SITE HIGH-VOLTAGE

Facility Transformer Schedule
TransformerBuildings ServedLocationFeeder SupplyCircuit BreakerkVASecondary VoltageWiringPhase%ZMFGS/NGallonsComments
1T12, 21, 72, 79GRNDS-79S2N & S2EVFI #3/VFI #3150480Y/277VΔ-Y3-Φ2.72014CP 1450004380111
2T228, 48GRNDS-28S2NVFI #2500480Y/277VΔ-Y3-Φ4.6199183JC908026220
3*T38, 50GRNDS-50S15NVFI #2112.5208Y/120VΔ-Y3-Φ3.11983830466-1154
4T434GRNDS-34S15NVFI #1150208Y/120VΔ-Y3-Φ4.91983830468-2139
5T5N46GRNDS-46S2NVFI #1500480Y/277VΔ-Y3-Φ4.52010CP 1050004950201
6T5E46GRNDS-46S2EVFI #1500480Y/277VΔ-Y3-Φ4.52010CP 1050004951201
7*T629, T108, T111GRNDS-29S5NVFI #1300208Y/120VΔ-Y3-Φ5.391991910785-A1295
8T7N27GRNDS-27S7NVFI #3300480Y/277VΔ-Y3-Φ1.68201313JC675360001223
9T7E27GRNDS-27S7EVFI #2300480Y/277VΔ-Y3-Φ1.68201313JC675370001203
10T8N77, 85A, T110GRNDS-77S7NVFI #2500208Y/120VΔ-Y3-Φ4.99199696J101064223
11T8E77, 85AGRNDS-77S7EVFI #1500208Y/120VΔ-Y3-Φ5.02010CP 1050004949203
12T9N67GRNDS-67S14NVFI #1500480Y/277VΔ-Y3-Φ4.52010CP 1050004952203
13T9E67GRNDS-67S14EVFI #4500480Y/277VΔ-Y3-Φ4.42010CP 1050004953203
14T10N85GRNDS-85S14NVFI #31000480Y/277VΔ-Y3-Φ5.67P3166440
15T10E85GRNDS-85S14EVFI #31000480Y/277VΔ-Y3-Φ5.52010CP 1050004956297
16T126GRNDS-6S19NVFI #245208Y/120VΔ-Y3-Φ2.32014CP 1450004379103
17T134, 44, 71GRNDS-44S19NSC-23167120/240VΔ-Y1-Φ2.91983831088397141
18T141, 24, 52GRNDS-24S19NSC-2475120/240VΔ-Y1-Φ2.81983831086321121
19T1523, 30, 45, 66GRNDS-23S19NSC-2575120/240VΔ-Y1-Φ2.81983831086975121
20T16N88GRNDS-88S19NVFI #1300480Y/277VΔ-Y3-Φ5.291991PPJ-0695170
21T16E88GRNDS-88S19EVFI #1300480Y/277VΔ-Y3-Φ4.02010CP 1050004947168
22T17106GRNDS-106S15NVFI #375480Y/277VΔ-Y3-Φ3.2198585JA351088121
23T18 E/N107GRNDS-107S19N/S19EVFI #3/VFI #4150480Y/277VΔ-Y3-Φ3.72010CP 1050004946142
24T1943GRNDS-43S15NVFI #4150208Y/120VΔ-Y3-Φ4.81983830468-1139
25T20N110GRNDS-110S5NVFI #21500480Y/277VY-Y3-Φ5.320082544122408287
26T2123, 45GRNDS-23S19NSC-25150208Y/120VΔ-Y3-Φ4.931990P806190TZE265
27*T22T112, T113GRNDS-106S15NVFI #350120/240VΔ-Y1-Φ2.1199494LL67201630
28T23114GRNDS-114S19NSC-25500480Y/277VΔ-Y3-Φ5.2200037014108230
29T24115, 116GRNDS-115S7N/S19NSC 10225208Y/120VΔ-Y3-Φ3.02011CP 1150006917124
30T25N109GRNDS-109S7NVFI #11000480Y/277VΔ-Y3-Φ5.52010CP 1050004954297
31T25E109GRNDS-109S7EVFI #31000480Y/277VΔ-Y3-Φ5.52010CP 1050004955297
32T26N117GRNDS-117S19NVFI #4300480Y/277VΔ-Y3-Φ4.52201129335194-001-02203
33T26E117GRNDS-117S19EVFI #2300480Y/277VΔ-Y3-Φ4.52201129335194-001-01203
34T27NMtn. CoveGRNDS-33S19NSC-23500208Y/120VΔ-Y3-Φ5.02011CP 1150012850198
35T28N121, 122GRNDS-121S14NVFI #2300208Y/120VΔ-Y3-Φ4.62014CP 1450007699176
36T28E121, 122GRNDS-121S14EVFI #275208Y/120VΔ-Y3-Φ3.42014CP 1450007697119
37T29N123GRNDS-123S19NSC-24500480Y/277VΔ-Y3-Φ4.22014CP 1450005256167
38T30N124GRNDS-124S19NSC-23150208Y/120VΔ-Y3-Φ3.22015CP 1550000687106
39T31N120GRNDS-120S14NVFI #2300480Y/277VΔ-Y3-Φ4.52016CP 1650002710162
40T31E120GRNDS-120S14EVFI #245480Y/277VΔ-Y3-Φ3.42016CP 1650002706119
41T32NParking GarageGRNDS-126S19NSC-25A150208Y/120VΔ-Y3-Φ4.82018CP 1850003359125
42T33N23, 45GRNDS-23
43
*Denotes that load-side circuit breakers exist within secondary compartment of transformer

February 7, 2019

&P of &N

INDOOR DRY TYPE

INDOOR DRY TYPE TRANSFORMERS
Updated:8/21/19
Building NumberLocal IdentifierLocationEquipment Number*NOT IN ETAP
27T1102EE38017
T2G14EE36946
T3G14EE36947
T4GRNDSEE36962
T5GRNDSEE36961
28T1G01EE14585
T2G04EE15050
T3
T4
T5G04EE33812x
T6G04EE33811x
46T1G01BEE13755
T2G01EE13757
T3106EE13758
T4101EE13756
T5G05EE38963

48 48 100 EE13741

67T1G25AEE36906
T2G25AEE36907
T3G25AEE36908
T4G25AEE36909

79 T1 101 EE13661

82 T1 100

83 T1 101

85T1117EE13580
T2117EE13579
T3117EE13575
T4140EE14661
T5140EE14662
T6232CEE7658
T7232CEE7659
T8301CEE--
T9301CEE11673
T10G10EE17020
T11G10EE14675
T12PH1EE14692x
T13G24AEE16094
T14112HEE33707
T15112HEE33708
T16215FEE33713
T17215FEE33714
T18112HEE33729x
T19117EE36924
T20PH6EE38059
T21PH6EE38060
T22GRNDSRemoved?XFeeds PNL 85-fed now from 27-T5
T23215H
88T1133EE12199
T2133EE13607

106 T1 101 EE13634

107 T1 101 EE13635

109T1201EE12769
T2201EE12768
110T1116EE5100
T2G25EE29737
114T1115EE12482
T2212EE12487
117TN1112EE30945
TE1112EE30946
TN2217EE30947
TE2217EE30948
120L1102EE43559
E1102EE43558
123T1106EE38841X
T2106EE38842X
T3200EE38843X
T4200EE38844X