Presolicitation Notice Presolicitation Notice
| SUBJECT* |
| Boiler Calibration and Tuning |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 98661 |
| SOLICITATION NUMBER* |
| 36C26023Q0422 |
| RESPONSE DATE/TIME/ZONE |
| 05-19-2023 9AM PACIFIC TIME, LOS ANGELES, USA |
| ARCHIVE |
| 30 DAYS AFTER THE RESPONSE DATE |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| J045 |
| NAICS CODE* |
| 561210 |
| PLACE OF PERFORMANCE |
| Spokane VAMC |
4815 N Assembly St
Spokane WA
| POSTAL CODE |
| 99205 |
COUNTRY
CONTACT INFORMATION
| CONTRACTING OFFICE ADDRESS |
| NCO 20 Network Contracting Office |
ATTN: V4CONT
1601 E. Fourth Plain Blvd Bldg.17, Suite B428 Vancouver WA 98661
POINT OF CONTACT*
Contracting Specialist Jeffrey Hansen jeffrey.hansen2@va.gov
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
Technicians shall perform inspection, tuning, testing, calibrating, and adjustments of burners and boilerplant controls as specified below on #1, #2, and #3 boiler and auxiliary control devices. This shall be done in accordance with a schedule provided by VAMC Spokane. Boiler tuning and calibration shall be completed every October on the 350 hp boilers and every march on the 200 hp boilers. Auxiliary devices, and mainstream flow transmitters shell be calibrated annually.
Subtitle .............. 2X 350 HP Boiler Manufacturer........... Burnham Boiler Type............ Fire tube Boiler Year Built Design Pressure........ 200.00 PSI Operating Pressure..... 120.00 PSI [relief valve set pressure] Design Temperature..... 650.00 degrees Fahrenheit Rated Capacity………. 12,000 pounds per hour Fuel… Natural gas and or #2 fuel oil fired boilers
Subtitle .............. 2X 200 HP Boiler Manufacturer........... Burnham Boiler Type............ Fire tube Boiler Year Built Design Pressure........ 200.00 PSI Operating Pressure..... 120.00 PSI [relief valve set pressure] Design Temperature..... 650.00 degrees Fahrenheit Rated Capacity………. 6900 pounds per hour Fuel… Natural gas and or #2 fuel oil fired boilers
| *=Required Field |
| Presolicitation Notice |