver boilers provide steam to maintain laundry operations, sterile processing, heating hot water and hot water to 5 buildings.